_

.g'-

, ' * 'y..

April 6, 1989 i

Docket No.'50-353 Mr. George A. Hunger, Jr.

Director-Licensing Philadelphia Electric Company

-)

Correspondence Control Desk P. O. Box'7520 Philadelphia, Pennsylvania 19101

Dear Mr. Hunger:

SUBJECT:

PRE-SERVICE INSPECTION PROGRAM (TAC NO. 66831)

I RE:

LIHERICK GENERATING STATION, UNIT NO. 2 We have completed our review of your submittal of March 31, 1989 requesting approval for.the. use of four ASME Code Cases in the Limerick, Unit 2 Pre-service.

Inspection. Program, which you submitted January 3, 1989. You are hereby granted NRC approval for the use-of ASME Code Cases N307, N356, N435 and N460 for the PSI Program.

Sincerely,

' Original signed by Richard J. Clark Richard J. Clark, Project Manager Project Directorate I-2 l'

Division of Reactor Projects I/II Office of Nuclear Reactor Regulation j.

cc: See next page DISTRIBUTION:

.$LDocRetJ11ey NRC PDR/LPDR" PDI-2 Reading EJordan/BGrimes Fp[

o GJohnson i

RHermann C.Y. Cheng

/

l RClark/RMartin SVarga/BBoger

-OGC-ACRS (10)

[HUNGERLETT]

  • Previously concurred PDI-2/PM*

PDI-2/D EMTB*

EMTB*

C/EMTB*

RClark:tr WButler GJohnson RAHermann CYCheng 04/05/89 g/g/89 04/05/89 04/05/89 04/06/89 890421007s s90406

i l

JP R ADOCK 05000353 Y

PNU l

C j

dasco o,,

UNITED STATEc 8

NUCLEAR REGULATORY COMMISSION o

h N

WASHINGTON, D. C. 20555 -

8

%,****,o April 6, 1989 q

Docket No. 50-353 I

Mr. George-A. Hunger, Jr.

Director-Licensing Philadelphia Electric Company Correspondence Control Desk P. O. Box 7520 Philadelphia, Pennsylvania:. 19101

.,I

Dear Mr. Hunger:

SUBJECT:

PRE-SERVICE INSPECTION PROGRAM (TAC NO. 66831)

RE:

LIMERICK GENERATING STATION, UNIT NO. 2 We have completed our review of your submittal of March 31, 1989 requesting'-

approval for the use of four ASME Code Cases in the Limerick, Unit 2 Pre-service Inspection' Program, which you submitted January 3,1989.

You are hereby granted NRC approval for the use of ASME Code Cases N307, N356, N435 and N460 for the PSI Program.

Sincerely, d_ _. -

c

. Cl rk, Project Manager roject Dire torate I-2 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation cc: See next page

fm

~ f[

Mr!'hNorgeA.'H'unger,Jr..

Limerick Generating Station Philadelphia Electric Company Units 1 & 2

.:V

+

7 cc:

Troy B. Conner, Jr., Esquire Mr. Robert Gram Conner and Wetterhahn Senior Resident' Inspector.

1747 Pennsylvania Ave., N.W.

U.S. Nuclear Regulatory Connission Washington, D. C.

20006.

P.;0. Box'596' Pottstown, Pennsylvania 19464 Mr.' Rod Krich S7-1

! Philadelphia Electric Company.

Mr.' Ted Ullrich 2301 Market Street Manager - Unit 2 Startup Philadelphia ~, Pennsylvania' 19101 Limerick Generating Station a

P. 0.-Box A Mr. David' Honan N2-1

.Sanatoga, Pennsylvania 19464 Philadelphia Electric Company

'2301 Market Street.

Mr. John Doering Philadelphia, Pennsylvania' 19101 Superintendent-Operations

. Limerick Generating Station 1

Mr. Graham M. Leitch Vice President cP. O. Box A-

. Limerick Generating Station Sanatoga, Pennsylvania 19a64-Post Office Box <A.

Sanatoga, Pennsylvania: 19464 Thomas Gerusky, Director-Bureau of Radiation Protection PA Dept. of Environmental Resources Mr. James Linville P. O. Box 2063 U.S._ Nuclear Regulatory Commission-Harrisburg,. Pennsylvania 17120' Region:I

-475 Allendale Road Single Point of Contact

. King-of Prussia, ' PA.19406 P. O. Box 11880 Harrisburg, Pennsylvania 17108-1880 Mr. Thomas Kenny' Senior Resident Inspector.

Mr.' Philip J. Duca US Nuclear Regulatory Comission.

Superintendent-Technical P.

0.' Box 596 Limerick Generating Station Pottstown, Pennsylvania. 19464 P. O. Box A Sanatoga, Pennsylvania.19464

.c Mr. Joseph W. Gallagher Vice President, Nuclear Services Philadelphia Electric Company a

2301 Market Street Philadelphia, Pennsylvania 19101 Mr. John S. Kemper Senior.Vice President-Nuclear-Philadelphia Electric Company 2301' Market Street-Philadelphia, Pennsylvania 19101 I

I

!