V August-12 1997 License No. MD 31025-01 Docket No. 15000019 Marvin M. Turkanis Radiation Safety Officer Neutron Products, Inc.
22301 Mt. Ephraim Road P.O. Box 68 Dickerson, MD 20842
Dear Mr. Turkanis:
This is in reference to your NRC Form 241, Report of Proposed Activities in Non-Agreement States, received June 13,1997 requesting reciprocity to install eight cobalt source capsules containing 38,170 curies of cobalt 60 at Dow Corning's Midland Plant, Midland, Michigan,10 CFR 150.20(a) grants, in part, a general license to cc,aduc.t the same activity authorized by a specific Agreement State license in non-Agreement States, provided that the specific license does not limit the activity authorized by the general license to a specified installation or locations. License No.
MD-31025 01 limits the performance of activities to 22301 Mt. Ephraim Road,
' Dickerson, Maryland and locations specified in procedure NR 5015. Therefore, reciprocity cannot be granted. - Please find enclosed your NRC Form 241, received June 13,1997. Your Check No. 24760 will be returned by the Office of the Comptroller under separate cover.
If you have any technical questions, please call Eric H. Reber at (610) 337 5276.
Your cooperation with us is appreciated.
Sincerely,
\\
ORIGINAL SIGNED BY:
\\
&cEA(5.h-uslLu i
( M' Francis M. Costello, Chief Nuclear Materials Safety Branch 3
)
Division of Nuclear Materials Safety cc w/o enc 1:
State of Maryland gggTO REGt08i
/ h <'O OFFICIAL RECORD COPY 9708190022 970812 l f ilk PDR STPRG ESOMD PDR
... -.. ~.....
')
. Neutron Products', Inc.
2-License No. MD 31025 01 Docket No. 15000019
Enclosure:
NRC Form 241 received June 13,1997 w/ attachments Djstribution:
PUBLIC ~
Nuclear Safety Information Center (NSIC).
Rl Docket Room (w/ concurrences)
C. Buracker, RI i
'e DOCUMENT NAME: R:\\WPS\\DLTR\\LMD31025.01
(
T.,.cm...v.e we e
. me..
m m. wm c - copy wro.it.eni.nci r - copy wi.it. chi.nci n - No copy
{
OFFICE -
DNMS/RI lN DNMS/RI
[
l l
NAME Reb h Costello W
{
DATE 08/12/97 08/[U97'V &
08/ /97 08/ /97 OFFICIAL RECORD COPY t
a
FEPORf 0F PROPOSED ACTIVITIES IN NON-AMEMNT STATES I.NAMEOFLICENSEE
- 2. TYPE OF REPORT 3.CONTROLNulea 2Ll INI11AL (Leavellant-NumbertobeassignedbyNRC)
Moutron Products, Inc. (s7-011)
.__lREYlSION Page 1 of 1
_l CLARIFICATION 4.A00REl$0FLICENSEE 5.LICENSEECONTACT k rvin N. Turkanis or Heidi k reon 22101 ut. Ephrais Road, tot 66 Dickerson,hryland 20642 4 068 6.TELEPHONENO.
- 7. FACSINILE NUlem 301/349 4 001 301/349 4 007
- 8. ACTIVlilES 10 SE CONOUCTED IN 0-WEENENT STATES UNDER THE BEM LICENSE GIVH IN 10 CFR 150.20
! l ufLL LOQGlilG l l LEAK TElilNG AN0/0R CAlllRAi!0NS lXl IELETHERAPV/lRRA01ATOR 59VICE l l PORTA 8tfGAUGES l l OTHER (Spri/A l l Wl00RAPWY T W S. QA PROG W APPROVAL #71-0121 REGIS. AS US B 0F PACKAGING Yes I, CLIENT WE, ADDRESS, CITY / COUNTY, STATE,llP CODE 10.WORKLOCATIONADORESS DosCorning,MidlandPlant,2602 Building,3901 3901SouthSaginasRoad South Saginas Road, Midland, Michtten 46686
- 11. CLIB1 TELEPHONE NUNBG
- 12. M LO3fl0N TECHNICIAN AUTHORilED 10
- 13. M LOCAll0N TELEPHONE NO.
517/496-8308 PERFORN m : Mr.OsleRepp 517/496-8308 14.
DATE8 SCHEDULED 15.
NO. OF NORK DAYS te. LOCATION REFERENCE NtMSER FRON 10 06/05/97 06/05/97 one LIST 20!T10lin WORK SliES ON SEPARATE SHEET 70 INCL 10E ALL INFOREi!0N CONTAINED IN ITEMS 9-16 AB0VE.
- 11. LIST RA010ACilVE NATBIAL, WHICH t!LL IE POS'ESSED, USED, INSTALLD, SBVICED, OR TESTED IN NON-AGREEMENT STATES.
Source installattun of eight Cobalt source capsules containing 34,170 curiu as of June 5,1997.
- 18. AGREEMENT STATE SPECIFIC LICENSE WHICH AUTHOR!!ES THE UNDERSIGNED TO C0JUCI ACilVlilES WHICH ARE THE SANE, DCEPT FOR LOCA110N OF USE, f$ SPECIFIED IN lien 8. A80VE.
LICENSENUMB8 STATE DPIRAll0NDATE TOTALUSAGEDAYS MD-31-025-01 Mary 1and under Timely knesal TODATE
- 19. CERTIFICATION (MET BE 03HETED BY APPLIC4NT) 20.I,THEUN08 SIGNED,HERE6YCERilFYTHAT:
- a. All inforsetion in this report is true and cosplate,
- b. I have read and understand the provision of the general license 10 CFR 150,20 reprinted on the cover sheet of this fore ut; and I understand that I as required to cosply with those provisi:ns as to all byproduct, source, or special nuclear uterial stich I possess and use in non-Agrusent States or ofIshore saters under the general license for which this report is filed with the U.S. NuclearJeguletory20sejssion,
- c. I understand that activities, including storage, conducted in non-Agressent States under general license 10 CFR 150.20 are lietted 10 a total of180daysincalendaryear.
- d. I understand that I my be inspected by NRC at above listed sort site locations and at the Licenue hoes office address for activities per-formed in non-Agrusent States or offshore waters. I as also aware that I will be responsible for any fus associated eith such inspections,
- s. I understand that conduct of any activities not described above, including conduct of activities on dates or locations different froe those describedaboveoreithoutNRCauthoritation,saysubjectoctoenforcesentaction,includingcivilorcriminalpenalties.
GBilFYING0FFICER-RSOorManagesenth;.
(9ATUR
DATE Marvin M. Turkanis June 5,1997 1
Radiation Safety Officer M
NARNIN01 FALSE STATENENTS IN THIS CERYlFICATE MAY BE SU6 JECT TO CIVIL AND/OR CHININAL PENALTIES. NRC lie 00LATIONS REQUIRE THAT SUONISSIONS TO THE HRC SE COMPLETE AND ACCURATE IN ALL NATERIAL RESPECTS. 1e U.S.C.
SECTION 1001 MAKES IT A CRININAL OFFENSE TO MAKE A NILLFULLY FALSE STATENENT OR REPRESENTATION TO ANY DEPARTMENT OR AGENCY OF TNE UNITED STATES AS TO ANY MATTER NITNIN ITS JURISDICTION.
FOR MC USE ONLY AUTHOR. OFFICIAL (Typed / Printed Nase, Title)
$!WATURE DATE
~
i
, j. p 1 ; gg DEPARTMENT OF THE ENVIRONMENT l.I'"IVCD RADIOLOGICAL HEALTH PROGRAM RADIOACTIVE MATERIAL LICENSE 1
I Page W
pages Supplementary Sheet Licenom No.
% 31-025-01 Amendment No.
41 Neutrco Proincts, Inc.
22301 Mt. Ethraim Road P.O. Bo 68 Dickerscu, Maryland 20842 In accordance with letter dated July 31, 1992, Radioactive Material License Nmber
% 31-025-01 is amstded to read Canditicn iiAt 11.A. 'Ihe radiation protectica prcgram shall be used under the supervision of Marvin
'ntrkanis.
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT D:t)
Tiuqust 6, 1992 b
bU [M_
ADMINISTRATOR, RAbidLOGICAL HEALTH PROGR'AM MDER L1 (supp)(11/90) j
$tV
p 1 102 DEPARTMENT OF THE ENVIRONMENT
..' "lVfD RADIOLOGICAL HEALTH PROGRAM RADIOACTIVE MATERIAL LICENSE 1
I Page of pages Supplementary Sheet Ucense No.
M)-31-025-01 Amendment No.
41 Neutron Prodacts, Inc.
22301 Mt. E4hraim Road P.O. Bo 68 Dickersca, Maryland 20842 In cecordance with letter dated July 31, 1992, Radioactive Material License !Aanter FD-31-025-01 is amended to read Canditicn 11A 11.A. The radiation trotection program shall be used under the supervision of Harvin 7\\1rkanis.
i FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT 0:t) 1,ucunt 6, 1992 N
Me M __
ADMINISTRATOR, RA'DIOLOGICAL HEALTH PROGR'AM MDER t1 (supp)(11/90)
t M
y,p,y, DEPARTMENT OF THE ENVIRONMENT MAR 181992 RADIOLOGICAL HEALTH PROGRAM RECEIVED RADIOACTIVE MATERIAL LICENSE Page
) of 1 pages Supplementary Sheet
~
Ucense No.
Amendment No.
HD-31-025-01 40 Niutron Products, Inc.
22301 Mt. Ephraim Road P.O. Bor 68 Dickerson, MD 20842 In accordance with letter with attachments dated February 13, 1992 Radioactive Material Lio:nso Number HD-31-025-01 is amended to include:
Condition 13:
- 13. Planc, procedures and equipment described to eliminate microbiological growth in source storage and NPI water systems.
1 FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT
]
^
Dit)
March 16. 1992
.i ADMINISTRATOR, RADIOLOGICAL HEALTH PROGRAM CRT/ cme MDER-L1 (supp) (11/9o) l
o N.P. I.
DEPARTMENT OF THE ENVIRONMENT RADIOLOGICAL HEALTH PROGRAM RECEIVED RA0lOACTIVE MATERIAL LICENSE Page 1 of 1 pages Supplementary Sheet Ucense No.
