Text

..

I l

i I

i ATTACHMENT l

l Consumers Power Company

]

Palisades Plant i

Docket 50-255 1

SEMI-ANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT JULY - DECEMBER 1986 CORRECTIONS This is a complete copy of the titled report with corrections marked in the right hand margin with a '#'

for clarity.

August 28, 1987 1

1 i

i f

l 8709020060 870828"~

DR ADOCK 05000255 PDR f

l 6 Pages i

ATT0887-0137-NLO2

's i

i o

2 l

PALISADES NUCLEAR PLANT SEMIANNUAL EFFLUENT RELEASE REPORT July - December 1986 This report provides information relating to radioactive effluent releases and solid radioactive waste disposal operations of the Palisades Plant during the

'eriod of July through December 1986 in the format contained in Plant Tech-nical Specification 6.9.3.la.

The July - December 1986 semiannual ef fluent release report reflects effluent Technical Specification changes. effective January 1, 1985. Due to the extended maintenance outage since May 19, 1986, both the third and fourth quarter gaseous effluent releases reflect only residual activity levels.

1.

SUPPLEMENTAL INFORMATION A.

BATCH RELEASES Information relating to batch releases of liquid and gaseous effluent is provided in Table HP 10.5-1.

B.

ABNORKAL RELEASES l

None.

2.

CASEOUS EFFLUENTS Table HP 10.5-2 lists and summarizes all gaseous radioactive effluents released during the reporting period. The unidentified beta was 9.30E-03% of the total release.

3.

LIQUID EFFLUENTS Tab'e HP 10.5-3 lists and summarizes all liquid radioactive ef fluents released during the reporting period. The unidentified beta was 1.02E-02% of the total release.

4.

SOLID WASTE Solid radwaste classification, sources, volume shipped, curie and nuclide content are detailed in Table HP 10.5-4.

All radwaste shipments were made to either Barnwell, South Carolina or Richland, Washington for burial.

5.

SUMMARY

OF RADIOLOGICAL IMPACT ON MAN Potential doses to individuals and populations were :alculated using CASPAR and LADTAP computer program codes. The third and fourth quarter values for curies released were input for each nuclide and summarized as follows:

IC0287-0096A-HP01

TABLE HP 10.5-1 PALISADES PL\\NT/ SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BATCH RELEASES-l JULY 1986 to DECEMBER 1986 I

i A.

CASE 0VS Units 3rd Quarter 4th Quarter Number of Releases 14 4*

Total Release Time Minutes

~2.85E+03 7.61E+02 Maximum Release Time Minutes 4.92E+02 2.23E+02 Average Release Time Minutes 2.04E+02 1.90E+02 Minimum Release Time Minutes 4.0E+01 1.43E+02 B.

LIQUrD Units 3rd Quarter 4th Quarter

_ Number of Releases 42 23-Total Release Time Minutes 4.06E+03 2.64E+03 Maximum Release Time Minutes 5.78E+02 5.80E+02 Average Release Time Minutes 9.66E+01 1.15E+02 Minimum Release Time Minutes 3.5E+01 3.2E+01 i

  • 4th Quarter releases did not contain radioactive material.

The waste gas decay tanks were pressurized for maintenance activities.

IC0287-0096A-1:P01

a.

TABLE HP 10.5-2 PALISADES PLANT /SEhi ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT J

CASEOUS EFFLUENTS - SUMMATION OF RELEASES JULY 1986 to DECEMBER 1986 I

Est Total !

A.

FISSION AND ACTIVATION CASES UNITS 3rd OUARTER 4th QUARTER Error

(

l.

Total release Ci 4.85E-02 None l

2.

Average release rary for period uCi/sec 6.10E-03 None 12.4

{

3.

Percent of annual avg MPC 2.71E-06 None

)

i B.

IODINES 1.

Total Iodine Ci 5.73E-06 None i

2.

Average release rate for period uCi/sec 7.21E-07 None 16.1*

i 3.

Percent.of annual avg MPC 1.03E-06 None C.

P ARTICU LATES 1.

Particulate with half-life >

i 8 days I

Ci 4.56E-05 3.08E-05 2.

Average release rate for period i

uCi/sec l 5.73E-06 3.87E-06 l

3.

Percent of annual avg limit MPC i

i 2.19E-06 4.89E-06 13.8 4

Cross alpha radioactivity i

Ci 5.45E-06 3.54E-06 i D.

TRITI UM

{

I 1.

Total release i

Ci 7.59E-01 6.65E-01 1

2.

Average release rate for period t

uCi/sec !

9.55E-02 l 8.36E-02 1

3.

Percent of annual avg MPC I

i 6.82E-05 i 5.97E-05

' E.

1.

Beta air dose at site boundary due

{

l' to Noble Cases (TS 3.24.5.2a) mRads 2.37E-06 None 2.

Percent limit 2.37E-05 None i

3.

Camma air dose at site boundary due l

to Noble Cases (TS 3.24.5.21) mRads 2.98E-07 None i

l 4.

Percent limit 5.96E-06 None F.

