Dated November 20, 1987 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION before the ATOMIC SAFETY AND LICENSING BOARD In the Matter of:

)

)

PUBLIC SERVICE COMPANY OF

)

Iboket Nos. 50 443-OL NEW HAMPSHIRE, et al.

)

Ibcket Nos. 50-444-OL

)

Seabrook Station, Units

)

On-site Dnergency Planning 1 and 2)

)

and Safety Issues AFFIDAVIT OF KENNETH RUBIN ON REACTOR COOLANT ACTIVITY AT 5 PERCENT POWER I, Kenneth Rubin, being duly sworn, depose and state:

1.

'I am employed by Westinghouse Electric Corporation as a Senior Engineer in Plant & Systems Licensing in the Nuclear Technology Systems Division of the Power Systems Business Unit.

2.

My professional qualifications are attached hereto and marked "A".

3 The purpose of my affidavit is to present information which supports use of a reduced reactor coolant activity level at 5% power based upon operating data from 35 nuclear power plants with a similiar fuel design.

4.

'Ihe primary parameter in the determination of the radiological consequences of a Steam Generator Tube Rupture is the reactor coolant activity level (I-131).

5.

The design basis event, a steam generator tube rupture at 100%

power, presented in the PSAR asstanes that the activity level in the reactor coolant is at the maximum dose equivalent I-131 reactor coolant specific acivity for a pre-accident iodine spike, of 60 h1 G

a uCi/gm permitted by the Technical Specifications. The results show that the doses'are within the 10CFR100 guidelines.

6.

At 5% power, the reactor coolant activity levels will be much lower than the maximum permitted by the Technical Specification limit.

7.

Actual Cycle 1 plant data for 35 reactor cores with the 17x17 fuel design (101 measurements) normalized to 100% power shows the following equilibrium RCS I-131 activity:

Highest reported reading........................... 0.06495 uCi/gm lowest reported reading.....................'....... 0.00006 uCi/gm Average reading.................................... 0.00429 uci/gm 8.

'Ihe high readings are a' result of small fuel defects. For the most part the operating data shows no fuel defects and the corresponding activity levels are less than 0.001 uCi/gm.

9.

The reactor coolant activity levels at 5% are obtained by dividing the normalized 100% power values by 20 since reactor coolant system activity is directly proportional to reactor power.

10. The highest activity level at 5% power becomes 0.00325 uC1/gm, the lowest is 0.000003 uCi/gm, and the average is 0.00021 uC1/gm. Since reactor coolant activity is reported to only 5 significant figures, the low level, when rounded to 5 figures, is less than 0.00001 uCi/gm.

Further affiant sayeth not

)

Kenneth Rubi'n SUBSCRIBED AND SWQRN to befor9 me this I day offuN'/X6@1987.

T-b [.

[

6

+

'/

NOTARY PUBLIC

"'* *'a w AcQ

I

c: e e c5): %.r:-r : acs

.i t

I k

Kenneth Rubin Py name is Eenneth Rutin. My business address is P.O. Box 355, Pittsburgh, ? pennsylvania 15230. I am e.mpicyed by the k'estinghcuse Electric Corporation as an Engineer in the Plant & Systems Evaluation Licensir.g group of the Nuclear Technology Systens Division.

s I began my career with Westinghouse in 1970 as a Technician.in the Systems Engineering Department where I perfcmed radiological sna'.ysis. I 3

transferred to the Nuclear Safety Departs.ent in 1978 and was promoted to

. Associate Engineer in 1979 and Engineer in 1984 I have ccapleted numerous assigrnents of increasing responsibility in the areu5'of fission product transport and con'.rcl. I am currently responsible for providir.g the technical lead for all cesign basis radiological safety ar.alyses, which includes steam generator tube ruptre and scurce temd. In this capacity, I was responsible for the development of the cu rent Westinghouse steam generator tube rupture radioactivity transport methodology which was approved by the Nuclear Regulatory Cemrissien in v

1987, and I have been regularly involved in the per:tmance of steam w

generater tube rupture analyses for W. westinghouse pressurized water reactors. I was awarded a Division Engineering Achievement Award in 1983 I nave one US patent in the area of centaircent spray system testing.

i

~f s1 a

D

-A-t l

'i

,/

h )-

fj o

-~ s y

January 4, 1988 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION before the ATOMIC SAFETY AND LICENSING BOARD

)

In the Matter of

)

)

PUBLIC SERVICE COMPANY OF

)

Docket Nos. 50-443-OL-1 NEW HAMPSHIRE, et al.

)

50-444-OL-1

)

(On-site Emergency (Seabrook Station, Units 1 and 2)

)

Planning Issues)

)

)

Notice of Appearance Pursuant to 10 CFR $ 2.713(b) the undersigned attorney enters her appearance in the above-captioned matter and in connection therewith provides the following information:

Name:

Deborah S.

Steenland Address:

Ropes & Gray 225 Franklin Street Boston, Massachusetts 02110 Telephone No.:

(617) 423-6100 Name and Address of Party:

PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE, ET AL.

New Hampshire Yankee Division P.

O.

Box 300

}'s Seabrook, New Hampshire 03874

O Admissions:

Supreme Judicial Court i

of Massachusetts l

l United States District Court for the District of Massachusetts United States Court of Appeals for the First Circuit b)tfu 6v Deborah S.