MD.31-025-01 Amendment No.
39 N:utron Products, Inc.
P.O. Box 68 22301 Mt. Ephraim Road Dickerson, Maryland 20842 In accordance with letter dated September 18, 1991, Radioactive Material License Number MD-31-025-01 is amended as follows:
Crndition 10 to readt
- 10. A. Radioactive material may be processed and used at Neutron Products, Inc.,
22301 Mt. Ephraim Road, Dickerson, Maryland 20842.
D. Radiation processing sources may be installed throughout Maryland in accordance with procedure NR 5015.
To Add Condition IIB:
- 11. B. Implementation or procedure NR 5015 referenced in condition 10D shall be as follows:
- 1. Jeffrey W. Corun and/or Donald F. Franklin are authorized to perform all operations using the hot cell manipulators.
- 2. Dale L. Ropp, J. Richard Demory, Jettrey W. Corun and/or Frank Schwoerer are authorized to perform all operations concerned with handling the model 1500 shipping container.
Condition 13 is amended to add:
Letter dated September 18, 1991 containing procedure NR 5015.
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT
/MbXA i D:t)
September 20, 1991 ADMINISTRATOR', RADIOLdGICAL HEALTH PROGRAM CRF/ame MDER11 (supo)(11/90)
~
ffgfb hhff fjy/
N****Ie AUG 2 21991 DEPARTMENT OF THE ENVIRONMENT qyCejyq RADIOLOGICAL HEALTH PROGRAM RADIOACTIVE MATERIAL LICENSE Page 1 of_1 pages Supplementary Sheet Ucense No.
HD-31-025-01 Amendment No, 38 butronProducts,Inc.
22301 Hount Ephraim Road Dickerson, MD 208112 In cocordance with your letters dated September 25, 1990, June 5, 1991, and June 7, 1991 and cur letter dated January 9, 1991 Itadioactive Material License Number MD-31-025-01 is amended as follows:
Condition 13 is amended to include:
- 13. Letters dated September 15,1990, June 5,1991 and June 7,1991 concerning the wiring diagrams for the hot-cell interlock.
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT b
Dat)
August 19, 1991
[
T-h A6MINISTRATOR, RADIO (OGICAL HEALTH PROGRAM CRP/ame MDER11 (supp)(11/90)
?
5
lk2Cde.20 DEPARTMENT OF THE ENVIRONMENT 9ADIOLOGICAL HEALTH PROGRAM N.RI.
RADIOACTIVE MATERIAL LICENSE 1
of 1 -pages Page 0
Supplementary Sheet Ucense No.
Amendment No.
HD-31-025-01 37 Neutron Products, Inc.
22301 Ht. Ephraim Road P.O. Box 68 Dickerson, HD 208112 in accordance with NPI letters dated January 22 and 29, 1991 and drawing #120055 Rev. D c:noerning replacement of "decon area" doors, and Radiological Health Program (RHP) letter of February 1, 1991 Radioactive Material License Number HD-31-025-01 is amended as follows:
Condition 13 is amended to include: NPI letters of January 22 and 29, 1991 and RHP's letter dated February 1, 1991.
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT k
Ort)
Febnnry 7,1991 c
ADMINISTRATOR, R'ADIOLOGICAL HEALTH PROGRAM l
MDER Lt (supp)(11190)
,(
~~
//l6f YhEff/N$
f DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page 1 of I pages Supplementary Sheet hendment No.
36 Ucense No.
HD-31-025-01 Heutron Products, Inc.
22301 Mt. Ephraim Road P.O. Box 68 Dickerson, Maryland 208112 In cocordance with letters dated September 25 and December 20, 1990 Radioactive Material License Number HD-31-025 01 is amended as follows:
Crndition 13 is amended to includo NPI letters dated September 25, 1990 and December 20, 1990 concerning hot cell interlock and detector, and the Radiological Health Progam's lotters dated August 29, 1990 and January 9, 1991.
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT f
)
/tf fgA
- Dat, January 9, 1991 ADMINISTRATOR CENTER FOR RADIOLOGICAL H'RALTH MDER41 (supp.) (3188) r o-,-
dl6ff" l
YhAfdN$
RECEIVED DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR g
gg l
TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page 1 of 1 pages Supplementary Sheet Ucenne No.
HD-31-025-01 Amendment No.
35 Neutron Products, Inc.
22301 Ht. Ephraim Road l
P.00 Box 68 Dickorson, Maryland 208112 In occordance with letter with enclosure dated November 7,1990 Radioactive Material License Nurber MD-31-025-01 is amended as rollows:
Condition 13 is amended to include letter dated November 7,1990, stating additional conditions for radiation work permits for the hot cell, f
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT f
\\
dad November 26, 1990 f
L f ff _
ADMINISTRATOR, CENTER FOR RADIOLOGICAL HEALTH MDE:Rt1 (supp.)(3/68)
oksg'%
o#ey&m/
I DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATE: RIAL LICENSE i
Page 1 of 1.pages Supplementary Sheet Ucense No.
Amendment No.
Neutron Products, Inc.
22301 Mt. Ephraim Road P.O. Box 68 Dickerson, Maryland 20753 Purcuant to the Center for Radiological llealth's letter dated July 25, 1989, condition 13 of R:diosotive Material License Number HD-31025 01 is amended as follows:
Condition 13:
N utron Products is hereby authorized to perform operations, excluding the melting of bare cobalt, on an interim basis.
Permanent approval of operations will be restored pending submission to, and Department approval of all requirements of Condition 13.P.3 of Amendment Number 33.
k FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT
[]
[
Day Juiv 28. 1989 TDF/dpa ADMINISTRATOR, CENTdR FOR RADIOLOGICAL HEALTH MDEM1 Supp.) (3/98)
.p
(
)
f'-
Yk7l6f Y//ff /NW k
DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADICACTIVE MATERIAL LICENSE Page 1 of 8 pages Supplementary Sheet Ucense No. HD-31-025-01 Amendment No.
33 Neutron Products, Inc.
22301 Ht. Ephraim Road P.00 Box 68 Dickorson, Maryland 208112 Pursuant to Section A.7 of COMAR 26.12.01.01, condition 13 is hereby amended to add:
A. A gas Proportional Portal Honitor equivalent to the Eberline PCM-1b capable of detecting 2500 dpm at ono inch and 5000 dpm at three inches shall be utilized in a location approved by the Department. The monitor shall be used by all personnel who exit the Limited Access Area ("LAA").
They shall remain standing in the sensitive detection zone of the monitor for at least two full minutes.
Each person shall expose his/her back, front, right and left sides to the detectors for thirty seconds each. The monitor shall be maintained and used in accordance with the manufacturer's specifications at all times. At a minimum, this monitor shall be inspected by the manufacturer in accordance with the terms of its Service Contract and a copy of the service record shall be submitted to the Center for Radiological Health (CRH). The monitor shall be maintained and used in such a manner as to ensure its ability to accurately detect levels of radioactivity of 2500 dpm on the hands and 5000 dpm on the whole body.
The monitor must be fully operational and kept free from contamination at all times unless unforeseeable and unavoidable operational problems arise. The Department must be notified by telephone within one workday in the event that the portal monitor is not operational.
A contingency plan describing personnel monitoring procedures for use during downtime must be submitted to the Department for review and approval prior to resuming activities in the LAA. By June 12, 1989 the portal monitor must be located in the newly constructed access and egress area as identified in Attachment 7 to plans submitted by licensee on April 21, 1989.
B. Background radiation levels at the portal monitor shall not exceed 50 micro /R per hour unless otherwise authorized by the Department.
FOR THE MARYtAND DEPARTMENT OF THE ENVIRONMENT Date ADMINISTRATOR, CENTER FOR RADIOLOGICAL HEALTH MDEM.1 (supp.)(3/88)
[
k O
OkW6f C/kI/fftdtm/
DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page 2 of 8 pages Supplementary Sheet Amandment No.
33 Uconu No. MD-31-025-01 CONT'D C. A Ilealth Physics Consultant shall be retained by the licensee; This Consultant shall be retained subject to the approval of the Department concerning qualifications and shall perform the following functions
- 1. Perform an initial independent evaluation sufficient to satisfy the Department regarding the current radiological health program employed by licensee.
Thereafter and for a six-month period commencing upon hiring, submit monthly evaluations to the Department regarding the health physics / radiation safety status of the facility as it relater to ongoing and future operations under t.his licanse. Such evaluations shall includes a.
Contamination Control Procedures and Methods; b.
Respiratory Protection Program; Personnel Honitoring for internal and External Radiation Exposure; c.
d.
Radiological Effluent Monitoring and Control for Liquid and Particulate Releases From the Facility; Adequacy of Air Handling Systems in t!w Production Areas; e.
f.
Control and Identification of Radiation and liigh Radiation Areas, and Contaminated Equipment and Facilities; Radiological Waste llandling, Processing and Disposition (Storage and g.
Shipn.ent)I h.
Ilot Cell Decontamination Methods and Procedures;
- i. Personnel Training and Qualification; and
- j. Management Oversight and Control of Radiological Activities.
FOR THE MAHkLAND DEPARTMENT OF THE ENVIRONMENT Date ADMINISTRATOR CENTER FOR RADIOLOGICAL HEALTH MDERU (supp )(3Ita)
ckey V
&npfead DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR j
TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page 3 of 8 pages Supplementary Sheet Amendment No.
33 Ucense No. HD-31-025 01 CONT'D The initial evaluation of items a-j must be submitted to the Department prior t0 the commencement of any operations specified in Item P.
Evaluations under this paragraph may be tailored to the scope of operations allowed under Item P; e.g.,
the initial evaluation may, but need not, evaluate radiological health / radiation safety under operations involving bare cobalt-60 but such an evaluatiou must be received and approved by the Department prior to commencement of any actions involving bare cobalt-60. Subsequent evaluations must be submitted to the Department by the last day of each calendar month. Following this six-month period, the Department shall consider reducing the reporting period to a quarterly basis.
- 2. Ensure that the portal monitor is properly installed and maintained;
- 3. Oversee the construction of the portal monitor are1t as required in order to assure that background radiation levels do not exceed 50 micro /R per hour; li. For a six-month period commencing upon hiring, perform monthly evaluations of the portal monitoring area, the use of the portal monitor by employees, its functioning and the radiation safety training of employees, and submit monthly reports to the Department based upon such cvaluations.
