Rev 32 to AR-403, PSA H Annunciator Response
ML20217M806
Person / Time
Site: Crystal River 
Issue date: 03/31/1998
From:
FLORIDA POWER CORP.
To:
References
AR-403, NUDOCS 9804080208
Download: ML20217M806 (195)


Text

Document Transmittal #: 91875 Date: 3/31/98 To:

NRC (DC DESK)

MAC: N/A Destination:

==

Description:==

Copy Copy Totals Document:

Revision:

Comment:

INFO CNTL MSTR AR0403 32 MINOR CHANGE 24 1

0 0

instn:ctions to the Addressee:

Plzse verify the document (s) received agrees with the above information.

h

/

Operations department must attach old document (s) or portions of document (s) superseded by the above to this transmittal.'

The signature indicates acknowledgment of receipt of the above document (s) and that documents have been updated. Retum signed and dated transmittal to Document Control within 15 working days of I

f trCnsmittaldate to mailcode:

[

NA1C i

Florida Power Corporation Document Control, NA1C Crystal River Energy Complex 4

n 15760 W. Power Line st.

g g y 2

().

Crystal River, FL 34428-6708 l

Signature of Addressee:

Date:

9804080208 980331 i

PDR ADOCK 05000302 P

Pm J

n

]

(MC) Rev. 32 Effective Date d d /"'f f INFORMATION L

ONLY ANNUNCIATOR RESPONSE AR-403 1

FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3 PSA H ANNUNCIATOR RESPONSE i

APPROVED BY Interpretation Contact fAid SS

& th A r (SIGNATURE ON FILE) k,)

DATE:

3 2 d hf K

/

INTERPRETATION CONTACT: Manager, Nuclear Plant Operations Support I

TABLE OF CONTENTS i

SECTION PACE

-1.0 PURP0SE.................................................................

1

2.0 REFERENCES

.....................q.......................................

1 2.1 IMPLEMENTING REFERENCES...................................

2.2 DEVELOPMENTAL REFERENCES..........'........................

......... 1

......... 1 3.0 PERSONNEL INDOCTRINATION................................................

2 4.0 INSTRUCTIONS............................................................

2 5. 0 FO L L OW-UP A CTIQNS..................................................

ENCLOSURE 1

Annunciator Response.............................................

3

/"

rt O

AR-403 Rev. 32 Page i

r 1.O PURPOSE.-

%)

'1.1 Establish a reference document for each Annunciator Window on the PSA-Z Lamp box.

1.2:

Establish operator actions for valid Annunciator alarms on the PSA-Z Lamp box.

1.3 Establish a reference to other procedures which address operator actions for valid Annunciator alarms on the P5A-Z Lamp box.

2.0 REFERENCES

2.1 IMPLEMENTING REFERENCES 2.1.1 E0P, Emergency Operating' Procedure 2.1.2 AP-250, Radiation Monitor Actuation 2.1.3 AP-1050, Flooding 2.1.4 CP-138, Secondary Water Chemistry Guidelines p) 1q, 2.1.5 OP-103B,. Heat-Up Cooldown Curves 2.1.6 SP-146, EFIC Monthly Functional Test 2.1.7 OP-302, RC Pump Operation 2.1.8 OP-301, Operation Of The Reactor Coolant System 2.1.9 AP-470, Loss of1 Instrument Air 2.1.10 OP-408, Nuclear Services Cooling System 2.1.11 OP-505, Radiation Monitoring System 2.1.12

.CP-152, Primary to Secondary Leakage Operating Guideline l2.1.13 AP-520, Loss of RCS Coolant or Pressure 2.2 DEVELOPMENTAL REFERENCES

'2.2.l.

INPO 90-021, Good Practice OP-217, Alarm Response Procedures 2.2.2 Arinunciator Window Engraving Drawing E-224-048 2.2.3 I-85-0004, Rev. 4 (EFW Tank Level Accuracy)

AR-403~-

Rev. 32 Page 1

2.2.4 MAR.87-10-27-01, Resolution of Back-Up Meteorological Tower

[--

Instrument Failures 3.0' PERSONNEL INDOCTRINATION' 3.1 The Annunciator Syster is. powered from VBDP-5 Breaker 28.

4.0 INSTRUCTIONS 4.1 Respond to' alarms on the PSA-Z Lamp box as indicated on Enclosure 1 Annunciator Response.

5.0' FOLLOW-UP ACTIONS None O.

O AR-403 Rev. 32 Page 2

i ENCLOSURE 1 (Page 1 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 l-l l

l GAMMA l

l RADIATION l

l HIGH I

I I

l EVENT POINT 1748 INDICATED CONDITION:

o RM-G1 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

,k)

REDUNDANT INDICATION WHICH WILL. VERIFY ALARM:

RM-G1 INDICATION AT RADIATION MONITORING PANEL.

o o RM-G1 INDICATION AT DETECTOR.

o RM-G1 RED ALARM LIGHT.

o RM-G1 HORN.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

REFER TO OP-505, RADIATION MONITORING SYSTEM.

o l DISCUSSION:

RM-CI MONITORS THE CONTROL ROOM. THE DETECTOR IS ON THE BACK WALL N j

TO THE ES RELAY ACTUATION CABINETS..THE REDAS SYSTEM MAY ALSO BE US TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-22 SENSING ELEMENT:

RADIATION MONITORING PANEL

'w -

i JAR-403 Rev. 32 Page 3

r~s

(

)

ENCLOSURE 1 (Page 2 of 190) v i

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 w

GAMMA RADIATION HIGH EVENT POINT 1750 INDICATED CONDITION'.

o RM-G2 RnsIATION LEVEL EXCEEDS HIGH SETPOINT.

O.

(s /

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

RM-C2 INDICATION AT RADIATION MONITORING PANEL.

o l OPERATOR ACTIONS FOR A VALID ALARM:

I'o INVESTICATE CAUSE OF HICH RADIATION.

NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

o i

DISCUSSION:

RM-C2 MONITORS THE CHEMICAL LABORATORY. THE DETECTOR IS LOCATED ON THE EAST WALL INSIDE THE CHEMICAL LABORATORY. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWINC 208-049-RM-23 SENSINC ELEMENT:

RADIATION MONITORING PANEL AR-403 Rev. 32 Page 4

p ENCLOSURE l' (Page 3 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA ?.-C1-01 H-01-01 GAMMA g

l RADIATION y

l HIGH l

I l

i J

EVENT POINT 1-752

\\

s INDICATED CONDITION:

o RM-G3 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

f\\

(/

lREDUNDANTINDICATIONWHICHWILL.VERIFYALARM:

RM-G3 INDICATION'AT RADIATION MONITORING PANEL.

o l

.!OPERATORACTIONSFORAVALIDALARM:

+

o INVESTIGATE CAUSE OF HIGH RADIATION.

NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o o _ OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

lo REFER TO OP-505, RADIATION MONITORING SYSTEM.

l DISCUSSION:

i l RM-G3 MONITORS THE PRIMARY SAMPLE ROOM. THE DETECTOR IS LOCATED ON SOUTH WALL INSIDE THE PRIMARY SAMPLE ROOM. THE REDAS SYSTEM MAY ALSO BF.

USED TO OBSERVE TREND INFORMATION.

t

REFERENCES:

DRAWING 208-049-RM-23 SENSING ELEMENT:

RADIATION MONITORING PANEL AR-403 Rev. 32 Page 5

ENCLOSURE 1 L ))

(Page 4 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 1

EEEEEE GAMMA J

RADIATION y

l HIGH a

I I

EVENT POINT 1754 INDICATED CONDITION:

o RM-G4 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

s C \\'

()

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

{

o RM-G4 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM.

INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o' REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION-

-lLOCATEDONTHEWALLOPPOSITETHEPAXPHONENE INTERMEDIATE BUILDING. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE T INFORMATION. -

REFERENCES:

DRAWING 208-049-RM-24 SENSING ELEMENT:

RADIATION MONITOR.iNG PANEL AR-403 Rev. 32 Page 6

-~3 ENCLOS E 'j, (Page 5 cf 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 GAMMA l

RADIATION l

HiGH I

I EVENT POINT 1756 INDICATED CONDITION:

o RM-GS RADIATION LEVEL EXCEEDS HIGH SETPOINT.

f}

(_/

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-GS INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS' FOR A VALID ALARM:

INVESTIGATE CAUSE OF HIGH RADIATION.

o o: NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

o DISCUSSION:

RM-G5 MONITORS THE WASTE CAS TANK VALVE ALLEY. THE DETECTOR IS LOCAT THE 95' AB. ON THE WALL IN THE WASTE GAS VALVE ALLEY, ADJACENT TO THE DETECTOR. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFO

~

REFERENCES:

DRAWING 208-049-RM-24 V

SENSING ELEMENT:

RADIATION MONITORING PANEL i

AR-403-Rev. 32 Page 7

1

.,.a....

ENCLOSURE 1 (Page 6 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01

.i g

y GAMMA RADIATION HIGH I

I i

EVENT POINT 1758 i

l i

INDICATED CONDITION:

o RM-C6 RADIATION LEVEL EXCEEDS HICH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-C6 INDICATION AT RADIATION MONITORING PANEL.

h OPERATOR ACTIONS FOR A VALID ALARM:

INVESTICATE CAUSE OF HICH RADIATION.

1 o

i

' o. NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORINC SYSTEM.

o i

I i

DISCUSSION:

i RM-C6 MONITORS THE MAKEUP TANK VALVE ALLEY. THE DETECTOR 15 LOCATED ON THE WALL NEAR THE ENTRANCE LOCKED CATE. THE REDAS SYSTEM MAY ALSOi BE USED TO OBSERVE TREND INFORMATION.

eq.

REFERENCES:

DRAWINC 208-049-RM-25 SENSING ELEMENT:

RADIATION MONITORING PANEL AR-403 Rev. 32 Page 8

(1 l

ENCLOSURE 1 (Page 7 of 190)

~ PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01

't:.

I GAMMA RADIATION y

HIGH I

II EVENT POINT 1760' INDICATED CONDITION:

RM-G7 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

o

(~)

(,,/

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

RM-C7 INDICATION AT RADIATION MONITORING PANEL.

o

!'OPERATORACTIONSFORAVALIDALARM:

l

o. INVESTICATE CAUSE OF HICH RADIATION.

NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATI0,N.

REFER TO OP-505. RADIATION MONITORING SYSTEM.

o DISCUSSION:

Ru-C7 MONITOR 5 THE.RC BLEED TAN % AREA. THE DETECTOR IS LOCATED ON

.NEAR THE ENTRANCE INSIDE THE LOCKED CATE ON THE 95' ELEVATION. THE RE SYSTEP MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

. f~)

)

(/

REFERENCES:

DRAWINC 208-049-RM-25 SENSING ELEMENT: RADIATION MONITORING PANEL i

AR-403 Rev. 32 Page 9

y J [,).-

ENCLOSURE 1 U

(Page 8 of-190)

PSA-Z ANNUNCIATOR RESPONSE i

PSA Z-01-01 H-01-01 0

I GAMMA

' RADIATION y

l HIGH I

I l

l EVENT POINT 1762 INDICATED CONDITION:

o RM-C8 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

Ah REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

RM-CB' INDICATION AT RADIATION MONITORING PANEL, o

1 OPERATOR ACTIONS FOR A VALID ALARM:

INVESTICATE CAUSE OF HICH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

i o

i 1

i l

DISCUSSION.

)

RM-C8 MONITORS THE RC BLEED TANK AREA. THE DETECTOR IS LOCATED O)

NEAR THE ENTRANCE INSIDE THE LOCKED GATE ON THE 119' ELEVATION. THE SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

'Q.

REFERENCES:

DRAWINC 208-049-RM-26 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 10

r' (9)

ENCLOSURE 1 t 'w (Page 9 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01

{ZZZZZE 4

l 1

i GAMMA h

RADIATION y

}

HIGH I

I I

I EVENT POINT 1764 i

INDICATED CONDITION:

RM-G9 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

l o

~ t

'(,

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

RM-G9 INDICATION AT RADIATION MONITORING PANEL.

o I

lOPERATORACTIONSFORAVALIDALARM:

INVESTICATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o

! c OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

REFER TO OP-505, RADIATION MONITORING SYSTEM.

o l

t d

DISCUSSION:

.RM-C9 MONITORS THE AREA OUTSIDE THE PERSONNEL HATCH. THE DETECTOR IS LOCATED ON THE WALL NEAR THE ENTRANCE INSIDE THE LOCKED CATE ON THE 11 ELEVATIO*.. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORM yo);

l Q' ).

REFERENCES:

DRAWING 208-049-RM-26 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403~

Rev. 32 Page 11

r'%

ENCLOSURE 1

()

(Page 10 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 l

GAMMA y

RADIATION l

l HIGH I

I I

EVENT POINT 1766 INDICATED CONDITION:

RM-G10 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

o b'

Gl REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

RM-CIO INDICATION'AT RADIATION MONITORING PANEL.

o 1

i OPERATOR ACTIONS FOR A VALID ALARM:

INVESTIGATE CAUSE OF HIGH RADIATION.

o l

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o o REFER TO OP-505, RADIATION MONITORING SYSTEM.

l DISCUSSION:

RM-CIO MONITORS THE MAKE-UP PUMP AREA. THE DETECTOR.'65 LOCATED ON THE WA NEAR THE ENTRANCE TO THE 'C' MAKE-UP PUMP (SOUTH ENTRANCE). THE REDAS 5YSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

ORAWING 208-049-RM-27 k/ -

SENSING ELEMENT:

RADIATION MONITORING PANEL AR-403 Rev. 32 Page 12

j F

I ENCLOSURE 1 s

y (Page 11 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 GAMMA y

RADIATION

-l HIGH I

l EVENT POINT 1768 INDICATED CONDITION:

RM-C11 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

o

?%

' ([

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

RM-C11 INDICATION AT RADIATION MONITORING PANEL.

o OPERATOR ACTIONS FOR A VALID ALARM:

INVESTICATE CAUSE OF HIGH RADIATION.

o o ' NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

.o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o. REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-C11. MONITORS THE DEBORATING DEMIN ROOM. THE DETECTOR IS LO WALL INSIDE THE DEMIN ROOM ON THE 119' ELEVATION. THE REDAS SYSTEM MA ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-27 SENSING ELEMENT: RADIATION MONITORING PANEL .AR-403-Rev. 32 Page 13

i ENCLOSURE 1 (Page 12 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 ( I I GAMMA g g RADIATION y l. HIGH I I I I EVENT POINT 1770 INDICATED CONDITION: RM-G12 RADIATION LEVEL EXCEEDS HIGH SETPOINT. o REDUNDANT' INDICATION WHICH WILL VERIFY ALARM: o RM-G12 INDICATION AT RADIATION MONITORING PANEL. I OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE CAUSE OF HIGH RADIATION. o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER TO OP-505, RADIATION MONITORING SYSTEM. o t ' DISCUSSION: RM-G12 MONITORS THE SPENT RESIN STORAGE TANK ROOM. THE DETECTOR IS LO IN THE DECANT-AND SLURRY PUMP ROOM JUST INSIDE THE LOCKED GATE ON THE WALL. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. .R (,)

REFERENCES:

. DRAWING 208-049-RM-28 SENSING ELEMENT: RADIATION MONITORING PANEL i AR-403 Rev. 32 Page 14 l

l l 1 ',C} ENCLOSURE 1 ' QJ (Page 13 of 190) PSA-Z ANNUNCIATOR' RESPONSE PSA-Z-01-01 H-01-01 I I I I I I GAMMA RADIATION HIGH I l l l EVENT POINT 1772 INDICATED CONDITION: RM-G13 RADIATION LEVEL EXCEEDS HIGH SETPOINT. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-G13 INDICATION AT RADIATION MONITORING PANEL. o i , OPERATOR ACTIONS FOR A VALID ALARM; INVESTIGATE CAUSE OF HIGH RADIATION. i o 'o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S). OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o o REFER TO 0P-505, RADIATION MONITORING SYSTEM. 1 l DISCUSSION: RM-G13 MONITORS THE DECONTAMINATION PIT AREA. THE DETECTOR IS LOCAT THE I43' ELEVA-TION, CLOSE TO THE STAIRWELL BY THE ECSTs. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND'INFORMATION.

REFERENCES:

DRAWINC 208-049-RM-28 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 15

(. 4,1 ENCLOSURE 1 (Page.14 of;190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 ll I y GAMMA g g RADIATION g l HIGH I I 1 I EVENT POINT 1774 INDICATED CONDITION: o RM-C14 RADIATION ' LEVEL EXCEEDS HIGH SETPOINT. b G REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I RM-CI4 INDICATION AT RADIATION MONITORING PANEL. o 1 OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION. o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o REFER TO OP-505, RADIATION MONITORINC SYSTEM. o l DISCUSSION: RM-CI4 MONITORS THE SPENT FUEL STORACE AREA. THE DETECTOR IS LOCATED O j_=THE'143' AB ON THE WALL OF THE. REACTOR BUILDING IN THE PASSAGEWAY TO THE SPENT FUEL SYSTEM FILTERS. THIS DETECTOR IS THE ONLY 5.T.S. AREA MONITOR AND 15 COMMONLY REFERRED TO AS THE "5 PENT FUEL CRITICALITY MONITOR". T REDA5 SYSTEM.MAY ALSO BE USED TO OBSERVE TREND INFORMATION. l [~

REFERENCES:

DRAWINC 208-049-RM-29 SENSING ELEMENT: RADIATION MONITORING PANEL i .g AR-403 ,j Rev. 32 Page 16

i ) L;~ ENCLOSURE 1 (Page 15 of 190) PSA-Z ANNUNCIATOR "ESPONSE PSA-2-01-01 H-01-01 I l y 9 GAMMA y RADIATION g HIGH I l EVENT POINT 1776' INDICATED CONDITION: RM-G15' RADIATION LEVEL EXCEEDS HIGH SETPOINT. o L! REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-G15 INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF.HICH RADIATION. o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S). c, ! c OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION, c; IF FUEL MOVEMENT IS IN PROGRESS. ENSURE FUEL'IS PLACED IN A SAFE CONDITION PRIOR TO PERSONNEL EXIT, 'o REFER TO OP-505. RADIATION MONITORING SYSTEM. I DISCUSSION: RM-C15 MONITORS THE SPENT FUEL AP,EA. THE DETECTOR IS LOCATED ON THE SPENT FUEL BRIDGE _AND MOVES WITH THE BRIDGE. THE REDAS SYSTEM MAY l BE ' USED TO OBSERVE TREND INFORMATION. j A

REFERENCES:

DRAWINC 208-049-RM-29 ) , SENSING ELEMEt(T: RADIATION MONITORING PANEL l AR-403, Rev. 32 Page 17

f y ' (m - ENCLOSURE 1 (Page 16 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 .i {___Z ZZ Z Z Z l l g GAMMA a g l RADIATION g l HIGH 1-1 I l EVENT POINT 1778 INDICATED CONDITION: RM-G16 RADIATION LEVEL EXCEEDS HIGH SETPOINT. o i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: i RM-G16 INDICATION AT RADIATION MONITORING PANEL. o 4 i OPERATOR ACTIONS FOR A VALID ALARM: i INVESTIGATE CAUSE OF HIGH RADIATION. o NOTIFY _ HEALTH PHYSICS TO MONITOR AFFECTED AREA (S), o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o IF FUEL MOVEMENT IS IN PROGRESS, ENSURE FUEL IS PLACED IN A SAFE o CONDITION' PRIOR TO PERSONNEL EXIT. REFER TO OP-.505, RADIATION MONITORING SYSTEM. o DISCUSSION: RM-G16 MONITORS THE FUEL TRANSFER AREA. THE DETECTOR IS LOCATED ON THE MAIN FUEL BRIDGE AND MOVES WITH THE BRIDGE. THE REDAS SYSTEM MAY ALSO USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-30 d SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 18

/

3 . ENCLOSURE 1 (Page 17 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01' H-01-01 1-GAMMA RADIATION l HIGH I .I EVENT POINT 1780 .f, INDICATED CONDITION: RM-G17 RADIATION LEVEL EXCEEDS HIGH SETPOINT. o O ' b, REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-G17 INDICATION AT RADIATION MONITORING PANEL. o t OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE CAUSE OF HIGH RADIATION. o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREACS). o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o o. REFER TO OP-505, RADIATION MONITORING SYSTEM. i 1 DISCUSSION: RM-G17 MONITORS THE 119' ELEVATION OF THE REACTOR BUILDING. THE DETECTOR IS:' LOCATED ON-THE STANCHION NEAR THE PERSONNEL HATCH. THE REDAS SYSTEM ALSO BE USED TO OBSERVE TREND INFORMATION. 1

REFERENCES:

DRAWING 208-049-RM-30 O- . V SENSINC ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 19 i

( w) r ENCLOSURE 1 (Page 18 of 190) PSA-Z ANNUNCIATOR RESPONSE P5A-Z-01-01 H-01-01 l GAMMA l RADIATION l HIGH I l EVENT POINT 1782 INDICATED CONDITION: RM-C18 RADIATION LEVEL EXCEEDS HIGH SETPOINT. o /^\\. k,) REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-G18 INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE CAUSE OF HIGH RADIATION. o o ' NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). DBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o VERIFY TRANSFER CANAL LEVEL AT DESIRED HEIGHT. o REFER TO OP-505, RADIATION MONITORING SYSTEM. o I DISCUSSION: RM-C18 MONITORS THE INCORE PIT AREA. THE DETECTOR IS LOCATED IN THE PIT .ON THE 164' ELEVATION NEAR THE TRANSFER CANAL. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. 7

REFERENCES:

DRAWINC 208-049-RM-31 l SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 20

ENCLOSURE 1 (Page 19 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 lH-01-01 GAMMA y j RADIATION g g HIGH 'l 1 h EVENT POINT 1784 INDICATED CONDITION: o ' RM-C29/30 RADIATION LEVEL EXCEEDS HIGH SETPOINT. / REDUNDANT INDICATION WHICH WILL VERIFY ALARM: c' RM-G29/30 INDICATION ON HVAC SECTION OF MAIN CONTROL BOARD. o SPDS ALPHA PACE. OPERATOR ACTIONS FOR A VALID ALARM:' o INVESTICATE CAUSE OF HIGH RADIATION. o ' NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.
o. REFER TO OP-505. RADIATION MONITORING SYSTEM.

l' 'l I l ! DISCUSSION: RM-C29/30 ARE THE REACTOR BUILDING HIGH RANCE POST ACCIDENT MONITORS. 'THE DETECTORS ARE LOCATE 0 ON THE TOP OF EACH 'D' RING AT THE 180' ELEVATION. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. i O

REFERENCES:

DRAWINC'208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING PANEL i -AR-403 Rev. 32 Page 21

o i l, ,2-c i ( I ENCLOSURE 1 wJ (Page 20 of 190)- PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-0I-02 9 GAMMA MONITOR WARNING EVENT POINT 1749 INDICATED CONDITION: o RM-Cl RADIATION LEVEL EXCEEDS WARNING SETPOINT OR RM-Cl RADIATION MONITOR FAILED LOW. o (q-) REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-CI INDICATION AT RADIATION MONITORING PANEL. o o RM-G1 INDICATION AT DETECTOR. o SPDS ALPHA PACE. L___ OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HIGH RADIATION OR, o MONITOR LOW READINC. o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S). o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. ) o REFER TO OP-505. RADIATION MONITORING SYSTEM. DISCUSSION: RM-C1 MONITORS THE CONTROL ROOM. THE DETECTOR IS ON THE BACK WALL NE TO THE ES RELAY ACTUATION CABINETS. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL CIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO iBE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING-208-049-RM-22 f (/'~S ' SENSING ELEMENT: RADIATION MONITORING PANEL ) l l s-AR-403 Rev. 32 Page 22

1 l l 'l ,s

(

) ENCLOSURE 1 (Page 21 of 190) l PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 l l GAMMA hAONITOR 1 WARNING i EVENT POINT 1751 i INDICATED CONDITION: RM-G2 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR, o RM-G2 RADIATION MONITOR FAILED LOW. l . g \\s REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-G2 INDICATION AT RADIATION MONITORING PANEL. o l OPERATOR ACTIONS FOR A VALID ALARM: i i INVESTICATE CAUSE OF HIGH RADIATION OR, -o 1 MONITOR LOW READING. ,l o' NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). I

  • u o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.
j. o REFER TO OP-505. RADIATION MONITORING SYSTEM.

