ML20215L054

From kanterella
Jump to navigation Jump to search
Guidelines and Procedures for the International Code Assessment and Applications Program
ML20215L054
Person / Time
Issue date: 04/30/1987
From: Bessette D, Hanson R, Ting P
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To:
References
NUREG-1271, NUDOCS 8705120086
Download: ML20215L054 (80)


Text

,

e a

/

NUREG-1271 j

Guidelines and Procedures for the International Code Assessment and Applications Program l

)

-.-4


se+

.s**'e'-ww w ee

  • ==

.=---'-Ww--+.ns.--~-mee6 m.

U.S. Nuclear Regulatory Commission Offico of Nuclear Regulatory Research p " "'"%,

ia

.+

I!f!

g PDR

\\

NOTICE Availability of Reference Materials Cited in NRC Publicate Most documents cited in NRC publications will be available from one of the following sources:.

1. The NRC Public Document Room,1717 H Street, N.W.

Washington, DC 20555

2. The Superintendent of Documents, U.S. Government Printing Office, Post Of fice Box 37082, Washington, DC 20013 7082
3. The National Technical Information Service, Springfield, VA 22161 Although the listing that follows represents the majority of documents cited in NRC publications, it is not intended to be exhaustive, Referenced documents available for inspection and copying for a fee from the NRC Public Docu.

ment Room include NRC correspondence and internal NRC memoranda; NRC Office of Inspection and Enforcement bulletins, circulars, information notices, inspection and investigation notices; Licensee Event Reports; vendor reports and correspondence; Commission papers; and applicant and licensee documents and correspondence.

The following documents in the NUREG series are available for purchase from the GPO Sales Program: formal NRC staff and centractor reports, NRC sponsored conference proceedings, and NRC booklets and brochures. Also available are Regulatory Guides, NRC regulations in the Code of Federal Regulations, and Nuclear Regulatory Commission issuances.

Docurrents available from the National Technical Information Service include NUREG series reports and technical reports prepared by other federal agencies and reports prepared by the Atomic Energy Commission, forerunner agency to the Nuclear Regulatory Commission.

Documents available from public and special technical libraries include all open literature items, such as books, journal and periodical articles, and transactions. Federal Register notices, federal and state legislation, and congressional reports can usually be obtained from these libraries.

Documents such as theses, dissertations, foreign reports and translations, and non-NRC conference proceedings are available for purchase from the organization sponsoring the publication cited.

Smgle copies of NRC draf t reports are available free, to the extent of supply, upon written request to the Division of Technical information and Document Control, U.S. Nuclear Regulatory Com.

mission, Washington, DC 20555.

Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at the NRC 1.ibrary, 7920 Norfolk Avenue, Bethesda, Maryland, and are available there for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from the American National Standards institute,1430 Broadway, New York, NY 10018.

NUREG-1271 Guidelines and Procedures for the International Code Assessment i and Applications Program n": w t::ter"

  • Divisi:n of Reactor and Plant Systems Offico of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission W:shington, DC 20666 f..a a'a.,,,

Q

ABSTRACT This document presents the guidelines and procedures by which the International Code Assessment and Applications Program (ICAP) will be conducted. The document summarizes the management structure of the program and the relationships between and responsibilities of the United States Nuclear Regulatory Commission (USNRC) and the international participants. The procedures for code maintenance and necessary documentation are described. Guidelines for the performance and documentation of code assessment studies are presented. An overview of an effort to quantify code uncertainty, which the ICAP supports, is included.

1 l

111

CONTENTS PAGE PREFACE...............................................................

ix j

ACKN0WLEDGEMENTS......................................................

xi 1.

INTRODUCTION....................................................

I 2.

MANAGEMENT OF THE INTERNATIONAL CODE ASSESSMENT ANO APPLICATIONS PROGRAM............................................

5 2.1 Management Structure and Relationships......................

5 1

2.1.1 Program Coordination.................................

5 i

2.1.2 Program Management Group...........................

5 i

2.1.3 Task Group..........................................

7 j

2.1.4 Specialist Meetings.................................

8 2.2 Responsibilities of Program Participants....................

8 2.2.1 United States Nuclear Regulatory Commission (USNRC).............................................

8 1

2.2.2 International Participants..........................

9 2.3 Responsibilities of Contact Persons........................

9 2.3.1 United States Nuclear Regulatory Commission (USNRC).............................................

9 2.3.2 International Participants..........................

10 2.4 Protection of Information..................................

10 l

3.

PROCEDURES FOR CODE MAINTENANCE.................................

12 l

3.1 Freezing of the Code for Assessment and Application........

12 3.2 Procedure for Error Corrections............................

12 i

3.3 New Code Versions..........................................

12 4.

REPORTING AND DOCUMENTS.........................................

15 4.1 Di stribution of Information................................

15 1

l 4.2 Code and Related Documentation.............................

15 4.3 Code Assessment and Validation Matrices....................

17 a

1 i

l v

2

1 4.4 Assessment Reports, Executive Summaries and Data Packages...................................................

17 4.5 USNRC Review of Assessment Reports.........................

18 4.6 Newsletter Service.........................................

18 4.7 To p i c al Re po r t s............................................

19 4.8 Information Storage and Retrieval..........................

19 5.

GUIDELINES FOR PERFORMANCE AND DOCUMENTATION OF CODE ASSESSMENT STUDIES..............................................

20 5.1 Code Assessment Objectives.................................

20 5.2 Code Assessment Guidelines.................................

20 5.2.1 Evaluation of Experimental Data Uncertainty.........

20 5.2.2 Base Case Cal cul ati on...............................

21 5.2.3 Sensitivity Studies.................................

21 5.2.4 Nod al i zation Studi e s................................

21 5.2.5 Eval uati on o f the Code..............................

22 5.3 Information Required for Quantification of Codo Uncertainty................................................

22 5.4 Code Assessment Documentation..............................

27 5.4.1 Executive Summary...................................

28 5.4.2 Abstract............................................

28 5.4.3 Tabl e o f Con ten t s...................................

28 5.4.4 Introduction........................................

28 5.4.5 Facility and Test Description.......................

28 5.4.6 Code Input Model Description........................

29 5.4.7 Results.............................................

29 5.4.8 Run Statistics......................................

29 5.4.9 Conclusions.........................................

30 5.4.10 References..........................................

30 5.4.11 Appendices..........................................

30 5.5 Data Package...............................................

30 5.5.1 Code Input Model....................................

30 5.5.2 Calculated Data.....................................

30 5.5.3 Experiment al Data...................................

32 5.5.4 Factitty or Plant Description Document..............

32 6.

QUANTIFICATION OF CODE ACCURACY.................................

34 6.1 Overview of Code Accuracy Quantification...................

34 vi

6.2 Application of Quantitative Assessment Results.............

35 6.3 Acceptance Criteria for the Code...........................

35 TABLES 1.

Participating Countries and Codes...............................

3 2.

List of Designated Contact Persons for Participating Organizations...................................................

11 3.

Capability of the Code to Predict Phenomena.....................

23 4.

Run Statistics.................................................

25 5.

Key Parameters For Quantifying the Accuracy of the Code.........

26 6.

Minimum Requirements for Tape Description.......................

31 FIGURES 1.

International Code Assessment and A Management........................pplications Program 6

2.

Procedure for Error Corrections.................................

13 International Code Assessment and Ap 3.

Documents..........................plications Program 16 l

vii

PREFACE An International Code Assessment and Applications Program (ICAP) is being carried out by a number of countries and organizations and coordinated by the U.S. Nuclear Regulatory Commission (USNRC).

Its purpose is to sup+ ort the effort to obtain a considered view of the accuracy and validity of 'J5NRC thermal-hydraulic codes over their range of applicability, while suppesting possible improvements, as needed, to the codes. Quantitative motiods w'11 be used by several of the ICAP members to characterize the accuracy of the codes and code assessment activities within the international community will help support these methods. Coordination is proposed because of the recognized need to conserve resources throughout the international community by sharing the effort and benefit among participants. This document describes the procedures by which the coordinated international assessment program will be managed. This document is intended to be maintained in an active and current status.

l i

ix

i i

l ACKNOWLEDGEMENTS Credit is given to the following individuals who have contributed to the completion of the Guidelines and Procedures for the ICAP. At the Nuclear Regulatory Commission those persons are D. Bessette, P. Ting, L. Shotkin, F. Odar and P. Larkins. At the Idaho National Engineering Laboratory those persons are R. Hanson, G. Wilson and G. Case.

t i

i i

l l

Xj I

1.

INTRODUCTION Increasing numbers of light water reactors (LWRs) are becoming operational throughout the world.

It is generally recognized that sound management of this growing resource requires the development of advanced thermal-hydraulic computer codes for use in safety related studies.

Such codes enhance the ability to understand and predict the response of LWRs to postulated transients and breaks.

This common interest has led the United States Nuclear Regulatory Commission (USNRC) to organize an international cooperative code assessment and application program that is intended to:

o Support the efforts of the USNRC to determine the ability of the code to appropriately represent important physical phenomena and support the quantitative determination of code accuracy; o

Share user experience on code assessment and to present a well documented assessment data base; o

Share experience on code errors and inadequacies and cooperate in removing the deficiencies to maintain a single, internationally recognized code version; and o

Establish and improve user guidelines for applying the code.

The sharing of effort by the international nuclear community will allow these goals to be met through an optimum use of limited resources. The cooperative effort is planned to continue over a period of approximately five years beginning in 1985.

Towards these ends, the particisating organizations will share information relating to analysis motiods and code assessment activities.

In general, the USNRC will furnish its advanced, best-estimate l

thermal hydraulic codes, test data and code assessment results in exchange for code assessment studies and the experimental data necessary for code verification. Other product exchanges will be considered as specifically provided for in the individual agreements between the USNRC and program participants. Organizations with either signed or anticipated agreements and the codes being utilized are listed in Table 1.

The use of advanced thermal-hydraulic codes has been promoted by the increasing trend to perform best estimate analyses of transients and breaks.

Formerly, the tendency was to use prescriptive criteria and to insert conservatisms wherever uncertainty existed or information was judged to be lacking or imprecise. This approach to modeling was intended to ensure a " conservative" prediction of plant behavior. With the increased emphasis on small breaks and transients, however, the capability to accurately predict plant response becomes more important.

This is particularly true regarding operator procedures and training.

1

Use of an advanced, best-estimate code for safety analyses requires that the code accuracy be quantified through assessment over the range of applicability. Also required is a sound physical understanding of the-underlying reasons for its accuracy and limitations.

The USNRC has plans to replace its present 10 CFR 50 Appendix K LOCA/ECCS rule with a best-estimate approach and an evaluation of uncertainty. The USNRC plans to employ results from code assessment studies to provide conclusions relative to code accuracy and uncertainty.

In addition, the assessment results will be used to help define where future resources should be expended for experimentation and code improvement.

Program (gement of the International Code Assessment and ApplicationsICAP Mana Discussion of code management within this program is provided in Section 3.

Reporting and documentation of the program and information flow is presented in Section 4.

Section 5 discussed guidelines for performing and documenting code assessment studies. An overview of the plans for quantifying the code accuracy are described in Section 6.

This report revises the guidelines followed by the USNRC for thermal-hydraulic code assessment as described in NUREG-0676 " Plans for Assessment of Best Estimate LWR Systems Codes," 5. Fabic, P. Anderson, July 1981.

l 2

i

.I

TABLE 1.

