______-_ _ _ _ _ _ - _ _ _ - _ _ - _.

l

/

4't UNITED STATES 8~

NUCLEAR REGULATORY COMMISSION 7;

\\,....../;E WASHINGTON, D. C. 20655 FEB 2s ta MEMORANDUM FOR: David L. Meyer, Chief Regulatory Publications Branch Division of Freedom of Information and Publications Services Office of Administration FROM:

Brenda Jo. Shelton, Chief j

Records and Reports Management Branch Division of Information Support Services Office of Information Resources Management

SUBJECT:

REQUEST FOR COMMENT / CONCURRENCE ON THE FINAL RULE, 10 CFR 50.62(c)(4), " FLOW CONTROL CONDITIONS FOR THE STANDBY LIQUID CONTROL SYSTEM IN BOILING WATER REACTORS" In response to your subject memorandum, the Records and Reports Management Branch (RRMB)providesthefollowing:

X The Paperwork Reduction Act statement is correct for the subject rule The Paperwork Reduction Act statement should be changed to statement number of the " Revised Paperwork Reduction Act Statements for i

Specif fe 3Ttuations".

Do not release the Federal Register Notice for publication until further notice.

X The Federal Register Notice can be released for publication.

Enclosed is a copy of the RRMB memorandum to the program office addressing our concerns with the subject rule.

A copy of the RRMB memorandum to the program office addressing our concerns with the subject rule will be forwarded at a later date.

,_ X An RRMB memorandum to the program office is not required.

1 e

/Brenda e

hief Records a d Reports Management Branch Division of Information Support Services Office of Infonnation Resources Management cc:

J. Mate, RES W. Pearson, RES fy50GjlB4890501 SO 54FR13361 PDR j'

Y\\J/

st

.$ ' N f

2

.l : Q

,U S 'y(V [

4 O

"A VQ n

l'

\\, /g yh DRAFT CONGRESSIONAL '.ETTER s

J

\\

N' Y

Dear ifr. Chairman:

l C

Enclosed-for-the-information-of--the-Committee on-is_a._ copy _of-a i

Federal Register notice of a final rule that sets forth conditions for determining the reactivity control capacity of boiling water reactor standby j

liquidcontrolsystems(SLCS). This rule is necessary to clarify the intent of an existing regulation.

l l

A proposed rule on this subject was published in the Federal Register on Monday, October 24,1988(53FR41607).

Sixty days were allowed for public comment.

One comment was received by the NRC, which agreed with the proposed

-clarification. The Commission believes that the proposed rele adequately clarifies reactivity control conditions for boiling water reactor SLCS, thus, the final rule adopts the proposed rule without modification.

This rule is clarifying in nature and does not constitute a significant I

question'of policy. The rule will become effective 30 days following its publication in the Federal Register.

Eric S. Beckjord, Director Office of Nuclear Regulatory Research 1

Enclosure a

7 d/$.y s

O')CKETf D USNRC REG'JLATORY r' S' T/f'?M DP J c1 /.)h.ya j; W zg)

'89 FEB 15 P 3 :26 Distribution:

[RA701 CONC /]

.subj-circ-chron Reading Files l

ESBeckjord TP5 pets-BMorris-ZRosztoezy TEcollins, NRR WLahs MWHodges, NRR JTelford-AWShepard, ADM WPearson SATreby, 0GC l

i.

- - - - - - -. -. ~. _ _ _ _ _ - - - - - - - - - - _ _ _ _ _ _ _ _ _

1 l

l l

Proposed Federal Register tiotice on Final Rule l

i 3

1 i

)

l

[7590-01)

NUCLEAR REGULATORY COMMISSION 10 CFR Part 50 Flow Control Conditions for the Standby. Liquid Control System in Boiling Water Reactors AGENCY: Nuclear Regulatory Commission.

ACTION:

Final rule.

SUMMARY

The NRC is amending its regulations to set forth conditions and considerations for determining reactivity control capacity for boiling water reactor standby liquid control systems.

The changes are necessary i

to clarify the existing regulation.

l EFFECTIVE DATE:

(Insert a date 30 days following publication in the Federal Register.)