DISCUSSION: RM-G2 MONITORS THE CHEMICAL LABORATORY. THE DETECTOR IS LOCATED ON THE EAST WALL'INSIDE THE CHEMICAL LABORATORY. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW hGLL CIVE THIS ALARM. THE REDAS SYST MAY ALSO BE'USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-23 .(,) ' SENSING' ELEMENT: RADIATION MONITORING PANEL AR-403 i Rev. 32 Page 23

,- g ENCLOSURE 1

-( j (Page 22 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 l GAMMA MONITOR WARNING EVENT POINT 1753 INDICATED CONDITION: o RM-G3 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR, i o RM-G3 RADIATION MONITOR FAILED LOW. 7"~g (,/ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-G3 INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM: i ~ INVESTIGATE CAUSE OF HIGH RADIATION OR. o MONITOR LOW READING. i o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S). o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.- REFER TO OP-505, RADIATION MONITORING SYSTEM. o DISCUSSION: RM-G3 MONITORS-THE. PRIMARY. SAMPLE ROOM. THE DETECTOR IS LOCATED ON THE i WALL INSIDE THE PRIMARY SAMPLE ROOM. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE l USED TO OBSERVE TREND INFORMATION. f x, i L

REFERENCES:

DRAWING 208-049-RM-23 kJ SENSING ELEMENT: RADIATION MONITORING PANEL i AR-403 Rev. 32 Page 24

(q ENCLOSURE 1 wJ (Page 23 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 l GAMMA MONITOR WARNING EVENT POINT 1755 INDICATED CONDITION: RM-G4 RADIATION LEVEL EXCEEDS WARNING SETFOINT OR, o o RM-G4 RADIATION MONITOR FAILED LOW. O \\ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: { RM-G4 INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE CAUSE OF HIGH RADIATION OR, .o MONITOR LOW READING. NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED ARE/.(5), o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. i o REFER TO OP-505, RADIATION MONITORING SYSTEM. o i DISCUSSION: RM-G4 MONITORS THE AUXILIARY BUILDING ENTRANCE HALLWAY. THE DETECTOR IS LOCATED ON THE WALL OPPOSITE THE PAX PHONE NEAR THE ENTRANCE TO THE INTERMEDIATE BUILDING. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-24 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 25

('g ENCLOSURE 1 () (Page 24 of 190) P5A-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR WARNING EVENT POINT 1757 INDICATED CONDITION: RM-G5 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR, o RM-C5 RADIATION MONITOR FAILED LOW. o I REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-C5 INDICATION AT RADIATION MONITORING PANEL. I o i { OPERATOR ACTIONS 'FOR A VALID ALARM: INVESTICATE CAUSE OF HIGH RADIATION OR, o MONITOR LOW READING. j NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o ~! REFER TO OP-505, RADIATION MONITORING SYSTEM. ,.o k lDISCUSSION: RM-C5 MONITORS THE WASTE CAS TANK VALVE ALLEY. THE DETECTOR IS LOCATE ON THE WALL OPPOSITE THE WASTE CAS COMPRESSOR ROOM. EITHER WARNING i SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. {

REFERENCES:

DRAWINC 208-049-RM-24 .(()j SENSING ELEMENT: RADIATION MONITORING PANEL i AR-403 Rev. 32 Page 26

[v--) ENCLOSURE 1 (Page 25 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR WARNING EVENT POINT 1759 INDICATED CONDITION: o RM-G6 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR RM-G6 RADIATION MONITOR FAILED LOW. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-G6 INDICATION AT RADIATION MONITORING PANEL. o i ' OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE CAUSE OF HIGH RADIATION OR, o MONITOR LOW READING. NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o

o. OB5ERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM. DISCUSSION: RM-G6 MONITORS THE MAKEUP TANK VALVE ALLEY. THE DETECTOR IS LOCATED ON THE. WALL NEAR THE ENTRANCE LOCKED GATE. EITHER WARNING SETPOINT EXCEE OR A DETECTOR FAILED' LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION,

REFERENCES:

DRAWING 208-049-RM 25 s SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 27

r'N LNILOSURE 1-( ) (Page 26 of 190) ~ PSA-Z' ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 .l i GAMMA MONITOR WARNING EVENT POINT 1761 INDICATED CONDITION: o RM-C7 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR .o RM-G7 RADIATION MONITOR FAILED LOW. (o) ' REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I i I o RM-C7 INDICATION AT RADIATION MONITORING pat i.., { l l OPERATOR ACTIONS FOR A VALID ALARM: I INVESTIGATE CAUSE OF HIGH RADIATION OR, o MONITOR LOW READINC. o - NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o - OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER TO OP-505. RADIATION MONITORING SYSTEM. o 1 DISCUSSION: RM-C7 MONITORS THE RC BLEED TANK AREA. THE DETECTOR IS LOCATED ON THE WA NEAR THE ENTRANCE INSIDE THE l.0CKED CATE ON THE 95' ELEVATION. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL CIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWINC 208-049-RM-25 A () SENSING ELEMENT: RADIATION MONITORINC. PANEL AR-403 Rev. 32 Page 28

, s' ENCLOSURE 1 ( (Page 27 of 190) PSA-Z ANNUNCIATOR' RESPONSE PSA-Z-01-02 H-01-02 .l 1 j I GAMMA MONITOR WARNING l EVENT POINT 1763 INDICATED CONDITION: o RM-C8 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G8 RADIATION MONITOR FAILED LOW. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-GS INDICATION AT RADIATION MON!f0 RING PANEL. o 4 1 OPERATOR ACTIONS FOR A VALID ALARM: ,.'o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING. NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o o L REFER TO OP-505, RADIATION MONITORING SYSTEM. l l DISCUSSION: RM-C8 MONITORS THE RC BLEED TANK AREA. THE DETECTOR. IS LOCATED ON THE WALL . NE AR THE ENTRANCE INSIDE THE LOCKED CATE ON THE 119' ELEVATION. EITHER. WARNINC SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDA5 SYSTEM MAY ALSO BE USED'TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-26 /~% \\, ). SENSINC ELEMENT: RADIATION MONITORING PANEL s_, ARi403. Rev. 32 Page 29

ENCLOSURE 1 \\ (Page 28 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 9 l l C GAMMA [ MONITOR WARNING EVENT POINT 1765 INDICATED CONDITION: o RM-C9 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR RM-C9 RADIATION MONITOR FAILED LOW. o O REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-C9' INDICATION AT RADIATION MONITORING PANEL. o l ' OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION OR, o MONITOR LO4 READINC. NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o i OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o REFER TO OP-505, RADIATION MONITORING SYSTEM. o i i DISCUSSION: i RM-C9 MONITORS THE PERSONNEL HATCH. THE DETECTOR 15 LOCATED ON THE NEAR THE ENTRANCE INSIDE THE LOCKED CATE ON THE 119' ELEVATION. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL CIVE THIS ALAR THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. l

REFERENCES:

DRAWINC 208-049-RM-26 SENSING ELEMENT: RADIATION MONITORING PANEL AR+403 Rev. 32 Page 30

'f-4)- ( ENCLOSURE 1 (Page 29 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 E l t GAMMA MONITOR - WARNING EVENT POINT 1767-INDICATED CONDITION: RM-C10 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G10 RADIATION MONITOR FAILED LOW. _o y ~. k._,l. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-G10 INDICATION AT RADIATION MONITORING PANEL. o ' OPERATOR ACTIONS FOR A VALID ALARM: o 'INVESTICATE CAUSE 0F HICH RADIATION OR, MONITOR LOW READING. j i !o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o . 1o REFER TO OP-505, RADIATION MONITORING SYSTEM. 1 DISCUSSION: RM-C10 MONITORS THE MAKE-UP PUMP AREA. THE DETECTOR IS LOCATED ON NEAR THE ENTRANCE TO THE 'C' MAKE-UP PUMP (SOUTH ENTRANCE). EITHER WARNING-SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. Ti SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-27 SEN5INC ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Pace 31

( ' ENCLOSURE 1 ( (Page 30 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA ] MONITOR WARNING l EVENT POINT 1769 i I i INDICATED CONDITION: RM-C11 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o o RM-C11 RADIATION MONITOR FAILED LOW. [d 'T i i lREDUNDANTINDICATIONWHICHWILLVERIFYALARM: RM-C11 INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE 0F HICH RADIATION OR,

o MONITOR LOA READINC.

NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5), o OBSERVE AREA MONITOR 5/ RECORDERS FOR TREND,INFORMATION. o . o REFER TO OP-505. RADIATION MONITORING SYSTEM. I ! DISCUSSION'. -)' 'RS-CII MONITORS THE DEBORATING DEMIN ROOM. THE DETECTOR IS LOCATED WALL INSIDE THE DEMIN ROOM ON THE -119' ELEVATION. EITHER WARNING SETPOINT EACEEDED OR A DETECTOR FAILED LOW WILL CIVE THIS ALARM. THE REDAS SYS MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWINC 208-049-RM-27 . () ij ' 5'ENSINC ELEVENT: RADIATION MONITORING PANEL l f r AR-403 - Rev. 32 Page 32

' M '\\. '( i ' ENCLOSURE 1 ,j (Page 31 ef 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 T l 1 'l GAMMA j MONITOR WARNING EVENT POINT 1771 1 ) INDICATED CONDITION: 4.- o'RM-C12 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-C12 RADIATION MONITOR FAILED LOW. 1 ' REDUNDANT. INDICATION WHICH WILL VERIFY ALARM:

l o RM-Cl2 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION OR, o MONITOR LOW READINC. NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o o 0BSERVE AREA MONITORS / RECORDERS FOR. TREND INFORMATION. o-REFER TO OP-505 RADIATION MONITORINC' 5YSTEM. DISCUSSION: I RM-C12 MONITORS THE SPENT RESIN STORACE TANK'RO)M. THE DETECTOR IS 1

j. IN THE DECANT'AND SLURRY PUMP ROOM JUST INSIDE THE LOCKED GATE. EITHER I

i' WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL CIVE THIS .THE REDAS SYSTEM MAY: ALSO BE USED TO OBSERVE TREND INFORMATION. l l

REFERENCES:

. DRAWINC 208-049-RM-28 SENSING ELEMENT _: RADIATION MONITORING PANEL - AR-403-Rev. 32 Page 33

i, .\\ '. 3 j?-S, _ ENdLOSURE1 t g,/ y (Page 32 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 i GAMMA l MONITOR WARNING EVENT POINT 1773 INDICATED CONDITION: o RM-G13 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-C13 RADIATION MONITOR FAILED LOW. j' S./ fREDUNDANTINDICATIONWHICHWILLVERIFYALARM: w l o RM-C13 INDICATION AT' RADIATION MONITORING PANEL. 1. OPERATOR ACTIONS FOR A VALID ALARM: D o INVESTICATE CAUSE OF HICH RADIATION OR, MONITOR LO4 READING. NOTIFY HEALTH PHYSICS TO MONITOR-AFFECTED AREA (5). o o OBSERVE AREA MONITOR 5/ RECORDERS FOR TREND INFORMATION. i i o REFER TO OP-505, RADIATION MONITORING SYSTEM. DISCUSSION: I ' RM-C13 MONITORS THE DECONTAMINATION PIT AREA. THE DETECTOR 15 LOCATE THE I43 ELEVATION. CLOSE TO THE STAIRWELL BY THE ECSTs. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL CIVE THIS ALARM. THE SYSTEM MAi ALSO BE USED TO OBSERVE TREND INFORMATION. f-s

REFERENCES:

DRAWINC 208-049-RM-28 k) SENSINC ELEMENT: RADIATION MONITORING PANEL ms 'AR-403 Rev. 32-Page 34

. /"'gH ENCLOSURE 1 .(,); (Page 33 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 s

GAMMA MONITOR WARNING EVENT POINT 1775 INDICATED CONDITION: RM-G14 RADIATION LEVEL EXCEEDS WARNING.5ETPOINT OR o o RM-C14 RADIATION MONITOR FAILED LOW.- .rh RED"NDANT INDICATION WHICH WILL VERIFY ALARM: o RM-CI4 INDICATION AT RADIATION MONITORING PANEL. 4 OPERATOR ACTIONS FOR. A VALID ALARM: o'INVESTICATE CAUSE OF HICH RADIATION OR, MONITOR L0r READINC. o NOTIF) HEALTH PHYSIC 'O MONITOR AFFECTED AREA (5). ci OBSERVE AREA MONITORS /RECORDtRS FOR TREND INFORMATION. REFER TO OP-505. RADIATION MONITORING SYSTEM. o DISCUSSION: Rv-CI4 MONITORS THE SPENT FUEL STORACE AREA. THE DETECTOR IS LOCATED ON THE I43' AB. ON THE_ WALL 0F THE REACTOR BUILDING IN THE PASSACEWAY TO THE r SPENT FUEL = SYSTEM FILTERS. THIS DETECTOR IS COMMONLY REFERRED TO AS THE -l "5 PENT FUEL CRITICALITY. MONITOR". THE REDAS SYSTEM MAY ALSO BE USED TO j:0BSERVETRENDINFORMATION. l

REFERENCES:

ORAWINC 208-049-RM-29 'g ws SENSINC ELEMENT: RADIATION MONITORING PANEL 'AR-403' Rev. 32 Page 35

l (Page 34 of 190) .PSA-Z ANNUNCIATOR' RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR L WARNING EVENT POINT 1777 INDICATED CONDITION: o RM-C15 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR RM-CIS RADIATION MONITOR FAILED LOW. o g REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o RM-C15 INDICATION AT RADIATION MONITORING PANEL. L- ' OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION OR, o -MONITOR LOW READING, ,.o-NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). !_ o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. [-o REFER TO.OP-505, RADIATION MONITORING SYSTEM. i. -[ DISCUS 5' ION: .RM-CIS MONITORS THE SPENT FUEL-AREA. THE DETECTOR IS LOCATED ON THE SPENT. FUEL BRIDGE AND MOVES WITH THE BRIDGE. EITHER WARNING SETPOIN EXCEEDED OR A DETECTOR FAILED LOW WILL CIVE THIS ALARM. THE REDAS l MAY. ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWINC 208-049-RM-29 ( SENSING ELEMENT: RADIATION MONITORINC PANEL 'AR-403. Rev. 32 Page 36

s (m ENCLOSURE 1 .i (Page 35 of 190) PSA-Z' ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 i GAMMA MONITOR WARNING l EVENT POINT 1779 INDICA' LED CONDITION: RM-G16 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G16 RADIATION MONITOR FAILED LOW. -o REDUNDANT INDICATION WHICH WILL-VERIFY ALARM: l -l o RM-CI6 INDICATION AT RADIATION MONITORING PANEL. I i jOPERATORACTIONSFORAVALIDALARM: o INVESTIGATE CAUSE OF HICH RADIATION OR, MONITOR LOW READING-. NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o l o OBSERVE AREA MONITORS / RECORDERS FOR' TREND INFORMATION. REFER TO OP-505. RADIATION MONITORING SYSTEM. q o t l DISCUSSION: RM-G16' MONITORS THE FUEL TRANSFER AREA. THE DETECTOR 15 LOCA MAIN FUEL BRIDGE AND MOVES WITH THE BRIDGE. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDA5 SYST MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-30 V)' -( .5ENSING ELEMENT: RADIATION MONITORING PANEL i AR-403 Rev. 32 Page 37

c (?N -_,); ENCLOSURE l (Page 36 of 190) <PSA-Z. ANNUNCIATOR RESPONSE P5A-2-01-02 H-01-02 GAMMA MONITOR - WARNING c EVENT POINT 1781 INDICATED CONDITIOfJ: RM-C17 RADIATION. LEVEL EXCEEDS WARNING SETPOINT OR o o RM-CI7 RADIATION MONITOR FAILED LOW. .p %'I jREDUNDANT. INDICATION WHICH WILL VERIFY ALARM: 1 i~ l o: RM-C17 INDICATION AT RADIATION MONITORING PANEL. OPERATOR ACTIONS. FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION OR, o MONITOR LO4 RE ADINC.- o NOTIF) HEAllH PHYSICS TO MONITOR AFFECTED AREA (5). o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER TO OP-505, RADIATION MONITORINC SYSTEM. o DISCUSSION: ) . Rv-CI7. MONITORS THE 119' ELEVATION OF THE REACTOR BUILDING. THE DETECTOR - 15 LOCATED ON THE STANCHION NEAR THE PERSONNEL HATCH. EITHER WARNING 5ETPOINT EXCEEDED OR A. DETECTOR FAILED LOW WILL CIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION,

REFERENCES:

DRAWINC 208-049-RM-30 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403-Rev 32 Page 38

i 1 (],/ : r 4 ENCLOSURE 1 i (Page 37 of 190) PSA-Z ANNUNCIATOR RESPONSE P5A-Z-01-02 H-01-02 P if GAMMA MONITOR . WARNING r EVENT POINT 1783 INDICATED CONDITION: RM-CIS RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-C18 RADIATION MONITOR FAILED LOW. o .,a REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-C18~ INDICATION AT RADIATION MONITORING PANEL. o {OPERATORACTIONSFORAVALIDALARM: INVESTICATE CAUSE OF HICH RADIATION OR,

o

.I-MONITOR LOW RE ADINC. oiNOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). j OBSERVE AREA MONITORS / RECORDERS.FOR TREND INFORMATION. ) 4 o o vERIF) TRANSFER CANAL LEVEL AT DESIRED HEICHT. 4 1 o ' REFER TO OP-505, RADIATION MONITORING SYSTEM. DISCUSSION: RM-CIS MONITORS THE INCORE PIT AREA. THE' DETECTOR IS LOCATED IN THE-PIT .ON THE' 164' ELEVATION NEAR THE TRANSFER CANAL. EITHER WARNING SETPOINT EXCEEDED OR A' DETECTOR' FAILED LOW WILL CIVE THIS ALARM. THE REDAS SYSTE MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWINC' 208-049-RM-31 -f SENSINC ELEMENT: RADIATION MONITORINC PANEL . AR-403 Rev. 32 f Page 39

a .i-. fs ( ENCLOSURE 1-(Page 38 of 190) PSA-Z ' ANNUNCIATOR RESPONSE PSA'Z-01 H-01-02 J i GAMMA MONITOR. . WARNING - EVENT POINT 1785 INDICATED CONDITION: RM-C29/30 RADIATION LEVEL EXCEEDS WARNING SETPOINT(5) OR o RM-C29/30 RADIATION MONITOR (5) FAILED LOW. o {N-.- REDUNDANT INDICATION WHICH WILL-VERIFY ALARM: o RM C29/30 INDICATION ON HVAC SECTION OF MAIN CONTROL BOARD, o~ SPDL ALPHA PACE. ' OPERATOR ACTIONS FOR A VALID ALARM: o INVESTICATE CAUSE OF HICH RADIATION OR MONITOR (5) LOW READINC. po NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). L. o.0BSERVE AREA MONITORS / RECORDERS FOR TREND-INFORMATION, L i o ~ VERIFi1 TRANSFER. CANAL LEVEL AT DESIRED HEIGHT. o-REFER TO OP-505. RADI ATION MONITORING SYSTEM. 1 (DISCUSSION: 1 RM-C29/30 ARE'THE REACTOR BUILO'NC HICH RANCE POST ACCIDENT MONITORS THE DETECTORS ARE LOCATED ON.THE TOP OF EACH'D' RING AT THE 180' ELEVATION. EITHER' WARNING SETPOINT(5) EXCEEDED OR A DETECTOR FAILED LOW. j -l WILL CIVE THIS. ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO.0BSERVE TREND <INFORMATION. / 'N

REFERENCES:

DRA41NC 208-049-RM-32 ~ l SENSING ELEMENT: RADIATION MONITORING PANEL 'AR-403 R e v.. 32 Page 40

t s -g ENCLOSURE 1 (j (Page 39 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-05 H-01-05 .i MN STM LINE A/B HH3H RAD MONITOR Fall I - EVENT POINT 1977 INDICATED CONDITION: I o RM-C25/26/27/28 RADIATION LEVEL EXCEEDS ALARM SETPOINT, OR o RM-C25/26/27/28 RADIATION MONITOR FAILED LOW. O REDUNDANT INDICATION'WHICH WILL VERIFY ALARM: 1o RM C25/26/27/28 INDICATION ON HVAC SECTION OF MAIN CONTROL BOARD. [ o AUDIBLE INDICATION ON RADIATION MONITOR (5)

o SPDS ALPHA. PACE.

j ~ + ODERATOR ACTIONS FOR A VALIDt ALARM: INVESTICATE CAUSE OF,HIGH RADIATION OR o LOA MONITOR READINC. f NOTIFE HEALTH PHYSICS TO MONITOR AFFECTED AREA (5). o

o. REFER TO E0P-06. STEAM CENERATOR TUBE RUPTURE.

i o REFER TO OP-505. RADIATION MONITORING SYSTEM. t i , DISCUSSION:' I' . RM-C25/28 MONITOR THE ATMOSPHERIC DUMP LINES MSV-25/Al AND MSV , Rv-C26/27 MONITOR THE MAIN STEAM LINES B1 AND A2 RESPECTIVELY. :THE DETECTORS ARE ALL LOCATED ON THE 119' ELEVATION OF THE INTERMEDIATE BUILDINC ON THEIR RESPECTIVE STEAM LINE. EITHER RADIATION SETPOINT ENCEEDED OR A DETECTOR FAILED LOW CAN'CIVE THIS ALARM. } l

REFERENCES:

DRAWINC 208-049-RM-47i SENSING ELEMENT: RADIATION MONITORING PANEL ( .AR-403-Rev. 32 Page 4I l i

C 'i ~+s ENCLOSURE 1 }g,) (Page 40 of 190). -PSA-Z' ANNUNCIATOR RESPONSE PSA-2-01-07 H-01-07 H DO STOC TANK. LEVEL ' HIG HlLOW. l-EVENT POINT 1512 INDICATED CONDITION: D0. 5TORACE TANK LEVEL >97" H;0 AS SEN5ED BY DO-4-L5 o

e
k.

REDUNDANT INDICATION WHICH WItt VERIFY ALARM: ). pr i OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH LEVEL. o o NOTIFN 5ECONDARY PLANT OPERATOR TO OBSERVE LOCAL LEVEL INDICATOR. I i DISCUSSION: THE-DO STORACE TANK HAS AN AUTO FILL FEATURE. IF THE LEVEL 15 HICH AND RISING THE FILL VALVE MAY BE STUCK OPEN.

REFERENCES:

DRAWINC 208-022-00-07 SENSING ELEMENT: DO-4-L5 AR-403 Rev. 32 e Page 42

(']. i ENCLOSURE 1 (f (Page 41 of 190) 'PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-07 H-01-07 DO STOR TANK LEVEL HIGHILOW EVENT POINT 1520 INDICATED CONDITION: o DO STORACE TANK LEVEL <33" H 0 A5 SENSED BY D0-3-L5 REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I OPERATOR ACTIONS FOR A VALID ALARM: I 'I'o INVESTICATE CAUSE OF' LOW LEVEL. NOTIFY SECONDARY PLANT OPERATOR TO OBSERVE LOCAL LEVEL INDICATOR. 'o i F DISCUSSION: i THE 00 STORACE. TANK _HAS AN~ AUTO FILL FEATURE. IF THE LEVEL IS LOW AND NOT RISING THE FILL VALVE MAY BE STUCK CLOSED, OR DO WATER FROM UNITS I/2 WATER TREATMENT BUILDING IS NOT AVAILABLE. CONTACT UNITS 1/2 TO INVESTICATE." hg

REFERENCES:

DRAWINC.208-022-DO-07 SENSINC ELEMENT: 00-3-L5 r p,

AR-403 Rev. 32 Page 43 i

(

l}(N ENCLOSURE 1 1 x (Page 42 of 190). PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 I I I i ATMOSPHERIC RADIATION l l HIGH I i I I EVENT POINT'1712 INDICATED CONDITION: i RM-Al' RADIATION LEVEL EXCEEDS HICH SETPOINT. o i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: '.O RM-Al INDICATION AT RADIATION MONITORING PANEL. o SPDS ALPHA PACE, i i OPERATOR' ACTIONS FOR A VALID ALARM: I o REFER TO AP-250. INVESTICATE CAUSE OF HICH RADIATION. .o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o c REFER T0:0P-505, RADIATION MONITORING SYSTEM, l DISCUSSION: u 'Rv-AI MONITORS THE REACTOR BUILDINC PURCE EXHAUST DUCT. THRE DETECTORS ARE USED, PARTICULATE.. IODINE. AND CAS. ANY ONE OF THESE CHANNEL 5 CAN CIVE,THIS ALARM. THE REDA5' SYSTEM MAY ALSO BE USED TO OBSERVE TREND 11NFORMATION. l

q j

REFERENCES:

DRAWINC 208-049-RM-16 O SENSINC ELEVEM:' RADIATION MONITORING PANEL i AR-403 i Rev. 32 Page 44

I i ( ENCLOSURE 1 4 (Page'43 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01' l g ATMOSPHERIC g } RADIATION g } HIGH I I l-l- EVENT POINT 1715-INDICATED CONDITION: RM-A2 RADIATION LEVEL EXCEEDS HICH SETPOINT. o (~% l b REDUNDANT ' INDICATION WHICH WILL VERIFY ALARM: i 'o RM-A2 INDICATION AT RADIATION MONITORINC' PANEL.' o SPDS ALPHA PACE. .j - l-l -- OPERATOR ACTIONS FOR A VALID ALARM: 4 ~o REFER TO AP-250. .I o INVESTICATE CAUSE OF HICH RADIATION. l o _0BSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION

.o REFER TO OP-505, RADIATION MONITORING SYSTEM.

