Text
- _ _ _ _ _ _ - - _ _ - _
_-
b@Clk
'
..-
..
..
. . . .
-
,
JUN 2 71999
i
Docket Nos. 50-325, 50-324'
i
~A
l
Carolina Power and Light Company
l
,'
~
ATTN: Mr. Lynn W. Eury
,
Executive Vice President
i
Power Supply
,
P. 0.' Box 1551
-!
Raleigh, NC 27602
!
Gentlemen:
. StlBJECT:
NRC~ INSPECTION REPORT NOS. 50-325/89-13 AND 50-324/89-13
This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by
~
W. M. Sartor on May 22-24, 1989.
The inspection included a review of
activities authorized for 'your Bruh. wick facility.
At the conclusion of the
inspection, the findings were discussed with those members of your staff
j
identified in the enclosed inspection report.
!
Areas ex6 mined during the inspection. are identified in the report.
Within
these areas, the inspection consisted of selective examinations of procedures
and . representative records, interviews with personnel, and observation of.
j
activities in progress.
1
i
.'Within the scope of ' the inspection, no violations 'or deviations were
'!
identified,
i
Your attention is directed towards the' licensee- identified deficiency in
Paragraph 6 : and discussed with licensee representatives as referenced in
Paragraph 6.
In accordance with the provisions of 10 CFR 50, Appendix E, .
Paragraph IV.F.5, that all deficiencies shall be corrected, please provide a
written summary of the corrective actions taken or planned in response to the
,
deficiency within 30 days of the date of this report.
Your attention is also
I
directed to.the exercise weakness identified in Paragraph 2; to which your
l
corrective actions will be reviewed during future exercises.
J
'In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,
Title 10, Code of Federal Regulations, a copy of this letter and its enclosure
will be placed in the NRC Public Document Room.
!
8907130028 890627
ADOCK 05000324
8
(
Q
L--____-____-
-
- - _ - - - _ _
- -
.
.
,
4
Carolina Power and Light Company
2
Should you have any questions concerning this letter, please contact us.
Sincerely,
or(9(inal sqncd bc)
(A) - lInc fcr
Douglas M. Collins, Chief
Radiological Protection Branch
Division of Radiation Safety
and Safeguards
Enclosure:
NRC Inspection Report
cc w/ encl:
R. B. Starkey, Jr. , Manager
Brunswick Nuclear Project
J. L. Harness, Plant General Manager
State of North Carolina
bec w/ encl:
NRC Resident Inspector
Document Control Desk
1
l
$s
f*
WSartor W ankin
HDanfe
6/ 24 / 8 9
6/$89
6[h39
i
_ _ - _ - - _ - _ - -
--
,