Forwards Safety Insp Repts 50-317/89-16 & 50-318/89-17 on 890710-13 & Notice of Violation
ML20246C376
Person / Time
Site: Calvert Cliffs  Constellation icon.png
Issue date: 08/15/1989
From: Bellamy R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Creel G
BALTIMORE GAS & ELECTRIC CO.
Shared Package
ML20246C381 List:
References
NUDOCS 8908240354
Download: ML20246C376 (2)


See also: IR 05000317/1989016

Text

-- - _ - _ - - _ _ _ _ _

V

,. .

?. ) j., .- /,

a

'

AUG 151989 h

Docket Nos.' 50-317. License Nos. DPR-53-

50-318 .DPR-69

Baltimore Gas 'and ' Electric Company -

2 ' ATTN: . Mr. George C. Creel

Vice President

Nuclear Energy

o, Calv9rt Cliffs ~ Nuclear Power Plant

MD Rts 2 & 4, P.O. Box 1535

~Lusby, Maryland 20657-

Gentlemen:

-Subject: Combined Ins'ection

p Report Nos. 50-317/89-16 and 50-318/89-17

A routine' safety inspection of your emergency preparedness program was

conducted by Mr..: C. Conklin on July 10-13, 1989 at your Ca'ivert Cliffs Nuclear

Power Plant,- Lusby, Maryland. Discussions of our findings were presented by

Mr. Conklin to Mr. Robert Denton and other members of your staff at the

conclusion of the inspection.

Areas examined.during this inspection are described in the NRC. Region I

Inspection' Report which is enclosed with this letter. Within these areas, the

inspection. consisted of selective examination of procedures and representative

records, interviews with personnel, and observations by the inspector.

Based upon the results of this inspection, it appears that certain of your

activities were not conducted in full compliance with NRC requirements, as set

forth in the Notice of Violation, enclosed herewith as Appendix A. This

violation has been categorized by severity level in accordance with the

" General Statement of Policy ~and Procedure for NRC Enforcement Actions", 10

CFR Part'2, Appendix C.(Enforcement Policy 1989). You are required.to respond

to this letter, and in preparing your response, you should follow the

instructions in Appendix A.

-The response directed by this letter and the accompanying Notice is not

subject to the clearance procedures of the Office of Management and Budget as

required by the Paperwork Reduction Act of 1980, PL 96-511.

iEIS5 4

t\

"0FRGAL RECOTS 30PT3

me2ggg ggggg ,

a

=_ _ _ _ _ _ __ _ _. _ _ . _ __ _i

_- _ -. .

,

yy

...

_

s I

Baltimore Gas:andi -2 - -

'

Electric Company AUG 151989 -

,

Your cooperation with us in this matter is appreciated..

m

Sincerely,

-@ hat signed By:

Tematd R. Delb 0Y ~

Ronald; R. - Bellamy, Chief

'

, Facilities Radiological Safety

and Safeguards Branch

. Division of Radiation-Safety

and Safeguards-

Enclosures:-

1. NRC Region I Combined Inspection Report Nos. 50-317/89-16 and

50-318/89-17.

- cc.w/ encl: . .. .. "

W. J. Lippold, General' Supervisor, Technical Services Engineering

~ T. Magette, Administrator, Nuclear Evaluations

- Public Document Room (PDR).

,

Local Public Document Room. (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State'of Maryland

bec w/ encl: .

.

Region I Docket Room (with concurrences)

>

Management Assistant, DRMA-(w/o encl)

' J. Wiggins, DRP

L'. Tripp, DRP

D. Limroth, DRP

S. McNeil, NRR j

l

Conklin Lazarus Be y

8//j/89 8/ 89 8 /89

0FFICIAL RECORD COPY

.

______:__-_______-_______----___-___-_-____-__-____--_____-__-__--________-_____. . _ _ _ - _ _ _ _ - _ _ _ - _ - - _ _ _ - - - - - _ - _ _ . _ -Q