Corrected Amends 116 & 99 to Licenses NPF-04 & NPF-07,adding Addl Surveillance Requirements for butterfly-type Containment Isolation Valves in Containment Purge & Vacuum Ejector Lines
ML20247C987
Person / Time
Site: North Anna  
Issue date: 07/19/1989
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20247C989 List:
References
NUDOCS 8907240498
Download: ML20247C987 (6)


Text

- _ _ _

1 1

3/4.6 CONTAINMENT SYSTEMS 1

3/4~.6.1 CONTAINMENT CONTAINMENT INTEGRITY LIMITING CONDITION FOR OPERATION 3.6.1.1 Primary CONTAINMENT INTEGRITY shall be maintained, i

APPLICABILITY: MODES 1, 2, 3 and 4 ACTION:

Without primary CONTAINMENT INTEGRITY, restore CONTAINMENT INTEGRITY within one hour or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOW.. within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

]

SURVEILLANCE REQUIREMENTS 4.6.1.1 Primary CONTAINMENT INTEGRITY shall be demonstrated:

a.

At least once per 31 days by verifying that all penetrations

  • not capable of being closed by OPERABLE containment automatic isolation valves and required to be closed during accident conditions are closed by valves, blind flanges, or deactivated automatic valves secured in their positions, except as provided in Table 3.6-1 of Specification 3.6.3.1., and b.

By verifying that each containment air lock is OPERABLE per Specification 3.6.1.3.

c.

After each closing of the equipment hatch, by leak rate testing the eouipment hatch seals with gas at Pa, greater than or equal to 44.1 psig, and verifying that when the measured leakage rate for these seals is added to the leakage rates determined' pursuant to Specification 4.6.1.2.d for all other Type B and C penetrations, the combined leakage rate is less than or equal to 0.60 L -

)

a d.

Fach time containment integrity is established after vacuum has been broken by pressure testing the butterfly isolation valves in the containment purge lines and the containment vacuum ejector line.

  • Except valves, blind flanges and deactivated automatic valves which are located inside the containment and are locked sealed or otherwise sealed in the closed position. These penetrations shall be verified closed during each COLD SHUTDOWN except that such verification need not be performed more often than once per 92 days.

NORTH ANNA - UNIT 1 3/4 6-1 Amendment No.116 8907240498 890719 DR ADDCK 0500 8

L

CONTAINMENT SYSTEMS CONTAINMENT LEAKAGE LIMITING CONDITION FOR OPERATION 3.6.1.2 Containment leakage rates shall be limited to:**

l a.

An cverall integrated leakage rate of:

1.

s L, 0.1 percent by weight of the containment air per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> at f,, a 44.3 pst% or

[

b.

A combined leakage rate of s 0.60 L, pressurized to Pfor all penetratio subject to Type B and C tests, when

,, a 44.1 psig.

l APPLICABL TY: MODES 1, 2, 3 and 4.

ACTION:

With either (a) the measured overall, integrated containment leakage rate exceeding 0.75 L or (b penetrations and, valves )subjectwith the measured combined leakage rate for all to Type 8 and C tests exceeding 0.60 L restore the leakage rate (s) to within the limit (s) prior to increasing tfle, Reactor Coolant System temperature above 200'F.

SURVEILLANCE REQUIREMENTS 4.6.1.2 The containment leakage rates shall be demonstrated at the following test schedule and shall be determined in conformance with the criteria specified in Appendix J of 10 CFR 50 using the methods and provisions of either ANSI N45.4-1972 for leakage rate point data. analysis or ANSI /AMS-56.8-1987 for mass point data analysis with a minimum test duration of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.**

(

Three Type A tests (Overall Integrated Containment Lehkage Rate) a.

shall be conducted at 40 + 10 month intervals during shutdown at Pa ?. 44.1 psig during each 10-year service period. -The third test

(

of each set shall be conductdd during the shutdown for the 10-year plant inservice inspection.*

  • The third test of the first 10-year service period shall be conducted during the 1989 Refueling /10-Year ISI Outage.
    • For Specification 3/4.6.1.2 only, P, shall be 40.6 psig.until completion of the Cycle 7 to 8 refueling outage.