, x,,a sad Y oe fu e 7 su 7kMmM' O* ' O lgt,,,v 4#'*rxa4 ' SUPPLEMENTARY INFORMATION:

On Monday, October 24, 1988, the Commission

% f,,,,,,, :n

]

/ published in the Federal Register (53 FR 4160,') a proposed rule, entitled

" Flow Control Conditions for the Standby Liquid Contrel System in Boiling f

Water Reactors," that proposed amendments to 10 CFR 50.62.

Interested parties wer,e invited to submit written comments within a 60-day comment ~

period, which ended on December 23, 1988.

One comment was received, which agreed with the proposed clarification.

i i

i l

1 1

4

p p,- gfs? 6s % V 5

u. (vdI
uf,u['/),Nr,% cL l

/

t n

., ~-

.n.

No change Jfr the proposed rule was suggested $ 'tlie'pu lic comment I-received by the NRC.

The Commission believes that the proposed rule adequately clarifies reactivity control conditions for boiling water reactor standby liquid control systems (SLCS), thus, a final rule is being issued adopting the proposed rule without modification.

Environmental Impact:

Categorical Exclusion l

The NRC has deternined that this rule is the type of action described as a categorical exclusion in 10 CFR 51.22(c)(2).

Thus, neither an environmental impact statement nor an environmental assessment has been I

prepared.

Paperwork Reduction Act Statement

=

This rule does not contain a new or amended information collection requirement subject to the Paperwork Reduction Act of 1980 (44 U.S.C.

3501 et seq.).

Existing requirements were approved by the Office of Management arid Budget under control number 3150-0011.

Lagulatory Analy:,is

!]-wie

/

e'this rule is of a clarifying nature and does not substantially change existing regulatory requirements, the regulatory analysis prepared l

for the final rule entitled " Reduction of Risk from Anticipated Transients Without Scram (ATWS) Events for Light-Water-Cooled Nuclear Power Plants,"

published June 26,1984 (49 FR 26036) is still valid for this rule.

The j

2 l

_ _ _ _ _,. _ _ -. - - - - - - - - - - - ~ ' - - - - - - - ' - " ' - ' - -

h 12590-01 f analysis is available for inspection in the Public Document Room, 2120 L Street NW., Washington, DC, Lower Level.

Single [opies of the analysis IC may be obtained from William R. Pearson, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission, Washington, DC 20555, telephone (301)492-3764.

i Regulatory Flexibility Act Certification In accordance with the Regulatory Flexibility Act of 1980 (5 U.S.C.

I 605(b)), the Commission certifies that this rule will not have a signifi-cant economic impact on a substantial number of small entities and that therefore a regulatory flexibility analysis is not needed.

This rule-making action affects only licensees that own and operate nuclear utili-zation facilities licensed under Sections 103 and 104 of the Atomic Energy Act of 1954, as amended.

These licensees do not fall within the definition of small businesses set forth in Section 3 of the Small Business Act (15 U.S.C. 632) or within the Small Business Size Standa set forth in the regulations issued for the Small Business Administration at 13 CFR Part 121.

Backfit Analysis The NRC has determined that the backfit rule, 10 CFR 50.109, does not apply to this rule, and therefore, that a backfit analysis is not required, because these amendments do not involve any provisions which i

impose backfits as defined in 10 CFR 50.109(a)(1).

3

]

.[7590<01 V List of Subjects in 10 CFR Part 50 1

Antitrust, Classified information, Fire ~ protection, Incorporation by reference, Intergovernmental)[ elations, Nuclear power plants and reac-b tors, Penalty, Radiation protection, Reactor siting criteria, Reporting and recordkeeping requirements.

For the reasons set out in the preamble and under the authority of the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974, as amended, and 5 U.S.C. 552 and 553, the NRC is adopting the following amendment to 10 CFR Part 50.

PART 50 - DOMESTIC LICENSING OF PRODUCTION AND UTILIZATION FAC

</

. /

1.

The authority citation for Part 50 continues to read as f,ollows:

(

9'd A HORITY:

Secs. 102, 103, 104, 105, 161, 182, 183, 186, 189 8 Stat.

I b;/[lA 4 V

i p

936, 93, 938, 948, 953, 954, 955, 956, as amended, sec 34, 83 Stat.

1244, as amen (42 U.S.C. 2132, 2133, 2134, 21

, 2201, 2232, 2233, 2236, 2239, 2282); s

. 201, as amended, 2, 206, 88 Stat. 1242, as amended, 1244, 1246 (42 U.

C. 5841, 5'

. 5846).