Steenland DOCHEiEO lc i

USNFC l

l l

'B8 JAN -5 P3 :22 <

CERTIFICATE OF SERVICE OFFICE C; EU tir,> <

Applicantsherein,herebycertifythatonJanuary4),1988,one of the attor$

h thd U T,, Thcu.as G.

Dignan, Jr.,

l I

mada service of the following documents by depos. ting copies thereof with Federal Express, prepaid, for delivery to (or j

wnere indicated, by depositing in the United States mail, first class postage paid, addressed to) the individuals linted below.

1.

Applicants' Memorandum In L:upport of Low Power Operation; 2.

Affidavit of Kenneth W.

Dow; 3.

Affidavit cC Winthrope B. Leland; 4.

SBN-168; 5.

SBN-486; i

6.

NUREG/CR-3054 "Closo-out IE Bulletin 81-03",

i

^

7.

Technical Specifications 3/4.4.5;

/

8.

Affidavi'.'df John N.

Esposito on tht) Ginna Tube Ruptur6 Event and the Design of.and Experience with

/

Model F St'eam Generators; 9

Affidavit of Grggory A. Kannt 10.

Af fidavit of John N.

Esposito on the North Anna Tube Rupture Event; 11.

Aff. davit of Peter S.

Littlefield;

12. ! Affidavit o'/. Ping Huang; 13.

Affidavit cf Kennetti Nubin; and 14.

Notice of Appearance (Deborah S. Steenland).

Administrative Judge Sheldon J.

Robert Carrigg, Chairman Wolfe, Esq.e Chairman, Atomic Board of Selectmen Safety and Licensing Board Panel Town Office U.S. Nuclear Fagulatory Atlantic Avenue Commission North Hampton, NH 03862 East, West Towers Build:<. reg 4350 East West Highway Bethesda, MD 20814 s

s

bT-Judge Emmeth A. Luebke Diane Curran, Esquire Atomic Safety and Licensing Andrea C.

Ferster, Esquire Board Panel' Harmon & Weiss 5500 Friendship Boulevard Suite 430 Apartment 1923N Washington, DC 20009 2001 S Street, N.W.

Chevy Chase, Maryland 20815 Dr. Jerry Harbour Stephen E. Merrill Atomic Safety and Licensing Attorney General Board Panel George Dana Bisbee U.S. Nuclear Regulatory Assistant Attorney General Commission Office of the Attoeney General East West Towers Building 25 Capitol Street 4350. East West Highway' Concord, NH 03301-6397 Bethesda, MD 20814 Atomic Safety and-Licensing Sherwin E. Turk, Esquire Board Panel Office of the Executive Legal U.S. Nuclear Regulatory Commission Director East West Towers Building U.S.

Nuclear Regulatory 4350 East West Highway Commission Bethesda, MD 20814 Tenth Floor 7735 Old Georgetown Road Bethesda, MD-20814

  • Atomic Safety and Licensing Robert A.

Backus, Esquire Appeal Board Panel Backus, Meyer & Solomon U.S. Nuclear Regulatory 116 Lowell Street Commission P.O.

Box 516 Washington, DC 20555 Manchester, NH 03105 Philip Ahrens, Esquire Mr. J.

P. Nadeau Assistant Attorney General Selectmen's Office Department of the Attorney 10 Central Road General Rye, NH 03870

-Augusta, ME 04333 Paul McEachern, Esquire Carol S. Sneider, Esquire Matthew T.

Brock, Esquire Assistant Attorney General Shaines & McEachern Department of the Attorney General 25 Maplewood Avenue One Ashburton Place, 19th Floor P.O. Box 360 Boston, MA 02108 Portsmouth, NH 03801 l

Mrs. Sandra Gavutic Mr. Calvin A.

Canney Chairman, Board of Selectmen City Manager

RFD 1 - Box 1154 City Hall Route 107 126 Daniel Street Kensington, NH 03827 Portsmouth, NH 03801 _ _ _ _ _ _

s:

  • Senator _Gordon J.

Humphrey Mr. Angie Machiros U.S.

Senate Chairman of the Board of Selectmen Washington, DC. 20510 Town of Newbury (Attn:

Tom Burack)

Newbury, MA 01950 l

E

  • Senator Gordon J. Humphrey Mr. Peter J. Matthews One Eagle Square, Suite 507 Mayor Concord, NH 03301 City Hall (Attn:

Herb Boynton)

Newburyport, MA 01950 Mr. Thomas F. Powers, III Mr. William S.

Lord Town Manager.

Board of Selectmen Town of Exeter Town Hall - Friend Street 10 Front Street Amesbury, MA 01913

.Exeter, NH 03833 H. Joseph Flynn, Esquire Brentwood Board of Selectmen Office of General Counsel RFD Dalton Road Federal Emergency Management Brentwood, NH 03833 Agency 500 C Street, S.W.

Washington, DC 20472 Gary W. Holmes,. Esquire Richard A. Hampe, Esquire Holmes & Ells Hampe and McNicholas 47 Winnacunnet Road 35 Pleasant Street Hampton, NH 03841 Concord, NH 03301 Mr. Ed Thomas Judith H. Mizner, Esquire FEMA, Region I Silverglate, Gertner, Baker, 442 John W. McCormack Post Fine, Good & Mizner Office and Court House 88 Broad Street Post Office Square Boston, MA 02110 Boston, MA 02109 Charles P. Graham, Esquire McKay, Murphy and Graham 100 Main Street Amesbury, MA 01913 n

Thomas C. Digniin, Jr.

(*= Ordinary U.S. First Class Mail.). _ _ _ -