_- - _ _ - -
LASALLE COUNTY NUCLEAR POWER STATION UNITS ONE AND TWO.
DOCKET NUMBERS 50-373 AND 50-374 ERRATA TO THE EFFLUENT AND WASTE DISPOSAL SENIANNUAL REPORT (1985)
GASEOUS EFFLUENTS-SUNNATION OF ALL RELEASES First Second Quarter Quarter A. Fission and Activation Gases
- 1. Total release Ci 6.93E+01 7.48E+00
- 2. Average release rate for period uC1/sec 7.13E+00 9.43E-01
- 3. Percent of Tech. Spec. limit 3.10E-02 3.70E-03
- 8. Iodines
- 1. Total iodine-131 C1 1.56E-03 1.93E-03
- 2. Average release rate for period uC1/sec 3.87E-03 5.27E-03
- 3. Percent of Tech. Spec. limit 6.20E-02 7.50E-02 C. Particulate
- 1. Particulate with T1/2 >8 days C1 3.67E-03 4.27E-03
- 2. Average release rate for period uC1/sec 4.30E-02 2.00E-02
- 3. Percent of Tech. Spec. limit 1.20E-04 9.90E-05
- 4. Gross alpha radioactivity Ci 5.01E-06 <1.00E-11 D. Tritium
- 1. Total release C1 1.02E+00 1.20E-03
- 2. Average release rate for period uCi/sec 1.30E-01 1.53E-04
- 3. Percent of Tech. Spec. limit 1.40E-03 1.60E-06
"<' indicates activity of sample is less than LLD given in uC1/ml l
i 8907110406 890703 l
{DR ADOCK 05000373 PDC E_--------_
.l r
LASALLE COUNTY NUCLEAR POWER STATION UNITS ONE AND TWO DOCKET NUNSERS 50-373 AND 50-374 ERRATA TO THE EFFLUENT AND WASTE DISPOSAL SENIANNUAL REPORT (1985)
GASEQUS EFFLUENTS-SUNNATION OF ALL RELEASES Third Fourth Quarter Quarter A. Fission and Activation Gases
- 1. Total release C1 1.02E+02-1.65E+01
- 2. Average release rate for period uCi/see 1.28E+01 9.67E+00
- 3. Percent of Tech. Spec. limit 8.00E-02 1.00E-03
- 8. Zodines
- 1. Total iodine-131 C1 4.30E-03 5.90E-04
- 2. Average release rate for period uC1/sec 1.33E-02 1.09E-02
- 3. Percent of Tech. Spec. limit 2.70E-03 2.40E-02 C. ? articulates 1.
Particulate with T1/2 >8 days Ci 5.35E-03 1.51E-03
- 2. Average release rate for period uCi/see 1.74E-01 1.86E-02
- 3. Percent of Tech. Spec. limit 4.80E-03 8.00E-05
- 4. Gross alpha radioactivity Ci 1.60E-08
<1.00E-11 D. Tritius
- 1. Total release Ci 7.10E-07 1.30E+00
- 2. Average release rate #or period uC1/sec 9.00E-08 1.67E-01
- 3. Percent of Tech. Spec. limit 9.50E-10 1.70E-03
"<" indicates activity of sample is less than LLD given in uC1/ml l
L b____________.___--____
l
1.
b.
L j
]
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT (1985)
GASEQUS EFFLUENTS-ELEVATED RELEASE Nuclides Released-January February March First Quarter
- 1. Fission Gases Ar-41 C1 1.50E+01 1.80E+01 3.00E+00 3.60E+01 Kr-85m Ci 1.50E+01
<1.00E-06 1.80E+00 1.63E+01 Kr-87 Ci
<1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Kr-88 Ci
<1.00E-06 <1.00E-06 <1.00E-06
<1.00E-06 Xe-133 C1 1.60E+01
<1.00E-06 1.70E-02 1.60E+01 Xe-133m Ci
<1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Xe-135 Ci
<1.00E-06 5.40E-01
<1.00E-06 5.40E-01 Xe-135m Ci
<1.00E-06 2.70E-04 5.00E-03 5.27E-03 Xe-138 Ci
<1.00E-06
<1.00E-06 <1.03E-06 <1.00E-06 Total for period C1 4.60E+01 1.85E+01 4.82E+00 6.93E+01
- 2. Iodines I-131 Ci 5.30E-04 4.50E-05 9.80E-04 1.56E-03 I-132 Ci 8.10E-04 2.00E-04 1.30E-03 2.31E-03 I-133 Ci 3.60E-03 8.60E-03 4.60E-03 1.68E-02 I-134 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 I-135 Ci 2.40E-03 5.20E-03 1.30E-03 8.90E-03 Total for period Ci 7.34E-03 1.40E-02 8.18E-03 2.96E-02
- 3. Particulate Mn-54 C1 1.20E-04 2.30E-04 2.00E-03 2.35E-03 Co-58 C1
<1.00E-04 1.00E-05 <1.00E-04 1.00E-05 Fe-59 C1 4.50E-05 <1.00E-04
<1.00E-04 4.50E-05 Co-60 Ci 5.00E-04 3.30E-04 3.90E-04 1.22E-03 Zn-65 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Sr-89 C1 2.90E-11 4.60E-11 4.00E-08 4.01E-08 Sr-90 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Mo-99 Ci (1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Cs-134 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Cs-136 Ci
<1.00E-04
<1.00E-04 1.00E-05 1.00E-05 Cs-137 Ci 1.90E-05 4.80E-15 1.60E-05 3.50E-05 La-140 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Ce-141 C1
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Ce-144 C1
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Total for period Ci 6.84E-04 5.70E-04 2.42E-03 3.67E-03
'<* indicates activity of sample is less than LLD given in uci/mi
(e l
i-ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT (1985)
GASEQUS EFFLUENTS-ELEVATED RELEASE Nuclides Released April May June Second Quarter
- 1. Fiesion Gases Ar-41 Ci 3.80E+00 <1.00E-06 <1.00E-06 3.80E+00 Kr-87 C1
<1.00E-06
<1.00E-06 <1.00E-06 <1.00E-06 Kr-88 Ci
<1.00E-06
<1.00E-06
<1.00E-06 <1.00E-06 Xe-133 Ci
<1.00E-06
<1.00E-06 <1.00E-06 <1.00E-06 Xe-133m Ci
<1.00E-06
<1.00E-06 <1.00E-06
<1.00E-06 Xe-135 Ci 3.60E+00
<1.00E-06 7.90E-02 3.68E+00' Xe-138 Ci
<1.00E-06
<1.00E-06
<1.00E-06 <1.00E-06 Total for period Ci 7.40E+00 (1.00E-06 7.90E-02 7.48E+00
<1.00E-11 2.10E-03 3.50E-03 I-133 C1 3.20E-03 6.00E-03 5.40E-03 1.46E-02 I-134 Ci
<1.00E-11 1.70E-03 7.80E-04 2.48E-03 1-135 Ci 4.10E-03 5.30E-03 7.00E-03 1.64E-02 Total for period Ci 9.03E-03 1.39E-02 1.60E-02 3.89E-02
- 3. Particulate 54 Ci 7.90E-04 1.30E-04 1.20E-03 2.12E-03 Co-58 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Fe-59 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Co-60 Ci 6.30E-04 2.20E-04 1.30E-03 2.15E-03 Zn-65 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Sr-89 C1 4.00E-08
<1.00E-11 4.00E-08 8.00E-08 Sr-90 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 Mo-99 Ci
<1.00E-04
<1.00E-04 <1.00E-04
<1.00E-04 Cs-134 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Cs-137 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 La-140 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00"-04 Ce-141 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Ce-144 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Total for period C1 1.42E-03 3.50E-04 2.50E-03 4.27E-03
'<* indicates activity of sample is less than LLD given in uci/ml
7 ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT (1945) i GASEQUS EFFLUENTS-ELEVATED RELEASE f
Huc11 des Released July August September Third Quarter
- 1. Fission Gases Ar-41 Ci
<1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Kr-85m Ci
<1.00E-06 8.60E-01
<1.00E-06 8.60E-01 Kr-87 Ci
<1.00E-06 <1.00E-05 <1.00E-06 <1.00E-06 K's-88 Ci
<1.00E-06 <1.00E-06 5.00E+01 5.00E+01 Xe-133 Ci
<1.00E-06 3.70E+01
<1.00E-06 3.70E+01 Xe-133m Ci
<1.00E-06 <1.00E-06 <1.00E-06 <1.00E-06 Xe-135 Ci 3.70E+00 4.30E-04 1.00E+01 1.37E+01 l
Xe-135m C.
<1.00E-06 1.00E-02 6.20E-03 1.62E-02 Xe-138 (i
<1.30E-06
<1.00E-06 <1.00E-06
<1.00E-06 Total for period
('i
- 3. 70E+00 3.79E+01 6.00E+01 1.02E+02
1 80E-03 1.10E-03 1.40E-03 4.30E-03.