I 1.

Maximum organ dose to public based based on critical receptors l

(TS 3.24.5.3) mrem 6.02E-04 5.28E-04 l

2.

Percent of limit 8.03E-03 7.04E-03 l

  • Note:

Data is reported for I-131 (no I-133 present) 1 i

IC0287-0096A-HP01

1 o

TABLE HP 10.5-2 PALISADES PLANT / SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT CASEOUS EFFLUENTS JULY 1986 to DECEMBER 1986 i

j e

3.

PAR TICULATES*

Units 3rd QUARTER 4th QUARTER

]

Chromium-51 Ci None None i

l i

Manganese-54 I

Ci None None Cobalt-58 Ci None None j

Cobalt-60 Ci 7.02E-08 7.69E-06 1

Zine-65 Ci None None l

Silver-110m Ci None None Cesium-134 Ci None None j

Cesium-137 Ci None None l

1 I

Barium-140 Ci None None Mercury-203 Ci None None I

Selenium-75 Ci 3.58E-05 1.34E-05 l

l Strontium-89**

Ci 7.05E-06 2.69E-06

  1. j Strontium-90**

ci 2.66E-06 2.51E-06 i

Net unidentified

{

g

[

i beta I

Ci i

None 4.52E-06 4

i k

Total Ci I

4.56E-05 3.08E-05

  • Particulate with half-lives >8 days.
    • Calculated from vendor analysis of monthly stack gas filters.

NOTE:

Reported net beta and vendor analyzed Sr-89/90 results were input t.o CASPAR code as Sr-90 to ield conservative dose estimates.

IC0287-0096A-HP01

I TABLE HP 10.5-3 PALISADES PLANT / SEMI ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT I

i LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES JULY 1986 to DECEMBER 1986 Est Total A.

FISSION AND ACTIVATION CASES UNITS 3rd QUARTER 4th QUARTER Error 1.

Total release (not including tritium, gases, alpha)

Ci 1.45E-02 6.50E-03 2.

Average diluted concentration l

during period i uCi/mi 6.66E-10 3.22E-10 10.4 f

3.

Percent of MPC i

3.89E-02 i

1.10E-02 l

l B.

TRI TI UM i

1.

Total release i

Ci 2.09E+01 8.39E+00 i

2.

Average diluted concentration during period uCi/mi 9.58E-07 I

4.15E-07 9.56 i

3.

Percent of MPC i

3.19E-02 i

1.38E-02 I

)

C.

DISSOLVED AND ENTRAINED CASES I

1.

Total Release Ci None None 2.

Average diluted concentration during period uCi/ml None None N/A 3.

Percent of MPC None None

'D.

CROSS ALPHA RADIOACTIVITY (Total Release) **

Ci 4.09E-06 4.08E-06

'E.

VOLUME OF WASTE RELEASED l

(Prior to Dilution)

Liters 8.50E+05 l

5.5$J m t F.

VOLUME OF DILUTION WATER USED DURING PERIOD Liters 2.18E+1C 2.02E+10 C.

MAXIMUM DOSE COMMITMENT - WHOLEBODY mrem

8. 4 2 E-03,

4.43F-03 Percent of TS 3.24.4.la limit 5.61E-Ol_

2,95E-01 H.

MAXIMUM DOSE COMMITMENT - ORGAN mrem 1.32E-02 7.62E-03 Percent of TS,3.24.4.la limit 2.64E-01 1.52E-01

    • Calculated f rom vendor analysis of monthly radwaste composite samples.

~

IC0287-0096A-HP01

?

l TABLE HP 10.5-3 l

l PALISADES PLANT / SEMI ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS i

i JULY 1986 to December 1986 l

1.

NUCLIDES RELEASED Units 3rd QUARTER 4th QUARTER Cesium-137 Ci 3.03E-03 1.82E-03 i

Cobalt-58 Ci 3.49E-03 i

6.77E-04 l

Manganese-54 Ci 7.81E-04 3.52E-04 i

Cobalt-60 Ci 4.13E-03 1

2.72E-03 l

l Cesium-134 Ci 6.69E-04 1

2.87E-04 l

Niobium-95 Ci 2.74E-06 None l

i i

Strontium-89**

Ci 1.21E-05 2.82E-05 Strontium-90**

Ci 1.70E-05 1.07E-05 Net Unidentified i

l Beta Ci 2.40E-03 i

6.02E-04

~~

Fission & Activation j

Product Total (Above)

Ci 1.45E-02 6.50E-03 I

Xenon-133 Ci None None Tritium Ci 2.09E+01 8.39E+00 Crand Total Ci 2.09E+01 8.40E+00 Calculated from vendor analysis of monthly radwaste composite samples.

NOTE: Reported net beta and vendor analyzed Sr-89/90 results were input to LADTAP code as Sr-90 to yield conservative dose estimates.

i 1

l

.g IC0287-0096A-HP01

~~~

t d

  • kyg,.

USNRc.g3 NOI SEP ; A 9 4 7 l

l a,

',e O 1