Section 50.7 also issued u Pub. L.95-601, sec.10, 92 Stat.

2951 (42 U.S.C. 5851).

Sect n 50.1 also issued under secs. 101, 185,-

68 Stat. 936, 955, as a ded (42 U.S.C.

31, 2235); sec. 102, Pub. L.91-190, 83 Stat. 85 (42 U.S.C. 4332).

Sectio 50.23, 50.35, 50.55, and 50.56, also is ed under sec. 185, 68 Stat. 955 (4

.S.C. 2235).

Sec-tions 50.3, 50.55a, and Appendix Q also issued under s. 102, Pub. L.91-190, 83 Stat. 853 (42 U.S.C. 4332).

Sections 50.34 and 50, 4 also i

ued und r sec. 204, 88 Stat.1245 (42 U.S.C. 5844).

Sections 50. 8, 4

e l

1 I

l PART 50 00NESTIC LICENSING 0F PRODUCTION AND UTIJIZATI'0N' FACILITIES--

~

s L 'cn-4N w :

1.

The authority citation for Part 50 is-revised-to read as follows:

AUTHORITY:

Secs. 102, 103, 104, 105, 161, 182, 183, 186, 189, 68 Stat. 936, 937, 938, 948, 953-954, 955, 956, as amended, sec. 234, 83 Stat.1244, as amended (42 U.S.C. 2132, 2133, 2134, 2135, 2201, 2232, 2233, 2236, 2239, 2282); cecs. 201, as amended, 202, 206, 88 Stat. 1242, as amended, 1244, 1246, (42 U.S.C. 5841, 5842, 5846).

Section 50.7 also issued under Pub L.95-601, sec. 10, 92 Stat. 2951 (42 U.S.C. 5851).

Sec. 50.10 also issued under secs. 101, 185, E8 Stat.

936, 955 as amended (42 U.S.C. 2131, 2235), sec.102, Pub. L.91-190, 83 Stat. 853 (42 U. 5,C. 4332).

Sections 50.13 and 50.54(dd) also issued under sec.108, 68 Stat. 939, as amended (42 U.S.C. 2138).

Sections 50.23, 50.35, 50.55, and 50.56 also issued under sec. 185, 68 Stat. 955 (42 U.S.C. 2235).

Sections 50.33a, 50.55a and Appendix Q also issued under sec.102, Pub. L.91-190, 83 Stat. 853 (42 U.S.C. 4332).

Sections 50.34 and 50.54 also issued under sec. 204, 88 Stat. 1245 (42 U.S.C. 5844).

Sections 50.58, 50.91 and 50.92 also issued under Pub. L.97-415, 96 Stat. 2073 (42 U.S.C. 2239).

Section 50.78 also issued under sec. 122, 68 Stat. 939 (42 U.S.C. 2152).

Sections 50.80-50-81 also issued under sec. 184, 68 Stat. 954, as amended (42 U.S.C. 2234).

Section 50.103 also issued under sec. 108, 68 Stat. 939, as amend (42 U.S.C. 2138).

Appendix F also issued under sec. 187, 68 Stat 955 (42 U.S.C. 2237).

VN

LIS 50.91, and 50.92 also issued under Pub. L.97-415, 96 Stat. 2073 (42 U. S..

).

Section 50.78 also 13 sued under sec.122, 68 Stat. 939 (42

}

.C.

2152).

ections 50.80-50.81 also issued under sec. 184, 68 5 954, as-amended (42 S.C.-2234).

Section 50.103 also issued er sec.108, 68 Stat. 939, as ended (42 U.S.C. 2138).

App ix F also issued under sec.187, 68 Stat. 955 2 U.S.C. 2237).

For the purposes of sec.

23, Stat. 958 as amend 2d (42 U.S.C.

l t

2273); SS 50.10(a), (5), and

),

44, 50.46, 50.48, 50.54 and 50.80(a) are issued under sec.

b, 68 Stat. 94,

s amended (42 U.S.C. 2201(b));

SS 50.10(b)'and and 50.54 are issued under

c. 161i, 68 Stat.949, as amended (42

.S.C. 2201(i)); and SS 50.9,50.55(e),5.

(b),50.70, 50.71,

.72, 50.73, and 50.78 are issued under sec.161o, 6 tat. 950, amended (42 U.S.C. 2201(o)).

a 2.

