April 13,:1989

-U.'S. Nuclear Regulatory Commission Attn:. Document Control Desk l

Washington, D.C.

20555

Subject:

McGuire Nuclear Station, Unit 1 Docket No. 50-369

.I Valve IND-34 Technical Specifications 4.0.5, 3/4.4.1.4

-Relief From Tech. Spec./ASME Code Surveillance / Testing Requirement Gentlemen:

McGuire Unit 1 Residual Heat Removal (ND) system valve IND-34'(ND Heat Exchanger Bypass)'is included in the McGuire Nuclear Station 10 CFR 50.55a(g) IWP/IWV Pump and Valve Inservice Testing (IST) Program, for which periodic testing is required i

pursuant to Technical Specification Surveillance Requirement 4.r: 5.. Although the IST. program specifies quarterly testing for this valve, it was ;taced on a monthly surveillance interval in accordance with IWV requirements due to erratic valve stroke times. Accordingly, this valve was due to be tested March 31, 1989,

-with a late date'(includes the grace period specified by T.S.4.0.2) of April 7, 1989.

McGuire Unit 1 was and is in mode 5 on mid-loop operation for steam generator-tube work (ref. Licensee Event Report No. 369/89-04). We did not want to cycle any valve that could affect mid-loop operation and potentially cause a loss of ND.

T.S.3.4.1.4 requires 2 loops of ND to be operable in Mode 5 and a missed surveillance would have required the ND system to be declared inoperable. This situation was discussed in a telecon between Mr. P. B. Nardoci et.al (DPC) and Mr..D. S. Hood (NRC/0NRR) on April'4, 1989, and Mr. Hood agreed that te. sting the valve.while in mid-loop operation would not be prudent and stated that the

. surveillance of IND-34 may be delayed until the unit is off of mid-loop operation (this will not be considered as a missed surveillance).

This letter constitutes documentation of the April 4th telecon and surveillance deferral per the request of Mr. Hood. The valve will be tested once the unit is no longer on mid-loop operation.

I would like to express my appreciation for the NRC's timely cooperation in this matter. Should there be any questions or if additional information is required, please advise.

Very truly yours, Di r

Ha B. Tucker PBN161/1cs I

8904260367 890413 ADOCK0500g9 DR

e U. S.. Nuclear' Regulatory Commission Page 2 April 13, 1989 xc:

Mr. S. D. Ebneter Regional Administrator U.S. Nuclear Regulatory Commission Region II 101 Marietta St., N.W., Suite 2900 Atlanta, Georgia 30329 Mr. P. K. Van Doorn NRC Resident Inspector McGuire Nuclear Station Mr. D. S. Hood Project Manager Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.