These reports shall include the review of incidents of radioactive contamination above 22,000 dpr detected on personnel. Following this six-month period, the Department shall consider reducing the reporting period to a quarterly basis;
- 5. Oversee and participate in the design and construction of an enclosure to bo installed over the courtyard area ao as to provide an effective barrier against the release of radioactivity as described in Item M of this amendment; and
- 6. Conduct a thorough evaluati.on of the hot cell ventilation system currently employed by the licensee which shall be submitted to the Department.
Upon receipt of this evaluation, the Department shall classify deficiencies into two categories according to the severity of their potential harm to the environment:
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT Date ADMINISTRATOR, CENTER FOR RADIOLOGICAL HEALTH MDER11 (supo I(3/981
[
fikf hAfANfl DEPARTMENT OF THi! ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page,0 of 8 pages Supplementary Sheet 4
. Amendment No.
33 Ucense No. MD-31-025-01 CON't' D Deflaiencies whiuh must be remediated prior to reinitiation of hot cell a.
operations under this license; and
^
Deficiencies which must be corrected within a time period specified in a plan b.
submitted by licensee and approved by the Department.
The licenace shall impicment the Department's directives as defined in accordance with (a) and (b) above.
D. A full-time trained Health Physics technician or the equivalent in duly committed fractional time technicans shall be retained subject to the approval of the Department The licensee shall maintain a log which documents the concerning their qualifications.
work of the llealth Physics technician. He shall perform tho'following functions:
- 1. During working hours the technician shall ensure the proper use of the portal monitor, hand-held friskers and any other devices employed to detect levels of radioactivity present on persons or items which erit the LAA;
- 2. Ensure that all persons log in and out upon entering and exiting the LAA;
- 3. Ensure the proper use of hand-held friskorn by all persons who incur levels of contamination detected by the portal monitor;
- 4. Report immediately to the Radittion Safety Officer any contamination levels above 10,000 dpm which are detected by the pertal monitor, or if inoperat contingency monitoring.
dpm such incidents must be evaluated by the RSO and must be reported to the De,..rtment in monthly reports aubmitted to the Department by the Health Physics Consultant. Evaluations of such incidents of contamination, shall include the name The Dep'trtmen of the person contaminated and the degree of contamination detected.
shall be notified within two hours concerning all contaminations above 50,000 dpm which are detected by the portal monitor, or if inoperative, under contingency monitoring. During non-work hours, call (301) 243-8700 and ask the operator t~or "Rattiation Assistance".
FOR THE MARYLW'O DEPARTMENT OF THE ENVIRONMENT k
Date ADMINISTRATOR, CENTER FOR RADIOLOGICAL HEALTH MOER41 (supp.) (3I88)
-,.-y w.
DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page 5 of 8 pages Supplementary Sheet Uconse No. MD-31-025 01 Amendment No.
33 CONT'D
- 5. Document, for evaluation by the RSO all probable sources of radioactive contamination of employees who incur levels of contamination in excess of 2?,000 dpm.
- 5. Conduct radiation surveys within the entire facility la accordance with documented procedures set forth elsewhere in this license;
- 7. conduct water sampling of the main source pool, and waste water generated in the LAA in accordance with NPI's documented procedures set forth elsewhere in this licensel and
- 8. Conduct radiation surveys of soil and water contamination levels in accordance with a plan for t he surveillance of radioactive contamination in surface and ground water at the plant's boundary and within a one kilometer radius of the licensee's facility. The plan shall be submitted within 30 days of the effective date of this amendment and shall include a decontamination plan, a schedule for remedial action and contingencies for obtaining access to private dwellings and commercial property.
[
- 9. Conduct radiation surveys of all personnel, vehicles, equipment and personal belongings exiting the gate of the courtyard area in accordance with the limits specified in Section A of this amendment and the U.S. Department of Transportation Regulations.
E. Following any detection of contamination by the portal monitor, hand-held friskers capable of measuring levels of radioactivity as low as 500 dpm shall be used to detect the precise areas of contamination.
Upon discovery of a level of contamination at or above 500 dpm, contaminated individuals must be promptly decontaminated to a level as low as reasonably achievable and remonitored.
1 FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT Date ADMINISTRATOR, CENTER FOR RADIOLOGICAL HEALTH MDEFR1 (supp.) (3188)
()
e / & n te ty ?
alinjdma' DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECHETARIAT FOR TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page. 6 of B pages Supplementary Sheet Ucente No. MD-31-025 01 Amendment No-33 cor'r P. Within thirty (30) days of the effective date of this amendment a " clean room" shall be established in which radioactive contamination shall be limited to less than 500 2
dpm per 100 om smearable, removable contamination on any surface area. The clean room shall be located immediately inside the entrance door to the LAA and shall provide storage space for all street clothing and equipment which should not be worn or transported into other areas of the LAA.
O. Any cloth., worn outside the LAA shall not be worn in the LAA except in the clean room.
Conversely, any clothing worn in other areas of the LAA shall not be worn outs'.de the area.
Such clothing may be worn in the clean :oom if a thorough frisking of a person detects no contamination in excess of 2500 dpm on the hands and 5000 dpm on the whole body.
- 11. Within thirty (30) days of the effective date of this amendment, the licensee shall establish and impicment a detailed Radiatior. Safety Training Program as approved by the Department.
At a minimum, this Program shall provide, on a quarterly basis, training sessions provided by the 11ealth Physics Consultant to all employees who, under any circumstances, may have access to the LAA. Attendance at such training sessions shall be mandatory and documented.
I. Within thirty (30) days of the effective date of this amendment, the licensee shall submit for approval by the Department a random inspection plan of the LAA and the unrestricted areas to be conducted on a monthly basis and implemented by the liadiation Safety Officer. Once approved by the Department, said plan shall be implemented immediately.
J. The compaction of radioactive waste prior to storage or disposal is prohibited unless the Department approves of a plan submitted by the licensee for conducting this activity in a safe manner.
K= By June 30, 1989 the licensee shall submit to the Department for approval a comprehensive plan for dispost.1 of all low level radioactive waste.
Upon approval by the Department, this plan shall be implemented.
FOR THE MARY 8.AND DEPARTMENT OF THE ENVIRONMENT Date ADMINISTRATOR CENTER FOR RADIOLOGICAL HEALTH MDER L1 (supp )(3/08)
/
W
'O 4,
Ek
?
A IN DF.PARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR T0XICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH iiADIOACTIVE MATERIAL LICENSE Page 7 of A _pages Supplementary Sheet Ucense No.
HD-31-025-01
^*'ad**"' N -
33
_ CONT'D L. Thermoluminescent dosimeters (TLDs) or film badges shall be placed at the fa:ility's boundaries.
Such dosimeters shall be affixed to existing boundary structures (i.e.,
a wall or fence) and shall be replaced on a monthly basis.
Dosimeters shall be placed at a maximum of one hundred feet apart along each boundary structure. The boundary radiation exposure limit shall not exceed 500 millirem per year.
H. In order to reduce the potential for release of radioactivity and to maintain low radioactive background levels outside the courtyard area, an enclosure shall be installed over that portion of the courtyard required to protect against the release of radioactivity.
A plan to install said enclosure shall be submitted to the Department for approval within forty-five (145) days of the effective date of this amendment, excepting the period of time in which the County is considering the plan.
The enclosure shall be installed within one hundred fifty (150) days of approval by the County and the Department.
Its construction shall be overseen by the Health Physicist Consultant as described in Item C.
N. Within thirty (30) days of the effective date of this amendment, the licensee shall submit a plan for ovaluation and remediation of ground areas surrounding the facility.
This plan shall be approved by the llealth Physicist Consultant. Upon approval of the plan by the Department, said plan shall be implemented by the licensee. The criteria for acceptability of cobalt-60 contamination of ground areau are:
- 1. The gamma exposure at one (1) meter above the ground surface shall not exceed _10, microR/hr above background for an area greater than 30 ft x 30 ft and shall not exceed 20 microR/hr above background for any discrete area (i.e. less than 30 ft x 0
30 ft).
- 2. The concentration limit for subsurface cobalt-60 contamination is 8 picoeuries per gram above background for an equivalent area of 30 ft x 30 ft.
~
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT Date ADMINISTRATOR, CENTER FOR RADIOLOGICAL HEALTH t
MOER L1 (supp)(3/B8)
YllMf YA!Vb/kl
)
DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page 8 of 8 pages Supplementary Sheet Licenu No.
HD-31-025-01 Amendment No.
33 CONT'D Prior to approval of this plan, all soil exhibiting levels of radioactivity in excess of the above attributable to NPI, wherever found, ahall be removed and properly stored / disposed of by the licensee. The Department shall be furnished with documentation of the discovary, survey dates and disposition of such radioactivt material found off-site on a monthly basis.
O. Within thirty (30) days of the effective date of this Amendment, a floor radiation monitor of a type approved by the Department shall be used on a weekly basis to detect surface levels of radioactive contamhation on all surfaces within the facility outside of the LAA. Licenseo shall maintain records regarding the use of this monitor.
P. 1. Licensee may engage in the receipt of singly encapsulated cobalt-60 immediately.
O. Licensee any engage in those activities requiring the use, handling, shipment and transfer of doubly encapsulated cobalt-60 as soon as the Department has evaluated and approved of the licensee's accomplishment of conditions,A, C, D, 0, J and L.
4
- 3. Activity involving bare cobalt-60 or singly encapsulated cobalt-60 components or the alteration of doubly encapsulated oobait-60 sources, particularly the removal of the outer encapsulation will be permitted as soon as conditions B, E, F,11, I, K
M, N and 0 are evaluated and their implementation approved by the Department.
- 4. The evaluations by the Department described herein shall be completed within five (5) working days of receipt of a plan or the data required or notification by the licensee that a condition has been satisfied.
The Department shall promptly notify the licensee of its approval or disapproval.
