ML20236X527

From kanterella
Jump to navigation Jump to search

Extends Temporary Waiver of Compliance for Tech Spec 3.5.G.2 for Addl 60 Days Due to Util 871124 Request for Rev to Original 871006 Submittal.Temporary Waiver Originally Issued on 871006 for 60 Day Period
ML20236X527
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 12/04/1987
From: Holahan G
Office of Nuclear Reactor Regulation
To: Butterfield L
COMMONWEALTH EDISON CO.
References
TAC-66344, TAC-66345, NUDOCS 8712090262
Download: ML20236X527 (3)


Text

1 December 4, 1987 Dockets Nos. 50-254 DISTRIBUTION and 50-265 Dockets Files OGC-Bethesda 1

NRC & Local PDRs EJordan

)

Mr. L. D. Butterfield, Jr.

PDIII-2 Rdg. File JPartlow Nuclear Licensing Manager GHolahan PDIII-2 Plant File Commonwealth Edison Company LLuther Post Office Box 767 TRoss Chicago, Illinois 60690

SUBJECT:

TEMPORARY WAIVER OF COMPLIANCE FOR TECHNICAL SPECIFICATION 3.5.G.2 RE: DISCHARGE PIPE PRESSURE FOR HPCI/RCIC (TAC NOS. 66344 AND 66345)

Dear Mr. Butterfield:

By letter dated October 6,1987, Commonwealth Edison Company (CECO, the licensee) requested a temporary waiver of compliance from Technical l

Specification (TS) 3.5.G.2 which requires a certain discharge pipe pressure band for systems specified in TS 3.5.G.I.

This letter also provided an applicable amendment request and safety evaluation. The NRC staff reviewed CECO's submittal and issued a temporary waiver of compliance, also dated October 6,1987, for the Quad Cities Nuclear Power Station (QCNPS).

Compliance with TS 3.5.G.2 was waived at QCNPS for 60 days to provide the staff with enough time to issue a formal TS amendment.

However, since then, CECO has requested a revision (dated November 24,1987) to their original submittal based upon subsequent discussions with the staff.

Consequently, the temporary waiver of compliance for TS 3.5.G.2 is hereby extended for another 60 days. This should allow the staff sufficient time to process the licensee's supplementary submittal (i.e. renotice in Federal Register with associated 30 day comment period).

Sincerely,l Is Gary Holahan, Assistant Director for Regions III and V Division of Reactor Projects - III, IV, V and Special Projects cc:

A. B. Davis C. Norelius W. Forney M. Ring l

T. Ross i

See next page

  • Previously Concurred

{

PDIII-2:PM PDIII-2:PD

/0 P

  • TRoss
  • DMuller GHolahan 12/02/87 12/02/87 ry /4 /87 8712090262 871204 PDR ADOCK 05000254 P

PDR

fir. L. D. Butterfield, Jr.

Quad Cities Nuclear Power Station Commonwealth Edison Company Units 1 and 2

~

cc:

Mr. Stephen E. Shelton Vice President Iowa-Illinois Gas and Electric Company P.O. Box 4350 Davenport, Iowa 5280B Mr. Michael Miller Isham, Lincoln & Beale Three First National Plaza Suite 5200 Chic 2go, Illinois 60602 Mr. Richard Bax Station Manager Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, Illinois 61242 Resident Inspector U.S. Nuclear Regulatory Commission 22712 206th Avenue North Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, Illinois 61201 Mr. Michael C. Parker, Chief Division of Engineering Illinois Department of Nuclear Safety 1035 Outer Park Drive Springfield, Illinois 62704 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

-g m___ _ _. _ - - - - - - -

r______

4 4

Docket Nos. 50-254/265 Mr. L.D.Butterfield, Jr.

Nuclear Licensing Manager Commonwealth Edison Company Post Office Box 767

\\

Chicago, Illinois 60690 '.

\\

SUBJECT:

TEMPORARY WAIVER OF COMPLIANCE FOR TECHNICAL SPECIFICATION 3.5.G.2 RE: DISCHARGE PIPE PRESSURE FOR HPCI/RCIC Dear Mr. Butterfield s

By letter dated October 6,1987, Commonwealth Edison Company (CECO, the licensee) requested a temporary waiver of compliance f rom Technical Specification (TS) 3.5.G.2 which requires a certain discharge pipe pressure band for systems specified in TS 3.5;G.I. This letter also provided an applicable amendment request and safety evaluation. The NRC staff reviewed Ceco's submittal and issued a temporary waiver of compliance, also dated October 6,1987, for the Quad Cities Nuclear Power Station (QCNPS). Compliance with TS 3.5.G.2 was waived at QCNPS for 60 days to provide the staff with enough time to issue a formal TS amendment.

However, since then, CECO has requested a revision (dated November 24,1987) to their original submittal based upon subsequent, discussions with the staff.

Consequently, the temporary waiver of compliance for TS 3.5.G.2 is hereby extended for another 60 days. This should allow the staff sufficient time to process the licensee's supplementary submittal (i.e. re-notice in Federal Register with associated 30 day comment period).

Sincerely, Gary Holohan',, Assistant Director for RegionstIII & V Reactors Division of Reactor Projects III, IV, V and Special Projects f

AD/III&V/DRSP PM/PD32/ PSP'lp PD/PD32/DRSP g

pDMuller CHolohan TRoss 1L/ L /t 7

\\l/~L / 01

/ /

. - - _ _ _ _ _ _ -