PARTICIPATING COUNTRIES AND CODES Country Oraanization RELAP5 TRAC-PWR TRAC-BWR COBRA-TF Austria (1)

Austrian Research X

Center Siebersdorf Belgium Tractobel X

Brazil (1)

The Comissao X

X National De Energia Nuclear of Brazil Finland Technical Research X

Center of Finland France commissariat a X

X X

l'Energie Atomique F.R.

Federal Ministry for X

X X

Germany Research and Technology Kraftwerk Union Aktiengesellschaft Gesellschaft fur Reaktorsicherheit JRC-Ispra The Joint Research X

(1)

Center ISPRA Establishment of the European Atomic Energy Community Italy ENEA X

X X

Japan (1)

Japan Atomic Energy X

X X

X Research Institute Korea Korea Advanced X

X Energy Research Institute j

l Mexico (1)

Netherlands Netherlands Energy X

(1)

Research Foundation

{

Spain Consejo de X

X Seguridad Nuclear 3

TABLE 1.

(Continued)

Country Oraanization RELAPS TRAC-PWR TRAC-BWR COBRA-TF i

Sweden Swedish Nuclear Power X

X Inspectorate Studsvik Energiteknik AB Switzerland Swiss Federal X

X Institute for Reactor Research CCNAA Coordinating Council X

(Taiwan) for North American Affairs United United Kingdom Atomic X

X Kingdom Energy Authority Central Electricity Generating Board Nuclear Installations Inspectorate National Nuclear Corporation British Nuclear Fuels Ltd.

United Nuclear Regulatory X

X X

X States Commission Yugoslavia The Josef Stefan X

(1)

Institute of 4

Yugoslavia (1) Agreement Under Discussion i

4

2.

MANAGEMENT OF THE INTERNATIONAL CODE ASSESSMENT AND APPLICATIONS PROGRAM This section summarizes guidelines for management of the ICAP program.

In general, these guidelines conform to the individual agreements between the USNRC and-the other participants, however, the agreements are governing in the event of possible conflicting provisions. The significant relationships and responsibilities for management of the program are summarized in Figure 1.

- 2.1 Manaaement Structure and Relationshios 2.1.1 Proaram Coordination Program success and efficiency can best be achieved with the prime management functions focused in a single coordinator. As developer of the code and common signatory to the bilateral agreements, the USNRC has assumed the responsibility for code support and program coordination and integration.

Coordination and integration of the program. support effort for the quantification of code accuracy will be carried out by the USNRC and its contractors at U.S. Department of Energy (USDOE) laboratories with Idaho National Engineering Laboratory providing technical integration.

The USDOE is responsible for ensuring that contra:: tors perform all USNRC work within the provisions of their operating contract with the USDOE and that the work is delivered within the approved scope, schedule and funding. The USDOE-Idaho Program Manager or his designated representative for-the ICAP program will participate in the Program Group.

2.1.2 Proaram Manaaement Groun The purpose of the Program Management Group is to serve as a review and coordination body for ICAP. The intent is to have a sufficiently small i

group for effective interchange, typically one or two members for each participating organization.

The terms of reference of the Program Management Group include discussion of:

The plan of work of the respective organizations for the coming o

year, e.g., assessments to be performed; o

From an overview perspective, the status and performance of the frozen code and work.on the next code version; o

The assessment plan and status of the assessment effort; o

Results from Task Group and Specialist Meetings; o

Program documentation, including the code and its documentation, user guidelines, newsletters and assessment reports; and 5

Thermal-Hydraulic Rights and Exchange Agreements obligat. ions Technical direction Program Group responsibility for coordinated program Other groups, as needed

't ir Code Assessment Task Specialist Meetings Groups Figure 1.

International Code Assessment and Applications Program Management.

NSL00515

l 0-Procedures for support to the.qua'ntification of code uncertainty.

The Program Management Group will meet at least once per year and may meet more often at the discretion of its members.

Locations for the 4

meetings may be divided between the United States and countries of other program participants. The Chairman will be provided by the USNRC.

It is not the intention of the USNRC to dominate or necessarily lead the discussion of 4

the group, rather, each participant has equal voice.

Consensus views on points of discussion will be sought, wherever possible. The USNRC will i

strongly consider the recommendations of the group in prioritizing its allocation of resources for code maintenance and improvement.

i 2.1.3 Task Group A Task Group will meet to resolve specific issues as decided by the Program Management Group and issue written recommendations. The, intent is to bring together those specialists actively involved in experimentation and modeling to share information and reach a common understanding relative to specific tasks. Membership of the Task Groups and attendance at meetings may depend on the particular tasks to be addressed.

Each participating country represented in the Task Group has equal representation within the group. The Task Group will meet as often as-the Program Management Group deems necessary at locations in participating countries. The following are the principal tasks that must be carried out. These tasks may be terminated or new ones created depending on the progress made or problems that may arise:

1.

Code Changes. On a regular basis, the Task Group will meet to discuss:

o Errors discovered, priorities for error corrections, error

)

corrections implemented, input / output and user conveniences

-)

l for the frozen code version; o

Model deficiencies and priorities for model improvements for i

the next code version-1 o

Noding studies; o

Implementation and run time.exper'ence; o

Newsletter; and o

Code documentation.

2.

Assessment Reports.

On a regular basis, the Task Group will meet to discuss nonproprietary assessment reports.and the review of these reports performed by the USNRC.

Discussion will include the qualitative and quantitative assessment carried out by the USNRC, with the objective being to provide a peer review and recommendations.

7

1 3.

Model Development and Supporting Experimental Work. The Task Group will meet as needed to discuss specific code model L

deficiencies (e.g., post-CHF heat transfer, two-phase flow),

. supporting experimental work, and modeling for implementation in a later code version.

4.

Plant Applications. The. Task Group will meet as needed to discuss plant application studies including noding and sensitivity.

studies, plant modeling, and results from application of.the ccde to startup tests and plant transients.

1 2.1.4 Soecialist Meetinas i

Specialist Meetings will be held, as decided upon by the Program Management Group, at locations in participating countries.. The purpose will be to bring together code users for presentation of assessment results,-both qualitative and quantitative, and exchange information on user experience.

There will be at least one such meeting per year.

1 2.2 Resoonsibilities of Proaram Particioants 2.2.1 United States Nuclear Reaulatory Commission-(USNRC) 4 The USNRC will have the responsibility and provide the resources for:-

1.

Provision of the code and its documentation; 2.

Consultant service and troubleshooting according to. agreements; 3.

Implementation of code error corrections and enhancements as j

recommended by participants, but according to the schedule and i

priorities established by technical. and safety-needs and available j

1 USNRC resources; 4.

Development, maintenance and issuance of a quarterly Newsletter for each code; 5.

Composition and issuance of the program documentation (see Section 4);

6.

Coordination of data supporting the quantification of code accuracy; i.

L 7.

Providing USNRC and contractor staff to the groups identified in Section 2.1; and 8.

Providing such staff for other functions in accordance with the individual agreements between the USNRC and participants.

1 8

~-

b 2.2.2 International Particioants The responsibilities of each participant are defined in its agreement with the USNRC. Generally, the agreements provide for the-following responsibilities and resource allocations by each participant:

1.

Performing code. assessment studies according to the agreement.

The guidelines by which the studies will be conducted are described in Section 5; 2.

Issuing code assessment reports in English. The content and format of the reports are described in Section 5; and 3.

Providing experimental and calculational data used in the code assessment studies necessary to evaluate the studies, to support j~

quantification of code accuracy and to effect code improvements.

The necessary forms of information transmittal are covered in Section 5.

i In addition to the above responsibilities, participants should send representatives to the Program Management Group, appropriate Task Group and-

[

Specialist Meetings identified in Section 2.1.

}

2.3 Responsibilities of Contact Persons 2.3.1 United States Nuclear Reaulatory Commission (USNRC)

The USNRC Program Manager will be _ responsible for execution of the bilateral thermal-hydraulic exchange agreements. All correspondence

~

l concerning the use of the code should be sent to the USNRC. Program Manager-including errors noted, requests for user assistance and assessment i

reports. The USNRC Program Manager will work with the responsible USNRC.

contractor to ensure that appropriate, timely responses are provided to notifications of errors and requests for user assistance.

The USNRC Program Manager will have oversight responsibility for the issuance of Assessment Report Reviews, Newsletters, Topical Reports and support to code uncertainty quantification.

The Program Manager will also organize and attend Program Group, Task Group and Specialist Meetings of-code users. Correspondance to the USNRC Program Manager is to be sent to the following address:

ICAP Program Manager Reactor and Plant Systems. Branch Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washingto:. D. C.

20555 Telephone:

(301)-427-4920 Telex Number: 908142 NRC BHD WSH l

A second copy of technical correspondence should also be sent directly to the USNRC contractor. responsible for the code concerned.

The USNRC i

9

r

~

contractors will assist the USNRC in carrying out the program at the direction.of the USNRC, and will attend and participate in all. appropriate meetings. The responsible individuals are as follows:

TRAC-PWR:

Rick Jenks Mail Stop K555 Los Alamos National Laboratory Post Office Box 1663 Los Alamos, New Mexico 87545 Teleph'ne:. (505) 667-2021.

o Telex Number: 9109881773 LOS AL LAB TRAC-BWR, Robert Hanson.

RELAP5, and EG&G Idaho, Incorporated, TSB COBRA-TF:

Post Office Box 1625.

1 Idaho Falls,-Idaho 83415-i i

Telephone:. (208) 526-9701 4

Telex Number: 9105775915'USDOE IDAH 2.3.2 International Particioants Each participant should designate an individual to be responsible for c

execution of its bilateral thermal-hydraulic exchange agreement within the appropriate organization (s). An alternate may also be designated. - All correspondence concerning the use of the code will be sent through the designated contact. This includes errors noted, requests for user assistance,-assessment reports, data packages,-..etc. The USNRC-will send project documents including Assessment Reports,. Newsletters and Topical Reports to the designated contacts, who will be responsible for further distribution within their organization or country..The designated-contacts l

will also receive notification of all Program Group meetings, relevant Task l

Group meetings and Specialist Meetings of code users. The. designated contacts or their alternates should attend Program Group meetings. Table 2 provides a list of individuals serving as designated contacts.

2.4-Protection of Information-The purpose of this program is to further the knowledge _and understanding of the participants in the validation of thermal-hydraulic computer codes.

With due protection of information that is proprietary, i

confidential or privileged, information will flow freely among the participants.

Participants and their contractors are responsible for the protection 4

of proprietary, confidential or privileged information both within and outside the_ program.

It shall be the responsibility.of the originating party to clearly identify and mark documents containing proprietary, confideni.ial or: privileged information so that such information can be-protected from disclosure.

1 10 l

TABLE 2.

LIST OF DESIGNATED CONTACT PERSONS FOR PARTICIPATING ORGANIZATIONS-Country Contact Oraanization Belgium Dr. E. Stubbe Tractebel Finland Mr. H. Holmstrom Valtion Teknillinen Tutkimuskeskus France Dr. M. Reocreux Institut De Protection De Surete Nucleaire F. R. Germany Prof. E. Hicken Gesellschaft Fur Reaktorsicherheit Mr. F. Winkler Kraftwerk Union Aktiengesellschaft Italy Mr. G. Saponaro ENEA-DISP Japan Dr. K. Sato Japan Atomic-Energy Research Institute Korea Dr. Sang Hoon Lee Korea Advanced Energy Research Institute Multinational Dr. H. Stadtke Commission of the-European Communities Joint Research Center ISPRA Spain Dr. J. Decarlos Consejo De Seguridad Nuclear Dr. J. Izquierdo

'Consejo De Seguridad Nuclear i

i Sweden Dr. O. Sandervag Studsvik Energiteknik AB i

Taiwan Dr. Y. Chen Institute of Nuclear Energy Research The Netherlands Dr. J. Speelman Energieonderzoek Centrum l

Nederland United Kingdom Mr. J. Fell United Kingdom Atomic Energy Authority

~

l United States Dr. N. Lauben United States Nuclear Regulatory Commission l

11

3.