Q. Facility modifications to the access and egress area as identified in Attachment 7 to plans submitted by licensee on April 21, 1989 shall be completed by June 12, 1989 FOR THE MA YLAND DEPARTMENT OF THE ENVIRONMENT DaCD May 23. 1989
,Roland G. Flet ter
)(ADMINISTRATOR, CENTER FOR RADIOLOGICAL HEALTH MotRu (wpp )(3184)
W&ns'rf a$Nnf/E'nd' 1
DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS, ENVIRONI.tENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICAL HEALTH RADIOACTIVE MATERIAL LICENSE Page 1 of I pages Supplementary Sheet Uoense No.
HD-31-025 01 Amendment No.
32 Nu tron Products, Inc.
I 22301 Mt. Ephraim Road P.O. Box 68 Dickerson, Maryland 20 8112 In accordance with our Order dated March 3,1989 and the letter of Bethlehem Steel Ccrporation dated April 10, 1989 Radioactive Material License Number HD-31-025-01 is amended cs follows:
Itc~s 91, through 9M of the license are amended to add:
F. The thirty sources of Cobalt-60 singly encapsulated for Bethlehem Steel Corporation intended for installation in the replacement refractory lining in a Bethlehem, Pennsylvania plant may be shipped from the Dickerson facility with the contamination level checked by Anthony LaMastra as stated in K.M. Messler's letter of April 10, 1989.
FOR THE MARYLAND DEPARTMENT OF THE ENVIRONMF.NT Date -
April 12. 1989 ADMINISTRATOR. CENTER FOR RADIOLOGICAL HEALTH MDER4.1 (supp)(31ts)
(.
dlMf G/IYAf/fdN$
DEPARTMENT OF THE ENVIRONMENT ASSISTANT SECRETARIAT FOR TOXICS, ENVIRONMENTAL SCIENCE AND HEALTH CENTER FOR RADIOLOGICT ^. HEALTH RADIGACTIVE MATERIAL LICENSE Page I of 1 pages Supplementary Sbset Ucense No.
MD-31-025-01 Amendment No.
30 N:utron Products, Inc.
22301 Mt. Ephraim Road Dickerson, Maryland 20842 In ccoor. dance with our letter and order dated March 3,1989 Padioactive Material License Humber MD-31-025-01 is amended as follows:
Itc:s 9A throt.wh 9H of the license are amended to read:
A. All radioisotopes, including cobalt-60, cesium-137, radium-226 or atomic numbers 3-92 will be for possession and storage only.
B. All phases of cobtit-60 source production, calibration, and distribution are strictly prohibited.
C. All sources of any radioisotope currently located in the limited access area (LAA) may not be used or removed from that site.
D. Radiation sources may not be moved to or from irradiators by any means.
FOR THE MARYLAND DEPARTMENT OF THE 2NVIRONMENT Dat]
RVeh 3,1909
_ O, I
r; ADMINISTRATOR, CENTER FOR RAOlOLOGICAL HEALTH CRP/ec Y p '//, o A
~
MoER-U Dupp.)(3/68)
84 %
l' C$mVg/ D ONInydw/
Jid 2 6 E D N M g _pf _M_lE____ g4 5N DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE ON OW Page l of l_pages Supplementary Sheet Uconte No.
Amendment No.
g Neutron Products, Inc.
22301 Mt. Ephralm Road P.O. Box 69 Dickerson, Maryland 20842 In accordance dth Section A.7 of COMAR 10.14.02.01 Radioactive Material License Number MD-31-025-01 in amenJed as follows:
To Add Condition 22:
- 22. Heutron Pro 6ucts, Inc, may receive Cobalt-60:
- a. from a vendor who has produced Cobalt-60 in a reactor; or
- b. from a teletherapy unit or irradiator when Neutron Products, Inc. installs a replacement source.
To Add, Condition 23:
- 23. Neutron Products, Inc, may not receive Cobalt-60:
a that is contaminated with other isotopes; or b as any material contaminated with Cobalt-60; or
- c. as a sealed source which is not received in exchange for a replacement source unless prior approval has been granted by the Center for Radiological Health.
Such arior approval ray be granted only after a thorough review of a specific proposal t1at describes the source of cobalt, the total activity and quantity involved, other isotopes involved, the proposed use and the potential market of any product thus produced and the plan for disposal of any waste generated.
4 FVR nlE MIGYlAND DEPARTMDR OF THE oei.
January 21, 1988
~
ACEINISTRA'10R, CDRER FOR BADIOLOGICAL CRF/ame
}{EALDI
.- ~n.
1
C/M/cff Y
cyhlnp/ joy /
DEC 3 \\ f981 t
nem ann or me ramr i
gmn 7 -""" - g - = ; -- '
sot wyggman DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE p.ee 1.L L eeece Supplementary Sheet Uc:nse No.
/Wendment No.
HD-31-0k5-01 29 Weutron Products, Inc.
22301 Mt. Ephraim Road P.O. Box 68 Dickerson, Maryland 20842 In accordance with Section A.7 hr COMAR 10.14.02.01 Radioactive Material License Number HD-31-025 01 is amended as follows:
To Add Conditien 22:
L
- 22. Neutron Products, Inc. may receive Cobalt. 60
- a. from a vendor who has produced Cobalt-60 in a reactor; or i
- b. from a teletherapy unit or irradiator when Neutron Products, Inc. installs a replacement source.
To Add Condition 23:
- 23. Woutron Products, Inc. m.:.y not receive Cobalt-60
- a. that is contained with other isotopest or
- b. as any material contaminated with Cobalt-60) or
- c. as a sealed source which is not received in exchange for a replacement source unless prior approval has been granted by the Center for Radiological Health. Such prior apprt, val may be granter only after a thorou6h review of a specifio proposal that describes the source of cobalt, the tota? activity and quantity involved, other isotopes involved, the proposed use and the potential market of any product thus produced and the plan for disposal of any want e generated, i
EDR THE MARYI1WD DEPARTMEifl' OF THE
- 1ENT o t3 -
Decenber 29, 1987 ADMINISTRA'IOR, CENTER FOR RADIOIIGICAL CRF/an: '
HEALTH c==ma ise maeu
..._.,_.._._..-_,2
g, y/4,,g SEP 2 51985
'"En"c's"or Ew"EEu$!AY'PT[da"AI$'"'
xs was a m m a n
- x i
xsammex pot wes,tgognert DIVISloN OF RADIATION CONTROL RADICACTIVE MATERIAL LICENSE Page _ Lot 1 pegee Supplementary Sheet License No.
Amendment No.
MD-31-025-01 28 NEUTRON PRODUCTS, INC.
22301 Mt. Ephraim Road P.O. Box 68 Dickerson, Maryland 20842 In accordance with letter dated September 16, 1985 Radioactive Material License Number MD-31 -025-01 is amended as follows:
Condition Q in amended to add:
Letters of July 30, 1985 and August 2, 1985 Condition 21 is amended to read
- 21. R:dioactive material authorized in Item 7. A.(2) shall be received only from the Commonwealth Edison Dresden nuclear power plants, unita I and II, located in Morris, Illinois: Niagara Mohawk Power Corporation, Nine Mile Point Unit I; and Philadelphia Electric Company, Peach Bottom, Unit 2.
For the Maryland Department of Health O
nd M tal Hygiene 1
I 1
Date __ September _lae 1995 a.
1.
aammi.ir.,
m... proer DHnet **>4 thep)(t43
.,.c.
. ~.. -
,,_,_a.
n s e a
4**
' " " ' " ~
g "sT#c'f55,f3!!s0?#'4Me%"
n gggpn DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE raee_L_of 1 aseos Supplementary Sheet U: nseNo.
Amendment No.
MD-31-025-01 27 NEUTRON PRODUCTS, INC.
22301 Hount Ephraim Road
.P.O. Box 68 Dickerson, Maryland 20842 In accordance with latter dated June 6,1985, Radioactive Material License Number HD-31-025-01 is amended as follows:
_ Condition-11 is amended to read:
- 11. A. The radiatior protection program shall be under the supervision of Wayne Costley.
B. Radioactive material shall be used by, or under the supervision of Wayne Costley, J. A. Ransohoff, H.H. Turkanis, D.L. Repp, J.R. Demory, Jeffery W. Corun, and/or Carmine Smedira.
condition 13,is amended to add:
Letter dated June 26, 1985.
For the Maryland Department of Health 0
np ental Hygiene o.t._ _ July _ 1.1985 W
u..,.i.,.
RDC/ame o m ae4 me. m a
CO#i'{
W8Inf4/w/
JUL - 6 985 KatessugleeU6EEM oFNCE mi.N.r g gen F V W
W x
DIVISION OF RADIATION CONTROL l
RADIDACTIVE MATERIAL LICENSE page 1 ot2_e e.
Supplementary Cheet l
1.lcente No.
Amendment No.
NEUTRON PRODUCTS, INC.
22301 Mount Ephraim Road P.O. Box 68 Dickerson, Maryland 208112 In cc:ordance with letter dated June 7,1985 Radioactive Haterial License Number HD-31-425-01 is amended as follows:
6A. 7A 8A and 9A are amended to read 6
Wadioactive material
- 7. Chemical and/or
- 8. Maximum amount of (element and mano number) physical form radioactivity which licensee may possess at any one time A.
Cobalt-60, and A. (1) Singly encapsulated A. 3,000,000 Curies.
incidental activation sources;or, products in stainless (2) Stellite bearings and steel, tircaloy, aluminum axle rods mounted in inconel, or stellite stainless steel corners sheared from the top end of BWR control rod assemblies.
- 9. Authorized use A. (1) Hanufacture of special form Cobalt-60 sealed sources for distribution to authorized recipients. Sources distributed shall meet the applicable current ANSI standard.
(2) Remval of encapsulation and melting of unsealed Cobalt-60 to fabricate solid slugs containing up to 12,000 Curies of Cobalt-60 per slug.
For the Maryland Department of Health and Mental Hygiene
. Dat3 Administe. tor, Community Health Programs DHM*43D4 bep)(143
~
~ ~ ~'
g -[
~
m q :g g g y = r
-,-u
\\
DIVISION OF RADIATION CONTROL RADIDACTIVE MATERIAL LICENSE Page I of I negos Supplementary Sheet Uc;nse No.
Amendment No.
MD-31-025-01 25 Houtron Products, Inc.
