Corrected Proposed Tech Specs Paragraph 3.7 Re Containment Sphere Leakage Testing
ML20245K699
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 06/30/1989
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Shared Package
ML20245K683 List:
References
NUDOCS 8907050223
Download: ML20245K699 (2)


Text

__

ATTACHMENT Consumers Power Company Palisades Plant Docket 50-255 a

TECHNICAL SPECIFICATION CHANGE REQUEST CONTAINMENT SPHERE LEAKAGE TESTING June 30, 1989 1 Page OC0689-0011-h102 8907050223 890630 PDR ADOCK 05000155 P

PDC

~

10 3.7 (Contd)

. leakage rate shall yield an overall leakage rate not greater than 0.5%/ day at 27 psig.

(d) A containment sphere integrated leakage rate test shall be

/

performed at a pressure not less than 11.5 psig in conformance with

/

the criteria specified in Appendix J of 10 CFR 50.

Three tests

/

shall be conducted at 40 t 10 month intervals during each 10-year

/

service period.

/

(e) If any containment' sphere integrated leakage rate test (ILRT) fails

/

to meet the specifications of 0.5%/ day of contained atmosphere

/

'(weight basis) at the design pressure (27 psig) or extrapolated to

/-

the design pressure, the test schedule for subsequent ILRTs shall

/

be reviewed and approved by the Commission.

If two consecutive

/.

ILRTs fail to meet these specifications, then an ILRT shall be

/

performed at least every 13 months until two consecutive ILRTs meet

/

the' acceptance criteria, at which time the above test schedule may

/

be resumed.

(f) The accuracy of each ILRT shall be verified by a supplemental test

/

in accordance with Appendix J of 10 CFR 50 which confirms the

/

accuracy of the test by (1) verifying the difference between the

/

supplemental test data and the ILRT is within 0.25 L or 0.25 L '

/

s t

(2) continuing the test for a duration sufficient to establish

/

accurately the change in leakage rate between the ILRT and

/

supplementati test.

/