Following this outage, P, shall be 44.1 psig.

!! ORTH A!!MA - UNIT 1 3/4 6-2 Amendment 'lo. 196,798,110

e 3/4;6 CONTAINMENT SYSTEMS 3/4.6.1 CONTAINMENT CONTAINMENT INTEGRITY LIMITING CONDITION FOR OPERATION 3.6.1.1 Primary CONTAINMENT INTEGRITY shall be maintained.

APPLICABILITY: MODES 1, 2, 3 and 4.

ACTION:

Without primary CONTf.I%f *Y INTEGRITY, restore CONTAINMENT INTEGRITY within one hour or be in at 1sagt NOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD

  1. HUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.1.1 Primary CONTAINMENT INTEGRITY shall be demonstrated:

At least once per 31 days by verifying that all penetrations

  • not a.

capabit of being closed by OPERABLE containment automatic isolation valves and required to be closed during accident conditions are closed by valves, blind flanges, or deactivated automatic valves secured in their positions, except as provided in Table 3.6-1 of Specification 3.6.3.1.. and b.

By verifying that each containment air lock is OPERABLE per Specification 3.6.1.3.

After each closing of the equipment hatch,- by leak rate testing the c.

equipment hatch seals with gas at Pa, greater.than or equal to 44.1 psig, and verifying that when the measured leakage rate for these seals is added to the leakage rates determined pursuant to Specification 4.6.1.2.d for all other Type B and C penetrations, the combined i

leakage rate is less than or equal to 0.60 La.

l d.

Each time containment integrity is established after vacuum has 4

l been broken by pressure testing the butterfly isolation valves in.

the containment purge lines and the containment. vacuum ejector line.

  • Except valves, blind flanges and deactivated automatic valves which are located inside the containment and are locked sealed or otherwise sealed in the closed position. These penetrations shall be verified closed during each COLD SHUTDOWN except that such verification need not be performed more often than once per 92 days.

l NORTH ANNA - UNIT 2 3/4 6-1 Amendment No.99 4

l

~

.w CONTAINMENT SYSIRi1 CONTAINMENT LEAKAGE LIMITING CONDITION FOR OPERATION 3.6.1.2 Containment leakage rates shall be limited to:**

An overall integrated leakage rate of:

a.

1.

Less t1an or equal to L 0.1 percent by weight of the containment air per 24 houfs, at P,, greater than or equal to 44.1 psig, or b.

A combined leakage rate of less than or equal to 0.60 L for all snetrations and valves subject to Type 8 and C telts, when pressurized to P,, greater than or equal to 44.1 psig.

APPLICABILITY: MODES 1, 2, 3 and 4.

ACTION:

With either (a) the measured overall integrated containment leakage rate exceeding 0.75 L or (b penetrations and, valves ) subject to Type B and C tests exceeding restore the overall integrated leakage rate to less than 0.75 L and tfle combined leakage rate for al_1 penetrations subject te Type B and C' tests to less than or equal to 0.60 L, prior to increasing the Reactor Coolant System temperature above 200'F.

ERVEILLANCE REQUIREMENTS 4.6.1.2 The containmut leakage rates shall be demonstrated at the following test schedule and shall h determined in conformance with _ the criteria specified in Appendix J of 10 CFR 50 using the. methods and provisions of either ANSI'N45.4-1972 for leakage rate point data analysis or At!SI/ANS-56.8-1987 for m. ass point data andlysis with a minimum test duration of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.**

l Three Type A tests (Overall Integrated Containment Leadge Rate) a.

shall be conducted at 40 + 10 month intervals during shutdown at Pa greater than or equal to 44.1 psig during each 10-year service The third test of'each set shall be conducte.d during the l

period.

shutdown for the 10-year plant inservice inspection.*

  • The second test of the first 10. year service period shall be conducted during the 1989 Refueling Outage.
    • For Specification 3/4.6.1.2 only. P,Following this outage shall be 40.6 psig until completion of the Cycle 6 to 7 refueling outage,

,P shall be 44.1 psig.

a

?!0RTH ATIA - UNIT 2 3/4 6-2 Amendment ?to. 72.7%, 96

d

.k i

4 CONTAINMENT SYSTEMS J

BASES l

l 2)

That the peak clad fuel temperature will remain less than 2200*F for a LOCA and 3)

That for either a LOCA or MSLB; a)

The peak containment pressure will be limited to the upper containment design pressure of 45 psig, b)

The containment internal pressure can be returned sub-atmospheric within 60 minutes, and c)

Safety related equipment within the containment will not

.j experience temperatures greater than those to which they have previously been qualified.

