C mimonw cahh lilimn Compan)-

II,) ton Generating Station

, 4 440 North Gernun Churt h 14aad II) ton. ll. 6 t olO 979 4 Tel M1423 6 5141 September 15, 1997 LTR: BYRON 97-0211 FILE: 3.03.0800 (1,10.0101)

U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555

Dear Sir:

The Enclosed Security Event Report from Byron Generating Station is being transmitted to you in accordance with the requirements of 10CFR50.73.71.

This report is number 97-S01-00; Docket No. 50-454.

Sincerely,

/ .

?

W S

~

K. L. Kofron Station Manager Byron Nuclear Power Station KLK/MS/js

Enclosure:

Security Event Report No. 97-S01-00 cci A. B. Beach, NRC Region III Administrator NRC Senior Resident Inspector INPO Record Center t Comed Distribution List Director of Corporate Security If- )

Byron Station Security Administrator 9709190173 970915 PDR ADOCK 05000454 S PDR ll lh! ll (p:\regassur\pillerWAWhs4)0$W90$97)

NRC. FORM 366 U.S. NUCLEAR REout ATORY COMMISSION APPAOvED BY OMB NO. 3150 01o4 14 9'il EXPIRES 04/30/98 (StiMATED BURDEN PER RESPONSI 10 COMPLV WITH THl3 MAND 410R1 INFORMAil0N CDuttil0N REQUtsi: 500 HRS. REPORTIO LESSONS LIARNED ANI SECURITY EVENT REPORT (SER) $CfggD,,Q 1,",5y{tj5y,3%DCllQ j,tD,,8,'Cg,gst,Rg (See reverse for required number of RECOROS MANAGEMENT $ RANCH (16 F31 U S NUCLE AR REGULATORY COMulS$40N.

wAssiNGTON. DC 20sss000t AND 10 THE PAPERWDRK REQUCTION PROJEtt o150 digits / characters for each block) 0104L OFFICE OF MAliAGEMENT AND BUDGET. WASHINGTON. DC 20503 f AClulv hAMG Op DOCRif huMBER 12) PAOt (3)

BYRON NUCLEAR POWER STATION, UNIT 1 05000454 1OF4 title 14p UNESCORTED VISITOR IN PROTECTED AREA EVENT DATE (5) SER NUMBER (6) REPORT DATE (7) OTHER FACILITIES INVOLVED (B)

F ACiUTY NAM 4 DOCK 4T NUMBER QU R CONTH DAY YEAR YEAR MONTH DAY YEAR NM R BYRON, UNIT 1 05000454 7 ACauTV NAME DOCKETNUMBER 08 15 97 97 --

SO1 --

00 09 15 97 BYRON, UNIT 2 05000455 OPERATING THIS REPORT IS SUBMITTED PURSUANT To THE REoulREMENTS OF 10 CFR 6: (Check one or more) (11)

MODE (9) 1 20.2201(to 20.2203(aH2Hv) 50.73(aH2H0 50.73(aH2Hvud POWER 20.2203(aH1) 20.2203(aH3Hi) 50.73(aH2Hn) 50.73(aH2Hx)

LEVEL (101 96 20.2203(aH2H0 20.2203taH3Hu) 50.73(aH2Hm) X 73.71 20.2203(aH2Hu) 20.2203(aH4) 50.73(aH2Hav) OTHER 20.2203(aH2Hud 50.36(CHI) 60,73(aH2Hv) c' below

[pecign, Abs 66 20.2203(aH2Hiv) 50.36(cH2) 50.73(aH2hvus LICENSEE CONTACT FOR THIS SER (12)

NAME T4LEP> TONE NUMutR t WMse A,ea Codel Sidney Kraus, SEC Root Cause 815 234-5441, x2759 COMPLETE ONE LINE FoR EACH COMPONENT FAILURE DESCRIBED IN THis REPORT (t h CAUSE SYSTEM COMPONENT MANUFACTURER R R AB E CAUSE SYSTEM COMPONENT MANUFACTURER N 0 l

SUPPLEMENTAL REPORT EXPECTED (14) MUNIH DAY MAR EXPECTED YES SUBMISSION (if yes. complete EXPECTFD SUBMISSION DATE). X NO DATE (15)

ABSTRACT (Limit to 1400 spaces. i.e.. approximately 15 single-spaced typewritten lines) (16)

A contractor visitor required to have an escort, inadvertently became separated from his escort within the Protected Arsa for approximately 30 minutes. The badgad contractor personnel assigned as escort, was given a work assignment in a different location and left the visitor unescorted. A USNRC Inspector noticed the unescorted visitor and immediately accepted escort duties and notified the Station Security Force about the event.

The badged contrutor escort did not comply with the escort duties.

From a risk perspective, this Security event did not increase the probability of an initiating accident that would require tha plant safety systems to mitigate the consequences of the accident.

The following previous occurrences were found to be applicable to this event: " Unescorted Visitor found by a USNRC inspector" is related in titto only as the unescorted violation occurred due to only a 1 minute time delay. " Violation of Visitor Escort Procedures" is related in title only as both escorts allowed more than the permitted number of visitors into a vital area.

This event is submitted pursuant to the requirements of 10CFR 73.71, Physical Security.

(p:\regassur\piller\ser\97-s-01.wplT090597)

\ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .

NRC. FORM 366A

  • U.S. NUCLEAR REoVLATO2Y Commission I4 951 SECURITY EVENT REPORT (SER)

TEXT CONTINUATION FACILITY NAME (1) DOCKET sER NUMBER (6) PAoE (3)

YUR SEQU[NilAL REVISION NUMBER NUMBER BYRON NUCLEAR POWER STATION, UNIT 1 05000454 2 M 4 97 .. 303 .. og TEXT tif snore space is required, use additional copies of NRC Forrn 366Al (11)

A. PLANT CONDITIONS PRIOR TO EVENT:

Event Date/ Time 08 15-97 /1040 B. DESCRIPTION OF EVENT:

On Augt at 15,1997 at 9:50 a.m., a contractor pipe fitter / welder visitor, was escorted by the Contractor Supervisor of the weld testing area during his welding activity. The Contractor Supervisor turned over the escort duties to a badged contractor pipe fitter / welder, in the same area. At 10:00 a.m. the contractor craft personnel went to the morning break area which ended at approximately 10:10 a.m. At the end of break, the contractor escort made a misjudgment when he did not continue his escort duties of the visitor, as he was assigned other work.

Af ter break, the contractor visitor returned back to the weiding booth unescorted and continued with the weld testing activity. He remained there until 10:40 a.m. (approMmately 30 minutes) when a USNRC inspector approached him and asked where his escort was. Since the escort had been assi0 ned other duties, he was not imrnediately available. The USNRC inspector accepted escort duties and called Station Security, which dispatched a Security Supervisor to assess the event.

Appropriate Security procedures were implemented by Station Security Supervision personnel to regain control of the visitor and escort personnel, who were eventually removed off site at 12:19 p.m. Both individuals are currently on administrative hold and written warnings were placed in their employment files per Bechtel Site Policy.

An ENS phone call was completed at 1141 hrs., which was within one tour of the notification to the Station Security Depe" ment. Also, notification was made to USNRC on site, Byron Station Duty Officer, Corporate Nuclear Duty Officer and the Station Manager.

This report is submitted pursuant to the requirements of 10CFR 73.71, Physical Security.

C. CAUSE OF EVENT:

The badged contractor escort did not comply with the escort duties.

D. SAFETY ANALYSIS:

This area is not applicable to Security Event Reports. From a risk perspective, this Security event did not increase the probability of an initiating accident that would require the plant safety systems to mitigate the consequences of the accident. The safety of the plant and the public was not affected by this condition.

(p:\regassur\piller\ser\97-s-01 wptT090597)

N8tC FORM 366A U.S. NUCLEAR REoULAToRY COMMISSloN M 99 SECURITY EVENT REPORT (SER)

TEXT CONTINUATION -

FACILITY NAME (1) D0CKET SER NUMBER (6) PAoE (3) yg SEQUENTIAL REVISION NUMBrR NUMBER BYRON NUCt. EAR POWER STATION, UNIT 1 05000454 9 7 .. so) ..

oo TEXT (11 more space as requored, use additionalcopies of NRC Form 366A (11)

E. QORRECTIVE ACTIONS:

Immediate Corrective Actions:

The USNRC took control of escort duties.

Station Security responded and implemented security procedures to contiol the event.

The visitor and his escort were escorted off site and placed on temporary hold.

Corrective Actions to Prevent Recurrence:

The badged contractor escort was counseled on the escort and visitor site requirements by Bechtel Supervision on 8/15/97.

The Lodged contractor escort was re trained regarding escort and visitor duties by Burns Security Supervision on 8: 15/97.

Bechtel Supervision re trained all field craft personnel, including the escort and visitor.

Bechtel Supervision re trained all management personnel.

Bechtel QA performed a surveillance en all visitor's under Bechtel's escorts and found no other violations.

Bechtel Corporation to perform a follow-up surveillance on various Bechtel escorts and their duties to determine program adherence. This item to be tracked by NTS 454-181-97-CAQD00001 01.

F. RECURRING EVENTS SEARCH AND ANALYSIS:

The following keywords were used for the Data Base search:

Visitor $, Escort $, Security $

The following events were found applicable:

454-20193 5350 " Unescorted Visitor found by USNRC Inspector" This event was related by title only in that no unescorted violation occurred. One minute e: lapsed without escort present. Security incident report written. Closed to Security investigation.

454 20197-CAOD 02232 " Violation of Visitor Escort Procedures" The Reportability Manual was reviewed for this event and deemed that this event was not reportable. This event was related in title only, as both escorts allowed more than the permitted number of visitors into the vital area. The escorts involved were counseled by the Security Force as to the importance of visitor escort responsibilities.

(pSregassur\piller\ser\97-s-01.wpl\090597)

NRG FOHM V>6A U.S. NUCLEAR REGULATORY COMMISSION an SECURITY EVENT REPORT (SER)

TEXT CONTINUATION F ACILITY NAME (1) DOCKET SER NUMBER 16) PAGE (3)

YEAR SEQUENTIAL REVISION NUMBER NUMBER 4 4 BYRON NUCLEAR POWEn STATION, UNIT 1 05000454 97 .. 301 ..

oo TEXT Ilf more space is required, use ad$tional copies of NRC Form 366A) til}

G. COMPONENT FAILURE DATA:

Manufacturer Nomenclature Modal Number Mfo. Part Number NONE. No aquipment f ailures were involved in this event.

(p:\regassur\piller\ser\97-s-01.wpf\090597)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ._