ML20217F965

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs Page 3/4 5-5 Re Venting of Operating Chemical Vol & Control Sys Centrifugal Charging Pump
ML20217F965
Person / Time
Site: Seabrook 
Issue date: 04/21/1998
From:
NORTH ATLANTIC ENERGY SERVICE CORP. (NAESCO)
To:
Shared Package
ML20217F964 List:
References
NUDOCS 9804280326
Download: ML20217F965 (1)


Text

1 l

EMERGENCY CORE COOLING SYSTEMS 1

  • ECCS SUBSYSTEMS - T_.c GREATER THAN OR EOUAL TO 350*F l

T SURVEILLANCE REQUIREMENTS 4.6.2 Each ECCS subsystem shall be demonstrated OPERABLE:

1 a.

At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by verifying that the following valves are in l

the indicated positions with power to the valve operators removed:

Valve Number Valve Function Valve Position SI-V-3 Accumulator Isolation Open*

)

SI-V-17 Accumulator Isolation Open*

l SI-V-32 Accumulator Isolation Open*

l SI-V-47 Accumulator Isolation Open*

SI-V-114 SI Pump to Cold-Leg Isolation Open RH-V-14 RHR Pump to Cold-Leg Isolation Open RH-V-26 RHR Pump to Cold-Leg Isolation Open RH-V-32 RHR to Hot-Leg Isolation Closed RH-V-70 RHR to Hot-Leg Isolation Closed SI-V-77 SI to Hot-Leg Isolation Closed SI-V-102 SI to Hot-Leg Isolation Closed b.

At least once per 31 days by:

1)

Verifying that the ECCS piping is full of water by venting the ECCS pump casings (excluding the operating centrifugal charging pump) and accessible discharge piping high points, and l

2)

Verifying that each valve (manual, power-operated, or automatic) in the flow path that is not locked, sealed or otherwise secured l

in position is in its correct position.

c.

By a visual inspection which verifies that no loose debris (rags, trash, clothing, etc.) is present in the containment which could be transported l

to the containment sump and cause restriction of the pump suctions during i

LOCA conditions. This visual inspection shall be performed:

1)

For all accessible areas of the containment prior to establishing j

primary CONTAINMENT INTEGRITY, and 2)

At least once daily of the areas affected within containment by containment entry and during the final entry when primary CONTAINMENT INTEGRITY is established.

  • Pressurizer pressure above 1000 psig.

(

SEABROOK - UNIT 1 3/4 5-5 Amendment No. M

Bg.2eggggBggg2 j

P