ML20235G122

From kanterella
Jump to navigation Jump to search
Rev 1 to Monthly Operating Repts for June 1987
ML20235G122
Person / Time
Site: Calvert Cliffs  
Issue date: 06/30/1987
From: Behnke C
BALTIMORE GAS & ELECTRIC CO.
To:
Shared Package
ML20235G063 List:
References
NUDOCS 8709290449
Download: ML20235G122 (2)


Text

- - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

1 UNIT 1 OPERATING DATA REPORT I

Docket No. 50-317.

September 14, 1987 Prepared by C.Behnke

}

Telephone:(301)260-4871 OPERATING STATUS

~~~~~~~~~~~~~~~~

1. UNIT NAME Calvert Cliffs Unit 1
2. REPORTING PERIOD JUNE 1987 (Rev 1) 3.

LICENSED THERMAL POWER (MWT) 2700

4. NAMEPLATE RATING (GROSS MWe) 918 5.

DESIGN ELECTRICAL RATING (NET MWe) 845

6. MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 860
7. MAXIMUM DEPENDABLE CAP'Y (NET MWe) 825 8.

CHANGE IN CAPACITY RATINGS none 9.

POWER LEVEL TO WHICH RESTRICTED n/a

10. REASONS FOR RESTRICTIONS n/a Cumulative This month Year-to-Date to Date
11. HOURS IN REPORTING PERIOD 720 4,343 106,476
12. NUMBER OF HOURS REACTOR WAS CRITICAL 720.0 2766.2 82,537.9
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 3,019.4
14. HOURS GENERATOR ON LINE 720.0 2459.6 80,675.5
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 1,937,280 6,415,670 201,946,065
17. GROSS ELECTRICAL ENERGY GEN'TED(MWH) 646,161 2,159,203 66,849,196
18. NET ELECTRICAL ENERGY GENERATED (MWH) 619,871 2,066,395 63,815,605
19. UNIT SERVICE FACTOR 100.0 56.6 75.8
20. UNIT AVAILABILITY FACTOR 100.0 56.6 75.8
21. UNIT CAPACITY FACTOR (USING MDC NET) 104.4 57.7 72.8
22. UNIT CAPACITY FACTOR (USING DER NET) 101.9 56.3 70.9
23. UNIT FORCED OUTAGE RATE 0.0 39.2 10.0
24. SHUTDOWNS SCHEDULED OVER THE NEXT SIX MONTHS (TYPE, DATE AND DURATION):

None

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START-UP:

n/a Note: Line 21 " Cumulative" factor uses a weighted average.

h R

LF l

oce*************************************************************************

UNIT 2' OPERATING DATA REPORT

. coo *****************o*******************************************************

Docket No. 50-318 i

September 16, 1987 Prepared by C.Behnke l

Telephone:(301)260-4871 OPERATING STATUS

~~~-~~~~~~~~~~~~

1. UNIT NAME Calvert Cliffs Unit 2
2. REPORTING PERIOD JUNE 1987 (Rev 1) 3.-LICENSED THERMAL POWER (MWT) 2700
4. NAMEPLATE' RATING (GROSS MWe) 918 i
5. DESIGN ELECTRICAL RATING (NET MWe) 845
6. MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 860
7. MAXIMUM DEPENDABLE CAP'Y (NET MWe) 825
8. CHANGE IN CAPACITY RATINGS-none 9.

POWER LEVEL TO WHICH RESTRICTED n/a 10.' REASONS FOR RESTRICTIONS n/a Cumulative This month Year-to-Date to Date

11. HOURS IN REPORTING PERIOD 720 4,343 89,831
12. NUMBER OF HOURS REACTOR WAS CRITICAL 0.0 1,733.2 73,619.2
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1,296.6
14. HOURS GENERATOR ON LINE 0.0 1,727.3 72,547.3 15.-UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 0 4,443,141 182,759,996
17. GROSS ELECTRICAL ENERGY GEN'TED(MWH) 0 1,500,438 60,337,950
18. NET ELECTRICAL ENERGY GENERATED (MWH) 0 1,437,438 57,596,060
19. UNIT SERVICE FACTOR 0.0 39.8 80.8
20. UNIT AVAILABILITY. FACTOR 0.0 39.8 80.8
21. UNIT CAPACITY FACTOR (USING MDC NET) 0.0 40.1 77.7
22. UNIT CAPACITY FACTOR (USING DER NET) 0.0 39.2 75.9 l
23. UNIT FORCED OUTAGE RATE 0.0 1.4 5.8
24. SHUTDOWNS SCHEDULED OVER THE NEXT SIX MONTHS (TYPE, DATE AND DURATION):

None j

25. IF UNIT IS SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START-UP:

July 6, 1987 l

Note: Line 21 " Cumulative" factor no longer uses a weighted average.