ML20246K754

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-346/89-12 on 890313-17 & 0418 & Notice of Violation
ML20246K754
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 05/05/1989
From: Miller H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Shelton D
TOLEDO EDISON CO.
Shared Package
ML20246K759 List:
References
NUDOCS 8905180138
Download: ML20246K754 (2)


See also: IR 05000346/1989012

Text

_ _ _ _ _ _ _ _ _ _ _

r

.

.

-

.

,

fm '%

'

MAY 5 1989

.

.

Docket No. 50-346

Toledo Edison Company

ATTN: Mr. Donald Shelton

Vice President

Nuclear

Edison Plaza

300 Madison Avenue

Toledo, OH 43652

Gentlemen:

This refers to the routine safety inspection conducted by Mr. Joseph Ulie

of this office on March 13-17 and April 18, 1989, of activities at the

Davis-Besse Nuclear Station authorized by NRC Operating License No. NPF-3

and to the discussion of our findings with Messrs. T. Myers and L. Storz

and other members of your staff at the conclusion of the inspection. The

purpose of this inspection was to review the implementation of the licensee's

fire protection program.

The' enclosed copy of our inspection report identifies areas examined during

the inspection. Within these areas, the inspection consisted of a selective

examination of procedures and representative records, observations, and

interviews with personnel.

During this inspection, certain of your activities appeared to be in violation

of NRC requirements, as specified in the enclosed Notice. A written response

is requirea. With regard to Item 2 of the Notice of Violation, we are concerned

about the recurring deficiencies in the fire watch program area. Additional

personnel training and technical staff review oversight appear necessary

to ensure proper implementation of the fire watch program. In your response

to-the Notice of Violation, please address the actions you are taking or plan

to take to correct fire watch program deficiencies.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter, the enclosures, and your response to this letter will be placed

in the NRC Public Document Room.

The responses directed by this letter and the accompanying Notice are not

subject to the clearance procedures of the Office of Management and Budget

as required by the Paperwork Reduction Act of 1980, PL 96-511.

89051%h

PDR

$ p[ ,\

'

'O

- _ - - _ _ _ _ _ _ _ _ _ _ _ _ . - . _ _ . _ _ _ _ -

,z .

! ,

..

Toledo Edison Company 2

MAY 5 1989

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

'galGINAL SIG!!ED BY. iiUBERT J. L--

, Hubert'J. Miller, Director

Division.of Reactor Safety

Enclosures:

1. Notice of Violation

2. Inspection Report

No. 50-346/89012(DRS)

s

cc w/ enclosures:

L. Storz, Plant. Manager

DCD/DCB (RIDS)

Licensing Fee Management Branch

Resident Ins 3ector, RIII

, Harold W. Koin, Ohio EPA

James W. Harris, State of Ohio

Roger Suppes, Ohio

' Department of Health

State of Ohio, Public

Utilit u Commission

-

RIII RIIT '

RIII R RI

jaw /lc Ga er C 7 ler

i;

j 4 tte

05/ /89 05/f/89

~

f}Md 7

05 #5 /89

i

l