ML20236V491

From kanterella
Jump to navigation Jump to search
Ack Receipt of 871028 Response to NRC & Notice of Violation from Insp Rept 50-482/87-20.Reply Responsive to Concerns
ML20236V491
Person / Time
Site: Wolf Creek 
Issue date: 12/01/1987
From: Callan L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Withers B
WOLF CREEK NUCLEAR OPERATING CORP.
References
NUDOCS 8712040336
Download: ML20236V491 (2)


See also: IR 05000482/1987020

Text

-

%.

. . .

.

In Reply' Refer To:

DEC

Docket:

STN 50-482/87-20

. IIE

Wolf Creek Nuclear Operating Corporation

ATTN:

Bart D. Withers

President and Chief Executive Officer

P.O. Box 411

Burlington, Kansas

66839'

Gentlemen:

' Thank you for your letter of October 28, 1987, in response to our letter

and Notice of Violation dated September 30, 1987.

We have reviewed your reply

i

l

l

and find it responsive to the concerns raised'in our Notice of Violation.

We

will review the implementation of your corrective actions during a future

inspection to determine that full compliance has been achieved and will be

l

maintained.

Sincerely,

Original Signed By

L. J. Callan

l

L. J. Callan, Director

Division of Reactor Projects

cc:

Wolf Creek Nuclear Operating Corporation

ATTN: Otto Maynard, Manager

of Licensing

P.O. Box 411

Burlington, Kansas

66839

Wolf Creek Nuclear Operating Corporation

ATTN: Gary Boyer, Plant Manager

P.O. Box 411

Burlington, Kansas

66839

Kansas Corporation Commission

ATTN:

Mr. Robert D. Elliott, Chief Engineer

Fourth Floor, Docking State Office Building

Topeka, Kansas

66612-1571

Ka 'a Radiation Controlf f gram Director

. RP/PSA

P$

DRP

f/Ji:Tapia;df

JP au' don

LJCallan

-

\\l/bb/87

l( /9]]87

I?/ q/87

/ C6 /

9712040336 871201

)

PDR

ADOCK 05000482

G

PDR

- _ _ - -

]

2

,

!

Wolf Creek Nuclear Operating

-2-

Corporation

bec to DMB'(IE01)

bec'distrib. by RIV:

Myron Karman, ELD, MNBB (1)

  • RRI

R. D. Martin, RA

  • Section Chief (DRP/A)
  • DRP.

RPSB-DRSS

W. L. Forney, RIII

  • RIV File

Resident Inspector, RIII

  • MIS System
  • RSTS Operator
  • Project Engineer, DRP/A
  • R. Hall
  • Lisa Shea, RM/ALF
  • P. O'Connor, NRR Project Manager
  • DRS
  • TSS
  • w/766

i

1

i

1

_ _ _ _ _ - _ -

,

.

.

~.-

.

.

W4) NUCLEAR OPERATING

,

.

.

Bart D. Withers

b i'i -/

e,L ' (

Present end

4

i

O ,i

October 28,i1987 7-

p

Chief ExecuWe Omcor -

,

e,t 1

WM 87

/

U. S. Nuclear Regulatory Commission

!

ATTN:

Document Control Desk

j

Washington, D. C. 20555

'

Reference:

Letter dated 9/30/87, from J. E. Gagliardo, NRC, to

B. D. Withers, WCNOC

Subj ect:

Docket No. 50-482:

Response to Violation 482/8720-01

l

Gentlemen:

'

Attached is a detailed response to violation 482/8720-01 which

was

documented" in the Reference.

Violation 482/8720-01 concerns a failure to

enter Technical Specification 3.0.3 when both trains of the control room

)

emergency ventilation system were inoperable when a door was blocked open.

4

If you have any questions concerning this matter, please contact ne or Mr.

O. L. Maynard of my staff.

Very truly yours,

4

Bart D. Withers

President and

Chief Executive Officer

BDW/jad

Attachment

ec:

P. W. O'Connor (2)

R. D. Martin

J. E. Cuttnins

.

C. A. Hackney

-gM-6

$

A4

e

.

RO. Box 411/ Burlington, KS 66839 / Phone: (316) 364-8831

An Equal Opportunny Ernployer uf/HC/ VET

- _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ - - - - _ _ - _ - - - -

--

-

- - -- A

_

_ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

'.

-

'

~

.

.

Attachment to WM 87-0289

Page 1 of 2

October 2& 1987

Violation (482/8720-01): Failure To Enter Technical Specification

(TS)_3.0.3

Finding:

Technical Specification 3.0.3 requires, in part,

"When a limiting condition

for operation is not met,

except as provided in the associated action

requirements, within 1-hour action shall be initiated to place the unit in a

mode in which the specification does not apply..."

TS 3.7.6 requires,

"Two independent control room emergency ventilation

systems shall be operable."

Contrary to the above, on August 20,

1987, the NRC inspector observed both

trains of the control room emergency ventilation system inoperable when Door

36171 was blocked open preventing the control room from being pressurized to

greater than or equal .25 inches of water.

Reason For Violation:

,

On August 20,

1987,

at approximately 1330 CDT, the NRC Resident Inspector

found Door 36171, which separates the Control Room from an electrical chase

area, propped open for rework of penetrations by Facilities and Modification

(F&M) personnel.

The Shift Supervisor was aware of the rework activity, but

was unaware that it required the door to be propped open.

With this door

open, it was concluded that positive pressure could not be maintained in the

l

Control

Room which is contrary to Technical Specifications (TS) and should

i

have resulted in TS 3.0.3 entry.

'

This violation has been attributed to a failure to effectively communicate

between the Shift Supervisor involved and the F&M personnel performing the

work activity.

This Technical Specification violation was reported to the

NRC in LER 87-034-00.

Corrective Ste_ps Which Have Been Taken and Results Achieved:

The Shift Supervisor promptly took cotapensatory measures upon notification

that the door was propped open to restore the operability of both Control

l

Room Emergency Ventilation Systems.

Corrective Steps Which Will_ Be Taken To Avoid Further Violations:

In order to prevent the recurrence of this event,

the following corrective

actions have been implemented:

(1)-

Permanent signs have been posted on Door 36171 and two other similar

doors informing personnel that the doors are part of the Control Room

pressure boundary and the Control Room must be contacted prior to

initiating any work that would require propping the doors open.

,

i

l

,s

X L%

+,

o

_ - _ _ _ _ _ . .

.

,

--

,

,

. / ., ^.

'

'

Attachment'to.WM 87-0289

]

.Page 2 of 2

October 28, 1987

]

(2)

F&M Engineers have been instructed to' include precautionary statements'

into their work packages to emphasize pressure boundary. considerations;

prior to starting work.

(3)

F&M personnel, including Contractors, have been instructed to contact

Control Room personnel when work could affect a pressure boundary.;.

(4)

A change has been made to .the Control Room- Ventilation Isolation

Signal alarm response procedure to close the doors if open.

~

(5)

LER 87-034-00 has been added to Operations' Required Reading.to remind.

licensed personnel of- the importance of considering potential effects

on pressure boundaries when authorizing work activities.

Date When Full Compliance Will Be Achieved: .

Full compliance has been achieved.

1

l

i

,

j

4

1

,

!

1

!

..

O

P

4.

.I

h_