In S 50.62, paragraph (c)(4) is revised to read as follows:

S 50.62 Requirements for reduction of risk from anticipated transients without scram (ATW5) events for light-water-cooled nuclear power plants.

?

A A

A A

(c) ***

(4) Each boiling water reactor must have a standby liquid control I

system (SLCS) with the capability of injecting into the reactor pressure vessel a borated water solution at such a flow rate, level of boron con-centration and boron-10 isotope enrichment, and accounting for reactor f

pressure vessel volume, that the resulting reactivity control is at least equivalent to that resulting from injection of 86 gallons per minute of 13 weight percent sodium pentaborate decahydrate solution at the natural 5

rnciac' ira 1

d~

boron-10 Isotope abundance.into a 251-inch inside diameter reactor pres-sure vessel for a given core design.

The SLCS and its injection location must be' designed to perform its function in.a reliable manner.

The SLCS initiation must be automatic and must be designed to perform its function in a reliable manner for plants granted a construction permit after July 26, 1984, and for plants granted a construction permit prior to July 26, 1984, that have already been designed and built to include this feature.

A A

A A

A Dated at Rockville, Maryland, this day of

, 1989.

Victor Stello, Jr.

Executive Director for Operations i

i 6

l

l l

Federal Register Notice for the Proposed Rule l

l f

l l

i I

i l

W0 o.x14,t_)

RMassleser / Vol. 53 No. Aos / M-47. October 24, 1988 / N x d R aise 41ser read " forme 6ey be with the Plaat Protection and importad amaahamite: only":

and "asa nubestiyrtados will Quereettne Treatment Mansel. W sweetrassertAsty serosasavioes On inne be enterebinmaiensed to read Plant Protecuon and Quarantina 26,1984, no Cesnedselee publisbod h "for the plME mangbe iroported Treatment Li==ad is incorporated by the Federd Register (es PR anos4 a fhial !

inta the Ureitet.

reference. See i 300.1 of this chaptar.

r=la amtmind "Emdestion af Risk 8res Antlotpeted Dunalents Without Sasa

" Materials tacorpora ted by referenos."

5. In t aastynyyh(c)would if the treatment autborund by the Plant Nuclear] Power Maats," erid 3

be revisedtradmBuse Protection and Quarantine Treatment the regdstions la toCFR Part 38.&

Marmalis not availaWe. or if no finalrois required,at $ B&at (c)fmpoegegamithost authortsed treatment rfas= the okm bolling water reactors have a{c)(4), e treatmentjuGuisuddle may not be entered into the United stesutry Domin/ceaapatangradecedin States.

liquid controlsystma(Sl43 adth a 2

Mexico or&&hbaVblic may mial=mn Sow rete and baro

{

be enteredlengemstes Donein Wachington. DC thh 19th dey og equivalentin(reactMty(opetrel October.1ses, without: ^ 2;;bottworia 14ry s. stasle, d13 weightpacente sodium capacity to esgallone sainmer(spm) only if:

(t) The ausge&== the ActigAdministrosar, Asunoloadplaat pentaborale soladen.N rnie did not Dominicanagaandm under neoleImpeerfoo service, specify ee alas d the reactor pressure permit;

[m Doc. Mao Fihd 1&a-aa, us aml reasd(RPY)ladowhlch abis soleGoa (z)The e

  • 9 for should be Injected. Questions have been examinatiomipmhyserat the port

=q raised. especinHy fram licensees with a of arivalardinissteportof smallerRPV,comoeming the NUCLEAR REGUI.ATORY laterpmladon of 6e phrass. "eq*alat ernval until pector: 1 COMWSSM

) 1985, a genedeletler thei p (3)During i

December 3r,1&Lr -las is not e

movedintotammad 10 CTR Part 50 clasificatioo of this phrase wssIsaued to (4) DurlagligstmSNovernber 30 luclusive.amaammedinto flow ControlConditions for the appropdate licensees (PDit accession nomber asot290633). This lettar provided Alabama, AdamnEsiaCecryla.

StandbytJqdd ControlSysteinin the haofs for the flowrate and weidt l.ouisiana. Me** -A North 6o3000 Water Reactors percent of sodina pentaborate '

Camluu. SM1smenee, or AotNcy: Nuclear Regulatory decahydrue and described how ary part of h=n a % Miuouri.

Comnussloo.

equivalency coald be schiered for a er Virgmis svedesseparallel.

