Forwards SER Accepting Corrective Actions Taken in Response to Plant 890120 High Pressure Injection Sys Backflow Event. TAC 71972 Considered Closed
ML20245K360
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/11/1989
From: Craig Harbuck
Office of Nuclear Reactor Regulation
To: Tison Campbell
ARKANSAS POWER & LIGHT CO.
Shared Package
ML20245K366 List:
References
TAC-71972, NUDOCS 8908180424
Download: ML20245K360 (3)


Text

{

i

~^*

August 11, 1989 Docket No. 50-313 Mr. T. Gene Campbell Vice President, Nuclear Arkansas Power and Light Company Post Office Box 551 Little Rock, Arkansas 72203

Dear Mr. Campbell:

SUBJECT:

SAFETY EVALUATION OF THE CORRECTIVE ACTIONS TAKEN IN RESPONSE TO THE ARKANSAS NUCLEAR ONE, UNIT 1, JANUARY 20, 1989, HIGH PRESSURE INJECTION SYSTEM BACKFLOW EVENT (TAC NO. 71972)

The staff has completed its review of the corrective. actions you have taken in response to the Unit I high pressure injection system backflow event of January 20, 1989. This review was based primarily upon information which you provided in submittals dated February 14 and 24, and April 27, 1989.

It focused on the areas which were pertinent to the assessment of damage to the affected high pressure injection piping and to your corrective actions to prevent recurrence. The staff has concluded that your corrective actions were adequate.

TAC No. 71972 is therefore considered completed based upon the enclosed Safety Evaluation.

Sincerely,

/s/

C. Craig Harbuck, Project Manager Project Directorate IV Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

See next page DISTRIBUTION E Docket Filed NRC PDR Local PDR PD4 Reading G. Holahan ADR4 F. Hebdon P. Noonan C. Harbuck OGC-Rockville E. Jordan B. Grimes ACRS (10)

D. Chamberlain, RIV L. Marsh, EMEB R. Li, EMEB PD4 Plant File

/

tPD4/LA PD4/PM M PD4/D4).

Of0/

s PNoonan CHarbuck:sr FHebdon 08/ ll /89 08/H /89 08/l(/89 1

8908180424 090811 PDR ADOCK 05000313 P

PNU

I

,(

'g UNITED STATES y

p, NUCLEAR REGULATORY COMMISSION 7,,

E t

WASHINGTON, D. C. 20555 l

%g

  • s s + +

u August 11, 1989 Docket No. 50-313 l

1 Mr. T. Gene Campbell

)

Vice President, Nuclear Arkansas Power and Light Company Post Office Box 551 Little Rock, Arkansas 72203 l

Dear Mr. Campbell:

SUBJECT:

SAFETY EVALUATION OF THE CORRECTIVE ACTIONS TAKEN IN RESPONSE TO THE ARKANSAS NUCLEAR ONE, UNIT 1, 1

JANUARY 20, 1989 HIGH PRESSURE INJECTION SYSTEM j

BACKFLOW EVENT (TAC NO. 71972) 4 i

The staff has completed its review of the corrective actions you have taken in I

response to the Unit I hich pressure injection system backflow event of January 20, 1989. This review was based primarily upon information which you t

provided in submittals dated February 14 and 24, and April 27, 1989.

It focused on the areas which were pertinent to the assessment of damage to the affected high pressure injection piping and to your corrective actions to prevent recurrence. The staff has concluded that your corrective actions were adequate.

TAC No. 71972 is therefore considered completed based upon the enclosed Safety Evaluation.

Sincerely, I

M C. Craig Harbuck, Project Manager Project Directorate IV Division of Reactor Projects - III, j

IV, Y and Special Projects Office of Nuclear Reactor Regulation

Enclosure:

1 As stated

)

i cc w/ enclosure:

See next page r

-________--__--__-__--______:_L l

1

.G.

I 4

Mr. T. Gene Campbell Arkansas Power & Light Company Arkansas Nuclear One, Unit I cc:

Mr. Early Ewing, General Manager

_ Technical Support and Assessment l-Arkansas Nuclear One 1

l P. 0. Box 608 l

Russellville, Arkansas 72801 l

1 l

Mr. Niel.Carns, Director Nuclear Operations Arkansas Nuclear One P. O. Box 608 l

Russellville, Arkanses 7280)

Mr. Nicholas S. Reynolds Bishop, Cook, Purcell & Reynolds l

1400 L Street, N.W.

Washington, D.C.

20005-3502 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division 1700 Rockville Pike, Suite 525 Rockville, Maryland 20852 Senior Resident Inspector U.S. Nuclear Regulatory Commission 1 Nuclear Plant Road Russellville, Arkansas 72801 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Office of-Executive Director for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Honorable Joe W. Phillips

)

County Judge of Pope County

)

Pope County Courthouse Russellville, Arkansas 72203 Ms. Greta Dicus, Director i

Division of Environmental Health j

Protection Arkansas Department of Health i

4815 West Markam Street Little Rock, Arkansas 72201 l

l