APPENDIX A NOTICE OF VIOLATION Omaha Public Power District Docket:

50-285/87-14 Fort Calhoun Station License:

DPR-40 During an NRC inspection conducted on May 5-8, 1987, a violation of NRC requirements was identified.

The violation involved failure to follow procedure for radiographic techniques.

In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (1987), the violation is listed below:

Criterion V of Appendix B to 10 CFR Part 50 requires that activities affecting quality be prescribed by and accomplished in accordance with appropriate instructions, procedures, and drawings.

Professional Services Industries (PSI) Procedure 81-102, Revision 3, requires that a source side penetrameter be used for radiographic examination of the weld repairs to the girth and longitudinal welds in the emergency'feedwater storage tank.

Contrary to the above, PSI radiographed the weld repairs to two girth welds in the emergency feedwater storage tank, identified as welds G1 and G2, using film side penetrameters.

This is a Severity Level IV violation.

(Supplement I)(285/8714-01)

Pursuant to the provisions of 10 CFR 2.201, Omaha Public Power District is hereby required to submit to this office within 30 days of the date of the letter transmitting this Notice, a written statement or explanation in reply, including for each violation:

(1) the reason for the violation if admitted, (2) the corrective steps which have been taken and the results achieved, (3) the corrective steps which will be taken to avoid further violations, and (4) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending the response time.

Dated at Arlington, Texas this 29th day of June 1987 1

8707060438 B70629 DR ADOCK 050 25 i