Ac noic Proposed rule.

smaller RPV.W staff considers the contenis of this leder, w6ich wers derived froei the ender matenals

~

8. In I stssgamed(d), the 8W N SP '

paragraph devismWWon)d be cons;dered when the 1sas TQ4 developed, so be AacL*may correct. The removed:"myuarumEbe redsed to read "maybegueCes";" port of @

sykm -

boer letteris appheeble aoSWas wie(1) arrival: "fuugdermalte gevked

{'[Q['*E"

,7 -.

volume of wetarla de supprewlos pool entry" wouldhaumuksend apart

  • '"""" **"8 g Per 88tStumN elcom pWWerandsed2l re acdyty en trol eys4emse, and (3) ", ore j

be

""8" bollwarm"!%g d are necessary to clad cHsting et be removed

I"I'U'A' to diNerug WW&au. N staff

y. In i 3195gpuy@(e),"may Daft: Comment ptriod expires.

proposes to clarify tkct age to more prectael enter" wouldlememin.and "may t e December 23,1988. Connments rece!ved besea. y reDect the ande technical taported !Nodd be after &ls date wS! be conaldered ifit is revised to resd%mmar entry" wouWammman,w"t of Pre::Ucal to do so, but aasurance of

& dandbyhdd contmlcysh i

and port of considerat!cn carmot be g!ven except as p)h dedgned het ee arrival"; andh would be to those comments rece!ved on or befors requirernents of general design criterion removed.

thisaste.

(GDC) number 26 of Appendix A to Part o

{.

8. la l 3195 ADDREssts: Mall written comments to
50. COC to states, Two independent wonld be adan%assepsagraph(f) rescUvity control systems of different numbstgows:

the Secretary: U.S. Nuciear Regulator 7 design principles shall be provided. One r.

Corninluloa, Washin6 ton DC 20556:

than)phd boh-ty,(f Treatmas#sprpstsother AT7N: Doclettag and Service Branch, of the systems shall use coetml roda, Deliver oorumenta to 11555 Rockville preferably including a positive means examination danapsedia Pike, Rockville, MD between 7:30 a m.

for insertin8 the rods, and abati be (e) of this seduumaycar)at theaccordance wa mugisk,(d), or and 4:15 p.m. weekdays. Copies of capable ofreliably controlling reactivity -

l s

comment received may be examined at changes to assure that onder ocodidons port of arrivde a p--ects, the NRC Public Document Room (PDR) of normaloperation, including other than thephtsa-iihat do at 2120 L Street NW, Washingtm, DC, anticipated operationaloccurrences, not exist in tiemma**--are not lowerlevd.

and with appropriate margins for widespread im&ensmate, the malfunctions such as rtuck toda, okra will ter*'"

try into ron nJnTHcm rnroRed AT)ON CONTACT' William R. pearson. Office of Nuclear specifled acceptsb!c fucIdesign fimits the United S" i tsted for Regulatory Research, U.S. Nucleer are not exceeded.& second reectMty the injurious * - - ' A '.1 Regulatory Commission, Weshington, tellably control!!ng the rete of rceed '

control system shall be capable of presence of ashipmamimazordance DC 20555, Telephone:(Mt) 492W64.

chenges resultiAg from planned, no 1

\\

l 41606 l

Federd agleter / Vd. 53. No. 205 / Monday, October 24, 1968 / Proposed Rules l

power changes (inclunganes 218 Inch inside diameter RPV provides definition of small businesses set forth c

i burnout) to assure accqestirlui reactivity control equivalent to the design limits are not exasM One of standard.

la Section 3 of the Sms!! Business Act the systems shall be capshirdholding If sodlum pentaborate decahydrate (15 UAC 632) or within the Small Winess Siza Standards set forth in the the reactor core subcrikalader cold solution enriched in the boron.10 (sotope regulations issued for the Small conditions."In the casedsW!ing is used. procedures should be Business Administration at 13 CFR Part water reactor, the setandmadivity established to assure proper disposal of 121.

control system la the Rin addition, the non. enriched solution and ensure the SLCS is used to re&cesid from that the boron 101sotope concentration Backfit Anal s!s I

ATWS.

In the new solution is sufficient to shut The SLCS consists dehd down the reactor.

The NRC has detennined that the containing the sodium;aderste backfit rule 10 CFR 50.109, does not decahydrate solution,taspamps.