PROCEDURES FOR CODE MANAGEMENT 3.1 Freezina of.the Code for Assessment and Anolication A principal intention of ICAP is to maintain a standard, internationally recognized code version.. To accomplish this goal, changes to the code must be properly managed. Code assessment efforts are hindered when a code is undergoing continuous development. The code must, therefore, be frozen, documented and distributed to code users so that all users have the same code, and assessment results and user experience can be exchanged knowing that results are interrelated and are not specific to a unique code version.

Freezing of the code is defined as the avoidance.of code development whereby models and correlations are changed to improve the code predictive l

capability. Changes to the frozen code are allowed to correct errors, and for improved input / output and user conveniences.

The intent is to freeze each code for a sufficient period of time to be able to establish a considered view of its capability and accuracy over its range of applicability. The current frozen versions are as follows:

TRAC-PF1/ MODI Version 12.1 RELAP5/M002 Cycle 36 l

TRAC-BF1 Version G1J1 i

3.2 Procedure for Error Corrections The procedure for correcting errors is shown in Figure 2 and described in this section.

If a participant discovers an error, the information should be sent to the USNRC Program Manager with a copy to the responsible USNRC contractor (see Section 2.3.1). The problem should be described and suggestions for possible fixes may be included. The problem will be reviewed by the USNRC and its contractor to ensure that it is indeed an

+

error and that the problem is relevant to conditions that might conceivably be expected to occur in a power plant. The USNRC and its contractor will correct the problem, within the limits of its available resources and priorities.

Error corrections will result in code updates to the frozen version which will typically be released quarterly.

News of the error and i

i associated resolution will be included in the next issue of the code newsletter. This includes errors discovered through use of the code within the United States.

3.3 New Code Versions The use of the code for independent assessment and applications can be expected to reveal deficiencies that need to be addressed through code development. The quantitative and qualitative assessment of the code should be particularly valuable in defining code adequacies and inadequacies.

The information generated during the period when the code is kept frozen will be.

considered continuously and collectively in preparing new versions of the code.

l 12

Error Corrections Participant Informs USNRC and INEL/LANL of Error y

j INELILANL Reviews the Problem y

if Significant Resources Are Required (e.g., a 1 Man-Week),

O INELILANL Will Consult With USNRC Before Proceeding l

u y

if Error Deemed Lower Priorty-Fix is Provided to Sender Upon Set Aside and Priorties Resolution of Error, Fix is Discussed at Next ICAP Meeting Provided to Other Participants as Part of Quarterly Newsletter USNRC Maks Final Decision Figure 2.

Procedure for error corrections.

,, g,

The USNRC will maintain a list of all code revisions suggested.in the assessment process and provide priorities for their implementation. The list and associated documentation will form a basis for review by the Program Group, which may provide recommendations for reprioritization.

i Model improvements will be made in parallel to the assessment of the frozen code, according to priorities and available USNRC resources.

User requirements to resolve safety and regulatory needs is the foremost determinant of priorities. The new version of the code will be issued to all participants using that code.

International participants may produce suggested code enhancements resulting from their code assessment studies and experimental and modeling work.

Participants may provide new or improved models or correlations. The USNRC will make use of enhancements. and data supplied by participants in preparing new code versions.

Keeping in mind the intention that there shall be an officially i

released, documented version of the code such that all users are working with the same code, the participant supplying enhancements must indicate whether the enhancements should not be incorporated into a new code version because the information is considered to be proprietary, confidential or privileged.

In this event, such enhancements cannot be incorporated in an official version of the code.

14

\\

. -....~

i i

4.

REPORTING AND DOCUMENTS To meet the goals of ICAP, a well designed and conducted documentation j

effort is necessary. This section defines the required documentation of-l program information. The major program documents are summarized in Figure 3.

When activities are specified to be carried out by the.USNRC, the USNRC itself or USNRC contractors including the Idaho National Engineering Laboratory (INEL), Los Alamos National Laboratory (LANL) and Sandia National Laboratory, will perform the activities.

4.1 Distribution of Information 1

l All program documents will be available to the USNRC. The USNRC may publish Assessment Reports prepared by participants that do not contain proprietary, confidential or privileged information as NUREG/IA reports, with proper credit to the originator.

Documents containing proprietary, 4

confidential or privileged information shall not be published or distributed i

by the USNRC. Data Packages, whether proprietery or nonproprietary, shall

}

not be published or distributed by the USNRC.

i The following documents shall have unrestricted distribution to the i

program participants:

~

Guidelines and Procedures (including assessment plans and o

associated matrices);

1 o

Executive Summaries of Assessment Reports; i

i o

Nonproprietary Assessment Reports; o

USNRC reviews of Assessment Reports; o

Newsletters; and

}

o Topical Reports.

If an assessment report will contain proprietary, confidential or i

privileged information, the _ participant may prepare the assessment report, i

if possible, with a view to having the main body of the report as unrestricted and having sensitive information in an appendix.

In this case, j

the main body of the report may be published by the USNRC with proper credit to the originator and would be given unrestricted distribution within the program while the appendix would not be distributed.

Proprietary assessment i

reports will not be published or distributed by the USNRC.

1 4.2 Code and Related Documentation i

l The USNRC will provide to each participant entitled to receive the information the code and accompanying documentation, including the code i

structure, documentation and discussion of models, correlations and numerics, developmental assessment and user guidelines.

Included are code updates and new code versions that may result during the course of the ICAP 15 L.

i i

USNRC Code and its Documentation Program Group Program Group Phenomenologically Based Guidelines for Performing and j

Validation Matrix Documenting Assessment I

Participants I

Assessment Reports Executive Summaries Data Packages Facilities Descriptions

~m User Guidelines USNRC Assessment Report Reviews User Guidelines Newsletter improved Code Documentation USNRC and Program Group Special Experimental Overall Assessment Studies & Documentation.

of. Code Capability l

Through Topical Reports User Guidelines l

l New Code Version and its Documentation Figure 3.

International Code Assessment and Applications Program documents.

NSL00517

i

)

i l'

program. Normally, one copy of the code will be provided to each participant, who is then responsible for copying and providing the information to other users within that participant's organization or country that are entitled to receive the code. As part of the assessment effort, l

participants should indicate improvements needed to the code documentation.

4.3 Code Assessment and Validation Matrices j

This is an active plan summarizing the current direction to be followed j

in the conduct of the program to achieve its goals.

First, a matrix (shown in the Appendix) will be maintained which will present the current l

activities of the international participants. Secondly, a set of matrices will be maintained which focus on the broad needs for code assessment and i

validation for the thermal-hydraulic codes.

These needs will reflect the current status of the codes through regular update to the matrices given in the Appendix (the validation are a refinement of the CSNI matrices for the j

range of transients in PWR and BWR facilities). The validation matrix will be updated annually.

4.1 Assessment Reports. Executive Summaries and Data Packaoes I

Participants conducting assessment studies will document those studies in assessment reports and associated data packages.

Participants should i

prepare an Executive Summary for each assessment report, which will be openly distributed by the USNRC to all participants.

Executive Summaries i

should not, therefore, contain proprietary, confidential or privileged information.

Facility and plant descriptions sufficient to construct input-decks may be provided as part of the data package to assist the USNRC review and 4

i evaluation of code assessments and to effect code error corrections and j

enhancements. The USNRC may request such information on a case-by-case basis whera needed to evaluate the code assessments.

Provision of the facility and plant description documents is the responsibility of the -

participant providing the associated assessment report. A single j

transmittal and/or minor updates may be sufficient for a series of -

l assessment reports based upon the same experimental facility or plant.

i The procedure for sending assessment reports, executive summaries and data packages is as follows:

l 4

o Assessment reports and executive summaries for RELAP5-and 1

TRAC-BWR: One copy each to the USNRC program manager and the INEL

]

program manager.

l o

Assessment reports and executive summaries for TRAC-PWR: One copy each to the USNRC program manager, the INEL program manager and the LANL program manager.

i o

Data packages for RELAP5 and TRAC-BWR:

One copy to the INEL program manager.

o Data packages for TRAC-PWR: One copy to the LANL program manager.

l 17 1

Further information on guidelines for performing and documenting code assessments is given in Section 5.

4.5 USNRC Review of Assessment Reports The USNRC will undertake to review each assessment report and its executive sumary. The reviews will be documented in concise evaluation-summaries.

Prior to publication of an evaluation summary, the participant providing the assessment report will have the opportunity to review and comment on the draft evaluation sumary.

The final evaluation summary will be distributed to all participants, therefore,- they will not contain proprietary, confidential or privileged information.

The assessment reports will be reviewed by the responsible USNRC contractor, INEL in the case of RELAP5 and TRAC-BWR, and LANL in the case of TRAC-PWR. The primary objectives of the review of assessment reports is to ensure that the results of code assessments are fully understood and assimilated by the code developers and that any questions regarding the data used or how the code was applied are resolved. Additionally, the review will serve to integrate the general body of knowledge developed from all assessment results.

4.6 Newsletter Service For timely information flow to all program participants, a newsletter service will be provided by the USNRC. The newsletters will be issued quarterly and will contain information of general interest to the program.

A separate newsletter will be issued for each code to users of that code.

Participants are welcome,to pro' vide input for incorporation in the newsletter. Contents of the newsletters will include:

Recently identified code errors and corrections (updates);

o o

Schedule for error corrections to be made; o

Executive summaries and USNRC evaluation summaries of assessment reports; Planned model improvements and schedule for the next code version; o

o Recommended modeling techniques and user guidelines; o

Improved input / output and user conveniences; o.

Upcoming meeting notices; o

Bibliography of code usage, etc.

It is expected that from time to time participants may encounter errors or problems in running the code.

In such cases, the participants should notify the USNRC Program Manager, who will ensure that a satisfactory resolution is provided within the limitations of priorities and available 18

resources. News of such difficulties and their resolution will be provided to all participants through the newsletter service. This includes any code updates that may result.

4.7 Tonical Reports Certain agreements may contain provisions for specific research.

In addition, certain program activities may be of sufficient depth and extent to warrant special consideration.

Documentation of such efforts, l

particularly those conducted by Task Groups, will be provided through special topical reports. The development, composition, publication and issuance of topical reports will be considered on a case-by-case basis.

At times appropriate to the accumulating assessment data base (approximately annually), the USNRC together with the Program Group will evaluate the significant findings of the assessments and support to i

quantification of the code accuracy. Results and conclusions will be documented and published in topical reports. These documents will be available to all participants, therefore, they will not contain proprietary, confidential or privileged information.

4.8 Information Storaae and Retrieval INEL will operate an information storage and retrieval system for RELAPS and TRAC-BWR. The system will contain: newsletters, executive summaries of assessment reports and USNRC evaluation summaries of assessment i

reports.

It may also contain information on code errors, corrections and code updates. The INEL system will utilize an IBM PC accessible by phone.

Details of the system and access may be obtained by contacting the INEL ICAP 4

program manager. Similarly, LANL will operate an information storage and retrieval system for TRAC-PWR utilizing a VAX computer accessible by phone.

Details of the system and access may be obtained through the LANL TRAC user contact.

