Approval Proc"duro No.
Vogtle Electric Generating Plant 11951-C 4
h' I K@lGw)
NUCLEAR OPERATIONS g,y,3,on no, b
Date 3
COMMON Georgia Power
/c/6/66 unit ease no PLANT A. W. V0GTLE FUEL HANDLING OPERATOR AND FUEL HANDLING SUPERVISOR QUALIFICATION CHECKLIST NAME:
EMPLOYEE NO.:
I.-
SCHEDULED COMPLETION DATE:
CHECKLIST APPROVED FOR USE OPERATIONS SUPT./DATE 1
l 1
0611030419 861027 PDR ADOCK 05000424 E
PDR rwo,s ex
tRoCEDURE No.
REVISloN PAGE No.
i 11951-C 3
2 of 9 1.0 PURPOSE The purpose of this procedure is to ensure an acceptable level of competency and proficiency of all Fuel Handling Operators and Fuel Handling Supervisors.
2.0 SCOPE 2.1 All Plant Operators assigned the task of Fuel Handling Operator must be qualified in accordance with the applicable checklist (s).
2.2 All SROs assigned the task of Fuel Handling Supervisor must be qualified in accordance with the applicable checklist (s).
3.0 METHOD The trainee's supervisor shall review the applicable a.
qualification checklist to determine what training is' required for the trainee.
This review shall be based on FSAR commitments, the individual's experience, background and training records.
b.
The supervisor will obtain the Operations Superintendent's approval of the proposed training, then review the checklist with the trainee.
Once a checklist item is completed the Training c.
Instructor, trainee's supervisor, or other qualified person assigned to evaluate the trainee will sign and date the qualification checklist signifying successful completion of that item.
d.
After all required training is completed the trainee's supervisor will review the Qualification Checklist for completeness and sign the appropriate ' locks of Section o
B of the checklist.
The trainee's supervisor will then submit the qualification checklist to the Operations Superintendent.
e.
Once completed, the qualification checklist will be retained by the Training Superintendent as a training record.
- C3445
3
.e' PROCEDURE NO.
REVISION PAGE NO-11951-C 3
3 of 9 EMPLOYEE:
SECTION A:
SYSTEM QUALIFICATION:
Operations Department personnel must obtain a satisfactory knowledge of the applicable plant systems.
This will be demonstrated by successful completion of direct manipulation of the system involved to the satisfaction of the qualified individual assigned to verify the trainee's knowledge.
SECTION A-1:
GENERAL General Employee Training successfully completed
/
cws
. ~..... _,,
PROCEDURE No.
REVISloN PAGE No.
11951-C 3
4 of 9 FUEL HANDLING OPERATOR QUALIFICATION PART fl SECTION A-2 1)
Technical classroom lecture covering the spent fuel ~ cask bridge crane, new fuel assembly handling tool, rod cluster control assembly handling tool, new fuel storage racks, fuel handling area layout, sequence of events associated with new fuel receipt, unloading, inspection and storage.
/
2)
Operation of the spent fuel cask bridge crane (all components except 125 ton main hoist).
/
3)
Demonstrated Crane Operator Flagman signaling techniques.
capability.
/
-7 4)
Demonstrated basic rigging techniques capability for light load handling systems.
/
5)
Simulated fuel handling ope 7..itions (Part #1)
A)
Upendinfuelshippingcontainer.of dummy fuel assembly secured to st of new
/
B)
Latching and unlatching of new fuel assembly handling tool to dummy fuel assembly.
/
C)
Movement of dummy fuel assembly suspended from the new fuel assembly handling tool utilizing the spent fuel cask bridge crane monorail unit.
/
D)
Latching and unlatching of rod cluster control avsembly handling tool to dummy rod cluster control assembly.
/
7C3445
e
. PROCEDURE No.
REVISloN PAGE No.
11951-C 3
5 of 9 E)
Cleaning techniques for the new fuel assembly handling tool and rod cluster control assembly handling tool.
/
F)
Unsecuring/ securing dummy fuel assembly to strongback of new fuel shipping container.
/
G)
Movement of dummy fuel assembly into/from new fuel shipping container utilizing the spent fuel cask bridge crane monorail.
/
REMARKS:
.s SECTION B-2 FINAL QUALIFICATION DETERMINATION NOTE:
Part 1 qualification is for new fuel assembly handling during new fuel receipt unloading, inspection, storage and subsequent new fuel movements utilizing the spent fuel cask bridge crane.
1)
Qualification checklist complete / recommended for qualification " Fuel Handling Operator Part #1".