Environinental Impa ct: Ca tegorical 8pply to this proposed rule, and Exclusion therefore, that a backfit enslysis la not con trol in s trum en ta tica appspria te piping, and means for tarugte system The NRC has determined that this required, because these amendments do without injecting the baatesolution into proposed rule is the type of action not involve any provisions which would the RPV, Sodium pentaletaar described as a categorical exclusion in impose backfits as defined in to CFR 50.109(a)(1).

decahydrate (NAaBw0.1tn0) solution 22(

)

u s' "

j ta e ent nor an Iht of Subjects In 10 CFR Part 50 ri ci d s o ved at envir nmentalassessment has been solution nominally is a13 a prepared.

AnUtrust, Classified informa tion. Fire percent solution of sodan;sht protection, incorporation by reference, ataborate decahydrate in which eeban.10 Paperwork Reduction Act Statement Intergovernmental rela tlons. Nuclea r isotope is at natural studance tabout us pr p sed rule does not catain a p wer plants and reactors. Penalty, r amended infonna tin coHecti" Radiation protection. Reactor siting 19.78%). A description of te!!LS and new its gunctions is given la theGescral requirement subject to the Paperwork criteria, Reporting and recordkeeping Electric Co. documenthEUa222 (80Reduction Act of 1960 (44 U.S.C 3501 et requirements' NEDO 21, Cla ss 1. February at1]'

seg ). Existing requirements were For the reasons set out in the entitled " Assessment oflMEtigation approved by the Office of Managemer.t preamble and under the authority of the of ATWS. Volume I(NtNIC.410S' and Budget under control number 3150-Atornic Energy Act of 1954, as amended, Allem a te No. 3)," sectiocs118.1.3, and 0011' the Energy Reorganization Act of1974, 7.2.10, Regulatory Analysis as amended, and 5 U.S.C 552 and 553, The important parametersla the NRCis proposing to adopt the teactivity control are the ccacentration Since this proposed rule is of a foUowing amendment to 10 CFR Part 50.

of the boron.10 isotope Wlhas a clarifying nature and does not arge thermal neutron captsucrow-substantially change existing regulatory PART 50-. DOMESTIC UCENSING OF section) in the RPV coormeuter and requirements, the regulatory smalysis PROOOCTiON AND UTILIZATION the time required to schWtis prepared for the final rule entitled FACiUTIES concentration. These pmackrs are in

" Reduction of Risk from Anticipated

1. The su!hortty citation for Part 60 turn dependent upon the pysolene Transients Without Scram (ATWS) continces to read as foDowr (and ti.erefore RPVinside Ameter). Eveats for Ught. Water-Cooled Nuclear Aatboetty: Secs. w tos. W. tos,161,1s2, boron injection flow rate,lorum solution Power P!snts," published June 26,1984 183.186.180. 68 Sta t. 936, 937, 938, 948, est, Concentration, and boroo-Mintpic (49 FR 20036)is atid valid and will be 954. 955. osa, as amended. sec. 234,83 Stat.

enrichrnent level. "Ihe etwind that is used for this rule. The analysla is 1M as amended (42 U.S C. 2132. 2133. 2134, specified in 4 50.62(c)(4Mspas of13 available for inspection in the Public 2115. 2 01,2232. 22n 223& 2239, 22s2h sees, weight percent sodiumpsisbarata Docume.:t Room. 2120 L Street NW.,

201, u amended. 202,20s, as Stat.1242 as solution) assumes a boro *Wsotopic Washingtcn, DC Lower Level. Single d,124.1248 82 U SC 5841,5842, a

Copies of the analysis may be obtained enrichment at the naturairmaning from William R. Pearson. Office of Section 50.7 also issued under Pub. L level and wss invnded biepesent the tc:ctivity control achievedkra BWR N ulear Regulatory Research, U.S.

9W1. sec.10, 92 Sta t. 2951 (42 U.S.C core design in a RPV withaskside Nuclear Regulatory Commission.

