ML20237K637

From kanterella
Jump to navigation Jump to search
Informs That Review of Rev 9 to Emergency Plan Complete. Changes Contained in Rev Found to Be Consistent W/Stds of 10CFR50.47(b) & Requirements of App E to 10CFR50
ML20237K637
Person / Time
Site: Catawba  Duke Energy icon.png
Issue date: 08/14/1987
From: Dan Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Tucker H
DUKE POWER CO.
References
NUDOCS 8708270237
Download: ML20237K637 (1)


Text

. _. _ - _ -

- AUG 141987

)

n Docket Nos. 50-413, 50-414 License Nos. NPF-35, NPF-52 i

Duke Power Company ATTNLdr. H. B. Tucker, Vice President

. Nuclear Production Department 422 South Church Street

. Charlotte. NC : 28242

. Gentlemen:

SUBJECT:

DOCKET N05. 50-413 AND 50-414

. CATAWBA NUCLEAR STATION EMERGENCY' PLAN REVIEW We have ' completed our review. of Revision 9 of the Catawba Nuclear Station Emergency Plan.

The review indicated that the changes contained in ' this revision are consistent with the planning standards of 10 CFR 50.47(b) and the requirements.of Appendix E to 10 CFR Part 50.

e Please be reminded that 10 CFR 50.54(q) requires that proposed changes which l

. decrease the effectiveness of your Emergency Plan shall not be implemented 1

.without application.to and approval by the Commission. However, changes may be l

made without Commission approval. if such - changes do not decrease. the l

effectiveness of the Plan, and if-the. Plan, as changed, continues to meet the standards'of 50.47(b).and the requirements of Appendix E to 10 CFR Part 50.

If a change is made without approval, you should furnish copies'in accordance with-10CFR50.54(q).

Also, any changes to the Emergency Plan Implementing Procedures should be.made'in accorc'ance with the requirements of Section V of Appendix E to 10 C'R Part 50.

j Should you have any questions ' regarding this letter, please contact

.i Mr. Thomas R. Decker of our staff on 404-331-2559.

Sincereiy, I

Douglas M. Collins, Chief Emergency Preparedness and i

Radiological Protection Branch Division of Radiation Safety 1

and Safeguards cc:

.J. W. Hampton, Station Manager bec: 4'.-N. Jabbour, NRR NRC Resident Inspector

%ocumentControlDesk

)

% ate of South Carolina /en St maen"an 1

RI' RI RII RII l

h

&h nks:er beh TDecker TPeetfles for 08/A/87 O W 3/87 0 //2./87 08//L/87 f

I 8708270237 870814 PDR ADOCK 05000413 1 0 F

PDR crar

___ a