August 11, 1989 Docket No. 70-125f License No. SNM-1227 Amendment No. 4 Advanced Nuclear Fuels Corporation ATTN: Mr. C. W. Malody, Manager Corporate Licensing 2101 Horn Rapids Road Richland, Washington 99352-0130 Gentlemen:
In accordance with your application dated April 1,1989 (submitted by letter dated March 30,1989), and pursuant to litle 10, Code of Federal Regulations, Part 70, Materials License No. SNM-1227 is hereby amended to revise the pos-session limits and to include the date of the revised Radiological Contingency Plan.
Accordingly, Condition 9 is amended to include the date of April 1,1989, and Conditions 6, 7, and 8 are revised as follows:
Material Form Quantity 6.A. Uranium enriched 7.A. Any 8.A. 100 g U-235 in U-235 6.B. Uranium enriched from 7.B. Uranium 8.B. 9,500 g U-235 10.00 up to 19.99 w/o compounds U-235 6.C. Uranium enriched from 7.C. Uranium 8.C. 200 kg U-235 5.01 up to 9.99 w/o compounds U-235 6.D. Uranium enriched up to 7.D. Uranium 8.D. 20,000 kg U-235 5.00 w/o U-235 compounds L
6.E. Plutoniuri 7.E. Sealed sources 8.E. I mg Pu 6.F. Plutonium 7.F. Pu0 -U0 E.F. 500 g Pu stofedhaste This authorization is subject to the following new condition:
12.
Pege 7-7 of the amendment application dated April 1,1989, is not incorporated into the license. Page 7-6 dated July 1987, remains in effect.
j i
All other conditions of this license shall remain the same.
This action was initiated, in part, by the Division of Safeguards and Transportation, HMSS, af ter recognizing that the authorized possession limit 8908170D72 890811 4
PDR ADOCK 07001257 C
FDC
Advanced Nuclear Fuels Corporation 2
August 11, 1989 for uranium piaces Advanced Nuclear Fuels (ANF) in the Category II classifica-tion for material control and accounting (MC&A) purposes. The amendment is necessary to permit ANF to remain in the MC&A Category III classification.
{
Based on our review of the revisions to your Radiological Contingency Plan, we agree with your conclusion that these changes do not decrease the response j
effectiveness of the Plan. This amendment is issued for the convenience of i
the Commission to maintain up-to-date references to the Plan in your license.
Based on our review of the proposed revision to the decommissioning plan, we conclude that your financial assurance commitment for decommissioning does not i
satisfy the requirements of 10 CFR 70.25. By separate correspondence, we will provide you with guidance on financial assurance mechanisms required for decommissioning under this regulatier, 3
j i
Please ente that Condition 8.E. in the revised license enclosed with Amendment I
No. 3 er' oneously stated a quantity lir.it of 1 mg Pu. This error is corrected r
in Condition 8.F. of the enclosed revised license.
Revised License No. SNM-1227 and our Safety Evaluation Report are enclosed.
1 FOR THE NUCLEAR REGULATORY COMMISSION t
Original Signed By l
Leland C. Rouse, Chief Fuel Cycle Safety Branch Division of Industrial and 1
Medical Nuclear Safety, NMSS
Enclosures:
1.
Revised License No. SNM-1227 2.
Safety Evaluation Report Distribution w/ enc?s Docket No.-70 1E57 PDR(
fNRC File Centeri NHSS R/F IMUF R/F
'IMSB R/F
~VLTharpe SPennington(2)
Region V CHooker, RV DWeiss, LFMB RGramann, SGIB DJKasun, SGDB SHO MLHorn GHBidinger
[
h.......______[
_____...I.
IS_ Yt....[
i NAME:SPenningtop:mh
- VLTharpe
- GHBidinger
- LCRouse IATE:8/9 /89
- 8/A/89
- 8/P/89
- 8/// /89 0FFICIAL RECORD COPY I
_ _ _ _ _ _