Part 21 Rept Re Potential Safety Hazard for Some 3/4 Sch 40 Pipe Shipped to CP&L & VA Power Corp.Matl Has Been Found to Have Areas Where Wall Thickness Falls Below Minimum Allowed by SA 312 Specification.Customers Have Been Notified
ML20217H871
Person / Time
Site: North Anna  Dominion icon.png
Issue date: 10/15/1997
From: Dailey J
AFFILIATION NOT ASSIGNED
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-PT21-97 NUDOCS 9710170102
Download: ML20217H871 (3)


Text

ionsjef ti~:os FHisios90ss'ss'~

' ~ ' ~ oss6sEsss~~

~ ~ ~ ~ ' ' ' ~ ~

~

~

~~

coot DuBose 4

National Energy Services,Inc.

October 15,1997 l

i Attn: NRC Operations Center i

Document Control Desk US Nuclear Regulatory Commission l

Washington,DC 20555 L

Subject:

Potential 10 CFR 21 Dear Sir; i

i This letter is to iriform you of a potential safety hazard for some % Sch 40 pipe j

shipped to two or our customers, Carolina Power & Light and Virginia Power Corp. This material has been found to have areas where the wall thickness 2

falls below the minimum allowed by the SA 312 specification.

When the material was cut by Virginia Power Cog at their North Anna site this j

condition was found. The minimum wall thickness of.099 had been violated.

Some of the readings were as low as.087.

A sample of this material has 1 --a returned to Sandvik Steel, the producer, in Scranton, PA, for evaluation.

The orders were for %, schedule 40, Pipe SA 312, type 304. Carolina Power

& Light, PO #8N7398CJ had one piece 23' 11" and PO #8P8410CJ had 2

)

pieces totaling 46' 11", all of this material came from heat #46989.

]_t I c ' l

~1 <

The Virginia Power Corp orders were #CNT-552587, CNT-556011, & CNT-558917 for one piece each of % schedule 40 Pipe, SA 312, type 304. Each piece was 22' to 23' 6" random length from heat #46989.

971o17olo2 971o15

~~

PDR ADOCK 05o00339 S

PDR 1 b ') b $ >

(910) 590-2151 = 1800-590-2150 e FAX (910) 590 3555 P.O. Box 499

  • Clinton, NC 28328

10/15/97 14:06 FAI 19105903555 DUBOSE NES 66 002

~-

4 Each of these customer has been notified and we will notify them of any infonnation received from the producer of the pipe, when it is available. If I can be of any further assistance you may contact me at 1-800-590 9.150.

l --

Sincerely, M

James N. Dailey QA Manager copy: CarlRogers, President VP Sales Sales Manager

. v.

GENERAL INFORMATION or OTHER EVENT NUMBER:

33088 LICENSEE: DUBOSE NATIONAL ENERGY SERVICES INC NOTIFICATION DATE: 10/15/97 CITY: CLINTON REGION: 2 NOTIFICATION TIME: 15:06 [ET]

COUNTY:

STATE: NC EVENT DATE:

10/15/97 LICENSE #:

AGREEMERT: Y EVENT TIME:

00 : 00 (EDT)

DOCKET:

LAST UPDATE DATE:

10/15/97 NOTIFICATIONS THOMAS PEEBLES RDO NRC NOTIFIED BY: DAILEY(FAX)

VERN HODGE NRR HQ OPS OFFICER:

CHAUNCEY GOULD EMERGENCY CLASS: NOT APPLICABLE 10 CFR SECTION:

CCCC 21,21 UNSPECIFIED PARAGRAPH EVENT TEXT DUBOSE NATIONAL ENERGY SERVICES INC SUBMITTED A POTENTIAL PART 21 REPORT.

(

THE " DEFECT" IN QUESTION IS SOME 3/4" SCH 40 PIPING WHICH MAY HAVE WALL THICKNESS AS LOW AS.087" WHEN THE MINIMUM ALLOWED BY SA 312 SPECIFICATIONS IS.099".

THIS PIPING WAS SHIPPED TO CAROLINA POWER & LIGHT AND VIRGINIA POWER AND THE NORTH ANNA SITE DISCOVERED THIS CONDITION.

THEY HAVE RETURNED A SAMPLE OF MATERIAL TO THE PRODUCER, SANDVIK STEEL, FOR EVALUATION.

BOTH SHIPMENTS OF PIPING TO THE TWO CUSTOMERS HAD THE SAME HEAT #46989.

THE CUSTOMERS HAVE BEEN NOTIFIED.