Irof v5 CY (jO CONTAINMENT SYSTEMS 3/4.6.4 VACUUM RELIEF SUPPRESSION CHAMBER - DRYWELL VACUUM BREAKERS LIMITING CONDITION FOR OPERATION 3.6.4.1 All suppression chamber - drywell vacuum breakers shall be closed and at least 10 vacuum breakers shall be OPERABLE.*

l APPLICABILITY: OPERATIONAL CONDITIONS 1, 2, and 3.

ACTION:

a.

With one of the above required vacuum breckers inoperable for opening but known to be closed, restore the inoperable vacuum breaker to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

b.

With one or more suppression chamber - drywell vacuum breakers open, close the open vacuum breaker (s) within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

I With one of the position indicators of any suppression c.

chamber - drywell vacuum breakers inoperable, verify that all other vacuum breakers are closed within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and:

l 1.

Verify the vacuum breaker (s) witE the inoperable position indicator to be closed by demonstrating the other indicator to be OPERABLE within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and at least once i

per 14 days thereafter, or 2.

Verify the vacuum breaker (s) with the inoperable position indicator to be closed by conducting a test which demonstrates that the drywell-to-suppression chamber dP is maintained at greater than or equal to 0.5 psi for one hour without makeup within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and at least once per 14 days thereafter.

Otherwise, be in at least HOT SHUTDOWN within the next 12 l

hours and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

j l

d.

With one of the closed position indicators of one or more suppression chamber - drywell vacuum breaker (s) indicating open and the redundant closed position indicator indicating closed after a suppression chamber - drywell vacuum breaker opening as a result of a steam release, within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, cycle the applicable valve (s) to determine which of the redundant indicators is OPERABLE.

"The suppression chamber - drywell vacuun breakers may be-eenually opened for inerting the containment. All these vacuum breakers shallled1Qh3 closed h

position within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after inerting is completed.

FERMI - UNIT 2 3/4 6-48

l y

Ev4 t% puy L f

CONTAINMENT SYSTEMS 3/4.6.4 VACUUM RELIEF SUPPRESSION CHAMBER - DRYWELL VACUUM BREAKERS LIMITING CONDITION FOR OPERATION I

3.6.4.1 All suppression chamber - drywell vacuum breakers shall be closed and at least 10 vacuum breakers shall be OPERABLE.*

APPLICABILITY: OPERATIONAL CONDITIONS 1, 2, and 3.

j ACTION:

a.

With one of the above required vacuum breakers inoperable for f

opening but known to be closed, restore the inoperable vacuum j

breaker to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT 4

SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

b.

With one or more suppression chamber - drywell vacuum breakers open, l

close the open vacuum breaker (s) within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

c.

With one of the closed position indicators of one or more suppression chamber - drywell vacuum breaker (s) inoperable, verify the associated vacuum breaker and all other breakers to be closed within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, restore the inoperable position indicator to OPERABLE status within I

14 days or verify the vacuum breaker (s) with the inoperable position indicator to be closed by conducting a test which demonstrates that the drywell to suppression chamber AP is maintained at greater than or equal to 0.5 psi for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> without makeup within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and at least once per 15 days thereafter.

Otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the l?'!

following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

d.

With one of the closed position indicators of one or more suppression chamber - drywell vacuum breaker (s) indicating open and the redundant

'l closed position indicator indicating closed after a suppression j) chamber - drywell vacuum breaker opening as a result of a steam release, within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, cycle the applicable valve (s) to determine which of the redundant indicators is OPERABLE.

I I

l

  • The suppression chamber - drywell vacuum breakers may beaantrally opened for inerting the containment. All these vacuum breakers shallleimthe closed position within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after inerting is completed.

9 FERMI - UNIT 2 3/4 6-48 l