{

l d)

It is a design criteria that the containment internal pres-(

sure remain subatmospheric after 60 minutes.

i The limits shown in Figure 3.6-1 and Specification 3.6.1.5 are. con-sistant with the assumptions of the accident analyses which. included j

consideration of instrument loop uncertainties.

3/4.6.1.6 CONTAINMENT STRUCTURAjLNTEGRITY This limitation ensures chat the structural integrity of th,e con-tainment will be maintained.omparable to the original design standards for the life of the facility. Structural integrity is required to' l

ensure that the containment will withstandtthe design. pressure of 4

45 psig.

The visual examination of the concrete and liner and the Type A leakage tests are sufficient to demonstrate this capability.

l 3/4.6.2 DEPRESSURIZATION AND COOLING SYSTEMS 3/4.6.2.1 and 3/4.6.2.2 CONTAINMENT QUENCH AND RECIRCULATION SpARY SYSTEMS The OPERABILITY of the containment spray systems ensures that containment depressurization and subsequent return to subatmospheric l

pressure will occur in the event of a LOCA. The pressure reduction and

}

resultant termination of containment leakage are consistent with the l

assumptions used in the accident analyses.

I

\\

NORTH ANNA - UNIT 1 B 3/4 6-2 Amendment No.110

F

.s d

3/4.6 CONTAINMENT SYSTEMS i

BASES 3/4.6.1 CONTAINMENT 3]4.6.1.1 CONTAINMENT INTEGRITY CONTAINMENT; INTEGRITY ensures that the release of radioactive materials from the containment atmosphere will be restricted to those leakage paths and asstciated leak rates assumed in the accident analyses. This restriction, in I

conjunction with the leakage rate limitation, will limit the site boundary radiation doses to within the limits of 10 CFR 100 during accident conditions.

Leake.ge integrity tests in the containment purge lines and the containment vacuum ejector system lines is to identify excessive degradation of the resilient seats of these valves. These tests will be performed in addition to the Type C tests required by 10 CFR Part 50, Appendix J and will. not relieve t:1e responsibility to conform with Appendix J.'

,3/4.6.1.2 CONTAINMENT LEAKAGE The limitations on containment leakage rates. ensure that the total containment leakage volume will _ not exceed the valu'e assumed in the accident analyses at the peak accident pressure, Pa. As an added conservatism, the measured overall integratad leakage rate is further lii;;ited to less than or equal to 0.75 La during performance of the periodic test to account for possible degradation of the containment leakage barriers between leakage tests.

l The surveillance testing for measuring leakage rates are consistent with the requirements of Appendix "J" of 10 CFR 50. Due to the increased accuracy of the mass-point method for containment integrated leakage testing, the mass-point method referenced in ANSI /ANS 56.8-1987 can be used in lieu of the methods described in ANSI N45.4-1972.

3/4. 6.1. 3 CONTAINMENT AIR LOCKS, The limitations on closure and leak rate for the containment air locks are required to meet the restrictions on CONTAINMENT INTEGRITY and containment leak rate. Surveillance testing of the air lock seals provides assurance that the overall air lock leakage will not become excessive due to seal damage during the intervals between air lock leakage tests.

3/4.6.1.4 and 3/4.6.1.5 INTERNAL PRESSURE AND TEMPERATURE The limitations on containment internal pressure and average. air temperature ensure that

1) The containment pressure is prevented from reaching the containment lower design pressure of 5.5 psia for an inadvertent containment spray actuation, NORTH ANNA - UNIT 1 B 3/4 6-1 Amendme;.t No. 198 116