7 L ! DISCUSSION: RM-A2 MONITORS THE AUXILIARY BUILDINC PURCE EXHAUST DUCT. THREE DIFFERENT DETECTORS ARE USED, PARTICULATE, IODINE AND GAS. ANY ONE OF THESE CHANNELS l CAN CIVE THIS ALARM.-THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND F INFORMATION.' i i ,r

REFERENCES:

DRAWINC 208-049-RM-16 -( '\\ SENSINC ELEMENT: ~ RADIATION MONITORING PANEL AR-403' Rev. 32 Page 45

i

73 ENCLOSURE 1 Q

(Page 44 of 190) PSA-Z' ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 i s I 1 ZZZZZ l I ATMOSPHERIC g g. RADIATION l }. HIGH I I I I EVENT POINT 1718 INDICATED CONDITION: I i RM-A3_ RADIATION LEVEL _ EXCEEDS HICH SETPOINT. ~ o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: e. RM-A3 INDICATION AT RADIATION MONITORING PANEL. 4 OPERATOR ACTIONS FOR A VALID ALARM: 1 o REFER TO AP-250, INVESTICATE CAUSE-0F HICH RADIATION. o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. i o I o REFER TO OP-505, RADI ATION MONITORIf4C SYSTEM. t { DISCUSSION: Rv-A3, MONITORS AUXILI ARY BUILDING EXHAUST FROM SAMPLE AREA 'D', THE s WASTE CAS COMPRESSOR ROOM, THE WASTE CAS VALVE ALLEY, AND AD]OINING AREAS. THIS DETECTOR ONLY HAS A CA5 CHANNEL. THE REDA5 SYSTEM MAY ALSO s. BE USED TO 085EP.VE TREND INFORMATION. j i

REFERENCES:

DRAWINC 208-049-RM-17 SENSING ELEMENT:. RADIATION MONITORING PANEL i l l AR-40,3 Rev. 32 Page 46 i

ENCLOSURE 1-r: (Page-45 of 190). PSA'Z' ANNUNCIATOR RESPONSE PSA-2-02-01 H-02-01 I I .g g ATMOSPHERIC RADIATION ) } HIGH I I l l ' EVENT POINT 1721 INDICATED CONDITION: 1 o RM-A4 RADIATION LEVEL EXCEEDS HICH SETPOINT. s X_/ - i REDUNDANT INDICATION WHICH WILL VERIFY' ALARM: -l o RM-A4 INDICATION AT RADIATION MONITORING PANEL. 4 OPERATOR' ACTIONS FOR ' A VALID' ALARM: o REFER TO AP-250. INVESTICATE CAUSE OF HICH RADIATION. o 10BSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION o REFER TO OP-505. RADIATION MONITORING SYSTEM. o DISCUSSION: h ..Rv-A4 MONITOR 5 THE SPENT FUEL AREA EXHAUST. THIS DETECTOR ONLY HAS A j CHAM EL. THE REDA5 SYSTEM MAY'AL50 BE USED_;TO OBSERVE TREND INFORMATION.- I l gj '} REFERENCE 5iDRAWINC 208-049-RM-17 fCSENSING-ELEMENT: RADIATION MONITORING PANEL l AR-403 Rev. 32 1 Page 47 i

1 j~ ENCLOSURE 1 (Page 46 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 I I I I ATMOSPHERIC ( RADIATION j j HIGH I I I I EVENT POINT 1724-4 n: INDICATED CONDITION: o RM-A5 RADIATION LEVEL EXCEEDS HIGH SETPOINT, i i i REDUNDANT INDICATION WHICH WILL VERIFY AL/RM: o RM-A5 INDICATION AT RADIATION MONITORING PANEL. o SPDS ALPHA PACE. i lOPERATORACTION5'FORAVALIDALARM: 1 } o REFER ~TO AP-250, l.o INVESTICATE CAUSE OF HICH RADIATION. { o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. kEFER TO OP-505. RADIATION MONITORING SYSTEM. o , DISCUSSION: RM-A5' MONITORS THE CONTROL COMPLEX RETURN DUCT. THREE DIFFERENT ARE USED, PARTICULATE IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN GIVE THIS ALARM. THE 'REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. * /- g

REFERENCES:

DRAWING 20S-049-RM-18 \\- SENSING ELEMENT: RADIATION MONITORING PANEL ARs403 Rev. 32 Page 48 - i

t /~N ENCLOSURE 1 kj (Page 47 of 190) h PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 l l l l ATMOSPHERIC l l RADIATION I l HIGH ~ l l l l 1 EVENT POINT 1727 l INDICATED CONDITION: o RM-A6 RADIATION LEVEL EXCEEDS HICH SETPOINT. i /'s ' REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-A6LINDICATION AT RADIATION MONITORING PANEL. .o o'.SPDS ALPHA PACE. l OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION. o o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER TO OP-505, RADIATION MONITORING SYSTEM. o DISCUSSION: RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE, SAMPLE POINTS ARE EITHER AHF 38 DUCT, OR THE RB ATMOSPHERE DIRECTLY. IT IS NORMALLY LINED UP TO l THE DUCT OF AHF-3B. IT CAN ALTERNATELY BE LINED UP TO SAMPLE THE RB l ATMO5PHERE DIRECTLY PER OP-417. TWO DIFFERENT DETECTORS ARE USED, ~ PARTICULATE /EETA AND CAS. ANv' ONE OF THESE CHANNELS CAN CIVE THIS ALARM. .THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. M

REFERENCES:

DRAWINC 208-049-RM-I8 4 SENSING ELEMENT: RADIATION MONITORING PANEL '-AR-403. Rev. 32 Page 49

O ENCLOSURE 1 (Page 48 of 190) PSA-Z ANNUNCIATOR RESPONSE P5A-Z-02-01 H-02-01 I I ATMOSPHERIC - l RADIATION l l HIGH ' I I I EVENT POINT 1730 INDICATED CONDITION: o ' RM-A7 RADIATION LEVEL EXCEEDS HICH SETPOINT. fREDUNDANTINDICATIONWHICHWILLVERIFYALARM: i j RM-A7 INDICATION AT RADIATION MONITORING PANEL. o 1 I OPERATOR ACTIONS FOR A VALID ALARM: o INVESTICATE CAUSE OF HICH RADIATION. OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o REFER TO'OP-505, RADIATION MONITORING SYSTEM. o ' DISCUSSION: Re-A7 MONITORS THE AHF-44A/B DISCHARCE AIR, THEREFORE THE ATMOSPHERES OF THE PRIMARY SAMPLE ROOM, PRIMARY SAMPLE ROOM SAMPLE HOOD, RADIO CHEMISTRY LAB SAMPLE HOODS, AND/OR PASS SYSTEM VALVE ALLEY MAY HAVE HIGH CASE 005 ACTIVITY. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. )

REFERENCES:

DRA4INC 208-049-RM-19 lSENSINGELEMENT:RADIATION MONITORING PANEL AR-403 Rev. 32 Page 50

I ~ p. \\ ENCLOSURE 1

(

(Page 49 of 190) l PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 l l g g ATMOSPHERIC RADIATION ~ g j HIGH I I l l \\ l ^ EVENT POINT 1733 i INDICATED CONDITION: RM-A8 RADIATION LEVEL EXCEEDS HICH SETPOINT. o O h REDUNDANT INDICATION WHICH WILL VERIFY ALARM: . o RM-AS INDICATION AT RADIATION MONITORING PANEL, [0PERATORACTIONSFORAVALIDALARM: l- ! o INVESTICATE CAUSE OF HICH RADIATION. 3 o', OBSERVE AREA MONITOR 5/RECDRDERS FOR TREND INFORMATION. l o REFER TO OP-505, RADIATION MONITORING SYSTEM. i -t DISCUSSION: .j ' RM-AB MONITORS THE AUXILIARY BUILDINC EXHAUST UPSTREAM OF THE PENET FOR THE FUEL HANDLINC FLOOR-EXHAUST THE REDAS SYSTEM MAY ALSO BE OBSERVE TREND INFORMATION. f

REFERENCES:

'DRAWINC 208-049-RM-19 j

l SENSINC ' ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 51

lf"N ENCLOSURE 1 ' (/. (Page 50 of 190) i PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 ,___b_ I l l ATMOSPHERIC g RADIATION g p HIGH I I L. I I EVENT POINT 1736 INDICATED CONDITION: RM-All RADIATION LEVEL EXCEEDS HICH SETPOINT. o \\fb- .lREDUNDANTINDICATIONWHICHWILLVERIFYALARM: \\ 1. I o RM-AII INDICATION AT RADIATION MONITORING PANEL. l , OPERATOR ACTIONS FOR A VALID ALARM: l 1 l o INVESTICATE CAUSE OF.HICH RADIATION. lo IF WASTE CAS RELEASE IN PROGRESS, NOTIFY PRIMARY PLANT OPERATOR TO ENSURE WCDT RECYCLE VALVES AND RELEASE VALVE ARE CLOSED. o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. i o-REFER TO OP-505. RADIATION MONITORING SYSTEM.

i. ;

~ DISCUSSION: i Rv-AII MONITORS THE AUXILIARY BUILDING EXHAUST PENETRATION FOR THE WASTE ) ( CAS RELEASE PATH. THE WCDT. RECYCLE VALVE 5 ARE WDV 393/394/395 AND THE i RELEASE VALVE IS WDv-439. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORYATION. ]

REFERENCES:

DRAWINC 208-049-RM-20 d 5ENSING ELEMENT: ' RADIATION MONITORING PANEL l-l AR-403, Rev. 32 Page 52 {

1 l t /~N ENCLOSURE 1 ( (Page 51 of 190) PSA-Z ANNUNCIATOR RESPOWSC PSA-2-02-01 H-02-01 ) I I ATMOSPHERIC l l RADIATION l J, HIGH I I I I ) i EVENT POINT 1738 i INDICATED CONDITION: RM-A12 RADIATION LEVEL EXCEEDS HICH SETPOINT. o ,ym REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o RM-Al2 INDICATION AT RADIATION MONITORING PANEL. 1 o SPDS ALPHA PACE., o MAIN STEAM LINE' RAD MONITORS RMG-25, RMC-26 RMG-27, AND /OR RMC-28 READ HICHER THAN NORMAL. 1 OPERATOR ACTIONS FOR A VALID ALARM: i o. REFER TO E0P-06, STEAM CENERATOR TUBE RUPTURE. L i 'o INVESTICATE CAUSE OF HICH RADIATION. o OB5ERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER T0.0P-505, RADIATION MONITORING SYSTEM. o l. l DISCUSSION: .RM-A12 MONITORS THE AUXILIARY BUILDING EXHAUST PENETRATION FOR SECONDARY PLANT CONDEN5ER OFF GAS, THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND'INFORMATION. l ,h

REFERENCES:

DRAWINC 208-049-RM-20 i 5EN5ING ELEMENT: ^ RADIATION MONITORING. PANEL I ,AR;403 Rev. 32 Page'53 L

l Q("N ENCLOSURE 1 (Page 52 of 1907 PSA-Z ~ ANNUNCIATOR RESPONSE P5A-Z-02-01' H-02-01 l l ATMOSPHERIC RADIATION j j HIGH I I I l EVENT POINT 1742 INDICATED CONDITION: o RM-A14 RADIATION LEVEL EXCEEDS HICH SETPOINT. O i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-A14. INDICATION AT RADIATION MONITORINC PANEL. o h d OPERATOR ACTIONS FOR A VALID ALARM: i o : INVESTIGATE CAUSE OF HICH RADIATION, o 0BSERVE AREA MONITORS / RECORDER 5 ' FOR TREND INFORMATION. i REFER TO OP-505, RADIATION MONITORING SYSTEM. o k l DISCUSSION: RM-AI4 IS A PORTABLE MONITOR, NORMALLY LOCATED NEAR THE PRIMARY SAMPLE . LABORATORY. THIS MONITOR IS NOT NORMALLY ENERCIZED. THE REDA5 SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

p-

REFERENCES:

DRAWINC 208-049-RM-21 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 54

p. -j f] ENCLOSURE 1 () (Page 53 of 1901 \\ PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02 H-02-01 .i l l ATMOSPHERIC j . R ADIATION l l HIGH l j I EVENT POINT 1745 i INDICATED CONDITION:

o. RM-AIS RADIATION LEVEL EXCEEDS HICH SETPOINT.

j () REDUNDANT INDICATION WHICH WILL VERIFY ALARM: s RM-A15 INDICATION AT-RADIATION MONITORING PANEL. .o OPERATOR. ACTIONS FOR A VALID ALARM: { o INVESTICATE. CAUSE OF HICH RADIATION. o ' 0BSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER TO OP-505, RADIATION MONITORING SYSTEM. o ' DISCUSSION: RM-A15 IS A PORTABLE MONITOR, NORMALLY LOCATED NEAR THE DECONTAMINATION PIT ON THE SPENT FUEL FLOOR. THIS MONITOR IS NOT NORMALLY ENERCIZED. THE REDA5 SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFOPMATION. I j

REFERENCES:

DRAWINC 208-049-RM-22 i SEN5ING ELEMENT: RADIATION MONITORINC PANEL 4 'AR-403 .Rev. 32' Page 55

,. f-ENCLOSURE I (Page 54 of 190)- PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1713 INDICATED CONDITION: RM-AI RADIATION LEVEL EXCEEDS WARNINC SETPOINT, OR o o RM-AI RADIATION MONITOR FAILED LOW p (_- REDUNDANT INDICATION WHICH WILL VERIFY ALARM: !o RM-Al INDICATION AT RADIATION MONITORING PANEL. 1 o SPDS ALPHA PACE. I OPERATOR ACTION 5' FOR A VALID ALARM: ,. o INVESTICATE CAUSE OF HICH RADIATION, OR LO4 MONITOR READINC. OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o

o. REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION: i Rv-Al MONITORS THE REACTOR BUILDING PURCE EXHAUST DUCT THREE DIFFERENT DETECTORS ARE USED, PARTICULATE, IODINE AND CAS, ANY ONE OF THESE CHANNELS CAN CIVE THIS ALARM, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED j LO4 THE REDAS 5YSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. 2 l REFERENCE 5; DRAWINC 206-049-RM-16 ] SENSINC ELEMENT: RADIATION MONITORING PANEL l AR-403 Rev. 32 Page 56 j 1

i. ..(7 ENCLOSURE 1 (j (Page 55 of 190) PSA-Z ANNUNCIATOR RESP 0N'SE PSA-Z-02-02 H-02-02 ATMOSPHERIC MONITOR j WARNING L_. EVENT POINT 1714 INDICATED CONDITION: RM-Al RADIATION.-MONITOR PUMP FLOW ABOVE NORMAL (LR LESS THAN 5 SCFM. o . f'N - 'V' REDUNDANT. INDICATION WHICH WILL VERIFY ALA.RM: RM-Al FLOW INDICATION AT RADIATION MONITORING PANEL. o i i J I i

OPERATOR ACTIONS FOR A VALID ALARM

) o INVESTICATE CAUSE OF RADIATION PUMP FLOW PROBLEM. REFER TO OP-505, RADIATION MONITORING SYSTEM. o i i t '! DISCUSSION: RM ' ' m0NITORS THE REACTOR BUILDING PURCE EXHAUST DUCT. THREE DIFFERENT s10R5 ARE USED, PARTICULATE, IODINE AND GAS. EITHER A HIGH OR LOW FLOW l .L 4 CIVE THIS ALARM. t-l

REFERENCES:

.DRAWINC 208-049-RM-01 SENSING ELEMENT: RADIATION MONITORINC. PANEL 1 -AR-403 Rev. 32 i Page 57 e:

I n [Q T ENCLOSURE 1 (Page 56 of 190) P5A-Z ANNUNCIATOR RESPONSE P5A-Z-02-02 a-02-02 f .~ ATMOSPHERIC MONITOR WARNING EVENT POINT 1716 INDICATED CONDITION: RM-A2 RADIATION LEVEL EXCEED 5 WARNING SETPOINT, OR. o o RM-A2 RADIATION MONITOR FAILED LOW ' REDUNDANT INDICATION WHICH'WILL VERIFY ALARM: RM-A2 INDICATION AT RADIATION MONITORING PANEL, o l-i L OPERATOR ACTIONS FCR A VALID ALARM: ! o INVESTICATE CAUSE OF HICH RADIATION. OR i LO4 MONITOR READINC. ' o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER TO OP-505, RADIATION MONITORING SYSTEM. o i < 1 DISCUSSION: I RV-A2 MONITOR 5 THE AUXILIARY BUILDINC PURCE EXHAUST DUCT. THREE DIFFERE DETECTORS ARE USED, PARTICULATE, IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN CIVE THIS ALARM, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW. ' THE REDA5 SYSTEM MAY ALSO BE. USED TO OBSERVE TREND INFORMATION. ff

REFERENCES:

DRAWINC 208-049-RM-I6 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page'58 l

= i 4 j)"Y):. (Page 57 of 190) ENCLOSURE 1 '( PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 t -= = - ATMOSPHERIC MONITOR WARNING u. EVENT POINT 1717 L INDICATED CONDITION: RM-A2 RADIATION MONITOR PUMP FLOW ABOVE NORMAL QB LESS THAN 5 SCFM. o \\ c REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-A2 FLOW INDICAT70N AT. RADIATION MONITORING PANEL. o jOPERATORACTIONSFORAVALIDALARM: o 'INVESTICATE CAUSE OF RADIATION PUMP FLOW PROBLEM. REFER TO OP-505, RADIATION MONITORING SYSTEM. o iDISCUSSION:

i. RM-A2 MONITOR 5 THE AUXILIARY BUILDING PURCE EXHAUST DUCT; THREE DIFFERENT DETECTORS ARE USED, PARTICULATE, IODINE AND CAS. EITHER A HICH OR LOW FLOW

-CAN CIVE THIS ALARM. / ^-

REFERENCES:

DRAWINC 208-049-RM-02 s L \\'- SENSINC ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 59

.e. ENCLOSURE 1 (Page 58 of 190) PSA-Z ANNUNCIATOR RESPONSE-PSA-2-02-02 H-02-02 l 1 ATMOSPHEP.;C MONITOR WARh. LNG i EVENT PO!NT 1719 i INDICATED CONDITION: RM-A3 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o o RM-A3 RADIATION MONITOR FAILED LOW T (,/ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-A3 INDICATION AT RADIATION MONITORING PANEL. o l OPERATOR ACTIONS FOR A VALID ALARM: I INVESTIGATE CAUSE OF HIGH RADIATION, OR o LOW MONITOR READING. OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o o' REFER TO OP-'505, RADIATION MONITORING SYSTEM. ! DISCUSSION: P RM-A3 MONITORS AUXILIARY BUILDING EXHAUST FROM SAMPLE AREA 'D', THE WASTE CAS COMPRESSOR ROOM, THE WA5TE CA5 VALVE ALLEY, AND ADJOINING AREAS. THIS DETECTOR ONLY HAS A CAS CHANNEL AND EITHER WARNING SETPOINT EXCEEDED OR A ~ DETECTOR FAIRED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. s'

REFERENCES:

DRAWING'208-049-RM-I6 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403-Rev. 32 Page 60

r S ' ENCLOSURE 1 1 (Page 59 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1720 INDICATED CONDITION: o. RM-A3 RADIATION MONITOR PUMP FLOW ABOVE NORMAL DE LESS THAN 5 SCFM. N REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o RM-A3 FLOW INDICATION AT RADIATION MONITORING PANEL. OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE CAUSE OF RADIATION PUMP FLOW PROBLEM. I o REFER TO OP-505, RADIATION MONITORING SYSTEM. .j o ) I DISCUSSION: l-RM-A3 MONITORS AUXILIARY BUILDING EXHAUST FROM SAMPLE AREA 'D', THE WASTE CAS COMPRESSOR ROOM, THE WASTE CAS VALVE ALLEY, AND ADJOINING AREAS. THIS DETECTOR ONLY HAS A CAS CPANNEL AND EITHER A HIGH OR' LOW FLOW CAN GIVE .THIS ALARM. ~ l W

REFERENCES:

DRAWING'-208-049-RM-03 SENSING. ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 61

1 Ly'*%( l I ENCLOSURE 1 g q,,/ (Page 60 of 190) \\. ' PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 l l ATMOSPHERIC MONITOR I WARNING 1 EVENT POINT 1722 l INDICATED CONDITION: I L RM-A4 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o _j, o RM-A4 RADIATION MONITOR FAILED LOW f^ tN REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-A4 INDICATION AT RADIATION MONITORING PANEL. o 7 OPERATOR ACT',0NS FOR A. VALID ALARM: l. i' o INVESTICATE CAUSE 0F HICH RADIATION, OR LOA MONITOR READINC. o DB5ERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER TO OP-505, RADIATION MONITORINC SYSTEM. o i DISCUSSION: ~RM-A4 MONITORS THE SPENT FUEL AREA EXHAUST. THIS DETECTOR ONLY HAS A CAS CHANNEL AND EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LO CIVE THIS ALARM. THE REDAS SYSTEM MAY-ALSO BE USED TO OBSERVE TREND I INFORMATION / 1 /

REFERENCES:

DRAWINC 208-049-RM-17 SENSING ELEMENT: RADIATION MONITORINC PANEL j AR-403' Rev. 32 Page 62

S. /* ENCLOSURE 1 (Page 61 of 190) l-P5A-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 1 ] ATMOSPHERIC MONITOR WARNING { EVENT POINT 1723 INDICATED CONDITION: i RM-A4 RADIATION MONITOR PUMP FLOW ABOVE NORMAL QE LESS THAN 5 SCFM. o i i h-m REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I f4 RM-A4 FLOW-INDICATION AT RADIATION MONITORING PANEL. o i i lOPERATORACTIONSFORAVALIDALARM: o INVESTICATE CAUSE OF RADIATION PUMP FLOW PROBLEM. o ' REFER TO OP-505, RADIATION MONITORING SYSTEM. i l DISCUSSION: I RM-A4 MONITOR 5 THE SPENT FUEL AREA EXHAUST. THIS DETECTOR ON ~ CHANNEL AND.EITHER A HICH OR LOW FLOW CAN CIVE THIS ALARM. L f

REFERENCES:

DRAWINC 208-049-RM-04 SENSING ELEMENT: RADIATION MONITORING PANEL I l ' AR-403 Rev. 32 Page 63 l

] r.- i 73 ENCLOSURE 1 . () (Page 62 of 190) PSA-Z ANNUNCIATOR RESPONSE' PSA-Z-02-02 H 02-02 l l l l~ l ATMOSPHERIC MONITOR WARNING F l-l EVENT POINT 1725 l INDICATED CONDITION: I RM-A5 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR .o o RM-A5 RADIATION MONITOR FAILED LOW l i ..p I REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o RM-A5 INDICATION AT RADIATION MONITORING PANEL. o SPD5 ALPHA PACE, I ' OPERATOR ACTIONS FOR A VALID ALARM: jo INVESTICATE CAUSE OF HICH RADIATION, OR LOA MONITOR READINC. o 0BSERVE ' AREA MONITOR 5/ RECORDERS FOR TREND INFORMATION. o REFER TO OP-505, RADI ATION MONITORING SYSTEM. f IDISCUSSION: RM-A5 MONITORS THE CONTROL COMPLEX RETURN DUCT. THREE DIFFERENT DETECTORS ARE USED, PARTICULATE, IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN CIVE THIS ALARM. EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW. THE REDAS SYSTEM'MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWINC 208-049-RM-18. SENSING ELEMENT: RADIATION MONITORINC PANEL .t AR-403 Rev. 32 Page 64

4 .i .f^g ENCLOSURE 1 (f (Page 63 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 I ATMOSPHERIC MONITOR WARNING I EVENT POINT 1726 INDICATED CONDITION: RM-A5 RADIATION MONITOR PUMP FLOW ABOVE NORMAL QB LESS THAN 5 SCFM. o f) ' \\M'- REDUND*',T INDICATION WHICH WILL VERIFY ALARM. RM-A5 FLOW INDICATION AT RADIATION MONITORING PANEL. o I i OPERATOR ACTIONS FOR A VALID ALARM: o INVESTIGATE CAUSE OF RADIATION PUMP FLOW. PROBLEM. l o REFER TO OP-505. RADIATION MONITORING SYSTEM. = DISCUSSION: l RM-A5 MONITORS THE CONTROL COMPLEX RETURN DUCT. THREE DIFFERENT DETECTOR ' ARE USED, PARTICULATE, IODINE AND CAS. EITHER A HIGH OR LOW FLOW CAN GIVE i THIS ALARM. l /~]

REFERENCES:

DRAWING 208-049-RM-05 l SENSINC ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 65 {

I. l.. ( 7 l f'"'g ENCLOSURE 1 s,) (Page 64 of 190) L PSA-Z ANNUNCIATOR RESPONSE. PSA-Z-02-02 H-02-02 I ATMOSPHERIC h&ONITOR WARNING 1 EVENT POINT 1728 INDICATED CONDITION: RM-A6 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-A6 RADIATION MONITOR FAILED LOW o A 'k_J REDUNDANT INDICATION WHICH WILL VERIFY ALARM: s RM-A6 INDICATION AT RADIATION MONITORING PANEL. o o 5PDS ALPHA PACE. i. OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION, OR o LOW MONITOR READINC. o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o REFER TO OP-505, RADIATION MONITORING SYSTEM. DISCUSSION: RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE.SAMPLE POINTS ARE EITHER AHF-3B DUCT, OR THE RB ATM0$PHERE DIRECTLY. IT IS NORMALLY LINED UP TO THE DUCT OF AHF-3B. IT CAN ALTERNATELY BE LINED UP TO SAMPLE THE RB ATMOSPHERE DIRECTLY PER'0P-417. TWO DIFFERENT DETECTORS ARE USED,' PARTICULATE / BETA AND GAS. ANY ONE OF THESE CHANNELS CAN CIVE THIS ALARM. [' THE REDAs SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. \\~~

REFERENCES:

DRAWINC 208-049-RM-18 SENSING EL5 MENT: ' RADIATION MONITORING PANEL AR-403 Rev. 32 Page 66

l l r j u q r i/^ - D) ' ENCLOSURE 1 (Page 65 of 190) PSA-Z ANNUNCIATOR RESPONSE-PSA-2-02-02 H-02-02 I o a ATMOSPHERIC ) MONITOR WARNING l I EVENT POINT 1729 ( INDICATED CONDITION: RM-A6 RADIATION MONITOR PUMP FLOW ABOVE NORMAL, LESS THAN 5 SCFM, o QB RMA-6 BACKUP SAMPLE PUMP IS RUNNING. (V REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-A6 FLOW INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM:

o. INVESTICATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM. DISCUSSION: EITHER A HICH OR LOW FLOW CAN CIVE THIS ALARM. RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE. SAMPLE POINTS ARE EITHIR it AHF-3B DUCT. OR THE RB ATMOSPHERE DIRECTLY. IT IS NORMALLY LINED UP TO THE DUCT OF AHF-3B. IT CAN ALTERNATELY BE LINED-UP TO SAMPLE THE RB 1 ATMOSPHERE DIRECTLY PER OP-417. 1 TWO DIFFERENT DETECTORS ARE USED, PARTICULATE / BETA AND CAS. ANY ONE OF THESE CHANNELS CAN CIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. '~

REFERENCES:

DRAWINC 208-049-RM,j SENSING ELEMENT: RADIATION MONITORING PANEL -AR-403 4 Rev. 32 Page 67

,( ,,. ') ENCLOSURE 1 (Page 66 of 190) ~ PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 ATlWOSPHERIC MONITOR WARNING EVENT POINT 1731 INDICATED CONDITION: RM-A7 RADIATION LEVEL EXCEED 5 WARNING SETPOINT,'OR' o o RM-A7 RADIATION MONITOR FAILED LOW DD REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o o RM-A7 INDICATION AT RADIATION MONITORING PANEL. l OPERATOR ACTIONS FOR A VALID ALARM: l, i INVESTICATE CAUSE OF HICH RADIATION, OR o LO4' MONITOR READING. OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION. o REFER TO OP-505, RADIATION MONITORING SYSTEM. o l l l DISCUSSION: L j RV-A7 MONITORS THE ' AHF-448.'B DISCHARCE AIR, THEREFORE THE ATMOSPHERES OF I THE PRIMARY SAMPLE ROOM, PIIMARY SAMPLE ROOM SAMPLE HOOD, RADIO CHEMISTRY LAB SAMPLE HOODS, AND/OR PASS SYSTEM VALVE ALLEY MAY HAVE HICH CASEOUS ACTIVITY. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION

REFERENCES:

DRAWINC 208-049-RM-19 rr (,)' SENSINC' ELEMENT: RADIATION MONITORING PANEL i-AR-403 Rev. 32 Page 63 L.

i i ~'N? ENCLOSURE _l x,) (Page 67 of 100) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 ATMOSPHERIC MONITOR VVARNING l EVENT PO NT 1732 INDICATED CONDITION: o RM-A7 RADIATION MONITOR PUMP F )W ABOVE NORMAL QB LESS THAN 5 SCFM. ) '/ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-A7 FLOW INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM: lo INVESTICATE CAUSE OF RADI ATION PUMP FLOW PROBLEM. REFER TO OP-505, RADIATION MONITORING SYSTEM. o I i ' DISCUSSION: EITHER A HICH OR LOW FLOW CAN CIVE THIS ALARM. RM-A7 MONITOR 5 THE AHF-44A/B DISCHARCE AIR, THEREFORE THE ATMOSPHERES OF THE PRIMARY SAMPLE ROOM, PRIMARY SAMPLE ROOM SAMPLE HOOD, RADIO CHEMISTRY LAB SAMPLE HOODS, AND/OR PASS SYSTEM VALVE ALLEY MAY HAVE HICH CASE 0V5 ACTIVITY. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION. !s

REFERENCES:

DRAWINC 208-049-RM-07 i SENSING ELEMENT: RADIATION MONITORING PANEL A R-4 f,3 Rev. 32 Page 69

s-ENCLOSURE 1 L. ) (Page 68 of 190) W. PSA-Z ANNUNCIATOR RESPONSE-PSA-Z-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING ) EVENT POINT 1734 INDICATED CONDITION: RM-A8 RADIATION LEVEL EXCEED 5 WARNING SETPOINT, OR o RM-AS RADIATION MONITOR FAILED LOW. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o - RM-A8 INDICATION AT RADIATION MONITORING PANEL, i i i ! OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HIGH RADIATION, OR

o LOW MONITOR READINC.

o OBSERVE ' AREA MONITORS / RECORDERS FOR TREND INFORMATION. REFER TO OP-505, RADIATION MONITORING SYSTEM. o e fDISCUSSION: i RM-AB MONITORS THE AUXILIARY BUILDINC EXHAUST UPSTREAM OF THE PENETRATIO FOR THE FUEL HANDLING FLOOR EXHAUST. THIS DETECTOR ONLY HAS A CAS CHANN AND, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDA5 SYSTEM MAY ALSO br. USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWINC 208-049-RM-16 SENSI ELEMENT: RADIATION MONITORING PANEL l AR-403 Rev. 32 Page 70 L.