22301 Mount Ephraim Road P.*0. Box 68 Dickerson, Maryland 20842 In accordance with letter dated July 6,1984, Radioactive Material License Number M D-31-025-01 is amended as follows:
To Adds
- 6. Radioactive Material
- 7. Chemical and/or
- 8. Maximum amount of radioactivity (element and mass number) physical form which Ilcensee may possess at any one time N. Col; alt-60 N. Sealed source N. 2,000 curies in AECL Gamma cell 220
- 9. Authorized use N. To possess and unload in NPI hot cell at Dickerson.
Condition 13 is amended to add:
letter with attachments dated July 24, 1984.
%rtheM.
I d m t f Health
,o ent g e i-M.
Dat3 July 30.1984
^*"*""'* ~ """"" W CRF/ka kb m., a sa n n,ea
..< n t.
p 4 twa chwef o & pend q.gpy
"$Nc'e"ofEw"vWuSE$'E$n"AI$'"'
miegtggper DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page 1 of 1 pages Supplementary sheet ue:nse No.
^**" ' ' " '
M D-31-025-01 24 Nautron Products, Inc.
22301 Mount Ephraim Road P.O. Box 68 Dickerson, Maryland 20842 In cecordance with letter dated June 20, 1984 end received June 22, 1984, Radioactive Material License Number MD-31-025-01 is amended as follows:
To Adds
- 6. Radioactive material
- 7. Chemical and/or
- 8. Maximum amount of radioactivity (element and mass number) physical form which licensee may possess at any one time M. Cesium-137 M. Scaled source in M. 475 curies U.S. Nuclear irradiator Model GR 8A
- 9. Authorized use M. To possess and unload in NP1 hot cell or " bomber" and dispose of cesium source as radioactive waste.
For the Maryland Department of Health q
nd M I H gi ne I
- cat, July 30.1984 d V1.
CRF/kagQ DHW Jor54 thee I(1a5
HNlf' Yh/? (/N(/
m====e
"'** 'anwm DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page I cf 1 nages Supplementary Sheet Ucense No, Amendment No.
MD-31-025-01 23 Neutron Products, Inc.
22301 Mount Ephraim Road P.O. Box 68 Dickerson, Maryland 20842 In eccordance with letter dated June 20, 1984 and received June 25. 1984, Radioactive Meterial License Number MD-31-025-01 is amended as follows:
Items 91, 9J. 9K are amended to read:
The radioactive material listed in Items 61, 6J, and 6K may be removed from their respective irradiators, work only to be done in the NPI hot cell.
a e
?
F partment of Health T or the Maryland ys N*
o,i, July 30.1984-CRFika (d%
I o~,.m a.. <, o
- m. _.,
a-
ChHMg/
Ir.//hrh)y/
p au.gggy "M'#c'e"inu"Mi&E?e'r"se!3"
"' ".Tn'*uiTE'*"
DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Pege I of 1 peges Supplementary Sheet Ucense No.
Amendment No.
M D-31-025-01 22 Noutron Products, Inc.
22301 Mount Ephraim Road P.O. Box 68 Dickerson. Maryland 20842 In cc.cordance with letter dated June 10, 1982 Radioactive Material License Number MD-31-025-01 is amended as follows:
To Adds
- 6. Radioactive material
- 7. Chemical and/or
- 8. Maximum amount of radioactivity (element and mass number) physical form which licensee may possess at any one time L. Cobalt-60 L. Scaled source L. 250 curies in Rad-o-cell irradiator
- 9. Authorized use L. To possess and unload source from irradiator in N' I hot cell.
P F
artment of Health 3 or the Maryland 3apo
. ~,s..
)
Date
._ July 30,-1984
^*=* * = c===i==
,b.
CRF/ka )fD
)
D W NXS$ Spp,j{ggg
//N)ff ff/f (////
xensonn g g soccx U'NctorEw"v$"uSEAY'e"En"A$"'
"D
"" wa"as'*"
DIVISION OF RADIATION CONTROL RADIDACTIVE MATERIAL LICENSE Page 1 of 1 pages Supplementary Sheet Uc:nse No.
Amendment No.
MD-31-025-01 21 N.utron Products, Inc.
- 22301 Mt. Ephraim Road P.O. Box 68 Dickerson, Maryland 20042 In cecordance with letter dated March 16, 1984, Radioactive Material Licenzo Numbe; MD-31-025-01 is amended as follows
condition 17(f)(4) is amended to read:
The authorization contained herein is not effective after April 15, 1984.
i 4
F the Maryland Department of Health an$ M ntalI g eng 4, f(g 1
March 30, 1984 g,,,
%"'"*'* **"'"'"" ** **(
car /ka l
fl$
Y // f/Hff o==== -
BALTIMORE 21201 DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page I of I pages Supplementary Sheet Uc:nse No.
MO-31-025-01 Amendment No.
gg Neulton Products, Inc.
22301 Mt. Ephraim Road P.O. Box 68 Olckerson, Maryland 20842 in accordance with letter dated January 19, 1984, Radioactive Material Licerue Number MO-31-025-01 ts amended as f ottouts:
condition 17(fI(4) Ls amended to read The authoriza<tlon contabted herein is not ef fective af ter March 15, 1084.
t For the Maryland Department of Health anq Mental
'ene January 31, 1984 A i
. L Ak o,,~,
cneika pg, "V"'"*"*h)
I
NOV 5 $?c.2 w-Chenet 8L LAa da., Se t-0 FCE F N NMEN AL M
seu==
wiw gegy
- t. 5 DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page 1 of L-pesos Supplementary Sheet Ucense No.
Amendrr ant No.
Neathon Products, Inc.
22301 Mt. Ephraim Road P.O. Box 68 Dickerson, Martland 20842 j
in accatdance with Letter dated October 24, 1983, Radioactive Material License Number MD-31-025-01 is amended as follosest Condition 13 is amended to add letter dated October 24, 1983.
gFor the Maryland D artment of Health i )
S afd Mei tal y 'e 1
1 1
l Data October 28, 1983 N'b umim.ir.io,.commouiys. m DHwMana Apo4(143
"~
Al8 Y lf0 f/ //
AUG 2 4 C37 Adclo Wilzack, R.N,M.S.
DEPARTMENT OF HEALTH AND MENTAL HYGIENE
""nU5,m oFRCEo EytggNE to"# S^
E sunwont rimi DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Pege 1 of 1 pages jupplementary Sheet Uc nse No.
Amendment No, MD-31-025-01 18-N;utron Products, Inc.
22301 Mt. Ephraim Road
~
P.O. Box 68 Dick;rson, Maryland 20753 In accordance with letter dated August 10, 1983, Radioactive Material License Number MD-31-025-01 is amended as follows:
condition 17 (f) (4) as added by amendment 15 is amended to read:
The authorization centained herein is not offective after January 15, 1984.
H 1
For the Ma and rpe of Health Me al y fen August 17, 1983 n
c,,,,, go
- -i n o
- /
AUG 9 1983 Adalo Wil:ack, R.H., M.S.
OEPARTMENT OF HEALTH AND MENTAL HYGIENE OFFICE oF EgRo JQue R
ENTA RAMS sanuons staos DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE 1
1 Page of nages Supplemontary Sheet Uc;nse No.
Arnendment No.
MD-31-025-01 17 Ncutron Products, Inc.
2231 Mt. Ephraim Road P.O. Box 68 Dickerson, Maryland 20753 In cccordance with letter dated June 13, 1983, Radioactive Material,Lic3nse Number MD-31-025-01 is amnded as follows:
To Adds
- 6. Radioactive material
- 7. Chemical and/or
- 8. Ma':imum amount of radioactivity (element and mass number) physical form which licensee may possess at any one time I. Cobalt-60 I. Sealed source I. Total possession (American Nuclear 170 curies i205)
J. Cobalt-60 J. Scaled source J. Total possession (American Nuclear 35 curies 6206)
K. Cobalt-60 K. Sealed source K. Total possession (Radiation 220 curies racilities IS3)
- 9. Authorized use I. Possession and storage only in American Nuclear irradiator model 120M.
J. Possession and storage only in American Nuclear irradiator model 10M.
K. Possession and storage only in Radiation Facilities Model Rad-O-Cell.
For the Maryland Department of Health and Mental Hygiene Dat)
August 1.
19fl3 CRF/ka h
~ ~, i, o
l O
[
/
3 0 ;, -
'"o?8cY$Nu"vE*uSEaY'5'o'dUi$'"'
="~;ralwm DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page 1 of 1 pages Supplementary Sheet Uc;nse No, Amendment No.
MD-31-025-01 16 N utron Products, Inc.
22301 Mt. Ephraim Road P.O. Box 68 Dickorson, Maryland 20753 In accordance with Division of Radiation Control's letter dated June 3,1983 and Neutron Products, Inc letter dated July 21, 1983, Radioactive Material License Number Mb-31-u25-01 is cmended as follows:
To Add cone 11 tion 10:
- 18. Any and all authorization previously granted under Radioactive Material License MD-31-025-01 for the poscession, storage, use, and handling of radioactive material in the irradiator designated and known as "Dickerson I," which includes the water storage pool therein, is completely deleted and shall no longer apply.
i of the Ma nd Department of Health j
ad eftta%ygiene I
J July 26, 1983
{
~
Aenea+ iretor,commenyOa prog TRB /ka Q
.--...t
- EFUCE$F$NY rww st secur, sc.o.
O W
A S
- sauer, miwgreeyper DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page I of 2 pages Supplernentary Sheet Uc:nse No, MQ-31-025-0; Amendment No.
- 3
)
Neutton Products, Inc.
21301 Mt. Eplvtaim Road P.O. Box 68 Dickerson, Maryland 20153 In accordance with letter dated February 4,1983, Radioactive Materlat License Number MD-31-025-01 is amended as fottotest To Add Condition 17s
- 17. The licensee is auuorized to perform the work at the Dickerson facility on an AECL Gammacett 220 Unit described in letter and attachments dated Februart) 4,1983 as fottows (a) Transport radioactive materiat in irradiator to de Licen6ee's facilities at pickerson, Maryland; (b) Perform a powered opeAational check of the tutit at Dickerson; (c) QL6 assemble and unload the Ltradiator at Dickerson; (d) Reassemble and toad d e irradiator told new source fabricated at de Licen6ee's facitlty; (e) Perfo.tm second powered operational check of de unit at Dickerson; (f) Transpatt radioactive ma.tcrial in loaded irradia. tar to castcrre.r's addres4; ptovided unt:
(!) Radioactive matcri44 described in Step 6 (a)(b)(c)(d)(c)(f) L6 used by, or under the ditect supervision and in de physical phesence c6 Carmine Smedira.
