Proposed Tech Spec 5.2.2(b),Page 5-1,correcting Ref to Max Internal Torus Temp
ML20236U314
Person / Time
Site: Brunswick  
Issue date: 11/24/1987
From:
CAROLINA POWER & LIGHT CO.
To:
Shared Package
ML20236U307 List:
References
NUDOCS 8712020430
Download: ML20236U314 (3)


Text

l i

ENCLOSURE:1 BRUNSWICK STEAM ELECTRIC PLANT, UNITS 1 AND 2 i

NRC DOCKETS 50-325 & 50-324 OPERATING LICENSES DPR-71 & DPR-62 REQUEST FOR LICENSE AMENDMENT -

REVISED TECHNICAL SPECIFICATION PAGES'

.I l

'l i

l 1

0712020430 871124 ~

- DR ADOCK 050 (5329 BAT /bmc1' i

i (BSEP-1-98).

5.0 DESIGN FEATURES 5.1 SITE

' EXCLUSION AREA

{

l 5.1.1 The exclusion area shall be as shown in Figure 5.1.1-1.

LOW POPULATION ZONE

'l

)

5.1.2 The low population zone shall be as shown in Figure 5.1.2-1, based on the information given in Section 2.2 of the FSAR.

SITE BOUNDARY l

J 5.1.3 The SITE BOUNDARY shall be as a shown in Figure 5.1.3-1.

For the purpose of effluent release cal,culations, the boundary for atmospheric releases is the SITE BOUNDARY and the~ boundary for-liquid releases is the SITE BOUNDARY prior.to dilution in the Atlantic Ocean.

5.2 CONTAINMENT CONFIGURATION 5.2.1 The PRIMARY CONTAINMENT is a steel-lined reinforced concrete structure composed of a series of vertical right cylinders and truncated cones which form a drywell. This drywell is attached to a suppression chamber through a series of vents. The suppression chamber is a concrete steel-lined pressure vessel in the shape of a torus. The primary containment has.a minimum free air volume of (288,000) cubic feet.

DESIGN TEMPERATURE AND PRESSURE 5.2.2 The primary containment is designed and shall be maintained for:

a.

Maximum internal pressure 62 psig.

0 b.

Maximum internal temperature: drywell 300 F.

j 0

suppression chamber 220 F.

f c.

Maximum external pressure.

~ig.

5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 560 fuel assemblies limited to the following fuel types: 8x8R, P8x8R, BP8x8R, and CE8.

l BRUNSWICK - UNIT 1 5-1 Amendment No.

.._a_._

(BSEP-2-99)-

5.0 DESIGN FEATURES 1

i 5.1 SITE.

EXCLUSION AREA 5.1.1 The exclusion area shall be as shown'in Figure 5.1.1-1.

i LOW POPULATION ZONE 5.1.2 The low population zone shall be as shown in Figure 5.1.2-1.

SITE BOUNDARY 5.1.3 The SITE BOUNDARY shall be as shown in Figure 5.1.3-1.

For'the purpose of effluent release calculations, the boundary for atmospheric releases is the SITE BOUNDARY and the boundary,for liquid releases is the SITE BOUNDARY prior i;

to dilution in the Atlantic Ocean.

11 5.2 CONTAINMENT l

CONFIGURATION 5.2.1 The PRIMARY CONTAINMENT is a steel-lined, reinforced concrete structure composed of a series of vertical right cylinders and truncated cones which form a drywell. This drywell is attached to a suppression chamber through a series of vents. The suppression chamber is a concrete, steel-lined preasure vessel in the shape of a torus. The primary containment has a minimum free air volume of 288,000 cubic feet.

DESIGN TEMPERATURE AND PRESSURE 5.2.2 The primary containment is designed and shall be maintained for:

a.

Maximum internal pressure 62 psig.

j b.

Maximum internal temperature: drywell 300*F l

Suppression chamber 220*F l

c.

Maximum external pressure 2 psig.

5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 560 fuel assemblies limited to the following fuel types: 8x8R, P8x8R, BP8x8R, and CE8.

BRUNSWICK - UNIT 2 5-1 Amendment No.

'}