) 6 1 rw ENCLOSURE 1 (Page 69 of 190) l PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 I ATMOSPHERIC MONITOR WARNING + I l i EVENT POINT 1735 INDICATED CONDITION: o RM-A8 RADIATION MONITOR PUMP FLOW ABOVE NORMAL QB LESS THAN 5 SCFM. ', f's V REDUNDANT INDICATION WHICH WILL VERIFY ALARM: .l o RM-A8 FLOW INDICATION AT. RADIATION MONITORING PANEL. 'l

  • OPERATOR ACTIONS FOR A VALID ALARM:

INVESTICATE CAUSE OF RADIATION PUMP FLOW PROBLEM. o o ' REFER TO OP-505, RADIATION MONITORING SYSTEM. .y

  • DISCUSSION:

1 RM-AB b'ONITORS THE AUXILIARY BUILDING EXHAUST UPSTREAM OF THE PENETRATI FOR THE FUEL HANDLING' FLOOR-EXHAUST. THIS DETECTOR 5'ONLY HAS A CAS CHA AND.EITHERAjHICHORLOWFLOWCANCIVETHISALARM. ]. j

REFERENCES:

ORAWINC 206-049-RM-08 L'L/ y. . SENSING ELEMENT: RADIATION MONITORING PANEL r AR-403 Rev. 32 Page 7I

i: , f~"N ENCLOSURE 1 . f i (Page 70 of 190) ') L PSA-Z ANNUNCIATOR RESPONSE. PSA-2-02-02' H-02-02 1 .l -1 i i j l. i ATMOSPHERIC MONITOR WARNING i EVENT POINT 1737-l INDICATED CONDITION: i o RM-All RADIATION LEVEL EXCEED 5 WARNING SETPOINT, OR

o. RM-All RADIATION MONITOR FAILED LOW

,7 3 REDUNDANT INDICATION WHICH WILL VERIFY' ALARM: i RM-All INDICATION AT RADIATION MONITORING PANEL. ' 'o .s - j OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION, OR .o ' LOW MONITOR READINC i o OBSERVE AREA. MONITORS / RECORDERS FOR TREND INFORMATION. l o-REFER TO OP-505, RADIATION MONITORINC SYSTEM. i DISCUSSION: RM-All MONITORS THE AUXILIARY BUILDING EXHAUST PENETRATION FOR THE WASTE I CAS RELEASE PATH. THIS DETECTOR ONLY HAS A CAS CHANNEL AND, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW CAN CIVE THIS ALARM. THE REDAS l.' 5YSTEM MAY AE50 BE USED TO OBSERVE TREND INFORMATION. ,e

REFERENCES:

DRAWINC 208-049-RM-20 t i SENSINC ELEMENT: RADIATION MONITORING PANEL l-f 'AR-403 Rev. 32 l. Page 72 L

.('"} ENCLOSURE 1 (_,/ (Page 71 of 190) PSA-Z' ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 I ATMOSPHERIC MONITOR WARNING EVENT POINT 1739 INDICATED CONDITION: RM-A12 RADI". TION LEVEL EXCEEDS WARNING SETPOINT, OR o o RM-A12 RADIATION MONITOR FAILED LOW (~~'T. l V l REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM A12 INDICATION AT RADIATION MONITORING PANEL. o o MAIN STEAM LINE RAD MONITORS RMG-25, RMG-26, RMG-27, AND/OR RMG-28 READ HIGHER THAN NORMAL. 1 -lOPERATORACTIONSFORAVALIDALARM: INVESTICATE CAUSE OF RADIATION MONITOR PROBLEM. o REFER TO OP-505, RADIATION MONITORING SYSTEM. i o j o CHECK ARV-26/27 FOR PROPER POSITION (ARP-1A/18 3-WAY VALVES) REFER TO CP-I52. PRIMARY TO SECONDARY LEAKAGE OPERATING CUIDELINE ) i c: DISCUSSION: RM-A12 MONITOR 5 THE AUXILIARY BUILDING EXHAUST PENETRATION FOR SECON PLANT CONDENSER OFF GAS. THIS DETECTOR ONLY HAS A CA5 CHANNEL AND, EITHER WARNING' 5ETPOINT EXCEEDED OR DETECTOR FAILED LOW CAN GIVE THIS ALARM. - CHECK FOR SUPPORTING INDICATIONS OF OTSG TUBE LEAKAGE. i RE FERENCL'. DRAWINC 208-049-RM-20 /'~'i ! SENSINC ELEMENT: RADIATION MONITORING PANEL . G). L 'AR-403 Rev. 32 Page 73

.fs. ENCLOSURE 1 .(,). (Page 72 of 190)- ~PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-04 H-02-04 EDAS SYSTEh4 - TROUBLE EVENT POINT 2045 INDICATED CONDITION: o LOSS'0F MULTIPLEXER POWER. . o. PRIMARY-METEOROLOGICAL TOWER ON BACKUP POWER. [) o PRIMARY METEOROLOGICAL TOWER BACKUP POWER OUT OF SYNCHRONIZATION. 1 PRIMARY METEOROLOGICAL TOWER SIGNAL FAILURE. o LJ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: ,o PRIMARY METEOROLOGICAL ALARM PANEL. OPERATOR. ACTIONS FOR A VALID AL' ARM: INVESTICATE CAUSE OF ALARM CONDITION. o -i DISCUSSION: ( ! :\\ j.

REFERENCES:

DRAWINC 208-070-MM-01 SENSING ELEMENT: MMP-3 METEOROLOGICAL ALARM PANEL -AR-403 -Rev. 32 Page 74 ]l

I- .,r'} ENCLOSURE 1 - (j l (Page 73 of 190) PSA-Z ANNUNCIATOR RESPONSE-PSA-Z.-02-05 -H-02-05 ' 1 COND PUMP PIT 1 SUMP LEVEL 1 HIGH EVENT POINT 1329 INDICATED CONDITION: 1 CONDENSATE PUMP PIT SUMP A LEVEL'>88.6' ELEVATION AS SENSED BY SD-31-LS. o '( REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 1 f lOPERATORACTIONSFORA'VALIDALARM: i + .o REFER TO AP-1050. NOTIFY SECONDARY PLANT. OPERATOR-TO INVESTICATE CAUSE OF ALARM CONDITION. o i DISCUSSION: ~ REFERENCE 5;.DRAWINC 208-072-50-07' SENSING ELEMENT: SD-31-LS g$_): 'AR-403 R e v~. 32 Page 75

~

t
i L
e ENCLOSURE 1

{ (Pape'74 of 190) 'PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-05 H-02-05 .i .i y .t'. COND PUMP PIT SUMP LEVEL-HIGH - I EVENT POINT 1317 -INDICATED. CONDITION: c CONDENSATE' PUMP PIT SUMP B LEVEL >88.6' ELEVATION AS SENSED BY SD-32-L5', 'l) ,- V REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 1 f lOPERATORACTIONSFORAVALIDALARM: i o REFER.TO AP-1050. o NOTIFY 5ECONDARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM. CON i f' LDISCUSSION: r i ~

REFERENCES:

DRAWING _20S-072-50-08 SENSING ELEMENT: 5D-32-L5 O l r AR-403. Rev. 32 Page 76

['} ENCLOSURE 1 Td. (Page 75 of 190) 'PSA-Z. ANNUNCIATOR RESPONSE PSA-Z-02-06 H-02-06 1 i AUX BLDG SUMP LEVEL HIGH i EVENT POINT 1292 INDICATED CONDITION: ) DECAY HEAT PIT SUMP A LEVEL >74' ELEVATION AS SENSED BY WD-133-LS. o J v l REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: o. NOTIFY PRIMARY PLANT OPERATOR TO INVESTIGATE CAUSE 0F ALARM CONDITION. i !. DISCUSSION: I, {-<

REFERENCES:

DRAWINC' 208-060-WD-09 ) SENSINC ELEMENT: WD-133-L5 -l } AR-403 Rev. 32 Page 77 I

l l'V-1 . g. A ENCLOSURE 1 (Page 76 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-06 -H-02-06 \\- AUX BLDG SUMP LEVEL ~ HIGH i. l'. EVENT POINT 1305 j' INDICATED CONDITION: l DECAY HEAT PIT SUMP B LEVEL >74' ELEVATION AS SENSED BY WD-134-LS. o .g , '%Y l REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I -i OPERATOR ACTIONS FOR A VALID ALARM: o NOTIFY PRIMARY PLANT OPERATOR TO INVESTIGATE CAUSE OF ALARM CONDITION. DISCUSSION:

REFERENCES:

DRAWING 208 - 060-WD-10'. SENSING ELEMENT: WD-134-L5 1 I AR-403 Rev. 32 Page 78 i

., ~. ] ENCLOSURE 1 t \\ (Page 77 of 190) PSA-Z ANNUNCIATOR' RESPONSE PSA-Z-02-06 H-02-06 AUX BLDG SUMP LEVEL HIGH I EVENT POINT 1300 INDICATED CONDITION: o AUXILIARY BUILDING _ SUMP LEVEL >92.5' ELEVATION A5 SENSED BY WD-132-LS. ,m N REDUNDANT INDICATION WHICH WILL VERIFY ALARM: c' OPERATOR ACTIONS FOR A VALID ALARM: NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION. o DISCUSSION: 6

REFERENCES:

DRAWINC 208-060-WD-12 SENSING ELEMENT: WD-132-L5 - kJ AR-4 0 3_- < Rev. 32 Page 79 i )

c e ('\\ ENCLOSURE 1 'y /- (Page 78 of 190)- PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-06 H-02-06 AUX BLDG f SUMP LEVEL HIGH l EVENT POINT-1809 l INDICATED CONDITION: NUCLEAR SERVICE COOLER AREA SUMP >93'1" ELEVATION AS SENSED BY SD-5-LS. o O REDUNDANT INDICATION WHICH WILL VERIFY ALARM: r . OPERATOR ACTIONS FOR A VALID ALARM: c l NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION. o ( p DISCUSSION: -lo THIS LEVEL. SWITCH IS A MECHANICAL ALTERNATOR WHICH OPERATES BO AND 2B. i SWITCH #1 STARTS THE LEAD PUMP AT 93*0" AND SWITCH #2 STARTS THE LAC PUMP AT 93'I" AND INITIATES THE HICH LEVEL ALARM. I

REFERENCES:

DRAWINC 208-072-50-03 f' SENSING ELEMENT: SD-5-L5 '.s .AR-403 Rev. 32 Page 80

(g f ENCLOSURE 1 ) (Page 79 of 190) i PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-06 H-02-06 t l l AUX BLDG SUMP LEVEL HIGH EVENT POINT 1810 INDICATED CONDITION: o TENDON ACCESS CALLERY SUMP >71'1" ELEVATION AS SENSED BY SD-6-LS. [

f)

,v I REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: o NDTIF) PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION. i DISCUSSION: o THIS LEVEL SWITCH IS A MECHANICAL ALTERNATOR WHICH OPERATES BOTH SDP-3A AND 38. SWITCH *1 STARTS THE LEAD PUMP AT 71'0" AND SWITCH #2 STARTS THE LAC PUMP AT 71'1" AND INITIATES THE HICH LEVEL ALARM.

REFERENCES:

ORAWINC 208-D72-50-05 CT SENSING ELEMENT: SD-6-L5 NJ

AR-403 R e v..

32 Page 81

l -, l ' ' ENCLOSURE 1 (Page 80 of 190). 'PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-07 H-02-07 BLDG SUMPS SUMP PUMP TROUBLE EVENT POINT 1198 i INDICATED CONDITION: DIESEL CENERATOR SUMP A/B !EVEL HICH AS SENSED BY EG-027-L5. o \\ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I i- _ !.0PERATOR ACTIONS FOR A VALID ALARM: i NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION. o . l.- ] i iDISCUSSION:

REFERENCES:

DRAWINC 208-027-EC-17 l i -4 SENSING ELEMENT: EG-027-LS. ' v l AR-403 Rev. 32 Page 82 i I

r' ENCLOSURE 1 (Page 81 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-07 H-02-07 BLDG SUMPS SUMP PUMP TROUBLE EVENT POINT 1586 INDICATED CONDITION:

o. DECAY HEAT PIT SUMP PUMP AUTO START.

o DECAY HEAT PIT SUMP PUMP TRIP. [)s REDUNDANT INDICATION WHICH WILL VERIFY ALARM: j i I PERATOR ACTIONS FOR A VALID ALARM: O i NOTIFY PRIMARY PLANT OPERATOR TO INVESTIGATE CAUSE OF ALARM CONDITION. o 1 I DISCUSSION: s THIS ALARM MAY INDICATE AN AUTO SHUT DOWN IF'THE PRIMARY PLANT OPERATOR ~ MANUALLY STARTED THE DECAY HEAT PIT SUMP PUMP. THE ALARM IS BASED ON' THE PUvP CONTROL SWITCH CONTACTS (NORMA'. AFTER START OR NORMAL AFTER ST IN SERIES WITH THE SUMP LEVEL SWITCH.

REFERENCES:

DRA4INC 208-060-WD-09, WD-10, WD-134 SENSINC ELEMENT: WD-133-LS, WD-134-LS. WDP-3A/3B CONTROL SWITCH CONTACTS. AR-403' Rev. 32. Page 83

f^ - (, ' ENCLOSURE 1 (Page 82 of 190)- PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-07 H-02-07 i { BLDG SUMPS SUMP PUMP 3 TROUBLE I1 l EVENT POINT 1587 INDICATED CONDITION: i AUXILIARY BUILDING SUMP PUMP AUTO START. o AUXILIARY' BUILDING SUMP PUMP TRIP. o g o WASTE CAS COMPRESSOR SEAL LEAKAGE DRAIN TANK LOW LEVEL. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTION 5'FOR A VALID ALARM: DURING NORMAL OPERATING CONDITIONS, THIS IS AN EXPECTED ALARM WHENEVER o THE AUX. BLDC. SUMP PUMP AUTO START 5; IF ALARM DOES NOT CLEAR WITHIN 3-5 MINUTES. THEN NOTIFY PRIMARY PLANT OPERATOR TO INVESTIGATE.CAUSE OF ALARM CONDITION. o ' ENSURE WDV-1030-SV HAS CLOSED (SEAL TANK DRAIN POT DRAIN VALVE). DISCUSSION: THIS ALARM MAY INDICATE AN AUTO SHUT DOWN IF THE PRIMARY PLANT OPERATOR MANUALLY STARTED THE AUXILIARY BUILDING SUMP PUMP (5). THE ALARM IS BASED ON THE PUMP CONTROL SWITCH CONTACTS (NORMAL AFTER START /STOP) IN SE WITH THE SUMP LEVEL SWITCH. THE WASTE CAS COMPRESSOR SEAL LEAKAGE DRAIN t' TANK CAN CIVE THIS ALARM BY OPERATING WDV-1030-SV TO LOWER THE DRAIN T LEVEL UNTIL T,HE LOW LEVEL SWITCH CONTACT OPENS. (SEE DRAWING WD-175) .[~

REFERENCES:

DRAWINC 208-060-WD-11, WD-12, WD-135, WD-175 SENSING ELEMENT: WD-132-LS, WD-357-L52, WDP-4A/48 CONTROL SWITCH CONTACTS. AR-403 Rev. 32 Page 84

1 1 1 f-~]3 ENCLOSURE 1 (Page 83 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-07 H-02-07 4., BLDG SUMPS SUMP PUMP TROUBLE EVENT POINT 1589 INDICATED CONDITION: LAUNDRY AND SHOWER SUMP PUMP AUTO START. o o LAUNDRY AND SHOWER SUMP PUMP TRIP. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 1 \\ OPERATOR ACTIONS FOR A VALID ALARM: DISCUSSION: 1

REFERENCES:

. SENSING ELEMENT: I-) V t. AR-403 Rev. 32 Page 85

{: 's[ -(]j ENCLOSURE 1 (Page 84 of'190) PSA-Z ANNUNCIATOR RESPONSE ' FSA-Z-02-07 H-02-07 [' BLDG SUMPS . SUMP PUMP TROUBLE l-l i EVENT POINT 1806 INDICATED CONDITION: DIESEL CENERATOR ROOM ' A' SUMP' LEVEL HICH AS SENSED BY SD-19-LS. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: . o NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF HICH LEVEL. i - ' DISCUSSION: i e i. l

REFERENCES:

DRAWINC 208-072-SD-15. f-SENSINC ELEMENT: SD-19-LS .f

-- (,

1. AR-403. Rev. 32 Page 86

\\ .,q ENCLOSURE 1 y (Page 85 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-07 H-02-07 i BLDG SUMPS' - ) SUMP PUMP TROUBLE I l EVENT POINT.1807 _ INDICATED CONDITION: DIESEL _ GENERATOR ROOM 'B' SUMP LEVEL HIGH 'AS SENSED BY SD-20-LS. o 1 ~J REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l. -

4 i i OPERATOR ACTIONS FOR A VALID ALARM: j l o - NOTIFY PRIMARY' PLANT OPERATOR TO INVESTIGATE CAUSE OF HICH LEVEL. . DISCUSSION: i

REFERENCES:

DRAWINC 208-072-SD-16. SENSING ELEMENT: SD-20-LS .%d i AR-403 Rev. 32 Page 87

.j- .( ENCLOSURE I (Page 86 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-07 H-02-07 BLDG SUMPS. SUMP PUMP TROUBLE EVENT POINT 1811 INDICATED CONDITION: INTAKE ELECTRIC VAULT SUMP LEVEL HIGH AS SENSED BY SD-14-LS. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: i .lOPERATORACTIONSFORAVALIDALARM: i o' NOTIFY SECONDARY PLANT OPERATOR TO INVESTICATE CAUSE OF HIGH LEVEL. l DISCUSSION: I 1 1

REFERENCES:

DRAWINC 208-072-SD-09. SENSING ELEMENT: SD-14-LS

AR-403 Rev. 32 Page 88

i. ' ENCLOSURE 1 Q. (Page 87 of 190) PSA-Z ANNUNCIATOR RESPONSE. PSA-Z-02-07 H-02-07 i .I BLDG SUMPS SUMP PUMP TROUBLE I l EVENT POINT 1880 4 i I INDICATED. CONDITION: o TURBINE ROOM SUMP LEVEL HICH AS SENSED BY SD-24-L5 QB o OILY WATER' SEPARATOR TROUBLE. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I I OPERATOR ACTIONS FOR. A VALID ALARM: o ' NOTIFY SECONDARY PLANT OPERATOR TO INVESTICATE CAUSE OF HICH LEVEL AND/OR OILY WATER SEPARATOR PROBLEM i !DI5'USSION: C I

0ILY WATER SEPARATOR TROUBLE MAY BE CAUSED BY ANY OF THE FOLLOWING:

HICH/ LOW VACUUM PRE-FILTER HIGH AP OIL DISCHARGE 1 i ~EMERCENCY STOP WHEN IN AUTO THE ALAR" WINDOW DOES NOT TYPE "0ILY WATER SEPARATOR TROUBLE" BUT IN F i 15 LABELED "TUR8INE BUILDING SUMP LEVEL HICH".

REFERENCES:

DRAWINC 208-072 SD-01. SD-17. O D SENSINC ELEMENT: SD-24-L5, SD-24-DPIS, SD-26-PIS AR-403 Rev. 32 Page 89 I

q ..) ENCLOSURE 1 (Page 88 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-07 H-02-07 BLDG SUMPS SUMP PUMP TROUBLE l-EVENT POINT 1913 INDICATED CONDITION: SEWACE PUMP SUMP LEVEL HICH AS SENSED BY LOCAL CIRCUIT. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: SEP-1A AND/OR SEP-1B RUNNINC. o OPERATOR ACTIONS FOR A VALID ALARM: o NOTIFY TURBINE BUILDING OPERATOR TO ENSURE LEVEL DOE 5 NOT OVERFLOW TURBINE BUILDING FLOOR AND THAT SEP-1A AND OR SEP-1B ARE RUNNING TO' LOWER LEVEL. I DISCUSSION:

REFERENCES:

DRAWINC 208-064 ME-10 SENSING ELEMENT: R.1 AR-403 Rev. 32 Page 90

p .f. ) /. l. lt ! jq ENCLOSURE 1 iQ (Page 89 of 190) L PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-08 H-02-08 L i ( ( SEC SAMPLE SYSTEM i ALARM c EVENT POINT 0798 INDICATED CONDITION: l .o HOTWELL/ CONDENSATE CONDUCTIVITY HICH. 1 f~)/.. ! 't i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: SS-141-CIR, CONDUCTIVITY RECORDER ON HVAC SECTION OF MCB. o o COMPUTER POINTS A-100 TO A-104 OPERATOR ACTIONS FOR A VALID ALARM: i o NOTIFY SECONDARY CHEMISTRY TO INVESTICATE CAUSE OF HICH CONDUCTIVITY. o REFER TO CP-138 DISCUSSION: (- l l l I l REFERENCESi DRAWINC 208-054-55 SENSING ELEMENT--: SS-141-CIR i f N /' w l l L AR-403 Rev. 4.' Page 91 i i;

t 4

('N ENCLOSURE 1

(,) (Page 90 of 190) PSA-Z ANNUNCIATOR RESPONSE-PSA-Z-02-08 H-02-08 t ] SEC SAMPLE SYSTEM ALARM .i I EVENT POINT 0887 INDICATED CONDITION:

o. SECONDARY CYCLE SAMPLE ANALYSIS ALARM.

REDUNDANT. INDICATION WHICH WILL VERIFY ALARM: i ~ i OPERATOR ACTIONS FOR A VALID ALARM: o' NOTIFY SECONDARY CHEMISTRY TO INVESTICATE CAUSE OF SAMPLE ALARM. ' DISCUSSION: .L -THIS ALARM INDICATES AN ALARM HAS NOT BEEN ACKNOWLEDCED IN THE SECONDA ! CHEMISTRN LABORATORY WITHIN AN AD)USTABLE TIMER SETTING. l-

REFERENCES:

DRAWINC 208-054-55-11 SENSING ELEMENT: SSCP-I (SECONDARY CYCLE SAMPLE ANALYZER PANEL) O '-I AR-403-Rev. 32 k? Page 92

l {- ' ENCLOSURE 1 s (Page 91 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-01 H-03-01 l I I I g LIQUID l RADIATION j l HIGH I \\ l I 4 EVENT POINT 1786 INDICATED CONDITION: o RM-L1 RADIATION LEVEL EXCEEDS HIGH SETPOINT. ( l __ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-L1 INDICATION AT RADIATION MONITORING PANEL. o o SPDS ALPHA. PACE l' t OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION. o ~ I REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM. o REFER TO OP-505, RADIATION MONITORING SYSTEM. o .y

r. p J

DISCUSSION: 'f m

REFERENCES:

DRAWING 208-049-RM-32 SENSINC ELEMENT: : RADIATION MONITORING PANEL- .AR-403 Rev. 32 Page 93 e

l' t f] _ ENCLO5URE i \\d. (Page 92 of 1901 PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-01 H-03 01 I -I g LIQUID l RADIATION _l HIGH 1 I t EVENT POINT 1788 INDICATED CONDITION: o. RM-L2 RADIATION LEVEL' EXCEED 5 HICH SETPOINT. ( '~ t i REDUNDANT ' INDICATION WHICH WILL VERIFY ALARM: i RM-L2: INDICATION AT RADIATION MONITORING PANEL. -o o ;$PD5 ALPHA PACE OPERATOR ACTIONS FOR A VALID ALARM: o 'INVESTICATE CAUSE OF HICH RADIATION. , o NOTIFY PRIMARY PLANT OPERATOR TO ENSURE WDV-891 AND WDV-892 CLOSED. l o REFER TO OP-505., RADIATION MONITORING SYSTEM.

o CONTACT CHEMISTRY FOR EVALUATION OF MONITOR PRIOR TO MONITOR FLU 5H.