5851). Section 50.10 also issued under diameIer of 251 inches.Safetyanalyse Ws shington, DC 20553, telephone (301) s ecs.101,185. 68 Sta t. 938, 955, as 492-3764.

show however, that equinless amended (42 U.S.C 2131,2235); sec.102, reactivity controlis achievedbea given Regulatory Flexibility Act Certification Pub. L 91-190,83 Stat. 853 (42 U.S.C 4332). Sections 50.23,50.35,50.55, and core design in a different sizeIPV when in accordance with the Regulatory 50.56, also lasued under sec.185,68 Stat.

the same boron 101sotopecnacentration Flexibility Act of 1980 (5 U.S.C. 605(b)),

955 (42 U.S.C. 2235). Sections 50.33a, is provided within that RPV.thnce for a the Commission certifies that this rule,if 50 55s. and Append given core design. any coe&mtion of promulgated, will not have a significant under sec.102, Pub. L 01-190,83 Stat.

Injection rate, boron soletas economic impact on a substantial 853 (42 U.S.C. 4332). Sections 50.34 and concen tra tion level, boron-wsotopic number of small entities and that 50.54 also issued under sec. 204. 88 Stat.

enrich ment level, a nd RPVvalune that results in the same borons therefore a regulatory flexibility 1245 [42 U.S.C. 5844). Sections 50.58, analysis need not be prepared. This 50 91, and 5092 also issued under Pub. L concentra tion level within i.atRPV will rulemaking action would affect only 97-415,90 Stat. 2073 (42 U.S.C. 2239).

provide reactivity controlepinlent to licensees that own and operate nuclear Section 50.78 also issued under sec.122, the standard. For exarnple.M3spm of utilization facilities licensed under 68 Stat. 939 (42 U.S.C. 2152). Sections 28 weight percent sodiunipehborate sections 103 and 104 of the Atomic 50.80-50.81 also issued under sec.184. 68 solution enriched to twice $castural Energy Act of1954, as amended.These Stat. 954, as arnended (42 U.S.C 2234).

level of boron 10 contentioMdinto a licensees do not fall within the Section 50.103 also issued under sec.

I

e-=

l hhmingles.c / vol. ss. No. 30s / Monday, October24.1988 / ".T,pd Rules (100S 8018%aumends442 USC.Actiosc N.p.d rule: Extension of gg7, gg under stic.

coounent period-NATIONAL CRE0rT Um0N l

ADMINISTRATE 100f For the pv9medemaks9tet,ese a sussuAav:On August 23. Isee(53 FR l

d 'd N 8 E DS M ase(4 tb) 32000), the NRC published for pubGc NMM 8

d*dunitu al ses Me as of a y Mondeedminatbn Requtrenesets u

(ej and 50 0W 88 permits, etendard design certifications.

mm Stat. egg. u munddpgg"*'

W and combined construction pennits and Acasect.NationalCredit Union Il 30.s.sessM1hEhM4sL713n12, conditionaloperatinglicenses for Administration ("NCUN1 88J3. and geMeehndssarme,,seto S8et. 8M as s'addWisRaseyon., se nuclear power plants.He comment ACTt00c Raquest for commente.

period for this proposed role wee to sumuAnr.Section 701.31 of the NCUA 2.Ini30m, have expired on October 24.1968.

Rules and Regulations revised to read However. severe 1 organizations and

("Nondiscriminadon Requirements"l Cm 701.31) seems not to need m iSOM nogeesugigeseesteonetrisk individuals have requested, or have 8"h8 otherwise expreMed an Interest in, ao revision. Nevertheless. Se NCUA W 'udhout scram extension of the comment period.

Board, as part ofits regule tory review M

"*"8*8 Moreover, the agency faces certain Pohey. ngusts suggesdons on posah nocuar exigencies of Scheduling which did not irnprovemerits to this section.

I,,,

arise untilrecently. nerefore, balancing particularly ways to update or simplify bave) Es h bodingmertexfor mustthe desirability of developing a final rule 6e agulaum w make it mm casay H

  • "PN.* M'.b a standby $ sifeentrateyeten as soon as practicable against the needs I

"*I *O 9

h

)withtec.dalyofinjecting of commenters and the constraints of

""I" I 8

krate I'"""'*d 8 scheduling. the NRC ha: decided to 0 ATE: Comments must be receivedcaor extend the comment period for an beIm January 23,1968.

boEne'["""*'I 88 8 " 8

  • rate l "d

addiUonal fomteen days. ne extended ADoRESS: Send comments to Becky 1Oleolge eatinseland comment pedod now expires on Baker. Secretary of the Board. Na6 anal accounting fornaclapmee venel Novemg 7,1986.

