%; a....j SUPPLEMENTAL SAFETY EVALUATION ON COOPER NUCLEAR STATION

' COMPLIANCE WITH ATWS RULE 10 CFR 50,62-i RELATING TO ALTERNATP ROD INSERTION SYSTEM NEBRASKA PUBLIC POWER DISTRICT DOCKET N0.-50-298 L

1. 0 INTRODUCTION On September 23,1987, the_ staff issued its Safety Evaluation (SE) for its evaluation of the Alternate Rod Insertion (ARI) system proposed for installation in the Cooper Nuclear. Station during the 1988 refueling
j outage.

The SE was based on information provided by the licensee in~its letters dated October. 14, 1985 and April 8, 1987, and in a telecopy provided on August 4,-

1987.

In the October 14 letter, the licensee _ stated that the ARI' solenoid valves would be provided with control room position i

indication.

However, in a letter dated October 13, 1987 the licensee requested staff concurrence to provide position indication at another location outside the control room (auxiliary relay room) instead of in the control ~ room.

i 2.0 EVALUATION The staff's September 23, 1987 SE acknowledged the licensee's original plans to provide control room solenoid valve position indication.

However, i

such a feature is not a requirement of 10 CFR 50.62 or staff positions related to implementation of that rule.

Control room ARI solenoid valve i

position indication would not be necessary in event of an ATWS, since l

actual control rod position indication is provided in the control room.

Valve position indication in the Auxiliary Relay Room will facilitate surveillance testing of the ARI system.

j

3.0 CONCLUSION

I The licensee's plans for relocating ARI position indication out of the control room to another location in the control building are acceptable.

Principal Contributor:

W. Long October 20, 1987 Dated: