_ ff tseg'o't UNITED STATES NUCLEAR REGULATORY COMMISSION 8
l'
,E WASM NG TO N. D. c. 20555
%,..... j#
August 18, 1987 Docket No. 50-298 Mr. George A. Trevors, Division Manager - Nuclear Support Nebraska Public Power District Post Office Box 499 Columbus, Nebraska 68601
Dear Mr. Trevors:
SUBJECT:
REQUEST FOR INFORMATION, 1987 USAR UPDATE (TAC # 65914)
Re:
Cooper Nuclear Station (CNS)
The staff has received the 1987 CNS USAR revisions forwarded by y.our letter dated July 22, 1987 and is conducting a limited review to determine if the
' changes are consistent with current staff criteria and if further in-depth i
review is warranted.
For most of the changes, the basis for the change is obvious (i.e. changes relating to deletion of 7x7 fuel, addition of barrier fuel, alternate safe shutdown system installation, pipe replacement, editorial corrections, new process computer /SPDS, pumproom fire protection, contro1 room habitability, high radiation areas, NPPD reorganization, MSL High Flow Switches, etc.).
However, for some of the changes, the staff lacks sufficient' background information to determine whe+.her the revisions should be reviewed by the staff.
Accordingly, you are requested to provide background information describing the changes made to the following pages:
(1) Page 11-4-8, relating to bienniel review of flooding control procedures (Was the previous semiannual review cycle based on a licensing commitment?);
(2) Table III-3-1, relating to thermal fatigue cycles (Describe re-analyses and findings);
(3) Page IV-12-2, relating'to SLCS high energy line break evaluation; (4) Figures IV-4-3 & 4, regarding SRVs; (5) Page VII-4-19, regarding deletion of RHR delta o switches (Does the revision relate to the deletion of the loop selection logic?);
(6) XIII-9-3, regarding SRAB member qualifications (Discuss consistency with external documents as indicated in July 22, 1987 letter.),
1 l
I 8708250154 870818 PDR ADOCK 05000290 p
eDn i
J
Mr. George A. Trevors *
~(7)' Page X-8-2, regarding reactor building basement flooding control-l-
(8)' Page XII-2-23, regarding seismic stress calculations.
Your response _is requested within 90 days.
I For future USAR revisions you need not include a description of 50.59 changes.
Instead you should consolidate all 50.59 descriptions in the Annual Operating Report.
If you have any questions please contact me at 301-492-4754.
The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under' P.L.L96-511.
Sincerely, IS{
William 0. Long, Project Manager Project Directorate-IV i
Division of Reactor Projects - III,
.l IV, V and Special Projects-i cc:
See next page-DIS UTION
'LDecket File NRC PDR Local PDR PD4 Reading F. Schroeder 1
P. Noonan i
Project Manager 0GC-Bethesda E. Jordan J. Partlow ACRS (10)
J. Jaudon E. Plettner DCS-042 PO4 Plant File LTR NAME: LETTER FOR GEORGE A. TREVORS 3
PD-4 A
PD-4 )
PD-4 PNoon WLong/tys JACalvo 08/f'//87 08/lt/87 08//s/87 J
m
'4 Mr. George A. Trevors-
. Nebraska Public' Power District-'
Cooper Nuclear Station cc:
.Mr. G. D. Watson, General Counsel Nebraska Public Power District P. O. Box 499-Columbus, Nebraska 68601 Cooper Nuclear Station ATTN:
Mr. Guy R. Horn Division Manager of-Nuclear Operations P. O. Box 98 Brownville, Nebraska 68321 Director:
Nebraska Department'of Environmental Control-
- P. 0. Box 94877 State House Station-Lincoln, Nebraska 68509 Mr. William Siebert, Commissioner Nemaha County Board of Commissioners Nemaha County Courthouse-Auburn, Nebraska 68305 l
Resident Inspector-U.S. Nuclear Regulatory Commission P. O. Box 218 Brownville, Nebraska' 68321 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington,' Texas 76011 Mr. Harold Borchart, Director Division of Radiological Health Department of Health 301 Centennial Mall, South P. O. Box 95007 Lincoln, Nebraska 68509 l
- - - _ - - - - - _ - - - - - - - -