I-132 C1
! 90E-03 4.10E-03 7.50E-03 1.35E-02 I-133 Ci
- 3. DOE-03 8.40E-03 1.00E-02 2.22E-02 I-134 Ci 6.70E-03 3.20E-03 4.10E-03 1.40E-02 I-135 C1 3.90E-03 9.20E-03 3.70E-02 5.01E-02 Total for perdad C1 1.81E-02 2.60E-02 6.00E-02 1.04E-01
- 3. Particulate Cr-51 Ci
<1.00E-04 4.70E-04
<1.00E-04 4.70E-04 Mn-54 Ci 3.00E-04 8.80E-05 1.40E-04 5.28E-04 Co-58 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Fe-59 C1
<1.00E-04 2.30E-05 <1.00E-04 2.30E-05 Co-60 Ci 7.00E-04 3.20E-03 3.70E-04 4.27E-03 2n-65 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Sr-89 Ci 3.50E-11 3.10E-11
<1.00E-11 6.60E-11
~4 90 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 db-95 Ci
<1.00E-04 1.70E-05 3.60E-05 5.30E-05 Mo-99 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Cs-134 Ci
<1.00E-04
<1.00E-04 cl.00E-04
<1.00E-04 Cs-137 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 La-140 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Ce-141 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Ce-144 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Total for period C1 1.00E-03 3.80E-03 5.46E-04 5.35E-03
"<* indicates activity o sample is less than LLD given in uci/ml
t
')&'
ERRATA TO THE EFFLUENT AND WASTE DISPOSAL REPORT-(1985F GASEQUS EFFLUENTS-ELEVATED RELEASE Nuclides Released October November December Fourth-Quarter
- 1. Fission Saoes Ar-41 Ci
<1.00E-06
<1.00E-06 <1.00E-06 <1.00E-06 Kr-85m aCi 2.40E-01
<1.00E-06 <1.00E-06 2.40E-01 Kr-87 Ci 5.20E-01
<1.00E-06 <1.00E-06
- 5. 20E Kr-88 Ci
<1.00E-06
<1.00E-06
<1.00E-06 <1.00E-06 Xe-133 Ci 1.30E+01
<1.00E-06
<1.00E-06 1.30E+01 Xe-133m Ci
<1.00E-06
<1.00E-06
<1.00E-06 <1.00E-06 Xe-135 C1 2.70E+00
<1.00E-06
<1.00E-06 2.70E+00 Xe-138 Ci- <2.00E-06
<1.00E-06
<1.00E-06 <1.00E-06 Total for period C1 1.65E+01
<1.00E-06
<1.00E-06 1.65E+01
<1.00E-11
<1.00E-11 5.90E-04' I-132 Ci 2.90E-03
<1.00E-11
<1.00E-11 2.90E-03 I-133 Ci 4.50E-03
<1.00E-11
<1.00E-11 4.50E-03 I-134 Ci
<1.00E-11
<1.00E-11
<1.00E-11
<1.00E-11 I-135 C1 4.50E-03
<1.00E-11 7.50E-02 7.95E-02 Total for period C1 1.25E-02
<1.00E-11 7.50E-02 8.75E-02
- 3. Particulate Mn-54 C1 1.80E-04 1.10E-04 1.10E-04 4.00E-04 Co-58 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E 04 Fe-59 Ci
<1.00E-04
<1.00E-04
<1.00E-04 -<1.00E-04 Co-60 Ci 6.6DE-04 3.40E-04 7.60E-05 1.10E-03 Zn-65 Ci (1. 0 3E-04 <1.00E-04
<1.00E-04
<1.00E-04 Sr-89 C1 1.8)E-11
<1.00E-11
<1.00E-11 1.80E-11 Sr-90 Ci 3.00E-12
<1.00E-11
<1.00E-11 3.00E-12 Mo-99 Ci
<1.0GE-04
<1.00E-04
<1.00E-04
<1.00E-04 L
Cs-134 C1 1.20E C5
<1.00E-OS
<1.00E-04 1.20E-05 L
Cs-137 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 l
La-140 C1
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Ce-141 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 Ce-144 Ci
<1.00E-04
<1.00E-04
<1.00E-04
<1.00E-04 f
Total for period C1 8.72E-04 4.50E-04 1.86E-04 1.51E-03 l
l
"<* indicates activity of sample is less than LLD given in uci/mi l
L___-_______-__________--___