_ _ - _ _ _ _ _
3MUF:ALS 0 ISOI DOCKET:
70-824 LICENSEE:
Babcock & Wilcox Naval Nuclear Division NNFD Research Laboratory FACILITY:
Lynchburg, Virginia
SUBJECT:
SAFETY EVALUATION REPORT, APPLICATION DATED JUNE 19, 1986, RE RELEASE OF BUILDING A FOR UNRESTRICTED USE
Background
Building A was formerly used to support reactor experiments which were conducted under an NRC reactor license. On June 23, 1983, the licensee informed the NRC=
.that they planned to decontaminate Building A and requested that upon completion of the decontamination, the area be released from License No. SNM-778.
In 1986, the licensee completed the decontamination work and requested by application dated June 19, 1986, that Building A be unconditionally reroved from License No. SNM-778. To support the request, a radiological survey report was provided.
Discussion After the staff's review of the survey report, Region II had Oak Ridge Associated' Universities (0RAU) perform a confirmatory survey. By memorandum dated May 8, 1987 (DCollins to LRouse), Region II recommended that Building A be released in accordance with the " Guidelines for Decontamination of Facilities and Equipment Prior to Release for Unrestricted Use or Termination of Licenses for Byproduct, Source, or Special Nuclear Material," and dose rate limits of 5 microroentgen per hour at I meter.
On August 10, 1987, the staff discussed the licensee's request with Mr. Alexander Adams, NRR Project Manager for the reactor license. He has no objection to the release of Building A from License No. SNM-778.
Conclusion Based on the results of the radiological survey, the contamination levels in Building A are less than NRC release criteria. The staff recommends that License No. SNM-778 be amended to delete and release Building A for unrestricted
- use, gB2gggg gj@BQ24 An-Lian Soong g
l Fuel Cycle Safety Branch Division of Industrial and Iq
/
Medical Nuclear Safety, NMSS l
0 Approved by:
k V.
h-Jrry/J/. Swift,{ectionLeader
!]nn I..
...[
j NAME:ALSoong/as:VLRarpe :JSw'if t DATE:8////87'
- 8/b87
- 8//b/87 :
OFFICIAL RECORD COPY m___