I r

f l

l

}

l 19

t 5.

GUIDELINE 3 FOR PERFORMANCE AND DOCUMENTATION OF CODE ASSESSMENT. STUDIES I

Objectives and guidelines for performing code assessments are presented l

in Sections 5.1 and 5.2.

Key assessment parameters are defined and the information required to quantify the code uncertainty is specified in Section 5.3.

Documentation requirements are provided in Sections 5.4 and 5.5..

1 5.1 Code Assessment Obiectives i

The primary objective of code assessment is to formulate well-supported judgements relative to code performance. This includes:

the ability of the code to physically represent-important phenomena; the quantification of code accuracy; recommendations for user guidelines, particularly nodalization; providing feedback to the code developer for suggested code improvements; 4

and providing feedback concerning the code documentation.

Code assessments should report conclusions, recommendations (when applicable) and information i

for evaluation of the code accuracy.

In addition to clearly supported j

conclusions derived from a code assessment, the reporting of perceptions of the assessor is encouraged, however, perceptions should be clearly indicated as such.

4 A code assessment, of necessity, consists of a code calculation.for which qualified experimental data exist.

Comparison of the calculated and measured response provides irsights into the capabilities of the code. A l

code assessment consists of a base case calculation, and may also include sensitivity studies to further evaluate code performance. All sensitivity studies should be reported to ensure maximum benefit of the assessment results.

1 5.2 Code Assessment Guidelines l

5.2.1 Evaluation of Exoerimental Data Uncertainty The assessor must evaluate and report the uncertainty of experimental data used for code assessment. This uncertainty has the following sources:

1 o

The distribution of individual measurements about the mean for a given node of the calculation input model (e.g., thermocouple measurements in the core, where the differences may result from i

three-dimensional flow effects, spacer grid effects, etc.);

I o

The effect of measurement location (e.g., measurements of clad temperature may be influenced by a thermocouple fin effect; measurement of hot leg fluid temperature may be influenced by a i

hot wall or cold wall effect; measurement of fluid density may be influenced by the location of the densitometer;-etc.);

i l

0 Limitations in measurement capability (e.g., dead bands in turbine flow meters where the instrument cannot measure below a certain I

flow rate);

20

i i

i o

Experimental boundary conditions (e.g. experimental facility heat i

losses and distributions, heat input from heat tracing, valve leakage,etc);

o Instrument uncertainty and signal processing, as determined by l

instrument calibration.

Depending on the type of measurement, one or more effects may dominate the determination of experimental data uncertainty.

For temperature, the effects of measurement location and the distribution of individual measurements resulting from three-dimensional effects are important. The l

assessor must provide a mean value for the node being compared with the code calculation, and a 1-sigma value of the standard deviation.

Data should not be used if they are suspect or if their uncertainty is indeterminate.

Obviously, this includes such examples as quantities beyond the instrument i

range, broken or uncalibrated instruments, and signals known to be in error.

5.2.2 Base-Case Calculation r

l In performing the base case calculation, the user must use best-estimate techniques and recommended code options to provide an objective survey of the code. A best estimate should be made with respect to nodalization. Recommended options from the code users manual should be i

adopted and identified. The base case calculation must be performed with the formally released code version.

In all cases-the facility model and code version must be fully documented.

5.2.3 Sensitivity Studies In addition to the base case calculation, sensitivity studies are needed to develop user guidelines. Sensitivity studies may explore the effect of input modeling, boundary conditions or code options (e.g., loss coefficients).

Sensitivity studies.may also be performed to study the effect of code model modifications. These are intended to explore the reasons the code results were obtained and to suggest possible enhancements for incorporation in a future version of the code. Whereas sensitivity studies are valuable in elucidating the code performance, mere tuning of the code is to be avoided. The results of the sensitivity studies must-be reported as additional analyses to further explore code performance and i

I should include purpose, modifications made, and-results.

5.2.4 Nodalization Studies-Nodalization studies should be performed.

Proper nodalization can be crucial to obtaining good results. Often, a facility model is adopted and an input deck is established and remains fixed for a.large number of calculations that may include a range of conditions.

Sufficient attention must be given to studying the sensitivity of the calculation.to nodalization. When nodalizing experimental facilities (especially basic and separate effects) the noding detail should be similar in general to typical power plant analyses. That is, highly detailed noding is generally irrelevant if comparable noding is not likely to be used for plant t

21

e I

l analyses. Studies using detailed noding.are encouraged, however, to determine the effect of noding sensitivity. The nodalization studies will permit improved user guidelines and will help to define the user-uncertainty.

l 5.2.5 Evaluation of the Code -

In' evaluating the. code, first the assessor should study the experimental data and understand the phenomena that occurred. Second, the code calculation should be studied to verify whether the code predicts the same phenomena.

Discrepancies between the experimental data and code calculations should be explained, areas of agreement noted and conclusions drawn on code i

capabilities and limitations. Table 3 presents a list of important phenomena for LWR transients and LOCAs. The code should be evaluated with respect to relevant phenomena from the table for each assessment case i

performed.

1 i

The assessor must keep in mind the importance of the variability of experimental data.

For example, the average of-several. thermocouple readings in a volume is applied when comparing the code-calculated temperature for the volume. Only when the uncertainty and variability of the experimental data is considered can the code be properly evaluated and i

conclusions drawn.

Particular attention should be given to the effect of:

structural heat and heat losses, as well as boundary conditions.

Atypicalities of the experimental facility must be remembered.

For example, i

electrical heater rods are generally a poor simulation of nuclear rods with-respect to stored energy and thermal conductivity.

The computational efficiency of the. code should be evaluated and' reported, including run statistics identified.in Table 4.

Also,. identify whether the calculation time step was determined by the~ code due to Courant or other time step limits or whether the calculation proceeded at a. user specified maximum time step and thereby could have proceeded at a faster i

rate. The time step evaluation may be presented by providing a comparison of the actual time step and the user specified maximum time step, both as a i

function of transient time.

4

[

The user should evaluate the code documentation, including-the user i

manual, user guidelines, documentation of code models, correlations and j

numerics and the developmental assessment.

Deficiencies in the j

documentation should be noted along with recommendations for improvements.

5.3 Information Reauired for Quantification of Code Uncertainty i

Code assessment activities contribute to an improved code,. improved code documentation, user guidelines and an improved user interface.

j However, in addition, code assessment provi, des a base of data that can be used to support the quantification of code uncertainty.

j The ICAP has the charter to support the various uses of code assessment data as itemized above. A list of key parameters, shown in Table 5, has been defined for use in quantification of code accuracy. The table includes 4

4 i

22

f TABLE 3.

CAPABILITY OF THE CODE TO PREDICT PHENOMENA Large Small PWR Phenomena B.tggk B.tagh Transient Break Flow and Valve Leak Flow (subcooled and saturated)

X X

X Phase Separation in T-Junction and Effect on Break Flow X

Liquid Inventory Distribution X

Phase Separation X

X l

Mixing and Condensation During ECC Injection, Including Thermal Stratification X

X ECC Bypass and Penetration X

Steam Binding (liquid carry-over, etc.)

X X

Core-Wide Void and Flow Distribution X

X Entrainment and Deentrainment in Core X

X Entrainment and Deentrainment in Upper Plenum X

X CCFL at Upper Tie Plate and Pool Formation in Upper Plenum X

X Mixture Level in Core X

Mixture Level in Downcomer X

X l

Core Heat Transfer, Including Partially Covered Core (DNB, dryout, rewet)

X X

Quench Front Propagation X

X Single Phase Natural Circulation X

X l

Two Phase Natural Circulation X

X l

Natural Circulation Through Vent Valves (B&W)

X X-l Stratification in Horizontal Pipes X

Reflux Condenser Mode and CCFL X

Boiler Condenser Mode (B&W)

X Noncondensible Gas Effects X

Asymmetric Loop Behavior X

Loop Seal Clearance X

Primary Side Steam Generator Heat Transfer X

X Secondary Side Steam Generator Heat Transfer X

X Mixture Level and Entrainment in Steam Generator X

One and Two Phase Pump Behavior X

X X

Pressurizer Thermal-Hydraulics X

X Surgeline Hydraulics X

X Refill of Loops (B&W)

X Thermal-Hydraulic Nuclear Feedback X

Boron Mixing and Transport X

Separator Hydraulics X

X 3

23

T A

I TABLE 3.

(Continued)

BWR Phenomena 1&CA Transient Break Flow and Valve Leak Flow (subcooled and saturated)

X X

Core-Wide Void and Flow Distribution, Including Channel and Bypass Axial Flow and Void Distribution X

X Parallel Channel Instabilities X

X Phase Separation X

Mixing and Condensation During ECC Injection X

ECC Bypass and Penetration X

CCFL at Upper Tie Plate and Pool Formation in Upper Plenum X

X CCFL at Channel Inlet Orifices X

Lower Plenum Flashing X

Steam Binding (liquid carry-over, etc.)

X Core Heat Transfer, Including Partially Covered Core (DNB,dryout,rewet)

X Quench Front Propagation on Fuel Rods and Channels X

Entrainment and Deentrainment in Core X

Deentrainment at Upper Tie Plate and Upper Plenum X

One and Two Phase Pump Behavior, Including Jet Pumps X

X Single Phase Natural Circulation X

Two Phase Natural Circulation X

X i

Mixture Level in Core X

X Downcomer Mixing and Mixture Level in Downcomer X

ECC Mixing and Condensation X

Spray Distribution and Spray Cooling X

Phase Separation in T-Junction and Effect on Break Flow X

X Boron Mixing and Transport X

Steam Line Dynamics X

Separator Hydraulics X

X Steam Dryer Hydraulics X

j Nuclear Thermal-Hydraulic Feedback and Instabilities X

1 Void Collapse During Pressurization X

g j

i i

j 4

1 24

TABLE 4.

RUN STATISTICS o

Required plots are: CPU vs. RT and DT vs. RT 3

o Required number is:

(CPU x 10 ) x (C x DT)

Transient Time Where RT

=

Total number of volumes in the model C

=

Total number of time steps DT

=

CPU = Total execution time j

o Specify type of machine used to perform the calculation i

l 25

?

-,p.,

m

TABLE 5.

KEY PARAMETERS FOR QUANTIFYING THE ACCURACY OF THE CODE Applicable to Key Parameter EH1 BE1 Primary system pressure X

X Primary system break and/or valve flow X

X ECC injection flow rate (each operative system)

X X

Vessel or core collapsed liquid level X

X Core cladding temperature at 1/4,1/2,3/4 and peak power region X

X Core inlet mass flow rate X

X i

Nuclear core power (reactivity transients only)

X X

Pressurizer liquid level X

Secondary side pressure

~X Secondary side break and/or valve flow X

Steam generator primary and secondary liquid levels.

X Hot leg mass flow rate X

Cold leg mass flow rate X

Steam line and recirculation loop flow rates X

Sinale Values Blowdown peak cladding temperature X

X Reflood peak cladding temperature X

X Minimum core liquid level X

X Maximum or minimum primary system pressure X

X Peak core power (nuclear simulation only X

X Maximum or minimum secondary side pressur)e X

Times of core uncovery X

X Times of CHF at the cladding hot spot X

X Times of peak cladding temperature (blowdown and reflood, orother)

X X

Time to final core quench X

X Time to rewet and/or quench at the hot spot X

X Times of ECC initiation (each operative system)

X X

Time of MSIV signal generation X

X Time of loop seal clearing (i.e. time of first significant vapor flow through seal)

X

-X Time when primary pressure is less than steam generator pressure X

Time to pressurizer empty or full X

Times of pressure maxima and/or minima (primary and secondary)

X X

26

both ' single and continuous valued parameters, with the single-valued parameters generally representing event timings or maximum or minimum values of the continuous valued parameters. These parameters will characterize the '

ability of the code to calculate the response observed in an experiment. The following general notes apply to the table.

o Not all parameters will be applicable to each transient.

o Liquid levels are derived parameters generally based on.

differential pressure measurements.

