Forwards Safety Evaluation Approving Util 890519 Request to Restart Facility,Per NRC Review of Util Steam Generator Insp Program & Accepting 890528 Response to NRC Bulletin 89-001 Subj to Noted Clarifications in Conclusion
ML20245J831
Person / Time
Site: North Anna 
Issue date: 06/28/1989
From: Engle L
Office of Nuclear Reactor Regulation
To: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
Shared Package
ML20245J835 List:
References
IEB-89-001, IEB-89-1, TAC-72261, NUDOCS 8907030185
Download: ML20245J831 (2)


Text

_ _ _ _ _ _.

9 June 28, 1989 Docket No. 50-338 DISTRIBUTION tDocketaFile #

DMiller NRC & Local PDRs LEngle PDII-2 Reading OGC (info.only)

SVarga EJordan Mr. W. R. Cartwright GLainas BGrimes Vice President - Nuclear HBerkow ACRS(10)

Virginia Electric and Power Company BSinkule, R-II 5000 Dominion Blvd.

Glen Allen, Virginia 23060

Dear Mr. Cartwright:

SUBJECT:

SAFETY EVALUATION, ACTIONS RELATING TO STEAM GENERATOR TUBES AND PLUGS, NORTH ANNA UNIT 1 (NA-1) (TAC N0. 72261)

By letter dated May 19, 1989, you requested that the NRC staff approve restart of North Anna Unit 1 regarding the subject as noted above. NRC staff approval is required pursuant to the plant Technical Specifications (TS) since results of steam generator tube inspections performed during the current refueling outage were found to be category C-3 (as defined in the TS).

The staff has completed the review of your steam generator inspection program and the results thereof and concludes that there is an adequate basis to approve restart for NA-1.

Our safety evaluation (SE) is enclosed. As noted in the SE, the staff is continuing to evaluate whether hA-1 can be operated until the next refueling outage before the steam generators receive their next inspection.

Finally, the enclosed SE addresses your May 28, 1989 response to Bulletin 89-01,

" Failure of Westinghouse Mechanical Steam Generator Tube Plugs." We find your response to be acceptable subject to the clarification noted in the conclusions of the enclosed SE.

Sincerely, Original signed by Leon B. Engle, Project Manager Project Directorate II-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation

Enclosure:

g As stated l'I I

1 cc w/ enclosure:

See next page j

l 1

[NA-1 SE STEAM GENERATOR LTR]

fS (4:)q$2 P

2 D:PD DMiltr LES d

Hder vr' 06/p89 06/ /89 06/4/89 8907030185 890628 I

PDR ADOCK 05000338 t

Q FDC

L Mr. W. R. Cartwright North Anna Power Station Virginia Electric & Power Company Units 1 and 2 cc:

Mr. William C. Porter, Jr.

C. M. G.- Buttery, M.D., M. P.H.

County Administrator Department of Health Louisa County 109 Governor Street P.O. Box 160 Richmond, Virginia 23219 Louisa', Virginia 23093 Regional Administrator, Region 11 Michael W. Maupin, Esq.

U.S. Nuclear Regulatory Commission Hunton and Williams 101 Marietta Street N.W., Suite 2900 P. O. Box 1535 Atlanta, Georgia 30323 Richmond, Virginia 23212 Mr. W. T. Lough Virginia Corporation Commission Mr. G. E. Kane Division of Energy Regulation P. O. Box 402 P. O. Box 1197 Mineral, Virginia 23117 Richmond, Virginia 23209 Old Dominion Electric Cooperative c/o Executive Vice President Innsbrook Corporate Center 4222 Cox Road, Suite 102 Glen Allen, Virginia -23060 Mr. W. L. Stewart Senior Vice President - Power Virginia Electric and Power Co.

Post Office Box 26666 Richmond, Virginia 23261 Mr. Patrick A. O' Hare Office of the Attorney General Supreme Court Building 101 North 8th Street Richmond, Virginia 23219 Resident Inspector / North Anna c/o U.S. NRC Senior Resident Inspector Route 2, Box 78 Mineral, Virginia 23117

.