Credit Union AdministraUon 1774 G volume, that thrnsdragreactivity 3

DATES:De comment petiod has been controlis at least sosialeam thatextended aad now expires on November FoR FURTHER fNFORsuTPON CONTACT:

te sulting frotn iajectise d Ngallons per 7.1988. Comrnents received after this H

M Ul f

minute of13 *tigkymasisodium pentabuste decalytair solabon at the date will be considered if prac6 cal to do Ce alCo e

a t te natural bwonMisa so, but only those commenta received on addren' or upkw @2$102. ~

a 251 inch In.sde a ge al=% lato or before this date can be amared of SUPPtf MENTARYINFOMMATeott Section

.or reactor cohh 701.31 of the NCUA Rules and pressure senelforog d

ne S!CS and th44uusehca Aconuses: Comments mey be eent to Regulations {12 CR 701.31) was be designed top reliable manner.erfunn as faction in a the Secretary of the Cecmdssim odstnally designed to summarize for

%rRC51mitiation Attention: Docketing and service FCU's in one pace the proWhitions on discrimination 1n real estale lending must be automaticedwge desi ned Branch U.S.NoclearRegulatory activities contained:in the Federal Falt to perfonnits farisisanEnble Cammiulon. Washlagion. DC 20555, or E

Housing Act [41 USC.3001 af seg.

ma rmer for pladts rauhd s eemtruction may be band-deliveted to One Wblie Department of Housing and Urban)and permit afte jaly B EBI.andforplants Flint North.11555 RockviDe Pike.

Development regulations issued granted a construeimpenpior to RockviDe MD 20832. between 7:30 am thereunder;in the EqualCredit July 28.1964 thatne'tateseybeen and 015 pm weekdays. Copies of ee Op ortunity Act (15 U.S.C.1801) and the designed and besttotetsdegge feature.

comments received may be examined at Fe ere1 Reserve Board's Regulation B the Commission's Pubhc Doa. ment (12 CFR 202.1.14) Issued thereunder.

Room at 2130 t, Street NW., WashIngtoa. and in certain major court ca of October tesaDefed at Rockvet.hrhnt h 12th day DC.between the hours of 733 em and in!"Preung h preens.ses Vidor Steno lr.

C13 pm weekdays.

ne NCUA Boardinvites comments

  1. N "Ia' FOR FVKTHER INFORMATtoft CONTACT:

on all aspects of the reguhtion, es-tusoFaedsa4k445 sm) i Steven Crockett. Attorney. Office of the particuledy' j

Ceneral Counsel. U.S. Nuclear 1.Whether the regulation has been a Regulatory Commission. Washington.

helpful resource for FCU's; 10 W DC 20555, telephone: (301) 492-1600.

2. Whether,if so, any parts of the -

regulation should be opdated, simplified.

Dated at P.ociviUe, MD thia 18th day of or made more easily comprehensible.

October 1988.

Early Site Permits;3tandardDe@nFor the Noclear Regulatory Commission.

Regulatory Procedures Certificatbns, and Coneheducenses Sameel l. Ch&.

for Nuc1 oat Power Reactors Secresaryofthe Cornmission, He request for comments makes no AcEucY:Noclear substantive changes to the current rule.

llence, neither a Regulatory Flexibility Commission.

IFR Doc. 86-2HW StW 8.45 arnl Analysis nor analysis under the euwa crw nmi.as Paperwork Reduction Actis required.

3

i l

i i

l l

i J

i 1

j

{

i i

i Draft Notice for the Daily Staff Notes i

i tC______.

DAILY STAFF NOTES OFFICE OF NUCLEAR REGULATORY RESEARCH Final Rule Signed by E00 On

, 1989 the Executive Director for Operations signed a' final rule that amends 10 CFR Part 50, " Domestic Licensing of Production and Utilization Facilities".

The rule clarifies conditions and considerations for determining the reactivity control capacity for boiling water reactor standby liquid control systems. This final rule adopts a proposed rule, which was' published

'in the Federal Register (53 FR 41607) on itonday, October 24, 1988, without modification.

This notice informs the Commission that, in accordance with the rulemaking authority' delegated to the E00, the E00 has signed this final rule and proposes to forward it on

, 1989 to the Office of the Federal Register for publication, unless otherwise directed by the Commission.

l

7--__-.

Draft Congressional Letter i

1 i