It is preferable that i

differential pressures be reported rather than liquid levels.

If i

liquid levels are reported, the' exact method by which they are i

derived must be specified.

o Flow rates (break', valve, core, etc.) should be reported in terms of mass. The method by which each parameter was derived should be clearly stated. The flow area used with each parameter must be given.

I o

All key parameters included in a data transmittal must be clearly related to their geometric location in the code model and the l

experimental facility.

For the purpose of support to the quantification to code uncertainty, 4

participants should supply suitable data for the applicable key parameters shown in Table 5 for base case and. sensitivity studies. _ Determination.of:

the quantitative differences between the code and measured results requires 4

information transmittal in an appropriate form.

Continuous valued plots normally provided in assessment reports are unsatisfactory for the detail i

necessary to perform uncertainty analyses.

Instead, the qualified data from the experiment should be provided for the applicable key parameters either on magnetic tape, floppy disk or other suitable electronic means. The l

single-valued parameters should be presented in the form of a table.-

There are special considerations when redundant and/or multichannel measurements exist for a key parameter in an experiment. An example is the i

case of several thermocouples that are combined to provide a volume average l

cladding temperature corresponding to a particular node in the code calculation.

In such cases, all experimental measurements should be-included in the data transmittals.

Provision of this information will support the determination of the experimental data variability contribution to the overall uncertainty. Additionally, the measurement uncertainty should be provided for each key parameter, including derived parameters.

5.4 Code Assessment Documentation I

The usefulness of code assessment is strongly affected by the degree to which the documentation of the study is complete and concise.

The following provides guidelines #or the documentation of code assessments and describes sections that should be included and their contents.

l l

l 27

_ _ _ _ _. _ _ _.. _ _. ~ _ _

l l

5.4.1 Executive Sumarv An executive sumary should be supplied which discusses the objectives, scope, methodology used, conclusions and recommendations. The discussion should include:

the ability of the code to represent important physical i

phenomena, the code accuracy; recommended code improvements, proposed enhancements to the code; and recommendations concerning user guidelines and nodalization.. The sumary should also include run statistics information identified in Table 4. Proprietary, confidential or privileged information should not appear in the sumary since it will be distributed to all program participants.

5.4.2 Abstract The abstract should contain a brief description of the contents of the 4

i document and the sponsoring and performing agencies.

The code, experimental 1

facility and tests should be identified. Results, conclusions and recommendations should not be included in the abstract.

i

)

5.4.3 Table of Contents The table of contents should identify sections of the report and include lists of tables and figures.

5.4.4 Introduction The introduction should include a detailed discussion of the assessment study background, scope and objectives, and should present the assessment methodology used for the study. A brief description of sections to follow in the document may be helpful to the reader.

5.4.5 Facility and Test Description A brief discussion should be provided of the experimental facility or plant including its geometric layout, instrumentation, operational procedures and other information, as required for the reader's 3

understanding.

Reference may be made to detailed facility or plant and test description documents to be part of a data package that may accompany the assessment documentation (see Section 5.5). A single facility and test description document may cover a series of experiments. Transmittal of such i

documents need only occur once when the first assessment study in the series i

l 1s transmitted; however facility / test features unique to each assessment 3

study should be described in the assessment document. The.information necessary to recreate the input deck may be included as part of a data package to accompany the assessment document (see Section 5.5).

li The experiment to be calculated should be discussed including important thermal-hydraulic information, initial and boundary conditions, and operational information pertinent to the calculation.

Measurement uncertainty must also be discussed.

a 28 4

r

.,,_,.,~

_,,,.r_

,,m,

.__._m

.c e

m..---

5.4.6 Code Inout Model Description The code input model should be discussed in detail including nodalization, assumptions, boundary and initial conditions and operational conditions for the calculation. The nodalization diagram should be i

presented along with a discussion of the nodalization rationale, including assumptions and modeling compromises. Modifications to the input model or code for sensitivity studies should be discussed.

5.4.7 Results Results of the base case calculation that lead to major conclusions should be clearly presented and discussed. Applicable assessment parameters from Table 3 should be discussed. The rationale for performing any sensitivity studies should be discussed along with the methodology used to perform them. Modifications to base case conditions and the resulting l

effect should be fully described and qualified.

i The discussion of base case and sensitivity results should include:

o A comparison between the code prediction and the experiment with regard to the important physical phenomena that occurred during the experiment; I

o The accuracy of the code with an explanation of the reasons for differences between the data and calculation. The accuracy discussion should include key parameters from Table 5; o

Conclusions from sensitivity studies; i

o Suggestions for improved models and correlations or for additional models of features that should be added to the code;-

o User guidelines for performing similar analyses; and o

Suggestions for improving input / output features and users conveniences.

Assessment parameters should be overlayed with appropriate experimental results. A discussion should be included if the code fails to provide user flexibility to model certain phenomena or simply fails to predict phenomena.

The applicability of the results to full scale power plants should be discussed. Note whether the observed phenomena are likely to occur in a full scale plant.

5.4.8 Run Statistics A discussion of run statistics should include those listed in Table 4 and a discussion of the time step behavior as described in Section 5.2.5.

r 29

5.4.9 Conclusions s

A summary of major conclusions and recommendations derived from the code assessment study should be presented. Supportive discussions in the body of the document may be referred to. Conclusions and recommendations not supported by discussions in the body of the document are inappropriate.

5.4.10 Egferences All drawings, test conditions, and other information required to construct the input deck and perform the calculation and analysis should be referenced.

5.4.11 Anoendices Appendices should be included to supply support information necessary to ensure document completeness, including proprietary, confidential or.

privileged information, which will be protected from disclosure by the USNRC and its contractors.

5.5 Data Packaae Participants should provide the USNRC with a data package to accompany the code assessment document if such information is normally prepared and available. The USNRC may specifically request data packages on a case-by-case basis if additional information is required to evaluate the code assessment work. Data packages should include: the code input listing; all calculated data from the study; all experimental data for the experiment; and a detailed description of the facility in which the experiment was performed. The data package will be used only by the USNRC and its contractors to support the evaluation of submitted assessment studies and shall not be distributed by the USNRC or its contractors to third parties. Proprietary, confidential or privileged information included in the package should be clearly identified as such.

5.5.1 Code Inout Model An input model listing should be provided in both hardcopy and on data tape.

Reference should be made to facility information required to perform the calculations.

Section 5.5.4 presents guidelines for the facility description document.

5.5.2 Calculated Data A digital magnetic tape of all calculated data should be included. The tape must be in either EBCDIC or ASCII codes in order to allow the tape to be processed.

Information adequate for naming the data channels and their units of calibration (pressure, temperature etc.) must be either on the data tape or must be provided with the tape. Table 6 lists minimum requirements for tape description.

It should be noted that formatting routines to process data tapes are expensive to develop. Thus, each participant should standardize their tape format to be consistent within each tape (i.e. data vs. code) and between subsequent tapes.

1 l

TABLE 6.

MINIMUM REQUIREMENTS FOR TAPE DESCRIPTION i

I.

Machine 1..

Name or type of computer that generated the tape; 2.

Word size in bits; II. Tape Format I.

Number of tracks; 2.

Packing density; 3.

Record size; t

4.

Blocking factor; 5.

Description of tape code used (EBCDIC or ASCII).

Binary coded tapes are not acceptable; 6.

Specify any record or block control words which are not part of the data. A word-by-word description of each record on the tape is vary helpful.

4 III. Data Format 1.

Description of logical or physical data arrangement on the tape, e.g., multiplexed, demultiplexed, etc.;

i 2.

Definition and location of timing information; l

3.

Outline any unique or special features.

3 IV. Other Scan sheets with measurement identification and engineering units.

i I

o 2

! h M-

)

} g.'

31

5.5.3 Experimental Data i

The experimental data package should contain all relevant experimental data and their associated uncertainties available for the specified test.

The data should be accompanied by a facility description diagram that clearly shows the location of each measurement device.

Each type of measurement should be discussed relative to the measurement process and data uncertainty. When data are derived from measured data (i.e. void fraction, mass flow, etc.) the equations used should be given along with the composite uncertainty of the derived parameter. Time-history data should be supplied on digital magnetic tape (see Table 6) as well as hardcopy.

A table of initi_a1 and boundary conditions should be supplied for the experiment along with a sequence of events which specifies event timings during the transients.

5.5.4 Facility or Plant Descriotion Document I

The facility or plant description should include information relative to sponsoring agencies and type of facility or plant. A general description of the components that make up the facility or plant should be provided.

Associated control systems should be briefly described.

Scaling information should be provided for experimental facilities.

All sketches, drawings, operational procedures, experiment conditions, setpoints, material specifications, geometric information and other information pertinent to the facility or plant description should be either included such that the input model could be reproduced or should be referenced.

If assessment studies are to be performed for a series of experiments in a facility or plant, a detailed description must be supplied only with the first study documentation. Thereafter, only modifications pertinent to subsequent experiments need be documented.

A system schematic drawing should be provided to clearly show how the various components form the overall system. The facility or plant should be described component-by-component, providing all necessary information to convey the component's function and operation as well as its geometry (areas, volumes,etc.).

Piping that connects components must be addressed to the same extent as the components themselves.

For complex components, a tabulation of volume as a function of elevation should be included if available.

I Component operational data should include delay times, rates of change (valve movement), performance curves (pumps) and all other control and performance information necessary to perform a simulation of the experiment.

Control systems associated with a component or group of components should be described to the level of detail necessary to convey their function and operation.

Sufficient control system data should be included to allow' duplication of the modeled control systems. Trip points and setpoints should be clearly tabulated for control systems functions (ECCS actuation, scram,etc.).

32

Hydraulic and geometric information necessary to determine loss coefficients and heat transfer coefficients should be included in the data package and referenced.

Insulation of components and piping should be clearly identified and, where heaters are used to insulate a component (guard heaters), their control procedure for the experiment should be' provided.

If available, regionally quantified heat loss information should be provided.

Insulation material properties and dimensions must be specified. Heat loss due to instrument cooling or uninsulated regions should be identified and quantified if possible.

System coolant leakage estimates should be evaluated and included in the facility description package.

?

33 N

4 6.

QUANTIFICATION OF CODE ACCURACY 6.1 Overview of Code Accuracy Ouantification This section is intended to provide a general overview of quantitative code assessment and its utilizatic, with details of the methodology to be presented in'other documentation.

The ICAP has the charter to provide support to the effort to quantify code uncertainty. The primary support effort entails the compilation of code assessment data suitable for code' uncertainty quantification.

The code must be sufficiently accurate for its intended use for LWR safety related studies. ~ This requires that the code be able to predict relevant phenomena occurring for postulated transients and breaks. The dominant phenomena will vary depending on the event, however, the code 1

should posses the flexibility to be used with confidence over its intended range of application.

Code assessment is performed to obtain a considered view of the accuracy and validity of the code over its range of applicability. A sound understanding is required of the code's ability to physically represent the phenomena which may be expected to occur durir.g transients and breaks. To-achieve this, the code must be exercised against a matrix of experiments.

