ML20235G884

From kanterella
Jump to navigation Jump to search
Special Rept:On 870614,wide Range Gas Monitor (WRGM) Failed Automatic Check Source Test on High Range detector,1PC330. Check Source Damaged During Repairs.Parts & Installation of New Check Sorce Expected to Be Completed by 870715
ML20235G884
Person / Time
Site: Braidwood 
Issue date: 07/01/1987
From: Hunsader S
COMMONWEALTH EDISON CO.
To: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8707140416
Download: ML20235G884 (2)


Text

- _ _ _ _ _ _ - _.

. M h rn a :

Un at U.

.[", C Commonw alth Edison.

8s,, -

,f

_ ;) One First National Plaza, Chicago, Illinois

~

~#

m.

gg O

V Address Reply to: Post Office Box 767 Chicago, Illinois 60690 0767 fli}0tilTYROUTIgg-s.

T,,

p.

CN%1/

s- --JiII:

July 1, 1987 g;

qw l'

li[i-Oh j

[

L _, % p.,

hr

'Mr. A. Bert Davis Regional Administrator II.S. Nuclear Regulatory Commission Region III i

799 Roosevelt Road l

Glen Ellyn, IL 60137

Subject:

Braidwood Station Unit 1 Fourteen Day Special Report Accident' Monitoring Instrumentation NRC Docket No. 50-456 Reference (a): NUREG-1261, Technical Specification, dated May, 1987 Dear Mr. Davis Reference (a) Section 3.3.3.6, Action C requires Commonwealth Edison to submit a Special Report, pursuant to Specification 6.9.2, within j

fourteen (14) days that provides actions taken, cause of the inoperability and plans and schedule for restoring the Accident Monitoring Instrumentation channels to OPERABLE status. This is required in the event the subject instrumentation is inoperable for greater than seven (7) days.

Attachment (A) provides this report.

I please direct any questions concerning this matter to this office.

l Very truly yours, (f=:

l S. C. Hunsader Nuclear Licensing Administrator cc: Braidwood Resident Inspector 8707140416 070701 PDR ADOCK 05000456 S

PDR 3279K gee /

I JUL 6 BB7

l l

4 l

l 1

I ATTACHMENT (A)

)

i DESCRIPTION On June 14, 1987, at 1826, Wide Range Gas Monitor (WRGM) failed an 1

automatic check source test on its high range detector, IPC330.

J The check source test is a self-contained function to varify

/

detector operability. Since this test is the only approved method of determining detector operability, the WRGM was declared inoperable. The 7-day allowed outage time expired on June 21, 1987.

CAUSE The check source for IPC330 had become loose and fallen off. While attempting to repair it, the assembly containing the check source was damaged. The integrity of the check source itself was not compromised. A new check source assembly has been ordered from the vendor.

COMPLETION DATE Parts delivery and installation of the new check source is expected to be completed by July 15, 1987. This date is contingent upon the receipt of parts as scheduled.

3279K

.