(2) Prior to the initiation of the activities described in Steps (a) thru (f) above the licensee shalt notifys Richard J. Brisson, Divi 4Lon o( Radiation Control, Ma.ryland State Department of Hea.lth and Mental Kggiene, 201 W.
Preston Street, Sttlimore, Maryland 21201, 383-2744. Note es shalt be sufficient to permit inspection of any and all such activities.
.(3) A sunrury repart L6 submitted on the completion of the project.
For the Maryland Department of Health and Mental Hygiene Data wrewe.w commwmy H. eta =resroma oHue 189p9)(144
I
.0E4 E$
b ^
Rfr/////
IfNff
(
i Chertos R. Sect, Jr 64.0-O CE F NY M
A PR sace.w.
soi g ega g g ateT DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page_ f of f negos Supplementary Sheet Ucense No.
pp.3y.gg$ 9y.
Amendment No.
y$
(4) The authorization contained herein is not ef fcctive afteA
'SeptenbeA 1,1983.
Ccndition 13 Ls amended to add:
- 13. LetteA dated Februny 4,1933 signed by Carmine Smedita, with attachments.
For tQe Maryland Department of Health andQntiHyf g
I March 9, ?983 AM o,,,
,cy, y, a,_m.__,,_-_.0
. m. w nia.
Y DEPARTMENT OF HEALTH AND MENTAL HYGlENE DMSION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE 1
1 Page of pages Supplementary Sheet License No, MD-31-025-01 Amendment No. g Neutron Producta, Inc.
Po0. Box 95 Dickerson, Maryland 20753 In accordance with letter dated May 26, 1978, Radioactive Material License Number MD-31-025-01 is amended as follows:
Item 7A is amended to read 7A Encapsulated sources manufactured by NPI, and encapsulated sources produced by other authorized manufacturers.
iA. C
$ +w
/
For the Maryland State Department of Health and ntal Hygiene une $3 1978 g
CCtgegg Date Divison of fladiation Control oHMM-300-6 (Suco.)
(
Ah f
DEPAHTMENT OF HEALTH AND MENTAL HYGIENE OMSiON OF RADIATION CONTROL
,)% N RADIOACTIVE MATERIAL LICENSE Page 1 of,,,,2, pages Supplementary Sheet License No.
Amendment No.
Nwtron Products, Incorporated P.O. Box 95 Dickerson, Maryland 20753 In cecordance with letters dated August 2, 1977, October 12, 1977, October 18, 1977, Radioactive Material License Number MD-31-025 01 is amended as follows:
To Add
- 6. P.adioactive matarial
- 7. Chemical and/or
- 8. Maximum amount of radio-(elemont and mass number) physical for=
activity which licensee may possess at any one time H. Any radioactive material H. Encapsulated thermal H. No more than 10 millieu-ctomic numbers 3 to 92 as and flux monitors ries each radionuclide.
activation products Total inventory 100 mil 11 curies 9.
Authorized Usa H. ?cr removal of conpenents from surveillance capsules and distribution to authcrized licensees For the Maryland Stats Department of Health and Mental Hygiene Date _ January 10, 1973
[t' (h t LMdeq(2-s Divison of Radiation Control "osun soo a tsupo.)
{
\\
/
r
}
.DEfARTMENT OF HEALTH AND MENTAL HYGlCNE OlVISION OF RADIATION CONTROL RADIDACTIVE MATERIAL LICENSE Page 2._ of 2 pages Supplernentary Sheet License No. ED-31-025-01 Amendw,t No.13 To add condition 16 A, B, C 7
16A.
Full scale molting of cobalt-60 in the hot cell shall not be;;in until the hot cell has been completely lined with stainless steel as described in letter datnd October 13, 1977 B.
A report summarizing the details and findinEs of the second phase of the melting prograr shall be furnished to the Department one month prior to the start of full scale melting.
C.
Sealed sources as flux or ter.perature nonitors shall not be opened.
1' Condition 13 is amended to add:
- 13. Letters dated August 2,1977, October 12, 1977, October 18, 1977.
Item 9 H is anended to add:
(b) fabricate, including moltir.g,of solid slugs containing up to 12,000 curies of cobalt-60 per slug.
^
For the Ma yland State Departrnent of Health q
and Mental giene Date }ar.utry 10, 1970
(
[QyW Olvison of Radiation Control
>HMH 300's (Supe I
-=
l DEPARTMENT OF HEALTH AND MENTAL HYGIENE
{
DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page of.2 pages Supplementary Sheet Ucense No. MD-31-025-01 Amendment No. 12 Neutron Products, Inc.
Dickerson, Maryland 20753 In accordance with letters dated /ebruary 16, 1977 and February 17, 1977, Radioactive Material License Number HD-31-025-01 is amended as follows:
Change Item 8A to read 3,000,000 C1 Item 9A is amended to readt 9A.
"To be processed, stored, and used in the main storage pool, canal, and hot cell for purposes of processing and redistribution to auth-orized recipients. Secondary encapsulation in tne hot coll, and irradiation of various materials in the storage pool, the package goods batch irradiator, and the hot cell are also authorized.
The hot cell may be used to: (1) open sealed sources containing solid slugs, pellets, clad wire coils, 'solidc' or ' hollows;'
(2) cut the coils, ' solids' or ' hollows' into small segments; and (3) reassemble and enrapsulate the sepents and/or pellets."
Condition 13 is amended to read 13 Except as specifically provided by thl s license, the licensee shall poscep and use radioactive material authorized by this licenoe in accordance with statements, representations, and procedtves contained in application dated November 27, 1967, submitted to the US NRC and amendments thereto submitted and approved by the US 1RC prior to Decem'oer 31,1970 %d in letters dated 3/23/71,10/6/71,11/h/71,11/12/71, 5/10/72, 6/10/72,11/29/72,1/1h/7h, 6/6/7h, 10/20/75, 2/16/77, and 2/17/77.
I Fce the Maryland State Department of Health and M. ital Hygiene Date February 17, 1977 Divison of Radiation Control DHMH-300 6 (Supo.)
.s t
DEPARTMENT OF HEALTH AND MENTAL HYGIENE OlvitlON OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE 2
Page of-2 99,,
Supplementary Sheet license No.
Amendment No.
CONDITIONS CONIT.
Condition lb of Amendmont 1016 amended to read:
lb. Pursuant to Section C.302 of the Maryland Regulations Governing Radiation f^rotection (10.03 10) Neutron Products, Inc., is authorized to dispose of waste water from the Dickerson facility by release to the sanitary sewerage system of the Washington Suburban Sanitary Commission as described in lettor dated August 6,197h.
The concentra-tion of radioactivity in the waste water shall not exceed 2 x 104uci per milliliter or one (1) curie per year. A copy of the current Washington Suburban Sanitary Comission c.uthorization for such disposal, shall be furnished to the Department.
Condition lh of Amendmont No.11 is deleted.
Condition No. 15 is addedt
- 15. The licensee shall operate heat transfer systems in the main storage 1
pool and transfer canal to maintain water temperatures at 950F, or below, under normal operating conditions.
I NW 4
i p
For the Maryland State Departmenbf Health and Mental Hygiene Date February 17, 1977 de(f P (k/gvde d f
Divison of Radiation Control onus soo-4 (suco.
l
l
/
f J
~
DEPARTMENT OF HEALTH AND MENTAL HYGIENE DMSION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE 1
of 1 Page ws Supplementary Cheet Lice'nte rio.
Amendrnent No.
l.:D-31-025-Ol 11 CCr.IOTE3 CCFY Heutron Products, Inc.
P.C. Box 95 Dickerson, Faryhnd 20753 In response to letter dated December 15, 1975, signed by harvin E. Turkanis, License Humber !!D-31-025-01 is amended as follows:
Item 9.A. is anonded to read 9..\\. To be possessed, stored, and used in the canal, and hot cell for purposes of processing and redistribution to authorized recipients.
Secondary encapsulations in the hot cell, and irradiation of various materials in the package gcods batch irradiator and the hot cell are also authorized. The hot cell may also be used to (1) open sealed sources containing pullets, clad wire coils, " solids" or " hollows";
(2) cut the coils, " solids" or "hollcws" into small segr.ents; and (3) reassenble and encapsulate the segments and/or pollets.
- endition 13 is amended to add
- 13. Letter dated July 31,1975 with attachments, and letter dated Decenber 15,197o.
Condition 1h is added:
lb. Licensed material may be used only as specified in $ tems 9A through 90 of this license e:: cept that t.nder this condition the licensee is authorized to storo and calibrate sealed sources only in the main storage pool.
Q : -. J&
For the Maryland State Department ofhalth and Mental Hygiene D:te February 17, 1977
/
V[
(
TOM 1 t >
Divison of fladiation Control DHMM 300-4 (Suce.)
'+
The attached corrected copy of arendment 11 to License 1:D-31-025-01 supersedes the original issue of this anondment which was erroneously issued as anendment 10 cn Janc.ary 3,1977.
m vr--
h' Y
DEPARTMENT OF HEALTH AND MENTAL HYGIENE DMSION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE 1
1 Page of pages Supplementary Sheet Ucenw No MD-31-025-01 Amendment No,10 Neutron Products, Inc.
P.O. Box 95 Dickerson, Maryland 20753 In response to letter dated December 15,1976, signed by Marvin M. Turkanis, License Number MD-31-025-01 is amended as follows:
Item 9.A. is amended to read 9.A. To be possessed, stored, and used in the canal, and hot cell for purposes of processing and redistribution to authorized recipients.
Secondary encapsulations in the hot cell, and irradiation of various materials in the package goods batch irradiator and the hot cell are also authorized. The hot cell may also be used to (1) open sealed sources containing pellets, clad wire coils, " solids" or " hollows";
- 2) cut the coils, " solids" or hollois" into small segments; and
- 3) reassemble and encapsulate the segments and/or pellets.
