Advises That Util 890829 Emergency Tech Spec Change Request Re RHR Loop B HX to Be Fed from RHR C & D Svc Water Pumps Via Crosstie Line Until 891101 Acceptable
ML20246K686
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 08/29/1989
From: Virgilio M
Office of Nuclear Reactor Regulation
To: Kovach T
COMMONWEALTH EDISON CO.
References
NUDOCS 8909060038
Download: ML20246K686 (3)


Text

. - . - - - - - -- - - - - - - ~-

(J1# . _ . - - - - - - - Docw (%

  • u-8-g'"'%,, '

'n UNITED STATES . '

NUCLEAR REGULATORY COMMISSION j g  !$' [ $- WASHINGTON, D. C. 20555

(....g 1

August 29, 1989 Docket Nos. 50-254.and'50-265=

Mr. Thomas J. Kovach

' Nuclear Licensing Manager Commonwealth Edison Company

+

Post Office Box 767 Chicago, Illinois 60690

Dear Mr. Kovach:

SUBJECT:

EMERGENCY TECHNICAL SPECIFICATION CHANGE - QUAD CITIES STATION, UNIT NOS. 1 AND 2 By letter dated August 29,.1989, you requested an emergency Technical

' Specification change which would permit the "B". loop of the Residual Heat Removal (RHR) heat exchangers on each unit to be fed from the RHR."C" and "D" service water pumps on Unit I via the cross-tie line until November 1, 1989.

.' This emergency Technical Specification change is required to commence startup of Unit 2 and satisfy the RHR requirements as specified in the FSAR that one RHR pump.ard one RHR service water pump per loop be operational.-

We have reviewed your evaluation and the justification provided in your submittal and find it acceptable. This. letter confirms the verbal granting of a temporary waiver of compliance for the above change for Unit Nos.1 and 2.

This waiver of compliance will be in effect through September 1, 1989 while we complete.the. processing of your emergency change request.

Sincerely,.

1 ( W Martin J. Virgilio, Acting Assistant Director for Regions III and V Division of Reactor Projects III, IV, V, and Special Projects Office of Nuclear Reactor Regulation cc: See next page Dr PFoi t i 1 h

gnt?M GENW P

ra

-~

Mg, ,

i* MrT Thomas J. Kovach Quad Cities Nuclear Power Station 1 LComonwealth Edison Company - Units 1=and 2 y

cc*

Mr. Stephen E. Shelton.

Vice President Iowa'-111tncis Gas and Electric Company P.10. Box 4350.

. Davenport, Iowa 52808 Michael I. Miller, Esq.

'Sidley and Austin v 'One First National Plaza Chicago Illinois 60603 Mr. Richard Bax -

Station Manager Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova. Illinois 61242 Resident Inspector

- U. S. Nuclear Regulatory Comission 22712 206th Avenue North

.Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors-1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, Illinois 61201 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive l

' Springfield, Illinois 62704 Regional Administrator, Region III U. S. Nuclear Regulatory Comission

-799 Roosevelt Road, Bldg. d4 Glen Ellyn, Illinois 60137 l

i; _ _ . _ _ _ . _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ - - _ - - .

'r

[.

. August 29, 1989 Docket Nos. 50-254 and 50-265 Mr. Thomas J. Kovach DISTRIBUTION:

Nuclear Licensing Manager (

Commonwealth Edisnn Company IDocket #11e. 50-254/265)_

NRC/Lochl PDRs OGC(FYI m)

L Post Office Box 767 PD32 Reading EJordan Chicago,. Illinois 60690 MJVirgilio BGrimes LLuther ACRS(10)

Dear Mr. Kovach:

BSiegel Gray File PShemanski EGGreenman, RIII

SUBJECT:

EMERGENCY TECHNICAL SPECIFICATION CHANGE - QUAD CITIES STATION, UNIT NOS. 1 AND 2 By letter dated August 29, 1989, you requested an emergency Technical Specification change which would permit the "B" loop of the Residual Heat Removal (RHR) heat exchangers on each unit to be fed from the RHR "C" and "D" service water pumps on Unit I via the cross-tie line until November 1, 1989.

This emergency Technical Specification change is required to commence startup of Unit 2 and satisfy the RHR requirements as specified in the FSAR that one RHR pump and one RHR service water pump per loop be operational.

We have reviewed your evaluation and the justification provided in your submittal and find it acceptable. This letter confirms the verbal granting of a temporary waiver of compliance for the above change for Unit Nos. I and 2.

This waiver of compliance will be in effect through September 1, 1989 while we corcplete the processing of your emergency change request.

Sincerely, Martin J. Virgilio, Acting Assistant Director for Regions III and V Division of Reactor Projects III, IV, V, and Special Projects Office of Nuclear Reactor Regulation cc: See next page <

$W PDIII-2 LLuth -

PDIII-2 BSiegeI PDIII-2[ki PShemans

. f. (A)AD:DRSP35 MVirgilio RIII:DRP EGGreenman hg 'M-8/A 9 8/q/8Lf 8/24}/89 8/gn/89 8/$1/89 g.