ML20245L442

From kanterella
Jump to navigation Jump to search
Supplemental Application for Amends to Licenses NPF-35 & NPF-52,changing Unit 1 License Condition 16 & Unit 2 License Condition 10 Re Steam Generator PORVs in Steam Generator Tube Rupture Analysis
ML20245L442
Person / Time
Site: Catawba  
Issue date: 06/28/1989
From: Tucker H
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20245L446 List:
References
NUDOCS 8907050498
Download: ML20245L442 (2)


Text

-

g

.y 9,

1*

js.

- Dunn POWER GOMPAhT P.O. Box 33189 i

CHARLOTTE, N.C. 28242 1HALH. TUCKER reternown.

O vmm renament

.(704) o73-4531 b.

' avos. nam raonwmon -

L-i:

~

June'28, 1989 k

.U.HS. Nuclear' Regulatory Commission l

. Attention: ~ Document Control Desk Washington,'D.'C. 20555

Subject:

Catawba Nuclear Station, Units 1 and 2 Docket Nos. 50-413 and 50-414 License Conditions 16 (Unit'1) and 10 (Unit 2) SGTR Technical Specification Amendment Steam Generator Tube Rupture Analysis

Dear Sir:

' This letter contains a revised proposed Technical Specification for' Catawba's Steam Generator Power Operated Relief Valves (PORVs). This change supersedes

. the proposed Technical Specification in my letter dated June 12, 1989.. However, the Bases and.the No Significant Hazards Analysis referenced'in my June 12, 1989 letter submitted by letters of December 4, 1987 and December 11, 1987 remain valid.. Also, the FSAR, analysis submitted with my August 24, 1988 letter remains unchanged.

- The changes to the proposed Technical Specification for the PORVs submitted on June.12, 1989 are to ensure the action statement requires a unit to be placed in a mode-that the Limiting Condition For Operation does not apply. Specifically, the requirement to continue to Hot Shutdown and place the Residual Heat Removal g

System.in service has been added to the Action statement.

~ Pursuant to 10 CFR 50.91 (b) (1) the appropriate South Carolina State Official is being provided a copy of this amendment request.

Very truly yours, h )#

p W

flal B. Tucker Aool

. PGL/IV/47A Attachments 8907050498 890629 DR ADOCK 05000413 PNV

-o-i h_m__.

______..__._._m_

V

U. S. Nuclear Regulatory Commission June 28, 1989 Page Two xc:

Mr. S. D. Ebneter, Regional Administrator

-U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. Heyward Shealy, Chief Bureaulof Radiological Health South Carolina Department of Health &

Environmental Control 2600 Bull Street Columbia, South Carolina 29201 American Nuclear Insurers c/o Dottie Sherman, ANI Library The Exchange, Suite 245 270 Farmington Avenue Farmington, CT 06032-M&M Nuc1 car Consultants 1221 Avenue of the Americas New York, New York 100^1 INPO Records Center i

Suite 1500 l

1100 Circle 75 Parkway Atlanta, Georgia 30339 Mr. W. T. Orders NRC Resident Inspector Catawba Nuclear Station 1

i

_ _. _ _ _ _.. _ - _