1 l EMERGENCY CORE COOLING SYSTEMS l 1

  • ECCS SUBSYSTEMS - T_.c GREATER THAN OR EOUAL TO 350*F  !

l T

SURVEILLANCE REQUIREMENTS 4.6.2 Each ECCS subsystem shall be demonstrated OPERABLE:

1

a. At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by verifying that the following valves are in '

l the indicated positions with power to the valve operators removed:

Valve Number Valve Function Valve Position SI-V-3 Accumulator Isolation SI-V-17 Accumulator Isolation Open*

Open*

)

l SI-V-32 Accumulator Isolation Open*

l SI-V-47 Accumulator Isolation Open*

SI-V-114 SI Pump to Cold-Leg Isolation Open RH-V-14 RHR Pump to Cold-Leg Isolation Open RH-V-26 RHR Pump to Cold-Leg Isolation Open RH-V-32 RHR to Hot-Leg Isolation Closed RH-V-70 RHR to Hot-Leg Isolation Closed SI-V-77 SI to Hot-Leg Isolation Closed SI-V-102 SI to Hot-Leg Isolation Closed

b. At least once per 31 days by:
1) Verifying that the ECCS piping is full of water by venting the ECCS pump casings (excluding the operating centrifugal charging pump) and accessible discharge piping high points, and l
2) Verifying that each valve (manual, power-operated, or automatic) in the flow path that is not locked, sealed or otherwise secured l in position is in its correct position.
c. By a visual inspection which verifies that no loose debris (rags, trash, clothing, etc.) is present in the containment which could be transported l to the containment sump and cause restriction of the pump suctions during i

LOCA conditions. This visual inspection shall be performed:

1) For all accessible areas of the containment prior to establishing j primary CONTAINMENT INTEGRITY, and
2) At least once daily of the areas affected within containment by containment entry and during the final entry when primary CONTAINMENT INTEGRITY is established.
  • Pressurizer pressure above 1000 psig.

('

SEABROOK - UNIT 1 - 3/4 5-5 Amendment No. M