1 The following considerations must be applied in formulating such a matrix.

1 i

o The code should be exercised in its ability to model all relevant j,

phenomena; this leads to a phenomenologically based matrix; 3

o The code should be exercised for different plant configurations of concern including, for example, cold leg injection, combined injection, once-through steam generators,'etc; i

Experiments selected for assessment should cover a range of scales i

o as a test of the ability of the code to correctly model full scale; and Experiments other than those used in the code development process o

i should generally be chosen for subsequent assessment studies.

The product of application of the code to experiments is a body of-information containing comparisons between code predictions and test data.

Thus far, conclusions on code accuracy based on assessment studies.have been

.i qualitative (e.g., the code predicted break flow reasonably well) and have generally been ambiguous and difficult to utilize by those engaged in plant safety related studies.

A goal of the present assessment effort is for the USNRC, together with the Program Group, to support formulation of more coherent, quantitative conclusions on the capability 'of the code by evaluating the accuracy of the code with respect to phenomena. Quantitative conclusions can be constructed only upon the basis of. a thorough, comprehensive physical understanding of the code's ability to represent relevant phenomena. Table 5 presents a list of key parameters. The safety barrier concept for fission product release 1

l 34

5 was considered in deriving this list, with the first barrier being the fuel cladding and the second barrier the reactor coolant system pressure i

boundary. The final barrier is the containment. The ICAP program is focused of the integrity of fuel elements and the reactor coolant system pressure boundary, hence, their condition influenced the choice of key parameters.

As an example, during a LBLOCA, the reactor coolant system pressure i

boundary does not perform its intended function.

In events involving core uncovery, the principal concern is clad temperature.

If the core remains 1

l covered as may occur in a small break LOCA, however, the clad temperature i

will follow the saturation temperature. -In this case, such concerns as coolant inventory and distribution and steam generator heat transfer influence the choice of key parameters. Similarly, key parameters can be identified for transients.

i 6.2 Anolication of Quantitative Assessment Results From an applications standpoint, best-estimate thermal-hydraulic codes i

are used for safety related studies involving the response of power plants to transients and breaks. The codes may also be used when planning experiments in scaled facilities.

Code assessment is performed to:

(a) provide quantitative information on the code accuracy for applications.

to power plant studies; and (b) provide quantitative information on the code accuracy in order to know what are the code development needs.

In each case, it is necessary to quantify the code accuracy.

Along with determining the code accuracy, acceptance criteria must be defined to resolve code improvement priorities.

If the code meets the l

acceptance criteria, then code development can be considered as being l

completed and further experimental programs are unnecessary.

If the code does not meet the acceptance criteria, then one or more models in the code I

must be improved, within the constraints of available resources.

This also implies that new experimental data may be needed.

It is generally believed that significant progress has been made through past code development and the code has attained a measure of reliability.

It is probable, however, that the assessment.and applications process will reveal areas where the code does ~not meet the acceptance criteria. This being so, it will be necessary to prioritize possible areas for improvement within the constraints of available resources.

This should be approached by addressing the following two questions for each deficiency l

identified:

1.

How important is the deficiency with respect to the understanding of plant behavior?, and 2.

How many resources are estimated to be required to reduce the code uncertainty to meet the acceptance criteria?

6.3 Accentance Criteria for the Code Simpleacceptancecriteria,basedonafewkeyparametersfoheach class of plant and transient, should be chosen to avoid the exceedingly 35

4 complex situation of establishing a unique criterion for each of many possible parameters. The proposed code acceptance criteria should include:

o Correlations and models used in the code should not be in conflict with any statements or conclusions contained in documentation used to support the model acceptability.

If any conflicts exist, they must be reviewed and deemed acceptable.

o Correlations and models used in the code should not conflict with other applicable data, correlations or models.

If any conflicts l

exist, they must be reviewed and deemed acceptable. -

The USNRC intends to use the results of the ICAP program to' support the effort to quantify uncertainty, and support further definition of the l

acceptance criteria.

In determining whether the code meets the acceptance criteria for the selected key parameters, care must be taken to understand the phenomena studied in the experiment and the code calculation.

For example, the code may incorrectly predict the minimum core inventory during a small break LOCA. This may be the result of incorrect break flow, incorrect ECC flow, incorrect steam generator heat transfer or incorrect mass distribution in the reactor coolant system. Thus the evaluation of the code should indicate which of the models in the code were responsible for the behavior observed.

i i

i i

i 1

l 36

APPENDIX l

l 37

%u g4,-

444_4

.. i....

i.g.

--gg3 m

m g _g%

+

b

-6 1

h o

f l

l I

Ir f

f I

b w.

i APPENDIX TEST MATRICES FOR THE ICAP This appendix contains tables that summarize two matrices that are integral to the ICAP. Table A-1 presents a phenomenologically based matrix for pressurized water reactor and boiling water reactor plant configurations and for large break loss-of-coolant accidents, small break loss-of-coolant accidents, and for operational transients.

This table presents key phenomena important to the calculation of system response during the respective scenerios.

Table A-2 presents the assessment plans that each of the ICAP participants have identified for fulfillment of their respective bilateral agreements.

The table contains the assessment plans relative to the RELAP5, TRAC-BWR and TRAC-PWR codes.

l l

l l

39

,eh-_A.I.*4m4 +M4 s ASS 4 4 eJa4 4h M-8 6L"b d 44 4-n84d'A"-b'4MWMM&"MM M8--M3'-*"""1*h AJWM*

SJ 2mWeC

-444 Aw(-h.&.4A.h J An. h A gul aia2M AA a pLMAa A $ d S _s.WA 4 d;, MJ

.h.24M3 Ag I

h-1 4

1

(

l I

4 f-1 i

t t

t 2

=

d i

b

- ii I

tl-a L

I i

+

4 1

i 4

4

}

J.

4 1-i e

't b

I k

l l

l 2

e 1

i I

(

4

+

t 4

I i

1 I

no

$YUE ggz o

i t

, gs o o ce s

x33x o o jn ts

$gz 4 o o i

e gyo o

d T

e s

3gw o o n

i t

w o

e b

ce z

m f

,z ga o o i

o

)

f s

c S

yE xM 5E ggm a

/

E k nn t

gm e

e L

aoo B

i.

l p e

i l st A ie

@ e1 e o T

/pc cS a

g~

,3m e e o e

- o o e e nme L

ouj F

g.~

,ggo e

e L

i pn A

t t/i s

.~

go af cf g O el T

~

wfmzm o e o

- o o o o o o T

ooe l

l s

t

{.~

_m a o o o o

- o

- o

- e S

s E

s k pd e

y.~

gm aml I

L euo T

5.~

g a. o e o o o o e o o o o o P

LPC P

m A

e 8.~

,ggm

(

s t

e s

3.~

ga o e o o e o o e e o o o c

y i

S k.~

,gv

- o o o o o o o o o o r

t

, ;=

o e e e e e o e o o o o o e e

e e a

t e

l m

s p

go gx e e e e o e e e e e e o e e e

e e

y t

T T

E 3o,m e o o o o o e o o o e

- e o

e e n

7 e

4f m

8o s

/

s 2t e

1 u

)

s b

n s

l o

a i,

i t4 t

e n8 a

d u/

m B

o 2

n r

N c

t d1 o

o R

an ye i

f

)

d ne t nl t

n e

E em i ni c

i c t s

G ms l at e

t u

a b

R e

os il n j

l e o A

p ne cpu n

o y

y L

y es a

i n

o

, r t

hs f rd o

p r d l

R dpay oe gi e

l O

t e

tt n

n t

, v a

i u

L o B r

F s

t seisdn c

e audl eea r b F

yN o

i X

t l soitml u

i n C r D i

g I

urcb rp d

r o C r

v o

n

)

a R

s me aso t

i

(

a o

T u

i vrt uf r n st c l o

P h

l A

s s

oisroe o

i a c c

i

)U e

g n

M r

yf ure s

i d

r i

d n t P

b n

em e d yt s e pd u t

t l

i i

a U i

o E

veli e v

e a w e u u g

e p l

n Cs tlll d ymd s o n a q r a

, r m a

NR aaaib eed re n l e r i

e p e o u c

e h

EW nli cat paot n e f p d l

f o r C p

s P

RP eut ati yefi o d y(

s r o (

i n d d

h n

pC e

c E

mmrfi mt rrm FN oia ui l ei t

o i n

g a

(

t s

i EI nSPtSLtAP1 a c o a m n r t n a r

R e

s s

r v

u i

t n t e h t

1 S

h eOeeoeeo w a d s n d o n m p

e SK P

T T

o p n e s e n t r e n E

m SA l

e a d a

l i

a f m i 2

L u

1 A

OE f

s i

p p b e

n a A

l RR g w y h

h i

r d Y

C o

e CB k

e n b

r m c a t n

S S

v a s i

e e a e n r n a F T

H S

I I

e a x r C p e r e t e

T F

T L

E B M lb r h i

o C p

t o u n e

- C O E K

P O E a

B P

M C E

U S

C QE D

1 C

LBPSLi T

gggJn.

,* e,3aN p-g,aN a:

I

Table A-1.2.

Phenomenologically based code assessment matrices.

Test Facility Test Type System Tests Separate effects Test G

6 A

CROSS REFERENCE MATRIX FOR SMALL ES E" E

.E AND INTEREDIATE LEAKS IN PWRs ****

%* %* *D E" x

- Phenomenon versus test type US UJ D 24 5

d m

o e Simulated U Ii U% uE m%

0 5

G E

o Partially simulated "o e %c 2E ExJ3

~

z t" *b EE %

8 8

i

- Test facility versus phenomena a

o e Suitable for code assessment Ud Ed IO RE ~u S E 2

M V

o e o ~

o o

o Limited suitability "E "E

% *8 3E 3

3 3 2 ". 0 Z %

$ f 4 4 7.

O o

o x Expected to be suitable DE DE %>%* S. % S % % % % J f

~ * *

  • ~

w

- Test type versus test facility E" E* 35 2o "3 I 5 3 O E $

t e already performed or planned unit 1 12/84 0D3D 5 h* 3 5

7 M S #

3 $

~t z

E E E k%

o Performed or planned until 12/84, but of %5 %5 %8 j% 3J E d C # 5 3 0 E #

ln h h

~

u a

m limited use ME ME MI oO fN A S f 3 0 E D S 3 M S 5 d f f d I E $ EU Natural circulation in 1-phase flow, primary side o

e e

o e e e e o

e e Natural circulation in 2-phase flow, primary side e

o e

e o

e o

e e Reflux condenser mode and CCFL e

e e

o o

o o e

Asymmetric ~ loop behavior e

e o e x

x x o o Leak flow e

e e

e e e

o e e e

o iD Phase separation without mixture level formation e

o e

e e o o

o e o o

Mixture level an.1 entrainment in vertic. comp. SG "'

e e

e e

e e o

o x

e e Mixture level and entrainment in the core e

e o

e o

o o o e

Stratification in horizontal pipes e

e e

e x

x o o o e

ECC-mixing and condensation o

e o

e e o

o o o 3

Loop seal clearance e

e o

e o

e e Pool information in UP/CCFL (UCSPj e

o e

e o

x o

o x

E Core wide void and flow distributi on e

o e

e o

x l Heat transfer in covered core a

e e

e e

e e o e e

e e

~

e Heat transfer in partially uncovered core e

o o

e o

o o e

o 2

Heat transfer SG primary side e

o o

e e

o o o

o e 0 x e e

Heat transfer in SG secondary side o

e e

a e

e e o

o e o x

e Pressurizer thermohydraulics o

o o

e e e o o o

e o Surgeline hydraulics o

o e

e o o

o o e

1-and 2-phase pump behavior o

e o o e e o

e e

o o o

o o o Structural heat and heat losses ***

e o

e o Noncondensible gas effects e

Phase separ. in T-junct. and effect on leakflow e

e o

o e

Upper head mixing o

e e e o

o o o o

e o w

PWR volumetric scaling OO LOFT e

o e

e secondary side

-g tgyg problem for scaled test facilities U"

ilETHSY

u. E pgt,g for intermediate leaks phenomena included in lar break reference g3 ms matrix may be a so important d!h LO8I-Il e

e e

e

's e e SEMISCALE o

o e

e e

e e

Tcblo A-1.3.