Condition 13 is amended to add 13 letter dated July 31,1975 with attachments, and letter dated December 15, 1976.
Condition 114 is added:
1 14 Licensed naterial may be used only as specified in items 9A through 90 of this license except that under this condition the licensee is authorized to store and calibrate sealed sources only in the main storage pool.
0 M S
( m a () a u1P/77 For the Maryland State Department of ealth and Mental ygiene Date January 3, 1977
[ gk P
( 2' [ g % c, d DMson of Radiation Control owue. soo a tsvoo.1
.lkl,'21lgy DEPARTMENT OF HEALTH AND MENTAL HYGIENE DIVISION OF RADIA110N CONTROL RADIOACTIVE MATERIAL LICENSE 1
1 Page M
pop Supplementary Sheet Uanse No, MD 31-025-01 Amendment No. 10 N;utron Products P. O. Box 65 Dickerson, Maryland 20753 In accordance with letter dated December h,1975, Radioactive Material License MD 31-025-01 is amended as fonows:
To Add Condition lhe lh. Pursuant to Section C.302 of the Maryland Regulations Governing Radiation Protection (10.03 10) Neutron Products, Inc., is authorized to dispose of waste water from the Dickerson facility by release to the sanitary sewemge system of the Washingten Suburban Sanitary Commission as described in letter dated August 6,197h. nelease by tnis procedure shan not exceed 3000 gallons of water in any eneg ay nor shall the concentration of radioactivity d
in the water exceed 2 x 10- uCi por milliliter. A copy of the current Washington Suburban Sanitary Cornission authorization for such dispossl, shall be furnished to the Department.
Conditien 13 is amended to read:
- 13. Except as specifically provided by this license, the licensee shall po,ssess and use radioactive material authorized by this licensa is accordance with statements, representations, and procedures contained in application dated
'l November 27,19o7, submitted to the US AEC and amendments thento subnitted l
and approved by the US AEC prior to December 31, 1970 and in letters dated i
3/23/71,10/6/71, H/h/71,11/12/71, $/10/72, 6/12/72, n/29/72,1/1h/7h, l
6/6/7h, and 10/20/75 5
9 For the Maryland State Department of Health and Mental Hygiene Date
() K
^ /$
A
- AJ e
Divison of Radiation Control OHM +300 4 (Suced
_ ~.
.f f'
(%
" h{h$ >
[
///
()/
l DEPARTMENT OF HEALTH AND MENTAL HYGIENE DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Page1of k pages Pursuant to Section 689 A of Article 43 of the Annotated Code of Maryland,1965 Replacement Volume,1969 Supplement, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued authorizing thelicensee to receive, acquire, possess and transfer radioactive material listed below; and to use suen'radioacthre material for the purpose (s) and at the place (s) designated below. Th% licente is subject to all applicable rules, regulations and orders of the Mary:and State Department of Health and Mental Hygiene, now or hereinaf ter in etfect and to any conditions specified below. In accordance with letter dated October 20,1975, Radioacti n Material License MD-31-025-01 is amended in its entirety.
LICENSEE
- 3. License No.
- 1. Name Neutron Products, Inc.
MD-31-025-01
- 4. Amendment No.
- 2. Address P. O. Box 95 Dickerson, Maryland 09
- 5. Expiration Date Noviraber 17, 1980
- 6. Radioactive material (element end mass 7 Chemical and/or physical form
- 8. Maximum amount of radioactivity wh!ch numt:r) licenwe may possess at any one time A. Cobalt 60 and sman A. NPI singly encapsulated A. 1,570,000 curies quantities of activation sources or other manufac-products in the zircaloy turer's doubly encapsulated tubing and stainless steel sources cap:ules B. Cobalt 60 B. Mallinckrodt Custom B.10 sources not to exceed Sources 15 millicaries each C. Cobalt 60 C. Sealed Sources C. No source to exceed 5 curies per source D. Cobalt 60 D. NPI doubly encapsulated D. No source to exceed 1000 l
sealed sources curies E. Cesium 137 E. Sealed sources manufactured E. 6 sources not to exceed lh by 3M 6D50 millicuries each
- 9. Au'.norized Use A. To be possessed, stored, and used in the canal and hbt cell for purposes of processing and redistribution to authorized recipients. Double encapsulated sources may be stored in the irradiator pool and used for the irradiation of various materials in the package goods batch irradiator.
Use of the hot cell for irradiation of materials is also authorized. The main posi may be used for possession and storage of radioactive sources only as necessary for the removal of all radioactive sources fem the pool. No radioactive source may be transferred to the main pool.
B. To be used in attenuation studies.
C. Ib be used as calibration sources.
D. To be used for calibration purposes in a Eeleket-Barnes " Rotary" teletherapy unit.
E. To be used for instrument calibration.
DHMH-400 4
Q
/
Q FEPARTMENT OF HEALTH AND MENTAL HYGIENE DMSION OF RADIATION CONTROL RADIOACTfVE MATERIAL LICENSE of b 2
Page pages Supplementary Sheet Uanse No.
Amendment No.
MD-31-025-01 09
- 6. Radioactive material
- 7. Chemical and/or
- 8. Maximum arount of radio-(clement and mass number) physic.21 form activity which licensee may possess at.any one time F. Any radioactive material F. Sealed instrument F. Total possession limit 1 otcaic number 3-92, check sources millicurie each radionu-cxcluding special nuclear clide. Total inventory 10 material m1111 curies
- 0. Radium 226
- 0. Sealed sources
- 0. No source to exceed 200 millicuries. Total inventory 3 curies
- 9. Authorized use F. For possession only of instrument check sources during instrument calibration.
O. For storage and source evaluation.
t For the Maryland State Department of Health and Mental Hygiene Date Divison of Radiation Control OHM +300-4 (Supo.)
/'
D b
~~?
f
?
?.
DEPARTMENT OF HEALTH AND MENTAL HY0lENE DIVISION OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE Pared _ of1pages Supplementary Sheet t.icense No.
Amendment No.
OCNDPt10NS, 10.
Radioactive material may only be used at the Neutron Products, Inc. Plant Complex located on Sugarloaf Road in Dickerson, Maryland.
11.
Radioactive material shall ba used by, or under the supervision of:
J. A. Hansohoff, M. M. Turkanis, D. L. Repp, E. T. Jacobs, J. R. Demory and Leroy Howard. Se radio-active material in the pilot plant irradiation cell may also be used by, or under the supervision of M. G. Woodard.
- 12. A. Each sealed source defined in items 6, 7, and BA containing radioactive material shall be tested for leakaBe and/or contamination at intervals and with methcds as described in subsissions dated October 6,1971 and November 12, 1971.
B. The tests of singly encapsulated sources are to be perfonned in accordance with the pmcedues described in the autriission dated October 6,1971. If the test reveals the presence of 0.05 microcurie or more of removable contamination, the licensee shall immediately withdraw the source from use and cause it to be decontaminated and repaired. Records of leak test results shan be kept in units of microcuries and maintained for inspection by the Department.
C. De test of doubly encapsulated sources are to be performed in accordance with the procedures described in the subnission dated October 6,1971. If the test for doubly encapsulated sources reveals the presence of 0.005 microcurie or more of removr.ble contamination, the licensee shall ire.ediately withdraw the aealed source from use and cause it to be decontaminated and/or repaired or to be disposed of in accordance with Department hegulations. A report shall be filed within five days with the Division or Radiation Control, Maryland State Department of Health and Mental Hygiene, 201 West Prest,on Street, Baltimore, Maryland 21201, describing the ecuipnent involved, the test results, and corrective action taken.
D. Each sealed source defined in items 6, 7, and 8B through 0 containing radioactive material shall be tested for leakage and/or contamination at intervals not to exceed six months. In the absence of a certificate from a transferor indicating that a test has been made within six months prior to the source transfer, the sealed source shall not be used until tested. Leak testing of sealed sources in items 6, 7, and 8B through 0 shall be tested in accordance with the procedure submitted in a letter dated October 6,1971 for sources used in NPI's hot cell. If the test reveals the presence of 0.005 microcurie or more of remoirable contamination, the licensee shall immediately withdraw the sealed source from use and shall cause it to-be decontamhated and I
l repaired or to be disposed of in accordance with Department Regulations. A report shall be filed within five days with the Division of Radiation Control, Maryland State For the Maryland State Department of Health and Mental Hygiene i Date Divison of Radiation Contron ohm,oo4 (suona
-m
DEPARTMENT OF HEALTH AND MENTAL HYGIENE OM510N OF RADIATION CONTROL RADIOACTIVE MATERIAL LICENSE b of b ages Page
_ p Supplementary Sheet License No.
Amendment No.
CONDITICNS (Cont'd.)
12.D.-(Cont'd.)
Department of Health and Nantal Hygiene, 201 West Preston Street, Balt$r. ore, Maryland 21201, describing the equipment involved, the test results, and the corrective action
-taken.
E. Test for leakage and/or contamination shall be perfomed try the licensee or by other persons specifically authorized by the Department, another Agreement State, or the Nuclear Energy Corniscion to perfonn such services.
13.
Except as stecifically pmvided by this license, the licensee shall possess and use radioactive material authorized by this license in accordance with statements, representations, and procedures contained in application dated November 27, 1967 submitted to the US AEC and amend:nents thereto subni.tted and approved by the 15 AEC prior to December 31, 1970 and in letters dated 3/23/71, 10/6/71, 11/h/71, 11/12/71, 5/10/72, 6/21/72,11/29/72,1/1h/7h, 5/1h/7h, 6/6/7h 7/15/74 and 10/20/75 For the Maryland State Department of Health and Mental Hygiene Da*, _
November 25, 1975 OL
.o JAs Divison of Radiation Control DHM4300-4 (Supp.)
HEUTP0l1 PF0 DUCTS VElf:1- %1-349-5007 Jun 05.97 15:08 110.005 P.03 14UU l'/100U b / d $f d}f f 5 hf0S. '
5 OTTICI 0F E NIE012LE11TAL PROGTwis DEPARTMENT OF HEALTH AND MENTAL HYGIENE 383 2744 Area Coce 741 e-RALTIMORE. MARYLANO 2120) e 201 WEST PRESTON STREET Charles R. Evek, Jr.. Sc,0. Secretsrv Harry Hughes. Govemo' Ilovember 12, 1980
- o I
Heutron Products, Inc.
