OCT 301986 Distribution-Docket Nos. 50-325/324 6 Docket, Files JPartlow NRC & L PDRs NThompson Branch Files RBernero Mr. E. E. Utley ACRS (10)
Glainas Senior Executive Vice President SNorris OGC-Bethesda Power Supply and Engineering ESylverster GHulman and Construction EJordan Carolina Power & Light Company BGrimes Raleigh, North Carolina 27602 Dear Mr. Utley
SUBJECT:
HYDR 0 GEN RECOMBINER CAPABILITY Re:
Brunswick Steam Electric Plant, Units 1 and 2 By letter dated March 20, 1986, you provided additional information relative to Brunswick Steam Electric Plant compliance with the criteria of Generic Letter 84-09, "Recombiner Capability Requirements of 10 CFR 50.44(c)(3)(ii)".
This information was requested by the NRC staff in a meeting with Carolina Power and Light Company on January 14, 1986. A concern was expressed by the staff at that meeting that the post-accident switch-over from air to nitrogen for the pneumatic control system within the drywell does not meet the intent of the Generic Letter 84-09 criteria regarding removal of oxygen sources from primary containment.
We.have reviewed your submittal of March 20, 1986 along with your previous submittals of June 8 and June 27, 1984 and March 1 and July 18, 1985 in response to Generic Letter 84-09. The results of.our review are provided in the enclosed Safety Evaluation. We have determined that the nitrogen switchover system, as currently designed, does not meet Criterion 3 of Generic Letter 84-09. We therefore conclude that all potential oxygen sources, including the instrument air system, should be removed from the primary containment, or recombiner capability consistent with Generic Letter 84-09 should be provided to demonstrate compliance with 10 CFR 50.44. An acceptable method to assure removal of oxygen sources from containment is described in the Safety Evaluation. We request that you provide your commitment and schedule for removing the oxygen sources from the primary containment or providing hydrogen recombiner capability within 45 days of receipt of this letter.
Sincerely,
" hIvester, Project Manager 8611050296 861030 et DR ADOCK 0500 4
p BWR Project Directorate #2 1
Division of BWR Licensing
Enclosure:
As stated cc: w/ enclosure See next page DB p#1 DB D#2 DBL:PD#2 SB AD SN ri ESylvester:jch G man GL s
DM br 10/4 3/86 10/7h/86 10 86 10
/86 10/f/86
~
a.
t T
F Mr. E. E. Utley Brunswick Steam Electric Plant s
Carolina Power & Light Company Units 1 and 2 CC:
Mr. P. W. Howe Mr. C. R. Dietz Vice President Plant-General Manager Brunswick Nuclear Project Brunswick Nuclear Project Box 10429 Box 10429 Southpcrt, North Carolina 28461 Southport, North Carolina 28461 Thomas A. Baxter, Esquire Mr. H. A. Cole Shaw, Pittman, Potts & Trowbridge Special Deputy Attorney Ger.eral 2300 N Street, N. W.
State of North Carolina Washington, D. C.
20037 Post Office Box 629 Raleigh, North Carolina 27602 Mr. D. E. Hollar Associate Ger.eral Counsel Mr. Robert P. Gruber Carolina Pcwer & Light Company Executive Director Post Office Box 1551 Public Staff - NCUC Raleigh, North Carolina 27602 Post Office Box 29520 Raleigh, North Carolina 27626-0620 Mr. Christopher Chappell, Chairman Board of Comissioners.-
Post Office Box 249 Bolivia, North Carolina 28422 Mrs. Chrys Baggett State Clearinghouse n-sudget and Management 116 West Jones Street Raleigh, North Carolina 27603
?
?
Resident Inspector U. S. Nuclear Regulatory Commission Star Route 1 r
Post Office Box 208 Southport, North Carolina 28461 Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, Suite 2900 Atlanta, Georgia 30303 Mr. Dayne H. Brown, Chief Radiation Protection Branch Division of Facility Services N. C. Department of Human Resources 701 Barbour Drive Raleigh, North Carolina 27603-2008