I .a DISCUSSION: WDV-891 AND WDV-892 ARE PRIMARY LIQUID RELEASE VALVES. .(N _

REFERENCES:

DRAWINC 208-049-RM-31 i( SENSINC ELEMENT: RADIATION MONITORING PANEL i AR-4.03, Rev. 32 Page'94 u~

f ENCLOSURE 1 (Page 93 of 190) PSA-Z ANNUNCIATOR RESPONSE-PSA-Z-03-01 H-03-01 I LIQUID g RADIATION { HIGH I l EVENT POINT 1792 INDICATED CONDITION: RM-L3 R'DIATION LEVEL EXCEEDS HICH SETPOINT.' A o C\\ G REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-L3 INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM:

o. INVESTICATE CAUSE OF HICH RADIATION.

.l o REFER TO AP-520, LOSS OF..RCS COOLANT OR PRESSURE. ~ Lo - REFER TO OP-408,- NUCLEAR SERVICES COOLING SYSTEM TO CONNECT SW SURCE TANK'TO WASTE CAS HDR-o REFER TO OP-505. RADIATION MONITORINC SYSTEM. DISCUSSION: ( O-

REFERENCES:

DRAWINC 208-049-RM-32 i SENSING ELEMENT.: RADIATION MONITORING PANEL i AR-403. Rev. 32 Page 95 f

.(b) ENCLOSURE I (Page 94.of 190) 'PSA-Z ANNUNCIATOR RESPONSE-PSA-Z-03-01 H-03-01 I -l 9 LIQUID g RADIATION j l HIGH I l l I EVENT POINT 1794 INDICATED CONDITION: 1 RM-L5 RADIATION LEVEL EXCEEDS HIGH SETPOINT. o 1 iREDUNDANT INDICATION WHICH WILL VERIFY ALARM: RM-L5 INDICATION AT RADIATION MONITORING PANEL. o , OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HIGH RADIATION. o REFER TO AP-520. LOSS OF RCS COOLANT OR PRESSURE. o REFER TO OP-505, RADIATION MONITORING SYSTEM. o 4 .)'* DISCUSSION: s -

REFERENCES:

DRAWING 208-049-RM-32 d-SENSINC ELEMENT: RADIATION MONITORING PANEL 'AR 403 Rev. 32 Page 96

(q ENCLOSURE __1 g (Page 95_of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-01 H-03-01_ ~ l l l l LIQUID j l RADIATION l l HIGH I I i 1 EVENT POINT 1796 INDICATED CONDITION: RM-L6 RADIATION LEVEL EXCEEDS HICH SETPOINT.- o J REDUNDANT INDICATION WHICH WILL VERIFY ALARM: !o RM-L6 INDICATION AT RADIATION MONITORING PANEL. y. / i

)

OPERATOR ACTIONS FOR A VALID ALARM: i INVESTICATE CAUSE OF HICH RADIATION... j o ] o REFER TO AP_-520. LOSS OE RCS COOLANT OR PRESSURE. REFER _TO OP-505, RADIATION MONITORING SYSTEM. -o DISCUSSION: (

REFERENCES:

ORAWINC 208-049-RM-32 k SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 97

y i-f' N 'y).. ENCLOSURE'1 (Page 96 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-01 H-03-01 i i l l 9 LIQUID g RADIATION g j HIGH l l 1 l EVENT POINT 1798 INDICATED CONDITION: o RM-L7 RADIATION LEVEL EXCEEDS HICH SETPOINT. i- > REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 'o RM-L7 INDICATION AT RADIATION MONITORINC PANEL. o'SPDS ALPHA PACE. L OPERATOR ACTIONS FOR A VALID ALARM: i l.. I'o INVESTIGATE CAUSE'0F HICH RADIATION. ',o NOTIFY PRIMARY PLANT OPERATOR TO ENSURE SDV-90 CLOSED. L

o CONTACT CHEMISTRY FOR EVALUATION OF MONITOR PRIOR TO MONITOR FLUSH.

{ o REFik. TO OP-505, RADIATION MONITORING SYSTEM, i l DISCUSSION: SDV-90 15 THE SECONDARY LIQUID RELEASE VALVE. .f q

REFERENCES:

DRAWINC ~208-049-RM-31 SENSINC ELEMENT: RADIATION MONITORINC PANEL AR-403: Rev. 32 Page 98

x ENCLOSURE 1 (Page 97 of 190) PSA-Z ANNUNCIATOP. RESPONSE PSA-Z-03-02 H-03-02 I ' LIQUID MONITOR WARNING EVENT POINT 1787 INDICATED CONDITION: o RM-L1 RADIATION LEVEL EXCEEDS WARNING SETPOINT. l Nm/ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o RM-L1 INDICATION AT RADIATION MONITORINC PANEL. o SPDS ALPHA PACE i OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATJON. o REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM. o REFER TO OP-505, RADIATION MONITORING SYSTEM. o I l DISCUSSION: l ) I i i ~w

REFERENCES:

DRAWINC 208-049-RM-32 l SENSINC ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 99 t

l l yh ENCLOSURE 1 ty (Page 98 of 190) PSA-Z ' ANNUNCIATOR RESPONSE PSA-Z-03-02 H-03-02 . 1 l LIQUID MONITOR- ' WARNING EVENT POINT 1789 , INDICATED CONDITION: RM-L2 RADIATION LEVEL EXCEEDS WARNING SETPOINT. o f .e I i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: l RV-L2 INDICATION AT RADIATION MONITORING PANEL. c o SPDS ALPHA PACE OPEPATM ' ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION. I c REFER TO OP-505. RADIATION MONITORING SYSTEM. c i DISCUSSION: l I l l p

REFERENCES:

DRAWINC 208-049-RM-31 SENSINC ELEMENT: RADIATION MONITORING PANEL . AR - 4 0,3 Rev. 32 Page 100

lj-+)g. .t ENCLOSURE 1 (Page 99_of 190)- 4 PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-02 0-03-02 l LIQUID MONITOR . WARNING EVENT POINT 179.1 INDICATED CONDITION:

o. RM-L3 RADIATION LEVEL EXCEEDS WARNING SETPOINT.

r REDUNDANT. INDICATION WHICH WILL VERIFY ALARM: RM-L3 INDICATION AT RADIATION MONITORING PANEL. o GPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF HICH RADIATION. o l o REFER TO AP-520., LOSS OF RCS COOLANT OR PRESSURE. o REFER TO OP-505, RADIATION MONITORING SYSTEM. DISCUSSION: f-x

REFERENCES:

DRAWING 208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING PANEL s-AR-403' Rev,.32 Page 101

p-l: I ' ja - 1 . ENCLOSURE'1 1 (Page 100 of 190) l PSA-Z. ANNUNCIATOR RESPONSE PSA-Z-03-02 H-03-02 ' LIQUID MONITOR WARNING EVENT POINT 1795 l l INDICATED CONDITION: RM-L5 RADIATION LEVEL EXCEEDS WARNING SETPOINT. o l' l-i l REDUNDANT INDICATION WHICH WILL VERIFY. ALARM: RM-L5 INDICATION AT RADIATION MONITORING PANEL. o i i OPERATOR ACTIONS FOR A VALID' ALARM: I o INVESTIGATE CAUSE OF HICH RADIATION. REFER TO' AP-520 LOSS OF-RCS COOLANT OR PRESSURE. { o 1 REFER TO OP-505, RADIATION MONITORING SYSTEM. o. I I _! DISCUSSION: j l

REFERENCES:

DRAWINC 208-049-RM-32 i ' SENSING ELEMENT: RADIATION MONITORINC PANEL t AR-403 Rev. 32 Page 102 L

.s 1 -W L ().._ (Page 101 of 190) ENCLOSURE 1 PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-02 H-03-02 i i LIQUID 4 c MONITOR l WARNING I EVENT POINT:1797 1 l INDIC TED CONDITION: RM-L6 RADIATION LEVEL EXCEEDS WARNING SETPOINT. .o

(j REDUNDANT. INDICATION WHICH WILL VERIFY ALARM:

RM-L6 INDICATION AT RADIATION MONITORING PANEL. o OPERATOR ACTIONS FOR A VALID ALARM: oINVESTICATE CAUSE OF HIGH RADIATION. l o' REFER TO AP-520, LOSS OF RCS COOLANT OR PRESSURE. REFER TO OP-505, RADIATION MONITORING SYSTEM. o

j.

DISCUSSION: l [.

REFERENCES:

DRAWINC 208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING. PANEL AR-403 Rev. 32 Page 103

1 (()s. ENCLOSURE _1 '(Page 102 of 190) 'l .PSA-Z ANNUNCIATOP. RESPONSE ~PSA-2-03-02 H-03-02 'l ' LIQUID MONITOR WARNING ' 4 EVENT POINT 1799 INDICATED CONDITION: RM-L7 RADIATION LEVEL EXCEEDS WARNING SETPOINT. o l -i

  • REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

of RM-L7 INDICATION AT RADIATION MONITORING PANEL. .o SPDS. ALPHA PACE. y, 4 ! OPERATOR ACTIONS FOR A VALID ALARM: i

  • .o INVESTICATE CAUSE OF HICH RADIATION.

REFER TO OP-505. RADIATION MONITORING SYSTEM. o DISCUSSION:

REFERENCES:

DRAWINC 208-049-RM-31 SENSINC' ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 32 Page 104

e i ENCLOSURE 1 (Page 103 of 190) PSA b NNUNCIATOR RESPONSE PSA-Z-03-03 H-03-03 RM L2/7 INTERLOCK BYPASSED EVENT POINT 2044 INDICATED CONDITION: o INTERLOCK BETWEEN SDV-90 AND RWP-3A/38 DEFEATED. INTERLOCK BETWEEN WDV-892 AND RWP-1, RWP-2A/28 DEFEATED. o (~) l (_ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o RM-L2/7 BYPASS KEY INSTALLED AT RADIATION MONITORINC PANEL. i i OPERATOR ACTIONS. FOR A VALID ALARM: DISCUS 5 ION: BYPASSINC.THE RM-L2/7 INTERLOCK ALLOWS OPENING OF SDV-90 WITH EITHER RWP-1; RWP-2A OR RWP-28 RUNNING INSTEAD OF RWP-3A OR RWP-3B. ALSO WDV-892 MAY BE OPENED WITH RWP-3A OR RWP.38 RUNNING INSTEAD OF RWP-1, RWP-2A OR. RWP-28. f ~s

REFERENCES:

DRAWINC 208-060-WD-60 N-SENSING ELEMENT: RADIATION MONITORING PANEL BYPASS INTERLOCK KEY SWITCH AR-403 Rev. 32 Page 105 1

s ' ENCLOSURE 1 (Page 104 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-01 H-04-01 I I MAKEUP TANK LEVEL l l LOW LOW l l 1 I EVENT POINT 0792-INDICATED CONDITION: MAKEUP TANK LEVEL <I8" AS SENSED BY MU14-LYI-4, MU14-LY2-4. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: i o MU-014-LIR1, MUT LEVEL / PRESSURE RECORDER. A'U-14-LII, MUT LEVEL INDICATION (REDUNDANT INSTRUMENT PANEL). t A'U-14-LI2, MUT LEVEL INDICATION (REDUNDANT INSTRUMENT PANEL). o OPERATOR ACTIONS FOR A VALID ALARM: o ENSURE MUV-58. AND MUV-73 OPEN. RESTORE MAKEUP TANA LEVEL TO NORMAL BAND. c DISCUSSION: l

REFERENCES:

DRAWINC 208-041-MU-17,MU-18' u h[SENSINGELEMENT: MUI4-LYI-4 MUI4-LY2-4. AR-403 Rev. 32 Page 106

t (-). ENCLOSURE 1 (Page 105 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-02 H-04-02 l MAKEUP TANK LEVEL HIGH/ LOW EVENT POINT 1064 INDICATED CONDITION: c' MAKEUP TANK LEVEL >100" AS SENSED BY MU-14-LY3, REDUNDANT INDICATION.WHICH WILL VERIFY ALARM: o MU-014-LIR1, MUT LEVEL / PRESSURE RECORDER. o :MU-14-LII, MUT LEVEL INDICATION' (REDUNDANT INSTRUMENT PANEL). o MU-14-LI2, MUT LEVEL INDICATION (REDUNDANT INSTRUMENT PANEL). o COMPUTER POINT X359 OPERATOR ACTIONS FOR A VALID ALARM: RESTORE MAKEUP TANK LEVEL TO NORMAL BAND. o s DISCUSSION: IF_ MUP(5) ARE ALIGNED TO BWST &.RECIRC FLOW TO MUT IS CAUSINC HICH L 'IN MUT, THEN' CONSIDER ALICNINC MVP SUCTION FROM MUT ONLY. g-'g

REFERENCES:

DRAWING-208-041-MU-47. -I 5ENSING ELEMENT: MU-14-LY3. AR-403 Rev. 32 Page 107

e~xp ENCLOSURE' 1 i(,) (Page 106 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-02-- H-04-02 l MAKEUP TANK i LEVEL HIGH/ LOW EVENT POINT 1065 INDICATED CONDITION: o MAKEUP TANK LEVEL <55" AS SENSED BY MU-14-LY3. l' \\f <\\ j REDUNDANT INDICATION WHICH WILL

  • LRIFY ALARM:

o -MU-014-LIR1 MUT LEVEL / PRESSURE RECORDER. MU-14-LII, MUT LEVEL INDICATION (REDUNDANT INSTRUMENT PANEL). o MU-14-LI2, MUT LEVEL. INDICATION (REDUNDANT INSTRUMENT PANEL). o p o COMPUTER POINT X359. i. OPERATOR ACTIONS FOR A VALID ALARM: [ o RESTORE MAKEUP TANK LEVEL TO NORMAL BAND. l l l DISCUSSION: f. I l l

REFERENCES:

DRAWINC 208-041-MU-47. SENSINC ELEMENT: MU-14-LY3. AR-403 Rev. 32 Page 108

L ' / ENCLOSURE 1 ( (Page 107 of 190) PSA-Z ANNUNCIATOR RESPONSE P5A-2-04 H-04-03 MAKEUP FLOW HIGH EVENT POINT 1066 l l INDICATED CONDITION: I o MAKEUP FLOW >160 GPM THROUCH MUV-31 AS SENSED BY MU-24-F5. l:(O ! -G/ ] REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o MU-24-FI I OPERATOR ACTIONS FOR A VALID ALARM: } j. l o DETERMINE CAUSE OF HICH FLOW ALARM. ' o OBSERVE LTOP CONCERNS o REFER TO OP-301 l-l DISCUSSION: i THE HICH FLOW ALARM WAS ESTABLISHED FOR LTOP CONDITIONS TO PROVIDE 1 INDICATION SHOULD MUV-31 FAIL WIDE OPEN. THE INTENT WAS TO PROVIDE AT i LEAST 10 MINUTES FOR OPERATOR CORRECTIVE ACTION FOR 'THIS TRANSIENT. I _( REFERENCES =: ORAWINC 208-041-MU-47. i i SENSINC ELEMENT: MU-24-FS. i AR-403-Rev. 32 Page 109 j po i

r~3 ENCLOSURE 1

V

..(Page 108 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-04 H-04-04 LETDOWN TEMP HIGH EVENT POINT 1027 INDICATED CONDITION: LETDOWN TEMPERATURE TO PRE-FILTERS >130*F A5 SENSED BY MU-5-TS. o ,O { REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o MU-5-TI OPERATOR ACTIONS FOR A VALID ALARM: REDUCE LE1DOWN FLOW WITH MUV-51 FLOW CONTROL VALVE. i o NOTIFY PRIMARY PLANT OPERATOR TO VERIFY SW THROTTLE VALVES TO LETDOWN o COOLERS '5EALED' ! DISCUSSION: IF LETDOWN HAS ISOLATED VIA MUV-49 REFER TO OP-402 FOR LETDOWN RECOVERY., IF HICH LETDOWN FLOW IS DESIRED THEN CONSIDER STARTING SWP-1A OR SWP PROVIDE ADDITIONAL C00LINC WATER TO THE LETDOWN COOLERS.

REFERENCES:

DRAWINC 208-041-MU-33. U SENSINC ELEMENT: MU-5-TS. AR-403 Rev. 32 Page 110

p ENCLOSURE 1 7g (Page 109 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-05 .H-04. RC PUMP-SEAL BLEED OFF HIGH EVENT POINT 1075 INDICATED CONDITION: o RC PUMP 1A CONTROL BLEED 0FF >1.75 GPM AS CALCULATED BY PLANT COMPUTER. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o COMPUTER. POINT X-922. OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO OP-302 'RC PUMP OPERATION'. DISCUSSION: REFER TO T5 FOR ADMINISTRATIVE REQUIREMENTS. COMPUTER CROUP 78 CONTAIN5' ADDITIONAL DATA FOR RCP-1A. p

REFERENCES:

DRAWINC 208-047 RC-05. 5ENSING ELEMENT: RX00/RC-19A-PT1 AR-403-Rev. 32 Page 111 3

i k. A - ENCLOSURE 1 ), (Page 110 of 190) PSA-Z ANNUNCIATOR' RESPONSE PSA-2-04-05 H-04-05 RC PUMP ~ SEAL BLEED OFF HIGH EVENT POINT 1076 INDICATED CONDITION: RC PUMP 1B CONTROL BLEED 0FF >1.75 GPM AS CALCULATED-BY PLANT COMPUTER. o (L.- REDUNDANT INDICATION WHICH WILL VERIFY ALARM: c. COMPUTER POINT.X-923. OPERATOR. ACTIONS FOR A VALID ALARM: REFER TO OP-302RC PUMP OPERATION'. o DI SCU5510',: REFER TO T5 FOR ADMI'NISTRATIVE REQUIREMENTS. C0vPUTER CROUP 79 CONTAINS ADDITIONAL DATA FOR RCP-18. T t t ! REFERENCE 5; ORAWINC 208-047 RC 06. V jSENSINCELEVEt.T: RX01/RC-19A-PT2 AR-403 Rev. 32 Page 112

p l. l., S' ENCLOSURE 1 (Page 111 of 190) PSA-Z ANNUNCIATOR RESPONSE .PSA-Z-04-05 H-04-05 f .1 i.- l i RC PUMP SEAL BLEED OFF HIGH l EVENT POINT 1077. ' INDICATED CONDITION: l o RC PUMP IC CONTROL BLEED 0FF >1.75 GPM. AS CALCULATED BY PLANT COMPUTER. -] ) REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 1 o COMPUTER POINT X-924. i a OPERATOR ACTIONS FOR A VALID ALARM: i o ~ REFER TO OP-302 'RC PUMP OPERATION'. i 4 DISCUSSION. i !i REFER TO-TS FOR ADMINISTRATIVE REQUIREMENTS ~. COMPUTER CROUP 80 CONTAINS ADDITIONAL DATA FOR RCP-1C. 1 I p

REFERENCES:

DRAWINC 208-047 RC-07. SENSING ELEMENT: RX02/RC-198-PT1. j l nAR-403 Rev. 32 g 4 Page 113-L _..

1 r- - f N. ENCLOSURE 1 ' (j (Page 112 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-05 H-04-05 RC PUMP SEAL BLEED OFF HIGH j EVENT POINT 1078 INDICATED CONDITION: o RC PUMP 1D CONTROL-BLEED 0FF >1.75 GPM AS CALCULATED BY PLANT COMPUTER " - 74 i ]REDUNDANTINDICATIONWHICHWILLVERIFYALARM: o COV.PUTER POINT X-925. 1 .0PERATOR ACTIONS FOR A VALID ALARM: o REFER TO OP-302 'RC PUMP OPERATION'. I s DISCUSSION.: REFER TO T5 FOR ADMINISTRATIVE REQUIREMENTS. .C0VPUTER GROUP 81 CONTAINS ADDITIONAL DATA FOR RCP-1D. l i m-

IREFERENCES:

DRAWINC 208-047 RC-08. ]$Eh,51NCELEMENT: RX-08/RC-19B-PT1. AR-403 Rev. 32 Page 114

1 - /%. ENCLOSURE 1 .Iyf (Page 113.of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-06 H-04-06 i 4 MAKEUP TANK PRESS HIGH/ LOW EVENT POINT 1062 INDICATED CONDITION:

o. MAKEUP TANK PRESSURE 1 THE OVERPRESSURE VALUE CALCULATED BY THE PLANT COMPUTER.

I t"; Q). i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: i MU-014-LIR1, MUT LEVEL / PRESSURE RECORDER. o of COMPUTER POINTS X359 AND X401. OPERATOR ACTIONS FOR A VALID ALARM: o ENSURE MUV-141, MUV-143 CLOSED IMMEDIATELY REDUCE PRESSURE WITHIN THE LIMITS OF MAKEUP TANK o i PRESSURE / LEVEL OF CURVE 8 0F OP-1038. DISCUSSION: THE VALUES 0F THE COMPUTER POINTS ARE INPUT TO A CALCULATION WHICH ' ACTUATES.THIS EVENT POINT WHEN MUT LEVEL / PRESSURE COMBINATION ARE BEIN j - OPERATED IN THE RESTRICTED REGION OF CURVE 8 OP-103B. c,r

REFERENCES:

DRAWINC 208-041-MU-47. \\'N SENSING ELEMENT: CX82 i 'AR-403 Rev. 32. Page 115' 4

i

'l / ff-~)- ENCLOSURE 1 ( j (Page 114 of 190) f 'PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-06 H-04-06 MAKEUP TANK PRESS HIGHILOW EVENT POINT 1063 INDICATED CONDITION: o MAKEUP TANK PRE 550RE. <3 PSIG AS SENSED BY MU-17-PS. ,.!m ' REDUNDANT INDICATION WHICH WILL VERIFY ALARM: MU-014-LIRI. MUT LEVEL / PRESSURE RECORDER.

o

> OPERATOR ACTIONS FOR A VALID ALARM: lc ENSURE MUV-134 CLOSED INCREASE PRESSURE WITHIN LIMIT 5 OF MAKEUP TANK PRES 5URE/ LEVEL CURVE

  • o j

OF OP-103B. jDISCUSSION: I~ vuT PRES 5URE MAY BE TEMPORARILY REDUCED BELOW 3 PSIG DURING VENTING EVOLUTIONS,~BUT SHOULD BE MAINTAINED ABOVE O PSIC.

REFERENCES:

.ORAWINC~208-041-MU-47. I 5ENSINC ELEMENT: MU-17-PS. AR-403 Rev. 32 Page 116 O

1 t [ l lq ENCLOSURE 1

j. g (Page 115 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-07 H-04-07 i L l RC PUMP SEAL RTN (MUV-253) j NOT FULL OPEN l.i I 1 EVENT POINT 1036 .i i INDICATED CONDITION: o MUV-253.NOT FULL OPEN. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o MUV-253 VALVE INDICATION ON PSA.5ECTION AND E.S. LIGHT MATRIX. o COMPUTER POINT P064. i OPERATOR ACTIONS FOR A VALID ALARM: o REOPEN MUV-253. MONITOR RCP SEALS TEMPERATURE / PRESSURE o t l DISCUSSION: l IF MUV-253 CANNOT BE REOPENED THEN REFER TO OP-302. RCP DATA CAN BE OBSERVED ON COMPUTER CR0llPS 78,79,80 AND 81.

REFERENCES:

DRAWINC. 208-041-MU-44. D-SENSING ELEMEN1: RELAY 3MUV-2530. AR.403. Rev. 32' Page 117

l 1 p, ENCLOSURE l' Q 'j (Page 116 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-08 H-04-08 { i i,. b i i t i MAKEUP VALVES AIR i FAILURE EVENT POINT 1094 i i INDICATED' CONDITION: LETDOWN. FLOW CONTROL VALVE MUV-51. LOCKED. o 5 ]REDUNDANTINDICATIONWHICHWILLVERIFYALARM: MUV-51. AIR FAILURE PUSH-BUTTON ILLUMINATED. o / J OPERATOR ACTION 5'FOR A VALID ALARM: c REFER TO AP-470 INVESTICATE LOSS OF INSTRUMENT ~ AIR PRESSURE TO MUV-51. c. 4 CISCUSSION: T40 PRESSURE SWITCHE5 SUPPLY PRESSURE INFORMATION TO THE CONTROL C FOR MUV-51, MU-3-PSI SET FOR 32 PSIC AND MU-3-PS2 SET FOR 28 PSIC. IF EITHER. MU-3-PS1 OR MU-3-PS2 IS ACTUATED, THE VALVE POSITION WILL BE LOCKED "A5 IS" B) THE-ISOLATION OF THE AIR LINE-FROM THE POSITIONER TO THE VALVE , DIAPHRACY. OPERATION OF THE VALVE BY DEPRESSING THE AIR FAILURE RESET i PUSH-BUTTON IS NOT CERTAIN AT THIS LOW AIR PRES 5URE. s-f

REFERENCES:

DRAWINC 208-041-MU-54 4..'

