ML20236K441
| ML20236K441 | |
| Person / Time | |
|---|---|
| Site: | Perry |
| Issue date: | 07/30/1987 |
| From: | Norelius C NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Edelman M CLEVELAND ELECTRIC ILLUMINATING CO. |
| Shared Package | |
| ML20236K444 | List: |
| References | |
| NUDOCS 8708070121 | |
| Download: ML20236K441 (2) | |
See also: IR 05000440/1987014
Text
_ - - _ _ _
we '
- =
}/:jsauaug%j
-
UNITED STATES
NUCLEAR REGULATORY COMMISSION
%
REGION lli
r,
e
ne nooseveu mono
.o
[
OLEN ELLYN, ILUNOt5 40137
g
.....
JUL 3 01987
Docket No. 50-440
The Cleveland Electric
Illuminating Company
ATTN:
Mr. Murray R. Edelman
- Vice President
Nuclear Group
Post O mce Box 5000
Cleve
.. , OH 44101
Gentlemen:
This refers to a special onsite investigation review conducted by the NRC
Augmented Investigation Team (AIT) on June 17-20, 1987, relating to the
unexpected scram following a loss of the "A" RPS bus and an unexpected closure
of the outboard Main Steam Isolation Valves.
This also refers to discussions
of findings with yourself, Mr. A. Kaplan, and others of your staff during the
course of and at the conclusion of the onsite AIT review on June 20, 1987.
We are concerned about the series of errors that were made that allowed the
plant to be designed, constructed, and tested without identifying that-the
plant was not built in accordance with the Final Safety Analysis Report.
Enforcement action with respect to these errors will be forthcoming in a
subsequent report.
The enclosed copy of the Aagmented Inspection Team report identifies areas
examined during this review.
Within these areas the investigation consisted
of a review of representative records, observations, and interviews with
personnel.
In accordance with 10 CFR 2.790(a) a copy of this letter and the enclosure
will be placed in the NRC Public Document Room.
We will gladly discuss any questions you have concerning this inspection.
Sincerely,
6hca % $ Y A J
Charles E. Norelius, Director
DivisionofReactorProjects
Enclosure:
Augmented Investigation
Team Report No. 50-440/87014(DRP)
See Attached Distribution
l
l
%"omK050004o
h?}
erorso
!-
G
,
'
.<
_ _ _ _ _ _ _
-_
ff.
- h rg lr n ? ' :lyJ.r
.
e
" u s- ;
e
A
'
3'
- &*'
r
1
'O
s, + % < s t
s "m ft'k i *
qla ': y,,3 y n-
_, L ;ty
v
I
ui1M.
t ;__q-
%
~
,
_
r. -
fp
.
-The Cleveland Electric
~ 2
JUL 3 o 1937 '
Illuminating Company
l
cc w/ enclosure:
- 17. R. Stead, Manager, Perry
Plant Technical Department
M. D. Lyster, Manager, Perry Plant
Operations Department
Ms. E. M. Buzzelli, General
Supervising Engineer, Licensing
and Comp 1f3nce Section
' .
c0CS/RSB (RIDS)
Licensing Fee Management . ranch
B
Resident Inspector, RIII
Terry J. Lodge, Esq.
James W. Harris, State of Ohio
Robert M. Quillin, Ohio
Department of Health
State of Ohio, Public
Utilities Comission
R. L. Spessard, AE0D
T. M. Novak, AE0D
T. G. Colburn, NRR
W. D. Lanning, NRR-
i
.
I