Forwards Insp Rept 99900317/87-02 on 871005-09 & Notices of Violation & Nonconformance.Weaknesses in Implementation of QA Program in Areas of Procurement,Vendor Audits & Items Re Cooper Industries Organizational Structure Identified
ML20237B326
Person / Time
Issue date: 12/15/1987
From: Stone J
Office of Nuclear Reactor Regulation
To: Stolba F
COOPER INDUSTRIES, INC.
Shared Package
ML20237B329 List:
References
REF-QA-99900317 NUDOCS 8712160190
Download: ML20237B326 (4)


Text

.

j:

/

'o UNITED STATES

~g

[

g NUCLEAR REGULATORY COMMISSION

E W ASHINGTON, D. C. 20555 Decsmber 15, 1987 Docket No. 99900317/87-02 Cooper Industries Cooper Energy Services i

ATTN: Mr. F. B. Stolba Vice President and General Manager 150 Lincoln Avenue Grove City, Pennsylvania 16127 Gentlemen:

On October 5-9, 1987, Mr. P. J. Prescott, Mr. J. T. Conway, and Mr. E. Tomlinson conducted an inspection of your facility at Grove City, Pennsylvania.

At the conclusion of the inspection, the findings were discussed with Mr. W. H. Allen Lambert and members of your staff. This letter delineates NRC actions resulting from that inspection.

The inspection was made as a result of several recent and significant 10 CFR I

Part 21 and 10 CFR 50.55(e) reports involving Cooper standby diesel generators at nuclear power plants.

In addition, several issues concerning the Palo Verde 3B emergency diesel generator (EDG) were reviewed during the inspection.

The enclosed inspection report discusses the areas examined during the inspection and our findings. Within these areas, the inspection consisted of an examination af procedures and representative records, interviews with personnel, and observations by the inspectors.

During the inspection the NRC inspectors found that the implementation of your program concerning 10 CFR 21 failed to meet certain NRC requirements.

Further, they identified weaknesses in the implementation of your quality assurance program in the areas of procurement, vendor audits and identified items con-j cerning Cooper Industries (CI) organizational structure.

The enclosures to this letter provide the specific findings and references to the pertinent requirements.

The enclosed Notice of Violation is sent to you pursuant to the provisions of Section 206 of the Energy Reorganization Act of 1974.

You are required to submit to this office within 30 days from the date of this letter a written statement containing (1) a description of steps that have been or will be i

taken to correct these items, (2) a description of steps that have been or will be taken to prevent recurrence, and (3) the dates your corrective actions and preventive measures were or will be completed.

Your response time may be extended if you are able to show good cause, l

You are also requested to submit a similar written statement for each item that appears in the enclosed Notice of Nonconformance.

8712160190 871215 PDR GA999 EMVC t

99900317 i

$Y

)

~

Cooper Incustries December 15, 1987 The responses requested by this letter are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

In accordance with 10 CFR 2.790 of the Coninission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, A ~b -

James C. Stone, Acting Chief Vendor Inspection Branch Division of Reactor Inspection and Safeguards Office of Nuclear Reactor Regulation

Enclosures:

1.

Appendix A - Notice of Violation 2.

Appendix B - Notice of Nonconformance 3.

Appendix C - Inspection Report No. 99900317/87-02 cc w/ enclosures:

Commonwealth Edison Company ATTN: Mr. Dennis L. Farrar Director of Nuclear Licensing P. O. Box 767 Chicago, Illinois 60690 Arizona Public Service company ATTN: Mr. E. E. Van Brunt, Jr.

Executive President Arizona Nuclear Power Project P. O. Box 52034 Phoenix, Arizona 85072-2034 Houston Lighting & Power Company j

ATTN: Mr. J. H. Goldoerg Group Vice President, Nuclear P. O. Bcx 1700 Houston, Texas 77001 i

1

\\

l

1 Cooper Industries l December 15, 1987 i

i l

I DISTRIBUTION:

[,RIDSCodeIE:09 DRIS Reading s

VIB Reading JPartlow l

BGrimes

{

JStone EBaker PPrescott (2)

LParker L01shan, NRR SSands, NRR ELicitra, NRR PKadambl, NRR ETomlinson, NRR i

l 1

l \\

  • See previous page for concurrences.

I 1

l l

OFC :VIB:DRIS

ASC/VIB:DRIS :ABC/VIB:DRIS:

NAME :PPrescott:jh* :EBaker*

JStone*

DATE :12/14/87

12/14/87
12/15/87 i

l i

)

l Cooper Industries December 15, 1987

)

DISTRIBUTION:

RIDS Code IE:09 DRIS Reading VI8 Reading JPartlow BGrimes JStone EBaker PPrescott (2)

LParker L01shan, NRR SSands, NRR ELicitra, NRR PKadambl NRR ETomlinson, NRR l

l l

l

  • See previous page for concurrences.

IFC :VIB:DRIS

ASC/VIB:DRIS :ABC/VIB:DRIS:

LAME :PPrescott:jh* :EBaker*

JStone*

) ATE :12/14/87

12/14/87
12/15/87 il