/
Trainee's Supervisor Date 2)
Qualified as " Fuel Handling Operator Part #1".
l l
j Operations Supt.
Date l
l l
703445
)
PfoCEDURE No.
REVISION PAGE Wo.
11951-C 3
6 of 9 FUEL HANDLING OPERATOR QUALIFICATION PART #2 AND FUEL HANDLING SUPERVISOR QUALIFICATION SECTION A-3 1)
Technical classroom lecture covering the fuel handling machine, new fuel elevator, new fuel assembly handling tool, spent fuel assembly handling tool, burnable poison rod assembly handling tool, new fuel storage racks, spent fuel storage racks, Fuel Handling Building layout, sequence of events associated with new fuel receipt and normal refueling operations.
/
2)
Operation of the fuel handling machine.
/
3)
Operation of the new fuel elevator.
/
4)
Operation of the burnable poison rod assembly handling tool.
/
5)
Simulated fuel handling operations (Part #2)
A)
Movement of the dummy fuel assembly suspended from the new fuel assembly handling tool between the new fuel storage racks and the new fuel elevator utilizing the fuel handling machine.
/
B)
Latching and unlatching of the spent fuel assembly handling tool to the dummy fuel assembly.
/
C)
Movement of the dummy fuel assembly suspended from the spent fuel assembly handling tool between the new fuel elevator and the spent fuel storage racks and/or the transfer system upender utilizing the fuel handling machine.
/
REMARKS:
rows
PROCEDURE No.
REVISloN PAGE NO.
11951-C 3
7 of 9 SECTION B-3 FINAL QUALIFICATION DETERMINATION NOTE:
Part 2 qualification is for new fuel movements associated with new fuel receipt, initial core load and normal refueling operations utilizing the fuel handling machine and new fuel elevator.
1)
Qualification checklist complete / recommended for qualification Fuel Handling Operator Part #2.
/
Trainee's Supervisor Date 2)
Qualified as Fuel Handling Operator Part #2.
/
Operations Supt.
Date 3)
Qualified as " Fuel Handling Supervisor Part #2.
.a
/
Operations Supt.
Date NOTE:
There is no requirement for a Fuel Handling Supervisor Part 1.
N3445 L
, PROCEDURE No.
REVIStoN PAGE Wo.
11951-C 3
8 of 9 FUEL HANDLING OPERATOR QUALIFICATION PART #3 AND TUEL HANDLING SUPERVISOR QUALIFICATION SECTION A-4 1)
Technical classroom lecture covering the Fuel Transfer System, Sigma refueling machine, refueling machine monorail unit, control rod drive shaft unlatching tool, control rod drive shaft handling tool, thimble plug storage rack, rod cluster assembly storage rack, control rod drive shaft storage rack, containment refueling area layout, sequence of events associated with initial core load and refueling operations or Senior Reactor Operator Training Program Procedure 60601-C, " Senior Reactor Operator Licensed Operator Training Program" Section 4.1.3.2b(5).
I
/
2)
Operation of the Fuel Transfer System.
/
3)
Operation of the Sigma refueling machine.
/
4)
Operation of the refueling machine monorail unit.
/
5)
Operation of the control rod drive shaft unlatching tool.
(Not required for initial core load)
/
j 6)
Operation of the control rod drive shaft handling tool.
(Not required for initial core load) 1 i
/
7)
Simulated fuel handling operations (Part #3) l A)
Movement of dummy fuel assembly with the Fuel Transfer System.
/
B)
Movement of dummy fuel assembly with the Sigma refueling machine between the Fuel Transfer System and the reactor core.
/
i roun
r j ! PROCEDURE No.
REVISloN F AGE No.
11951-C 3
9 of 9 k
C)
Movement of dummy rod cluster assembly with Sigma refueling machine between the dummy fuel assembly and the rod cluster control assembly storage rack.
/
D)
Movement of dummy thimble plug with Sigma refuel'ng machine between the dummy fuel assembly and the thimble plug storage rack.
/
REMARKS:
- I.
SECTION B-4:
FINAL QUALIFICATION DETERMINATION NOTE:
Part 3 qualification is for new fuel movements / component movements associated with initial core load, refueling operations utilizing the Fuel Transfer f"
System, Si equipment /gma refueling machine and associated tools.
1)
Qualification checklist complete / recommended for qualification " Fuel Handling Operator Part #3".
/
Trainee's Supervisor Date 2)
Qualified as Fuel Handling Operator Part #3.
1
/
l Operations Supt.
Date 3)
Qualified as Fuel Handling Supervisor Part 13.
/
Operations Supt.
Date l
l i
I 4 3445
.,, _ _ _.,.