Dickerson, Maryland 20153
' Attn:
Mr. Carmine Smedira Dear Mr. Smedira We have received your application for renewal' of Radioactive Material Your application is deened to be a tirely application for License MD-31-025-01.
renewal and accordingly, the license will remain in effect until final action has been taken by this office upon the application.
5incerely, fb.lL
$$$5" Robert E. Corcoran, Chief Division of Radiation Control REC /CWK/km it. David L. Ro sh cc:
e T
O i;w..~.
,-Y.
n..
er, a.,,,
- - +
IIEl)TP0tt FtDiil) CTS TEt:1-301-349-5007 Jun 05 97 15:11 140.005 P,04
[hris' i
fl h
DEPARTMENT OF HEALTH AND MENTAL HYGI O
OlVGON OF RADtATION CONTROL RADID ACTIVE MATERIAL. LICENSE Pope d of_?
pages Supplementary Sheet Amendment No. 12 License No. MD. 31025 01 Heutron Products, Inc.
Dickerson, Maryland 20753 In accordance with let rs dated February 16, 1977 and February 17,1977 is amended as follows:
Haterial License Number.MD-31-025-01 Change Item 8A to read: 3,000,000 Ci Item 9A is amended to read "To be processed, stored, and used in ' ho main storage pool, canal, and hot con for purposes of processing and redistribution to auth-9A.
Secondary encapsulation in tho hot con, and irradiation of various materials in the storage pool, the packago orized recipients.
goods batt h irradiator, and the hot een are also authorized.
The hot een may be used tos (1) open scaled courcer containing solid slugs, penets, clad wiro coils, ' solids' or 'hollowa; s (2) out the coils,(3) reassomble and encapsulate the segments and/or p Condition 13 is amended to reads Except as specificany providod by this licenso, the licenses shall and use radioactive matorial authorized by this license in acco 13 tion dated statements, representations, and proceduros contained 27, 1967, 31, 1970 and ir lettera dated November and approved by the US FRC prior to Decemoer
/ h/7b,
'3/23/71,10/6/71, n/h/71, n/12/71, 5/10/72, 6/12/72,11/29/72,11 6/6/7h,10/20/75, 2/16/77, and 2/17/77 For the Maryland StaNapartment of He:Ith i
~
and Mental HY0 ene l
DMoon of ftedietton Control Date _ February 17, 1977 DMadM 3004 {$up$,I O-
f1Ef fiPon penDUCTS TEL:1-301-349-5007 Jun 05.97 15:12 No.005 P.05
>~>
- t. -
At -
l l
a DEPARTMENT OF HEALTH AND MENTAL HYGIENE DIVISION OF RADIATION CONTROL i-RADIOACTIVE MATERIAL LICENSE
+
b I,
Pese 1 of pages i%rmaant to Section C89 A of Article 43 of the Annotated Code of Meryland,1965 Replacement Volume,1969 Supp
' rullenen on statements end representations heretofore mede by the licenses a license la hereby issued authoriz acquire, poenses and transfer radioactive material listed below; and to use such redloactive material for th f h Maryland State Department of Health and
.doelgnetad below.This 11 cense la subloct to all applioible rules, regulations and orders
.0ctober 20,1975, Radioactive Mat.eri..al License ED-31-02$-01 is amended in its entirety.,
..x x
..,; p,;;,_,
- -di.
_ 4;,;,.
1 ue,n no, D4,m;Q,y*%.'d., LicsuSen,e J outron Pnducts, Ins.. '.. --
a 11
_ HD-31-025-01 W W,- '.
~
l
- j'i!j.}.;'D 4,,Q, y,,
': Q -!.Q :.y: J -2:- Address.P. 0.. Box 95 4,;
., ;;q 2
. p.
07
- qc,.. Dichreson, Maryland 3.c..' i
- 5. Epptratica Date.
'.s.
- -l.12
't.",*..
s ' p'..: @
. n %.,
1, :.Q.4,',
^
J'
- - +.. ; <,'
. November 17, 1980 3.
4
- 8. Iledlooceve sneesrial (element and rnass
- 7. Chemical and/or phy:1 cal form 8, Max,lmum amount of radioactivity which licenses may possess at any one timt-
- r
,'y.f, *
- . number) j,,sgi f ~ ~'obalt 60 and a
- ::all '.
A. IEPI ' singly encapsulated A. 1,570,000 ouries,
,.,,j 4
~
sources or other manufac-
..santitias of activation
tunr's doubly encapsulated
- products in the sircalmy
'o_ tubing and atninlass steel
, sources
Wcapsules D.10 cources not to excond.
D. W 1 m h edt Custom B.. Cobalt 60 c
- Sources 15 mi.111 curies each
- 0. No source to eatened $ cur.ies
-m44 G'e ' Cobalt 60
.. _... 'O. Sealed Sources
.c.
per source D. NPI doubly encapsu24ted D. No source to exceed 1000 "
D, Cabalt 60 curies A
sealed sources.
E. Saaled sources nanufactured E. 6 sources not to e:cceed ik N S' E. Casina 137 n1211 curies each
- i, ;,. ' -,~
. by 3M 6D50. -
[.9.@;
3-[
h,.4*I f, 4 i
+-
C.,:' -
- g' ';p,J
.,.giy 7;,,.,.
3 g+
- 9. Ausnortred Usag.. -,
1,LTo be possessed, stored, and used in the canal and hot cell for purposes of proc Double. encapsulated sources may be stored in.the Sredistribution to authorized recipients.
hi jetirradiatur pool and.used.for the irradiation ot various materials in the package g i
f natarials is also authorized. The main
$ll.irradiator. ' Uam of the hot cell for irradist ca o
".: pool may be used for possession and storage of radioactive cources only as necess No ndioactive source may be transferred 4 removal of a21 radioactive sources fro:n the pool.
ito the main pool.
.D. To be used in at enuation studies.
t
'C. To be used as calibration sources.
. be used for calibration purposes in a Kolcket-Barnes "Ratary" teletherapy u=it.
....: be used for instrument r =1% tion.
4
! :~
p
,a e'
~
l
...~..-.
HFUTP0H PPnDUCTS T EL : 1.-301-349-5007 Jun 05.97 15:13 No.005 P.0C.
a m
~
>~
.r.
($
/,( {/)
s DEPARTMENT OF HEALTH AhD MENTAL HYGIENE DivistoH OF RADtAnoN CONTRot.
'.. la
.y
. RADIOACTIVE MATERIAL LICENSE j
2-oi hr.
g.N'.;
=. fi. :
... :V.
sk r.,e
~
. ',- \\
. '., * ~. ;.;'.
, r,.;g,'eg., f.suppledtery sheet g
.., c,.
Amendment No.
,.....-.,b.
no.31.og!l.'01 - N,..,
fg..g.,t%.. S...;
09 '
Usense No..
.r...
,_ w.
..-c.
. r,,, yl
.O
.. ~ -
. s :%
.s
- O c,. 4 v 2
' 6. Maximum' amount of radios.
'..,eRadioaotd.ve unterial.5.)
a.
' 7. Chendaal and/or 6
.?,(elmasat and saass atenber
.,7 / physical form
- i. ' l activity which 31censen may h':.,
. '.. _ ', { fbh Y.* :
7
, F.'Any radioactive materialc." " '.
F. Sealed instrument l'. Total possession lim'it 1 milliourie each radionu-,
" *M.oheck' sources
..f atcunic number 3-92,. -
l cudo. Total inventory 10
[..
~, -
milliouries d ( 4,:."
,0 excluding special nualsar; 1<
- 0. No source to exceed 200 material
.f i.;.G. Sealed sources
[,, ' '.ps'd. *h.,?b%..;f,..,
G. Baditsa 726\\
m1311curias. Total inventory f.,.,
I
. Utf"".
.c -
- ,,,' ;fyj.,.s.w \\r
.o
.' t 3 ouries
.. y
-~ s,.,
.o.p,
. rt z....-
C a
..4
,?
s
. %).) +
.. 3 4... 3 ',,,,.,
. o. s. c. 4.. n. a.. ;.p n..,:... 4,,3.,.
., s' Authorized use
,a F. Ibr possession 'only'of instrur.mnt check sourcos during instrument calibration.
f
- 0. For storage and source evaluation.
. r.:
3
.j.
t,
....s &.
- 3.,,t,.-
u y.,
- ,,.b.<.
..f
. - 4.-
.a m
..j q.
,}.
c,,.
/
c.,
- 't
.s: '.
.e
', = K.,.., y,..s
~'
r. ,'v A -Tp:. i . y.;t 1,,,',~. +.>A.>.>.,"..,.... A.,.. . s '. l',.. g%
- . ; < f..,, ?.
.n. ~
- .v.
- .:'.t....
- f..lrY
.; s s, ~:; .a + ,4.,,,. ,s ,3... .i a ~.. 4 t
- 4 for the Maryland State Departmemof Heenth,*
and Mental Hygiene Date DMson of Radiation Contfel 9 o..w aeo.4 ts eed ~.. - r
HEUTROH PPO, DUCTS _JEL:1-301-349-5007 Jun 05.97 15 : 13 14n,005 P.07 WNO%t ' "- AheWNT }_fuit l 24760 NOUTRON PRODUCTSinc. ~ y,, y Dkkerm,, Merytend 20H1 e _ _ _ tuns PAY._ au aw M._._--, o==a 2--- , oa9 io = caar - l, ()f[f41 , Apa,.a Wahe$m ) h)b t/9 l'l /06 cc y 9 q k se j r 1 n'O 2 4 7 GOn' i:0 5 2000 LGBi: 9 L Lea & 20 ba' (. 6 (
A TELEPHONE CONVERSATON RECORD Date: July 11. Time: 3:00 pm 1997 Mail Control No.: License No.: Docket No.: Person Called: Carl Trump. State Organization: State Telephone of Maryland of MD Number: (410) 631-3300 Person Calling: Eric H. Reber / (215) 337-5276
Subject:
Authorization of Neutron Products. Inc. Summary: Mr. Trump stated that he reviewed NPI's license and that they are only authorized for work at Dickerson, i e., no temp job sites Action Required /Taken: Date: Signature: s}}