Notice of Violation from Insp on 870526-0612.Violation Noted:On 870506,15 & 23,valves Shut,Rendering Spray Additive Sys Incapable of Adding Naoh to Containment Spray Sys Pump Flow
ML20237K089
Person / Time
Site: Byron Constellation icon.png
Issue date: 08/13/1987
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20237K082 List:
References
50-454-87-22, EA-87-119, NUDOCS 8708190086
Download: ML20237K089 (1)


Text

e l

NOTICE OF VIOLATION Commonwealth Edison Company Docket No. 50-454 EA 87-119

)

As a result of the inspection conducted on May 26 - June 12, 1987, and in i

accordance with the " General Policy and Procedures for NRC Enforcement I

Actions," 10 CFR Part 2, Appendix C (1986), the following violation was I

identified:

Technical Specification 3.0.4 requires that entry into an. operational mode shall not be made unless the conditions of the Limiting Condition for 1

Operation are met.

Technical Specification 3.6.2.2 requires that the spray additive system shall be operable in modes 3 and 4 with a spray additive eductor capable of adding sodium hydroxide (Na0H) to a containment spray system pump flow.

With the spray additive system inoperable, restore the system to operable status within the next 120 hours0.00139 days <br />0.0333 hours <br />1.984127e-4 weeks <br />4.566e-5 months <br /> or else be in Cold Shutdown [ Mode 5] in the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

For the spray additive system to be operable, valves ICS018A and ICS018B must be open so that NaOH can flow from the storage tank to each of the spray additive eductors when the containment spray system is actuated.

Contrary to the above:

1.

On May 6 and May 23, 1987, Unit 1 entered Mode 4 with valves ICS018A i

and ICS0188 shut; thereby rendering the spray additive system incapable of adding Na0H to the containment spray system pump flow.

2.

From 0900 on May 6, 1987 to 1412 on May 15, 1987, with Unit 1 in Modes 3 i

i and 4, valves ICS018A and ICS018B were shut for greater than 120 hours0.00139 days <br />0.0333 hours <br />1.984127e-4 weeks <br />4.566e-5 months <br />; l

thereby rendering the spray additive system incapable of adding Na0H to the containment spray system pump flow, and action was not taken to place the unit in Mode 5 within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

This is a Severity Level IV violation (Supplement I) (454/87022-01(DRP)).

I Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office, within thirty days of the date of this Notice, a written statement or explanation in reply including for each violation:

(1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further violations; and (3) the date when full compliance will be achieved.

Consideration may be given to extending your response time for good cause shown.