SEN51NC. ELEMENT

MU-3-PSI, MU-3-PS2. I i AR-403 Rev. 32 Page 118 e

s. u f'N ENCLOSURE 1 - Q i-(Page 117 of 190) - PSA-Z: ANNUNCIATOR RESPONSE PSA-2-04-08 H-04-08 MAKEUP VALVES AIR-FAILURE EVENT POINT 1095 INDICATED CONDITION: o MAKEUP CONTROL VALVE MUV-31 LOCKED. O-M REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o NNI-AR3 LIGHT 31 IN NNI CABINET 2 MUV-31 AIR FAILURE PUSH-BUTTON ILLUMINATED. o o MUV-31 CONTROL STATION IN ' HAND'. OPERATOR ACTIONS FOR A VALID ALARM: o--REFER TO AP-470 INVESTICATE LOSS OF INSTRUMENT AIR PRES 5URE TO MUV-31. o DISCUSSION: . MUV-31 WILL LOCK IN POSITION ON AIR / ELECTRICAL FAILURE. r THE VALVE WILL FAIL CLOSED ON LOSS OF AIR TO THE DIAPHRAGM. 4 f-]

REFERENCES:

DRAWING. 208-041-MU-54 SENSING ELEMENT: 'MU-25-P51 -AR-403 Rev. 32 Page 119

'3 ) ENCLOSURE 1 (Page 118 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-08 H-04-08 I MAKEUP VALVES AIR FAILURE l i i EVENT POINT 1096 INDICATED CONDITION: o MAKEUP CONTROL VALVE MUV-16 LOCKED. Y-REDUNDANT INDICATION WHICH WILL VERIFY ALARM: , o NNI-AR4 LICHT 16 IN NNI CABINET 2. Io MUV-16 AIR FAILURE PUSH-BUTTON ILLUMINATED. MUV-16 CONTROL STATION IN ' HAND'. o OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO AP-470 INVESTICATE LOSS OF INSTRUMENT AIR PRES 5URE TO MUV-16. o DISCUSSION: MUV-16 WILL 10CK IN POSITION ON AIR / ELECTRICAL FAILURE. THE VALVE WILL FAIL OPEN ON LOSS OF AIR TO THE DIAPHRACM. l f'"X

REFERENCES:

DRAWINC 208-041-MU-54 t 1 lSENSINCELEMENT: MU-15-P51 AR-403 Rev. 32 Page 120

/^- ENCLOSURE 1 (Page 119 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-08 H-04-08. Y MAKEUP VALVES AIR FAILURE EVENT POINT 1102 INDICATED CONDITION: i RC PUMP SEAL BLEED 0FF VALVE MUV-253, AIR SUPPLY PRESSURE <80 PSIG A5 o '5ENSED BY MU-253-PS. O y REDUNDANT INDICATION WHICH WILL VERIFY ALARM: .i lOPERATORACTIONSFORAVALIDALARM: .o REFER TO AP-470 'o INVESTIGATE. LOSS OF INSTRUMENT AIR PRESSURE TO MUV-253. DISCUSSION: h-OPERATION OF THE VALVE IS NOT CERTAIN AT THIS LOW AIR PRESSURE. MUV-253 FAILS CLOSED IF THE AIR PRES 5URE'I5 INSUFFICIENT! AGAINST.THE CLOSURE SPRING OF THE' VALVE OPERATOR.

REFERENCES:

ORAWINC 208-04I-MU-54 SENSINC ELEMENT: MU-15-PS1, MU-15-PS2 a 'AR-403 Rev. 32 Page 121

./~i}f ENCLOSURE 1 (Page 120 of 190) ) -PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-01 H-05-01 6 i I STM GEN A g MAIN STEAM ISO 3 g ACTUATED l l EVENT POINT 2007 -r ) I. INCICATED CONDITION: EFIC CHANNEL "A", STEAM CENERATOR "A" MAIN STEAM LINE ISOLATION BUS 1 OR o BUS 2 TRIPPED. 1 REDUNDANT INDICATION WHICH WILL VERIFY ALARM: ! o ' HALF OR FULL TRIP ON EFIC CHANNEL "A" MAIN STEAM LINE ISOLATION. lo MS-106-PI, CHANNEL "A", OTSC A PRESSURE INDICATION. .o MS-106-PIR. CHANNEL "A'l, OTSC A/B PRESSURE RECORDER. OPERATOR ACTIONS FOR A VALID ALARM: REFER TO ECP-05, EXCESSIVE HEAT TRANSFER. i o .o. INVESTICATE CAUSE OF TRIP CONDITION. 2 ! DISCUSSION.; i' v5LI~ ACTUATION SETPOINT IS OTSC PRESSURE <600 PSIC. WITH THIS EVENT POINT 8 IN' ALARM, A HALF TRIP OR FULL. TRIP CONDITION EXISTS THE OPERATOR MUST f. OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ~ ACTU NO ADDITIONAL. ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS. %s)

REFERENCES:

. VITRO DRAWING 3801-3005 SHEET l' l SENSING ELEMENT: 'AR-403-Rev. 32 Page 122

.9 e i i

{ '

ENCLOSURE 1 Q (Page 121 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-01 H-05-01 )

Y' I

I i l l-STM GEN A l l MAIN STEAM ISO ) l-l ACTUATED l l l l EVENT POINT 2015 i INDICATED CONDITION: EFIC CHANNEL "B", STEAM CENERATOR "A" MAIN STEAM LINE ISOLATION BUS 1 OR o BUS 2 TRIPPED. i i /~j! -). i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o HALF OR FULL TRIP ON EFIC CHANNEL "B" MAIN STEAM LINE ISOLATION. ~ 1 o - MS-107-PI, CHANNEL "B", OTSC A PRESSURE INDICATION. o ' MS-107-PIR, CHANNEL "B", OTSC A/B PRESSURE RECORDER. OPERATOR l ACTIONS FOR A VALID ALARM: i 4 o. REFER TO E0P-05. EXCESSIVE HEAT TRANSFER. o.INVESTICATE CAUSE OF TRIP CONDITION. DISCUSSION: MSLI ACTUATION SETPOINT IS OTSC PRESSURE <600 PSIG. WITH THIS EVENT POIN IN ALARM, A HALF. TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO. DETERMINE EFIC ACTUATION STATUS. NO ADDITIONAL ALARMS DIFFERENTIATE ~BETWEEN FULL AND HALF TRIPS. 'i i

REFERENCES:

VITRO URAWING 3801-3005 SHEET 2 SENSING ELEMENT: i I AR-403 Rev. 32 Page 123

r. I ' ' '~%i k- / ENCLOSURE 1 {[g,j (Page 122 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-02 H-05-02 s L t STM GEN A FEEDVVATER ISO-ACTUATED EVENT POINT 2009 INDICATED CONDITION: EFIC CHANNEL "A", STEAM CENERATOR "A" MAIN FEEDWATER ISOLATION BUS 1 OR -o BUS 2 TRIPPED. .s REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I o HALF OR FULt. TRIP ON EFIC CHANNEL' "A" MAIN FEEDWATER ISOLATION. v5-106-PI. CHANNEL "A", OTSC A PRESSURE INDICATION. o v5-106-PIR, CHANNEL "A", OTSG A/B PRESSURE RECORDER. o OPERATOR ACTIONS FOR A VALID ALARM

  • 9EFER TO E0P-05 EXCESSIVE HEAT TRANSFER.

o INVESTICATE CAUSE OF TRIP CONDITION, o DISCUSSION: urWI ACTUATION SETPOINT IS' OTSC PRESSURE <600 PSIC. WITH THIS EVENT POINT IN ALARY. A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST L . OBSERVE THE EFIC PUSH-BUTTONS TO. DETERMINE EFIC ACTUATION STATUS. NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS. ,('"N '(,)

REFERENCES:

\\ITRO DRAWING 3801-3005 SHEET I lSENSINCELEMENT: l .n AR-403 Rev.1 32 Page 124 o i

l' I-l l _ (/3 l l N-)- ENCLOSURE 1 a (Page 123 of 190) I PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-02 H-05-02 STM GEN A FEEDWATER ISO } ACTUATED l i EVENT POINT 2017 i = INDICATED CONDITI)N: EFIC CHANNEL "B", STEAM CENERATOR 'A' MAIN FEEDWATER ISOLATION BUS 1 OR o BUS 2 TRIPPED. ^() .v p REDUNDANT. INDICATION WHICH WILL VERIFY ALARM: G o HALF OR FULL TRIP ON EFIC CHANNEL "B" MAIN FEEDWATER ~ ISOLATION. l. o'MS-107-PI, CHANNEL "B", 0TSC A PRESSURE INDICATION. MS-107-PIR CHANNEL "B". OTSC A/BJPRESSURE RECORDER. o ll L OPERATOR ACTIONS FOR A-VALID ALARM: i o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER. o INVESTICATE. CAUSE OF TRIP CONDITION. l DISCUSSION: MFWI ACTUATION SETPOINT IS OTSC PRESSURE <600 PSIG. ' WITH THIS EVENT POINT IN-ALARM, A. HALF-TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE $FIC PUSH-BUTTONS TO'. DETERMINE EFIC ACTUATION STATUS. ~ NO ADDITIONAL, ALARMS; DIFFERENTIATE BETWEEN FULL AND -HALF TRIPS. <s g [ (,)

REFERENCES:

{.. TVITRO DRAWINC '3801-3005 SHEET 2 SENSING ELEMENT: i , AR-403 .Rev 32 f 'Page 125 g

q' ENCLOSURE 1 g. (Page 124 of 190L n PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-03 H-05-03 MAIN STEAM ISO VALVE AIR FAILURE EVENT POINT 0956 l INDICATED CONDITION: o MSV-413 AND M5V-414 AIR SUPPLY PRESSURE <80 PSIG A5 SENSED BY MS-99-PS. .q (_). REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO AP-470 INVESTICATE LOSS OF INSTRUMENT AIR PRESSURE TO MSIVs. o DISCUSSION: .ON A LOSS OF INSTRUMENT AIR, THE ACCUMULATORS SHOULD MAINTAIN THE MSIVs ' OPEN FOR AT LEAST I HOUR DEPENDENT ON ACTUATOR LEAKAGE. DECRADATION OF THE ACCUMULATOR PRESSURE WILL BE INDICATED BY THE ILLUMINATION OF THE SV-I/5V-2 WHITE TEST LICHT ON THE PSA PANEL. l' j i .,r y }

REFERENCES:

DRAWINC 208-039 MS-I4 ...l SENSING ELEMENT: MS-99-P5 j AR-403 Rev. 32 Page 126

i O ENCLOSURE 1 (Page 125 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-03 H-05-03 MAIN STEAM ISO VALVE A,lR FAILURE i a EVENT POINT 0959 l INLICATED CONDITION: M5V-411 AND MSV-412 AIR SUPPLY PRESSURE <80 PSIG AS SENSED BY MS-98-PS. o i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 1 .. I OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO AP-470 INVESTICATE LOSS OF INSTRUMENT AIR PRESSURE TO MSIVs; o f DISCUSSION: ON A LOSS OF INSTRUMENT AIR, THE ACCUMULATORS SHOULD MAINTAIN THE MSIVs OPEN FOR AT. LEAST. HOUR DEPENDENT ON ACTUATOR LEAKAGE. DEGRADATION OF t THE ACCUMULATOR PRESSURE WILL BE INDICATED BY THE ILLUMINATION OF THE i SV-1/5V-~2 WHITE TEST LIGHT ON THE PSA PANEL. 1

REFERENCES:

DRAWINC 208-039 MS-14 ~ SENSING ELEMENT: MS-98-PS. 'AR-403 Rev. 32 Page 127

4 1. -i. 'f .T -(Q ENCLOSURE 1 (Page 126 of 190) PSA-Z~ ANNUNCIATOR RESPONSE PSA-Z-05-04 H-05-04 LETDOWN. PRESSURE HIGH o, EVENT POINT 1060 INDICATED CONDITION: o - LETDOWN PRESSURE AFTER BLOCK ORIFICE >I45 PSIG AS SENSED BY MU-6-PS. .f~)g 'w . REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I o COMPUTER. POINT X002. ' OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE CAUSE OF HICH PRES 5URE CONDITION. o. i c REDUCE LETDOWN FLOW. 't !1 ' DISCUSSION: A POSSIBLE CAUSE OF HICH PRESSURE AT THIS POINT IN THE SYSTEM IS ISOLATION . ' 0F 004NSTREAM COMPONENTS OR ANY FLOW RESTRICTIONS IN THE PRE-FILTERS, i POST-FILTERS OR MAKEUP DEMINS. IF THE HICH PRESSURE CONDITION EXISTS ANf 4 'ITS CAUSE CANNOT BE DETERMINED THEN CLOSURE OF MUV-49 MAY BE REQUIRED PREVENT POSSIBLE RELIEF VALVE OPERATION TO THE A.B. SUMP. 3 p-

REFERENCES:

DRAWINC 208-04I MS-47 .SENSINC ELEMENT: MS-6-PS 1 'AR-403-Rev.-32 Page 128

] ENCLOSURE 1 (Page 127 of 190) PSA-Z ANNUNCIATOR RESPONSE P5A-2-05-05 H-05-05 s MAKEUP FILTERS A PRESS HIGH EVENT POINT 1061 INDICATED CONDITION: c' MAKEUP POSTFILTEF. i.'IFFERENTIAL PRES 5URE >25 PSIG AS SENSED BY MU-18-D REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o MAKEUP POSTFILTER DIFFERENTIAL PRESSURE MU-18-DPI. OPERATOR ACTIONS FOR A VALID ALARM: PLACE "A" AND "B" POST-FILTERS IN SERVICE. o o REDUCE LETDOWN FLOW. ~l l { DISCUSSION: DO NOT INITIATE FILTER CHANGE OUT UNTIL STEADY STATE DP REACHES 25 o . P5ID, AS INDICATED ON MU-18-DPI ,7

REFERENCES:

ORAWING'208-041 MU-47 SENSING ELEMENT: MU-18-DP5 'AR-403 Rev. 32 Page 129

~ - 1 r~'g . ENCLOSURE 1 f L(,,/ (Page 128 of 190). PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-05 H-05 *. I l f MAKEUP FILTERS A PRESS HIGH EVENT POINT 1082 INDICATED CONDITION: MAKEUP PRE-FILTER DIFFERENTIAL PRES 5URE >12-PSIG AS SENSED BY MU-8I-DPS. o fJ h L REDUNDANT INDICATION WHICH WILL VERIFY ALARM: MAKEUP PRE-FILTER DIFFERENTIAL PRESSURE INDICATION MU-8I-DPI. c OPERATOR ACTIONS FOR A VALID ALARM: PLACE "A" AND "B" PRE-FILTERS IN SERVICE. .c c REDUCE LETDOAN FLOW. r DISCUSSION: c' DO NOT INITI ATE FILTER CHANCE OUT UNTIL STEADY STATE DP REACHES 12 PSID, AS INDICATED ON MU-SI-DPI ('~g

REFERENCES:

DRAWINC 208-04I MU-47 ,SENSINC ELEVENT: MU-8I-DP5 .AR-403 Rev. 32 Page 130

/"'( -j ).

ENCLOSURE 1

{ (Page 129 of 190) 1 PSA-Z ANNUNCIATOR RESPONSE-PSA-Z-05-06 H-05-06 1 ~ l MAKEUP DEMIN . A PRESS ) HIGH EVENT POINT 1083 INDICATED CONDITION: o MAKEUP DEMIN DIFFERENTIAL PRES 5URE >14 PSIG AS SENSED BY MU-75-DPS. f. L) REDUNDANT INDICATION WHICH WILL VERIFY ALARM: MAKEUP DEMIN' DIFFERENTIAL PRES 5URE-INDICATION MU-75-DPI. o OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO OP-402 BYPASS DEMINERALI2ERS OR PLACE ALTERNATE DEMIN IN SERVICE o o REDUCE LETDOWN FLOW DISCUSSION: CONSIDERATION SHOULD BE CIVEN TO THE AFFECT ON THE RCS OF PLACING THE ALTERNATE DEMIN IN SERVICE. IF IT IS NOT SATURATED AT THE SAME LEVEL A5 THE RCS IS'AT THE TIME THE ALTERNATE DEMIN IS PLACED IN SERVICE THERE W BE A SIGNIFICANT CHANGE IN CORE REACTIVITY THAT MAY' CAUSE A SIGNIFICANT OPERATIONAL 'iXCUR510N OR REDUCTION OF THE' SHUTDOWN MARGIN.

('

REFERENCES:

DRAWINC 208-041 MU-47 \\' SENSING ELEMENT: MU-75-DPS 1AR-403-Rev. 32 Page 131

(A) ENCLOSURE-1 (Page 130 of 190) - PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-07 H-05-07' ~ . ) RC PUMP SEAL FLOWS HIGHILOW t EVENT POINT 1079 INDICATED CONDITION: REACTOR C00LANT' PUMP TOTAL SEAL FLOW >42 GPM AS SENSED BY MU-27-F5. o D'( REDUNDANT, INDICATION WHICH WILL VERIFY ALARM: REACTOR COOLANT PUMP TOTAL SEAL. FLOW INDICATION MU-27-FI, ,o i OPERATOR ACTIONS FOR A VALID ALARM: ) i. o REFER TO OP-302. o REESTABLISH NORMAL SEAL FLOW. DISCUSSION: i

IREFERENCES:

DRAWINC 208-041_MU-47 t\\ SENSINC ELEMENT: MU-27-F5 'AR-403' Rev. 32 Page 132

(^ ENCLOSURE 1 -( (Page 131 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-07 H-05-07 RC PUMP SEAL FLOWS HIGH/ LOW i. EVENT POINT 1080 INDICATED CONDITION: o REACTOR COOLANT PUMP TOTAL SEAL FLOW <22 GPM AS SENSED BY MU-27-F5. REDUNDANT-INDICATION WHICH WILL-VERIFY ALARM:

o. REACTOR COOLANT PUMP TOTAL SEAL FLOW INDICATION MU-27-FI.

OPERATOR ACTIONS FOR A VALID ALAP.M: o REFER TO OP-302. o REESTABLISH NORMAL SEAL FLOW. DISCUSSION: I

REFERENCES:

DRAWINC 208-041 MU-47 SENSING ELEMENT: MU-27-FS-AR-403 Rev. 32 Page 133

l 'I!' o-m. ENCLOSURE 1 (Page 132 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-07. H-05-07 1 RC PUMP SEAL FLOWS 2

HIGHILOW I-EVENT POINT 1084 INDICATED CONDITION:

REACTOR COOLANT PUMP 1A SEAL FLOW <3 GPM AS SENSED BY MU-7-F51. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: REACTOR COOLANT PUMP 1A SEAL FLOW INDICATION MU-7-FII. o i OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO OP-302. o REESTABLISH NORMAL SEAL FLOW. t l l lOISCUSSION: I N, - '

REFERENCES:

DRAWINC 208-041 MU-47 j lSEN51NCEtc. MENT: MU-7-F51 i t-l 'AR-403 Rev. 32 l Page 134

/"N ENCLOSURE 1 '(j. (Page 133 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-07 H-05-07 RC' PUMP SEAL FLOWS HIGH/ LOW EVENT POINT 1085 INDICATED CONDITION: o REACTOR COOLANT PUMP 1B SEAL FLOW <3 GPM AS SENSED BY MU-7-FS2. O REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 01 REACTOR COOLANT PUMP IB SEAL FLOW INDICATION MU-7-FI2. OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO OP-302. REESTABLISH NORMAL SEAL FLO4. o DISCUSSION: , (^g '

REFERENCES:

DRAWINC 208-041 MU-47 SENSING ELEMENT: MU-7-F52 i 'AR-403~ Rev. 32 Page 135

4 Q(]- ENCLO5URE 1 (Page 134 of 1901 PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-07 H'05-07' a RC PUMP SEAL FLOWS HIGHILOW - EVENT POINT 1086 INDICATED CONDITION: REACTOR COOLANT PUMP IC SEAL FLOW <3 GPM AS SENSED BY MU-7-F53. o REDUNDANT INDICATION ~WHICH WILL VERIFY ALARM: REACTOR COOLANT PUMP 2C SEAL FLOW INDICATION MU-7-FI3. o OPERATOR ACTIONS FOR A VALID ALARM: c F.EFER TO OP-302. o REESTABLISH NORMAL SEAL FLOW. . DISCUSSIOM - l

REFERENCES:

DRAWINC 208-041 MU-47 ISENSINCELEMENT: MU-7-F53 i AR-403 Rev. 32 Page 136

l l-I 1 /~' ENCLOSURE 1 (Page 135 of 190) ( PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-07 H-05-07 3C PUMP ' SEAL FLOWS HIGH/ LOW 4 EVENT POINT-1087 INDICATED CONDITION: Y o' REACTOR COOLANT PUMP '1D SEAL FLOW- <3 GPM AS SENSED BY MU-7-F54 v REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o. REACTOR COOLANT PUMP 10 SEAL FLOW INDICATION MU-7-FI4 OPERATOR ACTIONS FOR A VALID ALARM: ~ o REFER TO OP-302. o REESTABLISH NORMAL SEAL'~ FLOW. DISCUSSION: pq

REFERENCES:

DRAWING 208-041'MU-47 SENSING ELEMENT: MU-7-F54 ' AR-403 Rev. 32 Page 137

/]

  • Q ENCLOSURE 1 (Page 136 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-08 H-05-08 BWST VLV INTERLOCK BYPASSED EVENT POINT 2048 INDICATED CONDITION: o MAKEUP TANK LOW-LOW LEVEL INTERLOCK DEFEATED FOR MUV-58 AND/OR MUV-73 O'

  • REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

54 ITCH POSITIONS IN "A" AND "B" REMOTE SHUTDOWN AUXILIARY CABINET 5. OPERATOR ACTIONS FOR A VALID ALARM: DISCUSSION: THE Sa' ITCH FOR MUV-73 INTERLOCK IS LOCATED IN THE"A" REMOTE SHUTDOWN AUKILIARY CABINET IN THE "A" ES 4160V SWITCHCEAR ROOM. THE SWITCH FOR , vuv-58 INTERLOCK IS LOCATED IN THE "B" REMOTE SHUTDOWN AUXILIARY CABINET. IN THE "B" ES 4160V SWITCHCEAR ROOM. USE 550D KEY 47 TO ACCESS THE I AVAILIARY CABINETS. i i l

REFERENCES:

DRAWINC 205-041 MU-07 k 'l SENSINC' ELEMENT:ZZ 55/BYP, RS-AUX A/B AR-403 .Rev. 32 Page 138

p ENCLOSURE 1 yf - (Page 137 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-01 H-06-01 I l STM GEN B g g MAIN STEAM ISO l l ACTUATED l l I I I EVENT POINT 2008 INDICATED CONDITION: EFIC CHANNEL "A", STEAM CENERATOR "B" MAIN STEAM '.INE ISOLATION BUS 1 OR o BUS 2 TRIPPED. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: HALF OR FULL TRIP ON EFIC CHANNEL "A" MAIN STEAM LINE ISOLATION. o o M5-110-PI, CHANNEL "A", OTSC B PRESSURE INDICATION. MS-106-PIR. CHANNEL "A", OTSC A/B PRESSURE RECORDER. o OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER. INVESTICATE CAUSE OF TRIP CONDITION. o DISCUSSION: MSLI? ACTUATION SETPOINT IS OTSC PRESSURE A600 PSIC. WITH THIS EVENT POI IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC' PUSH-BUTTONS TO. DETERMINE EFIC ACTUATION STATUS. -NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS. O _ (f

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT: AR-403- _Rev. 32 Page 139

. /'N ENCLOSURE'l (Page 138 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-01 H-06-01 I .l l STM GEN B g g MAIN STEAM ISO l l ACTUATED I I I I EVENT POINT 2016 INDICATED CONDITION: EFIC CHANNEL ~"B". STEAM GENERATOR "B" MAIN STEAM LINE ISOLATION BUS 1 OR -o . BUS 2 TRIPPED. ~ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: . o HALF OR FULL TRIP ON EFIC. CHANNEL "B" MAIN STEAM LINE ISOLATION. i ~ v5-111-PI, CHANNEL "8" OT5C A PRESSURE INDICATION. o o M5-107-PIR, CHANNEL "B", OTSC A/B PRESSURE RECORDER. 6 OPERATOR ACTIONS FOR A VALID ' ALARM: o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER. .o INVESTICATE CAUSE OF TRIP CONDITION. iDISCUSSION: MSLI ACTUATION SETPOINT IS OTSC PRESSURE <600 PSIC. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS. NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS. ew

REFERENCES:

VITRO DRAWING 3801-3005 5HEET 2 l SENSING ELEMENT: I LAR-403 Rev. 32 Page 140 7

r~' (,)g ENCLOSURE 1 (Page 139 of 190)- PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-02 H-06-02 4 STM GEN B FEEDVVACTER ISO ACTUATED EVENT POINT 2010 INDICATED CONDITION: o EFIC CHANNEL "A", STEAM CENERATOR "B" MAIN FEEDWATER ISOLATION BUS 1 OR BUS 2 TRIPPEO. "g {O REDUNDANT INDICATION WHICH WILL VERIFY ALARM: HALF OR FULL TRIP DN EFIC CHANNEL "A" MAIN FEEDWATER ISOLATION. o MS-110-PI, CHANNEL "A", OTSC B PRESSURE INDICATION, o o MS-106-PIR CHANNEL "A", OTSC A/B PRES 5URE RECORDER. OPERATOR ACTIONS FOR A VALID ALARM: i REFER TO E0P-05, EXCESSIVE HEAT TRANSFER. -o INVESTICATE CAUSE OF TRIP CONDITION. o i l DISCUSSION: MFWI ACTUATION SETPOINT IS OTSC PRESSURE <600 PSIC. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST ~ i 0BSERVE THE 8FIC PUSH-BUTTONS-TO DETERMINE EFIC ACTUATION STATUS. NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS. (~s. r(_,)

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 [ - 5ENSINC ELEMENT: j..

AR-403 Rev. 32 Page 141-

7 x,- ENCLO5URE 1 s ) (Page 140 Eof 190), PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-02 H-06-02 ~. STM GEN B FEEDVVATER ISO ACTUATED EVENT POINT 2018 INDICATED CONDITION: ~ o-EFIC CHANNEL "B", STEAM CENERATOR "B" MAIN FEEDWATER ISOLATION BUS 1 OR BUS 2 TRIPPED. . fh (_-) REDUNDANT INDICATION WHICH WILL VERIFY ALARM: HALF OR FULL TRIP ON EFIC CHANNEL "B" MAIN FEEDWATER = ISOLATION. -O o 'v5-111-PI, CHANNEL "B", OTSC B PRESSURE INDICATION. v5a107-PIR., CHANNEL "B", OTSC A/B PRESSURE' RECORDER. c OPERATOR ACTIONS FOR A VALID ALARM: REFER TO E0P-05, EXCESSIVE HEAT TRANSFER. o INVESTICATE CAUSE OF TRIP CONDITION. o DISCUSSION: VFWI ACTUATION SETPOINT IS OTSC PRESSURE <600 PSIC. WITH THIS EVENT POINT IN ALARY. A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS. L ND ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS. l (5 /~ j,

REFERENCES:

VITRO DRAWING 3801-3005' SHEET 2 ~jSENSINGELEMENT: 1 ' AR - 4 0.3 : Rev. 32 ( Page I42

ENCLOSURE _J (Page 141 of 190) J PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-03 H-06-03 EMERG FVV ACTUATION EVENT POINT 2006 INDICATED CONDITION: EFIC CHANNEL "A", EMERGENCY FEEDWATER BUS 1 OR BUS 2 TRIPPED. o bQ-REDUNDANT INDICATION WHICH WILL VERIFY ALARM: HALF'OR FULL TRIP ON EFIC CHANNEL "A" EMERGENCY FEEDWATER ACTUATION. o OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO E0P. o INVESTICATE CAUSE OF TRIP CONDITION. p-DISCUSSION: WITH THI5' EVENT POINT IN ALARM. A HALF TRIP OR FULL' TRIP CONDITION EXISTS. .THE OPERATOR MUST 0BSERVE THE EFIC PUSH-BUTTONS TO. DETERMINE EFIC ACTUATION STATUS. EFIC ACTUATE 5 BY ANY OF THE FOLLOWING CONDITIONS: EITHER OTSC <600 PSIC EITHER OTSC APPROACHING 0" MANUAL ACTUATION LOSS OF ALL'RCPs ~ NI POWER >45% W/FW <17% HPI A AND B ACTUATION LOSS OF BOTH MFPs W/RPS NOT IN 5/D-BYPASS

REFERENCES:

VITR0' DRAWING 380I-3005 SHEET 1 1 SENSING ELEMENT: AR-403 Rev. 32 Page'143

. f% t ENCLOSURE 1 - \\g (Page 142 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-03 H-06-03 ~ EMERG FW L ACTUATION EVENT POINT 2014 INDICATED CONDITION: EFIC CHANNEL "B", EMERCENCY FEEDWATER BUS 1 OR BUS 2 TRIPPE0. o /^\\ b fREDUNDANTINDICATIONWHICHWILLVERIFYALARM: HALF OR FULL TRIP ON EFIC CHANNEL "B" EMERGENCY FEEDWATER ACTUATION. o OPERATOR ACTIONS FOR A VALID ALARM: .o REFER TO E0P. INVESTICATE CAUSE OF TRIP CONDITION. o DISCUSSION: WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR.'MUST OBSERVE THE EFIC PUSHBUTTONS TO DETERMINE EFIC A STATUS. EFIC ACTUATE 5 BY ANY OF THE FOLLOWING CONDITIONS: ) 'EITHER OTSC <600 PSIC EITHER OTSC APPROACHING 0" MANUAL ACTUATION l LOSS OF ALL RCPs 'NI POWER.>45% W/FW <17% HPI A AND B ACTUATION

LOSS OF BOTH MVPs W/RPS NOT IN 5/D BYPASS

.(

IREFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT: AR-403, Rev. 32 Page 144

i ]j I ENCLOSURE 1 (Page 143 of 190) PSA-Z ANNUNCIATOR RESPONSE-PSA-2-06-04 H-06-04 EF PUMP 1 TRIP DEFEATED - EVENT POINT 1179 INDICATED CONDITION: EFP-1 TRIP DEFEAT CONTROL SWITCH IS IN " DEFEAT" POSITION OV REDUNDANT INDICATION WHICH WILL: VERIFY ALARM: VISUAL OBSERVATION OF ONE, TWO, OR THREE EFP 1 TRIP DEFEAT CONTROL _ SWITCHES IN DEFEAT POSITION. E5_ ACTUATION TEST CABINETS 1, 2, AND 3 EACH CONTAIN ONE . CONTROL SWITCH. OPERATOR ACTIONS FOR A VALID ALARM: VERIFY THE REQUIREMENTS FOR PLACING CONTROL SWITCH TO " DEFEAT" AR __EFP-2 NOT AVAILABLE, FEEDWATER-IS RF. QUIRED,'A LOSS OF'OFFSITE POWER EVENT IS IN: PROGRESS AND LPI INITIATION IS IMMINENT OR-HAS OCCURED DISCUSSION: ESAS CENERATES A. TRIP SIGNAL'TO EFP-I-WHEN AS RCS LOW LOW'ESAS IN SIGNAL COINCIDENT. WITH A LOOP IS - PRESENT. THIS IS PART OF THE LOAD MANACEMENT_ SCHEME FOR EDC-1A..THE TRIP CAN BE DEFEATED IF EFP-2 15 UNAVAILABLE AND FEEDWATER I5_ REQUIRED.. DEFEATING THE TRIP 15 AC BY PLACING THE CONTROL' SWITCH TO DEFEAT-IN ES-ACTUATION CABINETS 1, 2, AND 3. OPERATION"0F-ANY ONE SWITCH CAUSE5' ANNUNCIATION OF THIS ALARM. OPERATION OF THE' REMAINING SWITCHES CAUSE THIS ALARM REFLASH.

REFERENCES:

DRAWINC 211-028 ES-A35 SENSING ELEMENT: AR-403 Rev. 32 Page 145

/ ENCLOSURE 1 5 (Page 144 of 190) 4 PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-04 H-06-04 EF PUhAP 1 TRIP DEFEATED EVENT POINT 1181 INDICATED CONDITION: EFP-1 Ti;u DEFEAT CONTROL SWITCH IS IN ' DEFEAT" POSITION l REDUNDANT INDICATION WHICH WILL VERIFY ALARM: VISUAL OBSERVATION OF ONE, TWO, OR THREE EFP-1 TRIP DEFEAT CONTROL SWITCHES i i IN DEFEAT POSITION. E5 ACTUATION TEST CABINETS 1, 2, AND 3 EACH CONTAIN ONE CONTROL SWITCH. OPERATOR ACTIONS FOR A VALID ALARM: t ' VERIF) THE REQUIREMENTS FOR PLACING CONTROL SWITCH TO " DEFEAT" ARE MET: EFP-2 NOT AVAILABLE, FEEDWATER 15 REQUIRED, A LOSS OF OFFSITE POWER EVENT IS IN PROGRESS AND LPI INITIATION IS IMMINENT OR HAS OCCURRED , DISCUSSION: i tESAS CENERATES A TRIP SIGNAL TO EFP-I WHEN AS RCS LOW LOW ESAS INITIATION l SICNAL COINCIDENT WITH A LOOP IS PRESENT. THIS IS PART OF THE LOAD L j MANACEMENT SCHEME FOR EDC-1A. THE TRIP CAN BE DEFEATED IF EFP-2 I5 i UNAVAILABLE AND FEEDWATER 15 REQUIRED. DEFEATING THE TRIP IS ACCOMPLISHED BY PLACING THE CONTROL SWITCH TO DEFEAT IN E5 ACTUATION CABINETS 1, 2, AND [. l 3. OPERATION"0F ANY ONE SWITCH CAUSES ANNUNCIATION OF THIS ALARM. OPERATION OF THE REMAININC SWITCHES CAUSE THIS ALARM REFLASH. ~ l

REFERENCES:

DRAWINC 211-028 ES-A36 SENSING ELEMENT: AR-403 Rev. 32 Page 146

W i ENCLOSURE 1 (Page 145 of 190) ' PSA-Z ANNUNCIATOR - RESPONSE - PSA-Z-06-04 H-06-04 1 EF' PUMP 1 TRIP DEFEATED EVENT POINT 1301 -INDICATED CONDITION: EFP-1 TRIP DEFEAT CONTROL SWITCH 15.IN " DEFEAT" POSITION O ~ REDUNDANT INDICATION WHICH WILL VERIFY ALARM: VISUAL OBSERVATION OF ONE, TWO, OR THREE EFP-1 TRIP DEFEAT CONTROL SWITCHES IN DEFEAT POSITION. ES ACTUATION TEST CABINETS 1, 2, AND 3 EACH CONTAIN ONE ' CONTROL SWITCH. OPERATOR ACTIONS FOR A VALID ALARM: VERIFY THE REQUIREMENTS FOR PLACING' CONTROL SWITCH TO " DEFEAT" ARE ME EFP-2 NOT AVAILABLE, FEEDWATER 15 REQUIRED, A LOSS OF OFFSITE POWER EVENT IS IN PROGRESS AND LPI INITIATION IS IMMINENT OR HAS OCCURED ' DISCUSSION: ESAS CENERATES A TRIP SIGNAL TO EFP-1 WHEN AS RCS LOW LOW ESAS INITIATION f SIGNAL COINCIDENT WITH A LOOP IS PRESENT. THIS IS PART OF THE LOAD-MANAGEMENT SCHEME FOR EDC-1A. THE TRIP CAN BE DEFEATED IF EFP-2 IS UNAVAILABLE AND FEEDWATER 15 REQUIRED. DEFEATING THE TRIP IS ACCOMPLISHED BY PLACINC THE CONTROL SWITCH TO DEFEAT IN E5 ACTUATION CABINETS 1, 2, AND. 3. OPERATION'0F ANY ONE WHICH CAUSES ANNUNCIATION OF THIS ALARM. OPERATION. -1 0F'THE REMAININC SWITCHES CAUSE THIS ALARM REFLASH. 1 yg REFERENCES.: DRAWINC 211-028 ES-A37-SENSING ELEMENT: i AR-403 Rev. 32 Page'147

u

- (Q -

-ENCLOSURE 1 f (Page 146 of 190). PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-06 H-06-06 EFIC BYPASS EVENT POINT 2012 INDICATED CONDITION: EFIC CHANNEL A IN MAINTENANCE BYPASS. o o ANY EFIC CHANNEL A TEST SWITCH NOT IN NORMAL. [O~h ANY EFIC CHANNEL A CIRCUIT BREAKER OPEN. o o - ANY EFIC-CHANNEL A MODULE WITHDRAWN. EFIC CHANNEL A CABINET POWER SUPPLY FAILURE. o o. E FIC CHANNEL A MAINTENANCE BYPASS ISOLATOR FAILURE. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF ALARM CONDITION. o . DISCUSSION: o-VAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE IS INDICATED BY MAINTENANCE BNPA55 ALARM WITHOUT THE LOCAL CHANNEL MAINTENANCE BYPASS LED FLASHIN i

REFERENCES:

VITRO DRAWING 3801-3005 SHEET I iSEN51NC, ELEMENT: AR-403, Rev. 32-Page I48

g .,j= ENCLOSURE 1 (Page 147 of 190) PSA-Z ANNUNCIATOR. RESPONSE ~PSA-Z-06-06 H-06-06 v EFIC BYPASS' EVENT POINT 2020 INDICATED CONDITION: EFIC CHANNEL B IN MAINTENANCE BYPASS. o o ANY' EFIC CHANNEL B -TEST SWITCH NOT IN NORMAL. o ANY EFIC CHANNEL B CIRCUIT BREAKER OPEN. f { o ANY EFIC ' CHANNEL B MODULE WITHDRAWN. o EFIC CHANNEL B CABINET POWER SUPPLY FAILURE. EFIC^ CHANNEL B MAINTENANCE BYPASS ISOLATOR FAILURE. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF ALARM CONDITION. o DISCUSSION: o ' MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE IS INDICATED BY MAINTENAN BYPASS ALARM WITHOUT THE LOCAL _ CHANNEL MAINTENANCE BYPASS LED FLASH )/

REFERENCES:

VITRO DRAWING 3801-3005 5HEET 2 i

SENSING-ELEMENT: 1 AR-403 Rev. 32 Page 149

(a L i l. ' I /~~j - ENCLOSURE 1 l y/ (Page 148 of 190) PSA-Z ANNUNCIATOR RESPONSE P5A-Z-06-06 H-06-06 l l-EFIC BYPASS t + EVENT POINT 2025 INDICATED CONDITION: EFIC CHANNEL C.IN MAINTENANCE BYPASS. o ANY EFIC CHANNEL C TEST SWITCH NOT IN NORMAL. o l '%)_ ANY EFIC CHANNEL C CIRCUIT' BREAKER OPEN. o o ANY EFIC CHANNEL C MODULE WITHDRAWN. EFIC CHANNEL C CABINET POWER SUPPLY FAILURE. v -

o EFIC CHANNEL C MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE.

o i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR _ ACTIONS FOR A VALID ALARM: 'o. INVESTICATE CAUSE OF ALARM CONDITION. DISCUSSION: o MAINTENANCE BYPASS DICITAL ISOLATOR FAILURE IS INDICATED BY MAINTEN i (. BYPASS ALARM WITHOUT THE LOCAL CHANNEL MAINTENANCE BYPASS LED

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 3 SENSING ELEMENT: AR-403 Rev. 32 Page 150

-q. ? /~Nj'l !(,,j ENCLOSURE 1 (Page 149 of 190) q PSA-Z ANNUNCIATOR RESPONSE, PSA-Z-06-06 H-06-06 i EFIC BYPASS EVENT POINT 2029 INDICATED CONDITION: EFIC CHANNEL D IN MAINTENANCE BYPASS. o ANY EFIC CHANNEL D TEST SWITCH NOT IN NORMAL. o ANY EFIC CHANNEL D CIRCUIT BREAKER OPEN. o j-~g. o ' ANY EFIC CHANNEL' D MODULE WITHDRAWN. EFIC CHANNEL D CABINET POWER SUPPLY FAILURE. o o EFIC CHANNEL D MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE. REDUNDANT ~ INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF ALARM CONDITION. o DISCUSSION: o MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE IS INDICATED BY MAINTENA BYPASS ALARM WITHOUT THE LOCAL CHANNEL MAINTENANCE BYPASS LED FLA I I

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 4 V. , SENSING ELEMENT: AR-403-Rev. 32 Page 151-

I l ENCLO5URE 1 (Page 150 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-06 H-06-06 EFIC BYPASS EVENT POINT 2030 INDICATED CONDITION: EFIC CHANNEL A EFW TEST SWITf.H IN " TEST" POSITION. o "M.S. ISOLATION VALVES AIR S JPPLY TEST A" 5 WITCH SELECTED TO NUMBER 2, o "vSI SV-2 EFIC HALF / TRIP" OR NUMBER 1, "MS & FW ISOLATION". .Y l REDUNDANT INDICATION WHICH WILL VERIFY ALARM: KEY OPE. RATED TEST SWITCH IN RELAY RACK RR3A 15 SELECTED TO THE " TES o POSITION. (CRD ROOM) OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF ALARM CONDITION. o NOTIFY 5500 0F KEY SWITCH POSITION. o DISCUSSION: SELECTING.THE " TEST" POSITION BLOCKS THE OUTPUT OF "A" EFW BUS 1 AND o BUS 2. )

REFERENCES:

DRAWINC 208-032-Fa-47, 208-026-EF-15 l_SENSINCELEMENT: AR-403 Rev. 32 Page 152

. fm ?g ENCLOSURE 1 (Page 151 of.190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-06 H-06. EFIC BYPASS EVENT POINT 2031 INDICATED CONDITION: o EFIC CHANNEL B EFW TEST SWITCH IN TEST POSITION. "M.S. ISOLATION VALVES AIR SUPPLY TEST B" SWITCH SELECTED TO NUMBER 2, .o "MSI SV-1 EFIC HALF TRIP" OR NUMBER 1, "M5 & FW ISOLATION". e REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o KEY OPERATED TEST SWITCH IN RELAY RACK RR581 IS SELECTED TO THE " TEST" POSITION. (EFIC ROOM B) OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF ALARM CONDITION. o NOTIFY.550D OF KEY SWITCH POSITION. o DISCUSSION: o SELECTING,THE " TEST" POSITION BLOCKS THE OUTPUT OF "B" EFW BUS 1 AND BUS 2.

REFERENCES:

.DRAWINC 208-032'-FW-48, 208-026-EF-16 SENSING ELEMENT: '. AR-403 Rev. 32 Page 153_.

e J '[. e ef; ENCLOSURE 1 (j: (Page 152 of 190); PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-06 H-06-06 EFIC BYPASS EVENT POINT 2032 j INDICATED CONDITION: o EFIC AUXILIARY RELAY BOX IC TEST SWITCH IN TEST. i l REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 1 ODERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF ALARM CONDITION. o I I 's : DISCUSSION: o ' AUTOMATIC REPOSITIONINC' 0F EFV-II AND EFV-32 BY EFIC IS' BLOCKED WHEN ' TESTL I

REFERENCES:

_DRAAINC 208- 026-E F-2'I ~ l SENSING, ELEMENT: -AR-40) Rev. 32 Page 154

y' 'y/ ENCLOSURE 1 (Page 153 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-06 H-06-06 EFIC BYPASS EVENT POINT 2033 INDICATED CONDITION: o' EFIC AUXILIARY RELAY BOX ID TEST SWITCH IN TEST.

/

/~T V REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF ALARM CONDITION. o DISCUSSION: o AUTOMATIC REPOSITIONING OF EFV-14 AND EFV-33 BY EFIC IS BLOCKED WHEN .'T TEST. 1 .I.'- J (

REFERENCES:

DRAWINC 208-026-EF-22 SENSING ELEMENT: i AR-403b ); Rev. 32 Page 155

- /N ENCLOSURE 1 - (,) (Page 154 of 190) _ PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-06 H-06-06 EFIC BYPASS EVENT POINT 2034 INDICATED CONDITION: o EFIC ES-A BYPASS /TESTINC. O xj i. IREDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM

INVESTIGATE CAUSE OF ALARM CONDITION. o jDISCUSSION: .THIS EVENT POINT IS RECEIVED DURING EFIC TESTING BY PLACING THE SPRING ! MANUAL ACTUATION CABINET 4D. RETURN TO NORMAL SWIT THESE TEST POSITIONS SIMULATE AN ES A" l SIGNAL-TO EFIC CHANNELS "A" OR "B". THIS SWITCH DOES NOT BYPASS ANY .l. ACTUATION SIGNAL FROM ENGINEERED SAFECUARDS.

)

.I j

REFERENCES:

DRAWINC 208-028-E5-A65 SENSING ELEMENT: AR-403 Rev. 32 Page 156

i 1 7'~\\ ENCLOSURE 1 .is,) (Page 155 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-06 H-06-06 EFIC - BYPASS EVENT POINT 2035 INDICATED CONDITION: o EFIC ES-B BYPASS / TESTING. REDUNDANT INDICATION WHiCH.WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE CAUSE'0F hlARM CONDITION. o j. DISCUSSION: THIS EVENT POINT IS. RECEIVED DURING EFIC TESTING BY PLACING THE SPRING RETURN'TO NORMAL SWITCH TO EITHER TEST I OR TEST 2 POSITION IN THE ES-B MANUAL ACTUATION CABINET SD. THESE TEST POSITIONS SIMULATE AN E5 "B" SIGNAL TO EFIC CHANNELS "A" OR "B". THIS SWITCH-DOES NOT BYPASS ANY ACTUATION SIGNAL FROM ENGINEERED SAFECUARDS. / \\

REFERENCES:

DRAWINC 208-028-ES-B65 ~() ~ SENSINC ELEMENT: ARl403' Rev. 32 Page 157

h] r -ENCLOSURE 1 (Page 156 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-07 H-06-07 J EFIC + u SHUTDOWN - BYPASS I I EVENT POINT 2013 INDICATED CONDITION: o - EFIC CHANNEL "A" MAIN STEAM ISOLATION ACTUATION BYPASSED. I. '{REDUNDANTINDICATIONWHICHWILLVERIFYALARM: !o CHANNEL "A" <725 PSI STM CEN PRESS EFIC ACT BYPASS' PUSH-BUTTON ILLUMINATED. .i ' OPERATOR ACTIONS FOR A VALID ALARM: l_ DISCUSSION: . l'THISEVENTPOINTISRECEIVEDWHENPLANTCONDITIONSALLOWTHEBYPA MSLI/M4FI ACTUATION, AND THE BYPASS. PUSH-BUTTON HAS BEEN DEPRESSED. THE i ACTUATION SETPOINT IS <600 PSIC AND THE BYPASS IS ALLOWED WHEN OTSC j PRESSURES ARE APPROXIMATELY <725 PSIC.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

l =. i-AR-403 Rev. 32 Page 15E

t /~} Q ENCLOSURE 1 (Page.157 of 190)- - PSA-Z ANNUNCIATOR RESPONSE P5A-Z-06-07 H-06-07 'EFIC SHUTDOWN BYPASS a EVENT POINT 2021 INDICATED CONDITION: EF1C CHANNEL "B" MAIN STEAM ISOLATION ACTUATION BYPASSED. o f~%. U' REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o ' CHANNEL "B" <725 PSI STM CEN PRESS EFIC ACT BYPA55' PUSH-BUTTON ILLUMINATED. OPERATOR ACTIONS FOR A VALID ALARM: i DISCUSSION.: THIS EVENT POINT 15 RECEIVED WHEN. PLANT CONDITIONS ALLOW THE BYPASSING MSLI/MWFI ACTUATION, AND THE BYPASS PUSH-BUTTON HAS BEEN DEPRESSED. THE . ACTUATION SETPOINT IS <600 PSIG AND THE BYPASS IS ALLOWED WHEN OTSG PRESSURES ARE APPROXIMATELY <725 PSIC.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 2 SENSING ELEMENT: -AR-403 Rev. 32 Page 159'

(S ENCLOSURE 1 -( (Page 158 of 190). PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-07 H-06-07

a EFIC SHUTDOWN BYPASS EVENT POINT 2024 INDICATED CONDITION:

EFIC CHANNEL "C" MAIN STEAM ISOLATION' ACTUATION BYPASSED. o - /'% V 1 1 REDUNDANT INDICATION WHICH WILL VERIFY ALARM: CHANNEL "C" <725 PSI 5TM CEN PRESS EFIC ACT BYPA55' PUSH-BUTTON o ILLUMINATED. i OPERATOR ACTIONS FOR A VALID ALARM: i DISCUSSION: THIS EVENT POINT IS RECEIVED WHEN PLANT CONDITIONS ALLOW THE-BYPASS MSLI/MJI. ACTUATION. AND THE BYPASS PUSH-BUTTON HAS BEEN DEPRESSED . THE ACTUATIO' SETPOINT 15 <600 PSIC AND THE BYPASS IS ALLOWED WHEN OTSC PRESSURES ARE APPROXIMATELY <725 PSIC. t,

REFERENCES:

VITRO DRAWING 380I-3005 SHEET 3 [SENSINGELEMENT: AR-403 Rev. 32 Page 160

r~y EELOSURE 1 ( j (Page 159 of 190) PSA-Z. ANNUNCIATOR RESPONSE PSA-Z-06-07 H-06-07 EFIC SHUTDOWN BYPASS EVENT POINT 2028 INDICATED CONDITION: EFIC CHANNEL "D" MAIN STEAM ISOLATION ACTUATION BYPASSED. o 'O U REDUNDANT INDICATION WHICH WILL VERIFY ALARM: CHANNEL "D" <725 PSI STM GEN PRESS EFIC ACT BYPA55' PUSH-BUTTON o ILLUMINATED. OPERATOR ACTIONS FOR A VALID ALARM: DISCUSSION: THIS EVENT POINT 15 RECEIVED WHEN PLANT CONDITIONS ALLOW THE BYPASSING MSLI/M4FI ACTUATION, AND THE BYPASS PUSH-BUTTON HAS BEEN DEPRESSED. THE ACTUATION SETPOINT 15 <600 PSIC AND THE BYPASS 15: ALLOWED WHEN OT5G PRESSURES ARE APPROXIMATELY <72$ PSIC.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 4 SENSING ELEMENT: AR-403 Rev. 32 Page 161

1: - r< I, ).- ENCLOSURE 1 .(Page 160 of 190) PSA-Z ANNUNCIATOR RESPONSE P5A-2-06-08 H-06-08 EFIC AH SYSTEM TROUBLE EVENT POINT 0767 INDICATED CONDITION: o AHF-54A/AHF-54B DUCT, SMOKE DETECTED, OR TROUBLE AS SENSED BY PYROTRONIC SMOKE DETECTION MODULES AH-934-CE1 OR AH-934-CE2. ) %d REDUNDANT INDICATION WHICH WILL VERIFY ALARM: t OPERATOR' ACTIONS FOR A VALID ALARM: INVESTICATE CAUSE OF SMOKE DETECTED OR TROUBLE ALARM. o 1 I I , DISCUSSION: l j i 4 (

REFERENCES:

DRAWINC 208-005-AH-185 \\. yd T' SENSING ELEMENT: AH-934-CE1, AH-934-CE2 i i AR-403 Rev. 32 Page 162 (. t_

ENCLOSURE 1 (Page 161 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-08 H-06-08 EFIC AH' SYSTEM TROUBLE I EVENT POINT 0768 INDICATED CONDITION: o AHF-54A/AHF-54B DUCT,. TEMPERATURE >85* AS SENSED BY AH-932-T51/T52. >^f Y. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FDP, A VALID ALARM: INVESTICATE CAUSE OF DUCT HICH TEMPERATURE ALARM, o DISCUSSION: ! /"N Q

REFERENCES:

DRAWINC 208-005-AH-185 SENSINC ELEMENT: AH-932-T51, AH-932-T52 AR-403 Rev. 32 Page 163 l i

f]. ENCLOSURE 1 g (Page 162 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-08 H-06-08 EFIC AH { SYSTEM . TROUBLE j -EVENT POINT 0774 INDICATED CONDITION: o AHF-54A/AHF-54B DUCT, FLOW LOW AS SENSED BY AH-933-F51/F52. w) ( REDUNDANT ' INDICATION WHICH WILL VERIFY ALARM: )OPERATORACTIONSFORAVALIDALARM: INVESTICATE CAUSE OF LOW AIRFLOW ALARM. o l DISCUSSION: l THIS ALARM POINT IS ACTUATED WHEN EFIC DUCT AIRFLOW IS LESS THAN 70% 3' OF DESIGN AIRFLOW.

REFERENCES:

DRAWINC 208-005-AH-185 SENSING ELEMENT: AH-933-F51, AH-933-F52 AR-403 .Rev. 32 Page 164

. [] ENCLOSURE 1 y; (Page 163 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-08 H-06-08 I ' EFIC AH SYSTEM TROUBLE EVENT POINT 0775 INDICATED CONDITION: EFIC R00M(5) TEMPERATURE HIGH/ LOW AS SENSED BY AH-944-T51/TS2/T53/T54. o l/ \\ Q REDUNDANT INDICATION WHICH WILL VERIFY ALARM: 1 OPERATOR ACTIONS FOR A VALID ALARM: o LINVESTICATE CAUSE OF EFIC ROOM TEMPERATURE ALARM. f DISCUSSION: 'l THI5' ALARM POINT IS ACTUATED WHEN ANY EFIC ROOM TEMPERATURE IS LESS THAN 6D:F OR GREATER THAN 855F. ONE DETECTOR IS LOCATED IN EACH EFIC ROOM MOUNTED ON THE WALL APPR0XIMATELY 4' FROM THE FLOOR. IF ALARM 15 f IN FOR NO APPARENT REASON ENGINEERING CAN ADJUST DAMPER AND/OR DUCT REGISTER POSITIONS TO BETTER DISTRIBUTE AIR FLOW THROUGHOUT THE ROOMS. 1

REFERENCES:

DRAWINC 205-005-AH-185 SENSING ELEMENT: AH-944-T51, AH-944-T52, AH-944-T53, AH-944-T54 AR-403 Rev. 32 Page 165

-i p 4 h-1 ENCLOSURE 1 j.- (Page 164 of 190)- PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-01 H-07-01 EF TANK l l LEVEL { } LOW LOW I I I I EVENT POINT 0815 INDICATED CONDITION: o EFT-2 LEVEL < 8' - 6" AS SENSED BY EF-98-LT. O i REDUNDANT INDICATION WHICH WILL VERIFY ALARM: EF-98-LII, EMERCENCY FEED TANK LEVEL INDICATION. c EF-99-LII, EP.ERGENCY FEED TANK LEVEL INDICATION. o OPERATOR ACTIONS FOR A VALID ALARM: c' REFER TO EOP. ) DISCUSSION: j

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

REFERENCES:

DRAWINC 205-026-EF-05 { jSENSINGELEYENT: EF-98-LT AR-403 Rev. 32 Page I66

h- /~' (,T,/ ENCLOSURE 1 (Page 165 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-02 H-07-02 EF PUMP 1 AUTO START EVENT POINT 1681 INDICATED CONDITION: o EFP-1 MOTOR ENERGIZED WITH CONTROL SWITCH IN NORMAL AFTER STOP POSITIO [Vh-REDUNDANT INDICATION WHICH WILL VERIFY ALARM: RED LICHT ON WITH A CREEN FLAC ON EFP-1 CCNTROL STATION. o OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO E0P. DISCUSSION: f f) } _,/.

REFERENCES:

ORAWINC 208-026-EF-01B SENSING ELEMENT: EFP-1 CONTROL SWITCH CONTACTS CS/ST, CS/0 AR-403 Rev.-32 Page 167

i j '.. ENCLOSURE 1 { k (Page 166 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-03 H-07-03 f 'l ( -.j l l EF PUMP 1 START FAILURE EVENT POINT 1680 INDICATED CONDITION: h l-o '.EFP-1 MOTOR NOT ENERGIZED WITH CONTROL SWITCH IN NORMAL AFTER STOP I POSITION, A_@ 50 SECONDS HAVE ELAPSED WITH AN ACTUATION SIGNAL PRESENT.

/'][

lREDUNDANTINDICATIONWHICHWILLVERIFYALARM: I i . OPERATOR-ACTIONS FOR A VALID ALARM: o. REFER T0 E0P. ) o MANUALLY '5 TART EFP-1 DISCUSSION: (- 'IF EFo-1 FAILED TO START FROM A VALID ACTUATION SIGNAL, BUT WAS MANUALLY 3 l STARTED THEN THIS~ ALARM WILL NOT ACTUATE DUE TO THE 50 SECOND TIME DEL I REL AY CIRCUIT. THE CONTROL SWITCH MUST BE IN THE NORMAL AFTER STOP I

POSITION.T0jACTUATETHISALARM.

'l /7 (v)

REFERENCES:

DRAWINC 208-026-EF-01B ) i SEN5ING ELEMENT: EFP-1 CONTROL SWITCH CONTACTS CS/ST, CS/0 AR-403 Rev. 32 Page 168

f"N \\j ENCLOSURE 1 (Page 167 of 190) .PSA-Z ANNUNCIATOR RESPONSE PSA-2-07-03 H-07-03 EF PUMP 1 START FAILURE EVENT POINT 1682' INDICATED CONDITION: o : EFP-1 DISCHARCE PRES 5URE <1100 PSIG AS SENSED BY EF-17-P5 WITH CONTRO SWITCH IN NORMAL AFTER START POSITION. REDUNDANT INDICATION WHICH WILL VERIFY. ALARM: OPERATOR ACTIONS FOR A~ VALID ALARM: o REFER TO E0P. INVESTICATE CAUSE OF LOW DISCHARCE PRESSURE. o DISCUSSION: THE CONTROL. SWITCH MUST BE IN THE NORMAL AFTER START POSITION TO THIS EVENT. POINT. ,D ! ()

REFERENCES:

DRAWINC 208-026-2F-01B SENSING ELEMENT: EFP-1 CONTROL SWITCH CONTACTS CS/SC, C5/0,~EF-17-P5 AR-403' Rev 32 Page 169

~js ((,)y ENCLOSURE 1 (Page 168 of 190) PSA-Z ANNUNCIATOR RESPONSE -PSA-2-07-04 H-07-04 EF PUMP 1 TRIP EVENT POINT 1261 INDICATED CONDITION: o. EFP-1 MOTOR NOT ENERCIZED WITH CONTROL SWITCH IN NORMAL AFTER START POSITION. ' N's /- 1 i lREDUNDANTINDICATIONWHICHWILLVERIFYALARM: h o CREEN LICHT ON WITH A RED FLAC ON EFP-1 CONTROL STATION. \\ . OPERATOR ACTIONS FOR A VALID ALARM: o REFER TO EOP. j o INVESTICATE' CAUSE OF BREAKER TRIP. i !: i jDISCUSSION: THE CONTROL SWITCH MUST BE IN THE NORMAL AFTER START POSITION TO ACTUA t - THIS EVENT ' POINT. i i l ,--() I

REFERENCES:

DRAWINC 208-026-EF-01 i t' SENSINC-ELEMENT: EFP-1 CONTROL SWITCH CONTACTS CS/SC, CS/0 1 { AR-403 Rev. 32 1 Page 170 (

l-L.. ..r S - f ENCLOSURE 1 '(Page 169 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-07-05 H-07-05 l. ,t i l a i EF PUMP 1 OUT OF SERVICE l EVENT POINT 1191 j INDICATED CONDITION: ,i-i EFP-1 CONTROL SWITCH IN PULL TO LOCK POSITION o 'h' 't ^l REDilNDANT INDICATION WHICH WILL VERIFY ALARM: CREEN AND RED LIGHTS EXTINCUISHED ON CONTROL STATION. i-o I OPERATOR ACTIONS FOR A VALID ALARM: i s i i-DISCUSSION. i l 1 f'\\ i l j-

REFERENCES:

ORAWINC 208-026-EF-01 SENSING ELEMENT: EFP-1' CONTROL SWITCH CONTACT 5 C5/PTL l AR-403 Rev. 32 l.. Page 171. t

1 (x, - ENCLOSURE 1 .1] (Page 170 of 190)- PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-05 H-07-05 I J EF PUMP 1 OUT OF SERVICE i l EVENT POINT 1257 INDICATED CONDITION: EFP-1 CIRCUIT BREAKER NOT RACKED IN, o - ^) I f .V REDUNDANT INDICATION WHICH WILL VERIF IALARM: i-o CREEN AND RED LICHTS EXTINGUISHED ON CONTROL STATION, ) OPERATOR ACTIONS FOR A VALID ALARM: I DISCUSSION:

i..

l.. L l 'h

REFERENCES:

.DRAWINC'208-026-EF-01 t j SENSING ELEMENT: EFP-l' BREAKER 52H/B CONTACTS r i AR-4 03,. Rev. 32 Page 172 ['

ENCLOSURE 1 ,j (Page 171 of 399} l PSA-Z ANNUNCIATOR RESPONSE PSA-2-07-05 H-07-05 r EF PUMP 1 083T OF SERVICE EVENT POINT 1259 INDICATED CONDITION: EFP-1 CIRCUIT BREAKER LOSS OF DC CONTROL POWER. o f w/ REDUNDANT INDICATION WHICH WILL VERIFY. ALARM: o CREEN.- AND RED LICHTS EXTINGUISHED ON CONTROL STATION. OPERATOR-ACTIONS FOR A VALID ALARM: DISCUSSION: .\\,

REFERENCES:

'DRAWINC 208-026-EF-01 SENSING ELEMENT:

EFP-1 BREAKER CONTROL CIRCUIT 27'RELAN' AR-403 Rev. 32 Page 173 o I s.

i /-+s _ ), ENCLOSURE 1 .g (Page 172 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-06 H-07-06 l EF PUMP 1 t MOTOR OVERLOAD EVENT POINT 1260 INDICATED CONDITION: o EFP-1 MOTOR AMP 5' >115% RATED LOAD. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o HICH MOTOR AMPS. o EFP-1 BREAKER TRIP. l OPERATOR ACTIONS FOR A VALID ALARM: 4 i o REFER TO E0P.

o. START EFP-2.

! o R{ DUCE EMERCENCY FEEDWATER FLOW FROM EFP-1 IF STILL' RUNNINC. i DISCUSSION: THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOU + OVERCURRENT PROTECTIVE DEVICES HAVE ACTUATED. INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER. IT IS POSSIBLE TO HAVE THIS ALAR $ PRIOR TO THE BREAKER TRIP. \\O

REFERENCES:

DRAWINC 208-026-EF-01 SENSINC ELEMENT: .EFP-1 BREAKER 51 RELAY (INSIDE 4160 BREAKER CUBICLE) AR-403 Rev. 32 Page 174

f ((3 ENCLOSURE 1 ) (Page 173 of 190) . PSA-Z ANNUNCIATOR' RESPONSE PSA-Z-07-07' H-07-07 FWP7 TRIP i p EVENT POINT 0819 INDICATED CONDITION: i ~FWP-7' MOTOR NOT ENERGIZED WITH CONTROL STATION IN NORMAL AFTER ST -o POSITION. l* REDUNDANT INDICATIOS WHICH WILL VERIFY ALARM: o CREEN LIGHT ON WITH A RED FLAC ON FWP-7 CONTROL STATION. ~ OPERATOR ACTIONS FOP. A VALID ALARM: o INVESTICATE CAUSE OF BREAKER TRIP, I DISCUSSION: (

REFERENCES:

' DRAWINC 208-032 FW-55 l

SENSING ELEMENT: CS/SC', CS/0-AR-403. Rev. 32 Page 175 3

E W ENCLOSURE 1. (Page 174 of 190)' PSA-Z ANNUNCIATOR' RESPONSE PSA-Z-07-08 H-07-08 .l FWP-7 OVERCURRENT EVENT POINT 0780 g . INDICATED CONDITION: o FWP-7 MOTOR AMPS >115% RATED LOAD \\) REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o 'HICH MOTOR AMPS o FWP-7 BREAKER TRIP i OPERATOR ACTIONS FOR A VALID ALARM: REDUCE FEEDAATER FLOW FROM FWP-7 IF STILL RUNNING r . o

DISCUSSION

i THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEO .l OVERCURRENT ' PROTECTIVE DEVICES HAVE ACTUATED. INSTANTANEOUS OVERCURRE g PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER. .1 .IT IS POSSIBLE TO~HAVE THIS ALARM PRIOR TO THE BREAKER TRIP. 1 i l

REFERENCES:

DRAWINC 208-032 FW-55 -5ENSINC ELEMENT: FWP-7' BREAKER 51 RELAY (INSIDE 4160 BREAKER CUBICLE) l AR-403 Rev. 32 Page 176

x . sf b ENCLOSURE 1 m/ (Page 175 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-01 H-08-01 EF TANK y LEVEL j g HIGHILOW i l I I EVENT POINT 0816 INDICATED CONDITION: o : EFT-2 LEVEL > 37' - 0" AS SENSED BY EF-98-LT. O ~ REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o. EF-98-LIl EMERCENCY FEED TANK LEVEL INDICATION.

EF-99-LIl EMERCENCY FEED TANK LEVEL INDICATION. o OPERATOR ACTIONS FOR A VALID ALARM: RESTORE TANK LEVEL TO NORMAL OPERATING BAND. o i DISCUSSION: i i 'l ( - i'

REFERENCES:

DRAWINC 205-026 EF-05 SENSING ELEMENT: EF-98-LT AR-403 Rev. 32 Page 177

. ENCLOSURE 1 Q. (Page 176 of 190) .PSA-Z ANNUNCIATOR RESPONSE-PSA-2-08-01 H-08-01 l EF TANK g. LEVEL. l l HIGH/ LOW l l I I EVENT POINT 0817 INDICATED CONDITION: EFT-2 LEVEL <33 '-8" AS SENSED BY EF-99-LT. o REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o EF-98-LII EMERCENCY FEED TANK LEVEL INDICATION. e EF-991LII EMERCENCY FEED TANK LEVEL INDICATION. OPERATOR ACTIONS FOR A VALID ALARM: RESTORE TANK LEVEL TO NORMAL OPERATING BAND. o D!5CUSSION: THE LO4 LEVEL ALARM SETPOINT IS > THAN TECH. SPEC. LIMIT OF 150,000 CAL L O'.5. REFER TO TS.FOR ADMINISTRATIVE REQUIREMENTS. 1 i M) I 'i l

REFERENCES:

DRAWINC 205-026 EF-05 SENSING ELEMENT: EF-99-LT AR-403 Rev. 32 Page 178 1

1 ^ .N I(d ENCLOSURE 1 (Page 177 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-02 H-08-02 EF PUMP 2 AUTO START EVENT POINT'1707 INDICATED CONDITION: . o _ EFP-2 DISCHARGE PRESSURE >1100 PSIG AS SENSED BY EF-18-PS. - A!iD 50 SECONDS HAVE ELAPSED WITH AN ACTUATION SIGNAL PRESENT.

i )

REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: o - REFER. TO E0P. DISCUSSION: .fr i )

REFERENCES:

DRAWINC 208-008 AS SENSING ELEMENT: EF-18-P5 AR-403 Rev. 32 Page 179

q-ENCLOSURE 1. .f, /. (Page 178 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-03 H-08-03 EF PUMP 2 START FAILURE i EVENT POINT 1706 INDICATED CONDITION: o EFP-2 DISCHARCE PRESSURE <1100 PSIG AS SENSED BY EF-18-PS 8N_D 50 SECONDS HAVE ELAPSED WITH AN ACTUATION SIGNAL PRESENT. k l REDUNDANT INDICATION WHICH WILL VERIFY ALARM: IOPERATOR' ACTIONS FOR A VALID ALARM: r o REFER TO E0P. i. t ' DISCUSSION:

REFERENCES:

DRAWINC 208-008 AS-01 SENSINC' ELEMENT: EF-18-PS-AR-403 Rev. 32 Page 180

fy( (- ENCLOSURE 1 (Page 179 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-04 H-08-04 1 EF PUMP 2 TRIP EVENT POINT 0326 INDICATED CONDITION: o TURBINE DRIVEN EMERGENCY FEEDWATER PUMP STEAM SUPPLY VALVE A5V-50 NOT OPEN. O REDUNDANT INDICATION WHICH WILL VERIFY ALARM: OPERATOR ACTIONS FOR A VALID ALARM: NOTIFY PRIMARY PLANT OPERATOR TO RESET ASV-50 o DISCUSSION: 4 SENSING ELEMENT: 33C/ASV-50 AR-403 Rev. 32 i Page 181

'p ENCLOSURE 1 ,j (Page 180 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-05 H-08-05 EF PUMP 2 OUT OF SERVICE EVENT POINT 0100 INDICATED CONDITION: o ASV-5 CLOSED, WITH DC CONTROL' POWER NOT AVAILABLE FOR >5 SECONDS. M% -55 CLOSED. o lo.15V-56 CLOSED. I hREDUNDANTINDICATIONWHICHWILLVERIFYALARM: o ASV-5 POSITION INDICATION. o MSV-55 POSITION INDICATION. t o M5V-56 POSITION INDICATION. t 4 j.0PERATORACTIONSFORAVALIDALARM: INVESTICATE LOSS OF CONTROL POWER TO ASV-5. o j INVESTICATE CLOSURE OF M5V-55 OR MSV-56. o { jDISCUSSION: IF THIS ALARM IS'DUE TO THE ASV-5 CIRCUITRY THEN 4T MEANS ASV-5 IS CLOSED j wITH NO CONTROL POWER AVAILABLE TO ALLOW AN AUTC OPEN DURING AN EFW i ACTUATION. THE MSV-55 AND MSV-56 ALARMS ARE DUE TO FULLY CLOSED LIMIT SWITCHES. CONTROL POWER FOR ASV-5 IS SUPPLIED FROM DPDP-8B FUSE #6. J O)'Q -

REFERENCES:

DRAWINC 208-008 AS-01 SENSING ELEMENT: ASV-5 L5(13), 2ASV-5 RELAY, M5V-55 LS(5), MSV-56 LS(14) AR-403 Rev. 32 Page 182

l (~N ENCLOSURE 1 / (Page 181 of.190) PSA-Z ANNUNCIdTOR RESPONSE ~ PSA-Z-08-05 H-08-05 EF PUMP 2 OUT OF SERVICE EVENT POINT 1521 INDICATED CONDITION: o A5V-204 CLOSED, WITH DC CONTROL POWER NOT. VAILABLE. REDUNDANT INDICATION WHICH'WILL VERIFY ALARM: o ASV-204 POSITION' INDICATION. 1 OPERATOR ACTIONS FOR A VALID ALARM: INVESTIGATE LOSS OF CONTROL POWER TO ASV-204. o 1. 1 DISCUSSION: THIS ALARM MEANS ASV-204 15 CLOSED WITH NO CONTROL POWER AVAILAB'LE TO i ALLOW AN AUTO C'EN DURING AN ACTUAT10N. CONTROL POWER FOR ASV-20e IS -SUPPLIED FROM DPDP-SA FUSE a15. I ~ n. ).

REFERENCES:

DRAWINC 208-008 AS-07 l SENSING ELEMENT:,ASV-204 LS(13), 27ASV-204 RELAY AR-403.. 'Rev. 32-Page 183

.,s i ENCLOSURE 1 (Page 182 of 190) PSA-Z' ANNUNCIATOR RESPONSE PSA-Z-08-06 H-08-06 l Eh4 ERG FVV VALVE NOT FULL OPEN l EVENT POINT 1192 INDICATED CONDITION: o EFV-32 NOT FULL OPEN. .(-'s , \\~) , REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o EFV-32 POSITION INDICATION. OPERA', '.R ACTIONS FOR A VALID ALARM: INVESTIGATE CLOSURE OF EFV-32. o DISCUSSION: i 1 i ? l 1. ()

REFERENCES:

DRAWINC 208-026 EF-10 ]SENSINCELEMENT: EFV-32 FULL OPEN LIMIT SWITCH 1 .AR-403 Rev. 32 Page 184

t

s ENCLOSURE 1 U (Page 183 of.190) PSA-Z ANNUNCIATOR RESPONSE 'P5A-Z-08-06 H-08-06 EMERG FW VALVE NOT FULL OPEN EVENT POINT 1193 INDICATED CONDITION: { o EFV-11 NOT FULL OPEN. REDUNDANT INDICATION WHICH WILL VERIFY ALARM!~ o EFV-11 POSITION INDICATION. OPERATOR ACTIONS FOR A VALID ALARM: o' INVESTICATE CLOSURE OF EFV-11. DISCUSSION: [N,

REFERENCES:

DRAWINC 208-026 EF-08 ] .j SENSING ELEMENT: EFV-11 FULL' OPEN LIMIT SWITCH AR-403. Rev. 32 Page 185 j i

ENCLOSURE 1 (Page 184 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-06 H-08-06 4 EMERG FW m VALVE NOT FULL OPEN - t EVENT POINT 1194 INDICATED CONDITION: o EFV-14 NOT FULL OPEN. ( REDUNDANT INDICATION WHICH WILL VERIFY ALARM: j. o EFV-14 POSITION INDICATION. I l OPERATOR ACTION 5' FOR A VALID ALARM: i lo INVESTICATE CLOSURE OF EFV-14. DISCUSSION: l I i i . (

REFERENCES:

DRAWINC 208-026 EF-9 SENSINC' ELEMENT: EFV-14 FULL OPEN LIMIT SWITCH

AR-403' Rev. 32 Page 186

g3 ENCLOSURE 1 i (Page 185 of 190) PSA-Z ANNUN.IATOR RESPONSE PSA-Z-08-06 H-08-06 l ~ EMERG FW VALVE NOT FULL OPEN EVENT POINT 1196-INDICATED CONDITION: o EFV-33 NOT FULL' OPEN. -(s{ '%) REDUNDANT INDICATION WHICH WILL. VERIFY ALARM: o EFV-33 POSITION INDICATION. OPERATOR ACTIONS FOR A. VALID ALARM: ,o INVESTICATE CLO5URE OF EFV-33. LISCUSSION: o p, )~

REFERENCES:

DRAWINC 208-026 EF-11 1 SENSINC' ELEMENT: EFV-33 FULL OPEN LIMIT SWITCH AR-403' Rev. 32; Page 187

I-l l ('[ ENCLOSURE 1 (f (Page 186 of 1901 i PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-06 H-08 e, EMERG FW VALVE NOT FULL OPEN EVENT POINT 1255 INDICATED CONDITION: o EFV-3 NOT FULL OPEN. 4 ^) ( .() REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o EFV-3 POSITION INDICATION. i t OPERATOR ACTIONS FOR A VALID ALARM: o LINVESTICATE CLOSURE OF EFV-3. i i DISCUSSION: l ) ) 'f~% ().

REFERENCES:

'DRAWINC 208-026 EF-02 SENSINC ELEMENT: 'EFV-3 FULL' OPEN LIMIT SWITCH ARI403 Rev. 32 Page 188

o - (Q) / ENCLOSURE 1 (Page 187 of 190) PST-Z ANNUNCIATOR RESPONSE PSA-Z-08-06 H-08-06 EMERG FW VALVE NOT FULL OPEN EVENT POINT 1256 INDICATED CONDITION: o EFV-4 NOT FULL OPEN. REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o EFV-4 POSITION INDICATIom. 1 I OFERATOR ACTIONS FOR A VALID ALARM: 'o 'INVESTICATE CLOSURE OF EFV-4. RF.FERENCES: _DRAWINC 205-026 EF-03 SENSINC-ELEMENT: EFV-4 FULL OPEN LIMIT SWITCH AR-403 Rev. 32 Page 189

ENCLOSURE 1 (Page 188 of 1901 PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-06 H-08-06 EhAERG FVV VALVE NOT FULL OPEN I l EVENT POINT 1262 INDICATED CONDITION: o EFV-7 NOT FULL OPEN. O , REDUNDANT INDICATION WHICH WILL VERIFY ALARM: I o EFV-7 POSITION INDICATION. OPERATOR ACTIONS FOR A VALID ALARM: INVESTICATE CLOSURE OF EFV-7. o i , DISCUSSION: l ([]) lRErERcNcES:oRAw1NG 208 026 EF-04 SENSING ELEMENT: EFV-7 FULL OPEN LIMIT SWITCH AR-403 Rev. 32 Page 190

p O ENCLOSURE 1 (Page 189 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-06 H-08-06 I EMERG FW . VALVE NOT FULL OPEN EVENT POINT 1263 INDICATED CONDITION: o EFV-8 NOT FULL OPEN. O REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o EFV-8 POSITION INDICATION. OPERATOR ACTIONS FOR A VALID ALARM: y o INVESTICATE ~ CLOSURE OF EFV-8. i ~! J DISCUSSION:

REFERENCES:

DRAWING' 208-026 EF-05 .I SENSING ELEMENT: EFV-8 FULL OPEN LIMIT SWITCH 'AR-403 Rev. 32 Page 191

,p ENCLOSURE 1 g (Page 190 of 190) PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-07 H-08-07 4 EFV-12 EF CROSS TIE OPEN o EVENT POINT 1266 INDICATED CONDITION: .o EFV-12 OPEN - bN) REDUNDANT INDICATION WHICH WILL VERIFY ALARM: o RED IICHT LIT ON EFV-12 CONTROL STATION, EFV-12-MST IN "A" ES 480v 5WITCHCEAR ROOM, 124" ELEV CC. -o FLOd INDICATED ON EF-62-FI, LOCATED ON PSA SECTION OF MCB (TO BE INSTALLED BY MAR 97-01-04-01 i OPERATOR ACTIONS FOR A VALID ALARM: 1 VERIFY CROSS-FLOW VIA "A" SIDE EFIC FLOW-INDICATORS. ' o i. .I l DISCUSSION:EFV-12 POWERED FROM OPDP-8C, BKR5 5 (POWER)'& 6 (CONTROL)

s

REFERENCES:

DRAWINC 208-026'EF-24 ) l SENSING ELEMENT: LIMIT SWITCH. CONTACT #9 AR-403 Rev. 32 Page 192 (LAST PACE) _}}