ML20246J824
| ML20246J824 | |
| Person / Time | |
|---|---|
| Site: | 05000563 |
| Issue date: | 05/04/1976 |
| From: | Wilson B GENERAL ELECTRIC CO. |
| To: | NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| Shared Package | |
| ML20246J751 | List:
|
| References | |
| FOIA-89-330 NUDOCS 8909050274 | |
| Download: ML20246J824 (4) | |
Text
-
[
O O
GENER AL h, ELECTRIC NUCLEAR ENERGY
~~
PROGR AMS DIVISION
- GENERAL ELECTRIC COMPANY,175 CURTNER AVENUE, SAN Jose CAltFoRNIA 95125 Phone (408) 297-3000 TWX No. 910-3384116 NUCLEAR ENERGY INTERNATIONAL OPERATIONS May 4, 1976 Director of. Nuclear Materials Safety & Safeguards U.S. Nuclear Regulatory Comission Washington, D. C.
20555
Subject:
APPLICATION FOR EXPORT OF NUCLEAR REACTORS Pursuant to the Atomic Energy Act of 1954, as amended, and Section 50.65 of 10CFR Part 50, application'is hereby submitted for a license to export a nuclear power station, K0EBERG, from the United States to the Republic of South Africa.
Detailed information required by 10CFR 50.65 is set forth hereunder:
- 1) Applicant General Electric Company (GE) and its wholly owned subsidiary General Electric Technical Services Operation, Inc., (GETSCO)
- 2) Address of Applicant 175 Curtner Avenue - M/C 871 San Jose, California 95125
- 3) Description of Applicant's Business GE manufactures and sells a variety of products including nuclear reactors and electrical generating distribution and utilization equipment and devices.
GETSCO provides a variety of services including export of GE supplied equipment and erection and startup of nuclear power plants at foreign locations.
8009050274 890831 PDR FOIA 57/D/76 -
)
ggg&w n
rnfuAu~
)
MOKDENA89-330 PDR jf,g 7v.
m ww u
FEE EXEMPT-N~^
f(
g_,
o,,,
m
,.y...
3
i O
O
'GENER AL $ ELE CTRIC May 4, 1976
' O.S. Nuclear Regulatory Comission Page 2
- 4) Corporate Infonnation of Applicant GE is incorporated in the state of New York with a principal place of business at One River' Road, Schenectady, New York. GETSCO is incorporated in the state of Delaware with a principal place of business at 175 Curtner Avenue, San Jose, California, 95125.
Neither GETSCO, nor GE, is owned, c6ntrolled, or dominated by an alien, a foreign corporation, or foreign government.
- 5) Export Arrangements Arrangements for export will be made only by the applicant.
- 6) Ultimate Consignee
. ELECTRICITY SUPPLY COINISSION 204 Smit Street P.O. Box 1091 Johannesburg 2000 South Africa 7)
Intermediate Consignee General Electric Technical Services Co., Inc. (GETSCO-RSA)
P.O. Box 5031 Benoni South 1502 Transvaal, South Africa l
- 8) Proposed First-Shipment August 1, 1976
- 9) Proposed Completion of Shipments August 1,1986 L
e i
.--_______-__-__________________A
]
/.
L'y O
O 1
IENE&AL $ ELECTRIC ~
~
May 4, 1976.
l
~
)
U.S., Nuclear Regulatory Comission Page 3 i
10)' Proposed Initial Criticality February 1, 1982
- 11) Proposed Expiration Date January 1,1987 12). Total Value of Export
$200,000,000 Additional Informaticri:
- 1) General Description of Nuclear Reactor Two GE forced circulation, single cycle, light water cooled and moderated boiling water reactors each with a design power level of 965.8 MWe. The reactors are to be known as Units 1 and 2, respectively, of the Koeberg Nuclear Power Station and will be located on a site about 30 kilometers north of Capetown in the Cape Province of the Republic of South Africa.
- 2) Structuret, Systems and Components to be Exported are Classified within the Followinc Categories 1)
Reacior Coolant Pressure Boundry 11)
Instrumentation iii)
Fuel Handling Equipment iv)
Spare or Replacement Components v)
Equipment or Tools vi)
Other Items:
- 1) Standby Liquid Control System
- 2) Cleanup & Filtering Systems f
i
. - -.. _ - _ _ ~ _ _ _ _ ~ _. _ _ -. _ _ _ _ _ _ _ _ _ _ _ -. - _ _ _ _ _ _ - _ _
O
.
- GENERAL h ELEC7RIC O
May 4, 1976 U.S. Nuclear Regulatory Commission Page 4
/
I
- 3) C'unponents Not Intended to Remain With the Facility GE hereby requests authorization to dispose of, or return to the United l
States, any component or material exported under a license issued pursuant to this application and to transfer such components to another reactor site which is being or was' constructed by GETSCO, GE or its licensee.
Very truly yours,
'h
. D. Wilson, Manager Government Relations and Export Licensing M/C 871 - Ext.1380
-ijm STATE OF CALIFORNIA
)
ss:
COUNTY OF SANTA CLARA
)
Subscribed and sworn to before me this 4th day of May, 1976.
$@ $/dn Notdry Public in'and for Said County and State 0 IC A S,
. g 1 php My Comm. Expires December 9, 1979 p
fWOTARY PUBLic. CALIFORNIA(
SANTA My e mm. CLARA CCUNTY expires DEC 9. 'O'D
~-
e t
.. _. _ _ _ _ _ _. _ _ _ _ _ _. _ _ _ -. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ - - _ _ _ _ _ _ _ _ _ _. _ _. _ _