Phenomenolcgically based code ass 2ssment matricts.

Test Facility Test T y System Tests S

E E

CROSS REFEararE MRTRIE FOR TIUutSIENTS IN PIES E

E E 8

o. o

~

- Phenomena versus test type i E S S 2 O O Z 2 O f e Simulated

i. u u

o Partially simulated 5 % E

- Test facility versus phenomena I

3 A 3-3

=

O m

e Suitable for code assessment A 5 E

e o Limited suitability 0 I E E U;

en w

- Test type versus test facility 0 E I E

  1. S

~

+

+

c e Already performed or planned untti 12/84 3 5 O O Y 7 M T

~

o Performed or planned until 12/84, but

$ 0 0 % f I C $ # '. O E E $

o

. cr limited use G 3 3 5 5 I 3 rI $ f 3 $ $ E S 3 M E A

natural circulation in 1-phase flow e

e o e o e e o o e o o

e o Matural circulation in 2-phase flow e e e e o o o

o e e._

f. ore thermohydraulics e e e e o o o e o o e e e Thermohydraulics on primary side of SG e o o e o o e o e o o e o Therschydraulics on secondary side of SG e o e e e e e o e o o e o Pressurizer thermohydraulics**

e o e e o o o o e o o o o i

Surgeline hydraulics (CCFL, choking)**

e e o e o o o o o o o o o Walve leak flow ***

e e o e e o e e e o

o o o j

1-and 2-phase pump behavior o e e e o o o o o o o e e a.

Thermohydraulic-nuclear feedback e

e e e Structural heat and heat losses ****

o o o o o o o o o o

o o o Separator o

o o

Boron mixing, transport, and plateout o

PWR 3

o

    • 3 LOFT e e e o e o e LSTF BETHSY s.- g PKL-1

+* J SPES ES LGBI-Il o

SEMISCALE o o o o o o 0

Volumetric scaling For phenomena requiring separate effects test. e.g. pressurizer behavior, refer to small leak cross reference matrix Valve flow behavior will be strongly design-dependent, specific experimental data should be used if possible 1

        • Problem for scaled test facilities i

l

Table A-1.4.

Phenomenologically based code assessment matrices.

Test Facility Test System Separate Type Tests Effects Tests CROSS REFERENCE MATRIX FOR LARGE BREAKS IN Bedts

  • * * ~

e

- Test facility versus phenomena U

E O R 3

e Suitable for code assessment

% *i % % % %

o Limited suitability

.a

- Test type versus phenomena I

E E

e Phenomena occurs j g

{

g

[

o N/A g ; g y 4 g

w I

j

- Test type versus facility g ;

g g g j g g g g g 3

e o Facility applies e g g g g g

g g g g g g g g y o

=

o Facility does not apply a

Neutronics e o o e

Metal / water reaction Interfacial shear e e e e e e e e

o e Interfacial heat transfer e o e e o e e e o o e Baron mixing and transport BOP and control systems o o o e

Post CHF heat transfer e e e e o e e e o e

Fast numerics e e o e e

o e e

e tevel tracking e o e e o e e

o e

Jet pump ECC injection e o e o e

e e e

jContainment e e e e o

e Core spray e o e e e

e o

e Break flow e e e e o e e o Separator o o o e o

o Reflood heat transfer o o o e e

e o o e e Recirculation pump behavior e e o o o

o o g

TLTA e e e e Power plants

-f FIST e o e e gJC TBL e e e

  • E.S ROSA III e o e e FIX II e o e e SSTF o o e e l

Tabl2 A-1.5.

Phenomenologically based code assessment matrices.

Test Facilities Test System Separate Type Tests Effects Tests CROSS REFERENCE MATRIX FOR SMALL BREAKS IN BIRs o

- Test type versus phenomena g

m o Phenomena applies I

o N/A g

- Test type versus Facilities

j g

e Facility applies E

,a a

a o Facility does not apply g

y n

a

- Test facility versus phenomena 5 g

[ g g <r g 5-

=

m e Sultable for code assessment g g 3 !=r 3

= g 3 g g

I o Limited suitability

= m - r a w = w a a = x w e z Neutronics e e o

Interfacial shear e e e o e e o e o,

Fast numerics e e e e e

,c Level tracking e e e e e e

l Jet pump ECC injection o e o

e o e e

Containment e e o e e

[

Core spray e e o

o Break flow e e o e e o

Separator o e o e o e e

Recirculation pump behavior e o TLTA e e Power plants o o

+>

FIST

  • e j 3 TBL e

g g

ROSA III e

a w

FIX II e

SSTF 0 0

Table A-1.6.

Phenomenologically based code assessment matrices.

System Facilities System Separate Tests Effects Tests CROSS REFERENCE MATRIX FOR NON-8REAK TRANSIENTS IN SMRs t t g

- Test type versus phenomena b

2R ;

e Phenomena applies E ; 5 o N/A 4

2 3 g

- Test type versus facilities g

>. I y

e Facility applies 2 : :' S

,a

+'

o Facility does not apply t

i 2 3 3 g i

a

~

=

1 o

- Test faci 11ty versus phenomena 0

t J

2,

, m,

a r

e Suitable for code assessment R S g g g h C g n g g m

" < I 8 * ' * * ' ' w m H o Limited suitability kutronics e o e e e e o

tetal/ water reaction e e e l

Interfacial shear e e e e e

o e o g

Interfacial heat transfer e

a e e

e o o o I

bron mixing and transport e

BOP and control systems e e e e o

o

,j Fast numerics e o e o n-Level tracking e e e e e e

o e o e o Containment e a e e

o l

Recirculation pump behavior e

e e o

o g

TLTA e e Power plants e o e e e FIST e e e g

g FIX II o

,yd ROSA III e o TBL o o

l 2

w es g

h a

s m 's s

E 5

I 3

zigg 5

5 s

v w

m a

=

[

==

=

=

=

=

=

=

=

g g-E-E E E g_

E 5

51*Ig E 8

.s

=

5 ! E a=

=

m E

m-

==

c.

n a

.- s - -

g E-8 =

ws wI

=.E

=

a w

- -. x s3m.5 n g E

Es a-g w a s Is. I-I g a

=g A

w w w

.= w sti.

E.8 z

s w=

E-=a e

.c

=

n g

=E E!

E5 a

m" h

f E

s a

m 8

=l 5 m a

m x

1 a

1 Ig e e s-E E =

E E E E E E E

E E E E E E E

E E

E E i

9 N

tl U

w

=

b M

2 g

i s

3 3 y

3 s

v I s

-e

< =

w r e

e e

e e v

=.

=

e e

e e 3 5 5 m

.. 3 e

a N

M (4

M M

w 80 m.

i V

e E

5 5

5 5

5 a

ee EE a

a a

ai !

e a

a E

aE m<

i U

pe a

N e4 0

".c w

,2 8

1 se 45

=

s s s s s s s a

s a

s a s a a a

g a

a 3

e

= e e = = = = a

=

a a s a a a m

s s

E I I E3I N I E E

E E E E E E E

E E

E iii r

47 l

a

-n

-l s

e m

5 E

E a

i M

E-a E

8 u

s a

a m

I E! G G G E

G E 3

g i

G E E

a a

  • I 3! E! EE E E E Ig 9 5E

!~

EAE E

s IE a

E E se yE E "E

E in is

~

- sE g 35 s; E gi g I gw

-r

~~

a a a g E, I=m z

- a g

, i HE EE Em E EB IE EE RE e e e u m

= E i 25 m z

E E

E E

g G G E

EE a

s e

=

ma m

E!

IE E

E E I E

55 E

E E E

E E

E E E E E E E E E E E E E E E

E ni G

E E

E E G G G W G E W G E W W E E

E E E

~

E E a s a a a a u a

a

=

e

= e = =

= gg g

g g

g ggge II E E l =l EI Ea==

a

- g3 IE a

a

=

= a e a

=

=

=

=

=

=

3! E 9 9 a a

s si s

s s

eeaaa ainiIE s

s s

a s

nasas aaaaae

a

-5 mE s a v E

,5 eea ea.

E M

~. * ~ " ~

a a a a a a a

~

~

" " ~

E n

n n

nannt tnniii i ei i

1 I

i i 1111 i II d?

g 3

m a

a a

a a a a a a ea 3 3,

3 3 3 I I

a ts I

E W 4

4 4

4 4 4 a 4 4 4 4 g g

g g g g

48

l i

a g

e gg a=

I ". I il E

g= E ug u-3 m

a l El E E E E E E E E E E E E E E E 8

E EE 1

lEE E

'I i

EI E. EE [ I i i i E i E E i lE i E j mE "E

gg d =.. c

.a d- * * * * * * * * * * * * * * =

I*

mm E gw R -5== =========== = = = = = = = = mg If If In g

En R* Es s

-r

-e s

A:

=

= = = = = =

=

s i

s a

I E

E E

E a

a 5

_a En s

6 e

i i s

a 2

E E

E E E E E E EE E E E E E E E E E E E

E E

W W

W W W W W W W W W W W W W W W W W W E

W I

e = =

8 M M M M M E e E = m 2 E I

I I IIIIIIIIIIllg g Ieg i

g

  • II I

I

Ig g

n e

i = = s=====g-a-

m a a m i e 5 5, 5 5

,e

.....,.,...,.aE E E E E,,

4 - 4 4 i

l I i iiiiiIIIiiiIIIiii I

i

_=

i I

i dl s

s In

.e I

s s

s s s _s _s s a_ s_ _s s s s s a_ _s a_ a s

_s 49

L N S

L M

E O O

KI l

R R

R L

V

. l T

l i

E E

u e

W F

F S. i M

p n

K O

S S

C RC II o p

u C

i F

L M

ua

,A E

e I

l A

e

,C KI KY M

C A

A T

T B

S L

S R

I T

E C E M E

E i

A A

8 f

f B

B I

8 B

S I

I l

S K

8 U A

I i

s K K K f

f E

E E

SK S u I

K I

K l

M I

K l

P L

8 B B B u K

K I

K I

K I

e 8

I N

u 9

E M

u t

I m

Mi q

e M M l

u e

I K M t

E E

E M M M M M M u

E E s t

t s

E u

L,

L t E

E E

E E

E E

E i

E r

E H

R K

l t

f T

T i O I

E I

T T

T I

T I

T l

i A

a nl tC 3 G T

l r

p F

F i

K K K lluPI CM C$l K K K K K K K K K M M l

F F

EI t E L u S

8 M

N u

S S

0 u 3

I M

5E

$f ll E

f R

R K K K S

S K K K K K K K K K S

S R

u t

e E C 1C 1 E F S 0 S 0 C E

5 W 5 u e

u m

I 0 I 0 I O

0 O

8 0

0 0

O O

K E T

9O 8 D i

O e

S O

e EK 2I 2 L I

1 T

1 1

1 1

T T

P P

E

( P 1 P S

C C

T T

f i

u IK A

R K

MM K

I T EI tK 8

6 TS u E u 8

i I u 1

L 3

5 3

S 5

5 5

5 5

S 5

5 5

S 5

5 5

5 5

5 S

S W

P P

P P

P P

P P

P W

E P

P P

P P

A A

W P

W A

A A

A A

A A

A A

A A

A K

A L

l L

L L

t L

L L

L L

t L

L L

L L

L l

L L

L K

K K K K K K K K K K K K K K K

K K K K K K a

C es 3

S e

1 I

n C

C e

E E

F F

T T

f i

T i

F F

M M u

M M

M E

E I

A i

I n

L L

L L

L L

L L

F E

E A

A P

P P

P P

P I

T A

A R

e A

SI G

R R

R t

e t

M R

i u

E A

eM K

u f

K f

t E

u u

F P

T T

4 t V N

u 0

e S

e e

9 E

F I I I

I P

P P

P P

7 S

n i

E g

T M

e E

s T

e V

S n

l u

T E

e l

n i

i T

i M

M M M

M M t

L K

F F

u C

8 O

F L

L P

P P

P P

P N

I E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

B G

O 0

0 G

S S

0 O

s L

L L

L L

L L

L L

L L

M A

M A

R e

A M

M A

R s

N n

R s

M N

n M

s n

u M

u I

e I

e I

I e

M G

e A

A u

u u

m 0

e g

u n

m m

e g

I e

o 9

9 O

o 9

e 9

O c

O s

I O

M M u

N N

M n

4 P

P P

P P

P P

P r

N u

N W

P A

A A

A A

4 A

A a

AS S

S S

S S

S S

S S

E S

S S

s S

G E

S S

S u

u u

N M

T u

u A

A A

A A

M M u

M a

A A

C A

E E

E L

E S

6 S

6 E

S S

S S

S S

5 S

S S

S S

TM t.

C l

M M M M M M M M M t

R R

M M M

M M M M

8 0

u u

D 3

3 9

4 1

s8 i

u4 t

G i

f T

T t

f T

T T

T T

T A

4 A

E A

A 4

A n

4 A

E E E E K E E

E E

E E

E E

K E

E K

e5 M

4 R

t A

L l

B e

R E

A R

R A

a2 O

1 i

1 i

T i

T I

T 1

T O

a O

D G

O s

O 5

g1 A

6 O

P8 C

1 l

1 l

I l

I I

I l

I E

r B

K E

F E

F 6

E E

uO n

1 1

q

l C IM31M D 01 Z O d1 CC1]

Clev3D 3 Set'O alta l

SDIM31M M 01 1-05-J1 Calm Selst3M 350t *ue ultJS eDiuMM M el Z-d w i sm1M Soluv3M iSet u utidS GDin3130 M 01 CdV1M SeluO M 350t *st ul1Ji r

831558333 83At1M

'Im tu ulla M3 0 lluuS t-d$

CNIM MUS31st IMI S015t3M 350t ~48 utid5 GDIM11M M 01 Calm MW133d5 *f '80

$4HluDID SDluu11M M 01 Calm usu133d5 "r *3m SOWisDID GBlW31M M 01 EdW1M usu133d5 *t *ta SW1EMIM GDlus31M M 01 Calm WN133JS *t *N SIM1gMD GDlW31M M 01 Edvim usu133d5 *r *H SemluMD GDlW11M M 01 SalM Wuu133dS *t *N SmtluMD SDlW11M M 91 SalM usu133d5 *r *st Stuv1gMD IDin31M M 01 SalM usu13345 *r *ut seulIMD GBlW11M 30 81 Calm usu131d5 *t *st SIW1uMD -nn SDIMMM M 01 Calm usu133d5 *t *M SmtluMIM i

8DlW31M 3181 SalM usu133d5 *f *W SeeluMID Edin 31M M El Em135 usu133d5 *t *st ScutleMD GBlW31M 30 01 SalM WW13345 *t *st SentitMD utifulO013 indivu talM

!Wid 3DBd 3135u00 usu133d5 *r *W SturluDID lu11Sunt Sul100M3ONu Calm IW1d EDSd 313550E Mu133d5 *t *M StelluDAD t

GDlW31M M Of talM 331 NGOu Suv5 *M VNO3 EDlWHM 30 01 Calm 331 NOIN SMS *M 93u03 I

I EDIN 31M M 01 talM 3ji aggu guys n gygg SDIM31M M B1 Cal]U 331 gogn Surs m g3gj NOlldlu]SM 3d11 830Mu 3411 luDlu1J13 IdBII3dt) 1531 3001 lu))Sunt Attil3vj 1Mjuc3 Aging) eesse I I E t v u 15 31 essee at/Slf20 1

  • eu a6ed

! III 8

=

!5Ii!

I sse a ai i

E s:

a a

e : saaarra rrraaraen

= =a

Eg-laaaaaa

= s

_a aeaaaaae E gg

=

=

E E E E E E g=a*

  • g :s :s is E E E E EE E

_ Er at gg g

-w a w w w =

a w * * * *

  • s

==

= a e e e

s s.- E ut us e E== = = = =

i 55

_l i

n =

6 e

E E ssssssssssss s

sgsssssss I

s a s s s s s s s s-s s e a

s=sssssss E

E E ssss sa esss

= = g g g.g g

1iiI

  • ===
=

- se Ii===e

=

==

m a a = a a

a a a a e=

.= _

m i

5 E E = = =

m a a a a

i i E E E n e

! E as i

i II III I

III i i !!8E!gggg((

[

[gg s s a a a s a n==sss

=x

= x = E w w w w

5w w w w w w E

d d d d J d 8

eiiieeiieiiie i

iieieeiei 1

t xaar

  • g=gggssg i s

=

= =ss

l p=s g

=ssssse=N N N

  • N N

N

=

=

I N a a a a a a a a a m a a a m

52 l

l

=

  • !I I

E E-a s

e

.a E.w Em I

a e

=

e

= w Q w y w a w w w w w w w w w w I

I e-s E 5 "

a -

E E I w

E E E E E E E

=8 e = w

  • E

-W

?

  • I. 5E

= E *

= = = = =

E

=,.

.G_.

.Eg E

w w = w = w m

-_ w w I

_ _e

w

w s

w w w

g eg w w w E!I a Ee

- w w w w w w w

_g

- a w Bw e e e EE Em E! e e E B

= = e = e e E

m E

EE g

M I

?

?

?

? ? ?

en a

=

=

= = c g

E E E E E

E E E E $E E E E E E E E E E E E E E

W 5 E E W

E E E W = W W W W W W E E 5 E 5 E W

=

e e_

E E E i E i E E E E E E i E I E E

-g E

E E

e e e e e e e e e e e e e e e g g 3 =yE E

E E

EEEEEEEEEEEEEEE,,E E

W

.! =

2 a

B B

B E E B B B E E E E I E E E E

...............g g

= w w a w

e E E E E E E E E E E E 35 E E E w w w w w

w

.... m a w w w w w

w s a s a a s y a a s s :s y a a e e E

d d J d J

d U U d U k U C N b U d nE E b E E E

N N N N N

$ N N N E I I I $ $ $ 5 N I $ I I

~

I I I I I

I g=

w w

=

=

B 5 5

-a E

I E E I E E I E I E E I E I I

.h.

E a a

-E E

E 2

_a

_a a a a

_2

_a a_ a s

_a a

_a

_x s E a

a m

53

L t

5 3 mE w =

m a m m:

5 5 g

g-E E 3 3 m

E E m a a a a

E ll i

s5slssss s

I s

sa se i

5 E E E

E g g g g M M = M m m a m "5

W W W W W W W w k

kk$

E m

a a a m M

ese E

E i e

? I I_

_ =

E E

E M

E E w E E B a E I E E E I E E me se se ese em 2 % $ d 3 3 2 $

E E E I EE E E E B

i d d i siai l

15 I

aaaaaaaa 54

m 8

s

=

m

=

w W

3 I

a s w

- m a

=

s u

3 =

= w w

)E I........m

!E a

5 "a

s w w I w E E E E E E E E s

a ga a a a 3 s a a a a a a

! s g-E"

=

w x

[

s u _g

= u s.

m 3

W w w w w w w w w w w w w gr g gw 1 l,w og o

a a w w w w w w w w w w w 3 g3 g

=w w E = c5 En

=g gp g - -

= e e e e = = = = = = = w a a

=

EE E

_w El I I I I I I

I I I I s_

aaa=s s

sasssssssassa=saE kkkk$

$kkkkkkkkkkk$$kkk a a a

,a

,a a

,a

-e e e e e

.s a w 8

5 EIEEI E

E 5 5 5 5

.5 =

=

8 aaa a

n n

EEEE i

B B B e e B

e a w w w w a s a s s

a

= e g g g g g g g g = ==

d d d a d d

a M M M M M M M M M M b h b b

= = = = = = = naa

a a a a a a

a n

a a a a a a a a a a a e e e e a

Qtttt t

t i eieieieieieiie i lili j

j

,u s,a,, W,a a,s a w,

4 E

w w w w w w

w 8 W W W W 4 W W W W W

-}.5 a d a J d d

a = = = = = = = = = = = =

e e e e e e

a w a a a a a a a a a a a E E E E 55

~

k 1

I I

s*

w g.-

E I s

5 s

a s

s E

a ! I E =

4 E

a g g

=

-2 g

u s a s

a

. = s w a

I g s-ggI

, u

-g n

a,,I_m,,

E e

=g a

g=a 1

a-

, l 2.

n

=

IE I

  • ag

=

a= I E E

E.

sw gm a m

=

.a

!tu a

I O

-1 ei=

i a

w

=

=

s

=

i 1

l 3 2 E E

S S S S S E 3 3 E.

u a

e e

4 4

8 1

I e

s g

uuu v

vvv yuyvyy I.

M M

5 5 } g 1

III I

I, I, I,. l. l. l= E ff

=

EEs a = a a

a a =

m = = E EE

=

=

=

=

e.

M tee i

f g

w

= t 8

.=.

4

- -$1 1

h G U G E

E D

=

=

=

4

.e eso one

.e se me 3 $ 2 2

d n n 2 d n

.e i^

U t t t i

2 2 E E E E E E E 6

a a e a

a a e a a a s a u 1

4 i

ce i

a2

=

E

$ h$

$ h h $ $ h 56 t

i l

=

=

s a

e e

e a

=

m e

e a

=

=

g g

i a

g g

g E

s a

a a

a a

a a

I II EE I! l! lE E l-lw ls gg I! E E8 E8 8 8 E

_s a

e

.o s.

5 e5

=5

=

5 =

=g 5

=5

=e ge I.

=5 25 c

=

=

=

=

.a

=_5 s

s_

25 5 NG EE_ "aE

  • E E-E =-

G d=-

s

~- MG ME wr 8

8 E.

E.

=

as

=

=

-! E! EE EE EE E! E E RI E! EE NI EE si et EE EE E,

E m

E_

Er

=I s

a

=

=

=

=

=

=

=

E v

a v

v v

v v

i u

a v

v v_

_v v

v O

O C

G G

G Q

Q Q

Q O

O

=

u e

e e

g

=

e e

=

=

b b

e w

a b

b b

b 2

b s

a b

=

_a w

w e

w

=

w e

=

w w

e

=

w i

.a

.a a.

a a

a i

i I

I e

O M

W W

M W

W W

W W

W m

a E

5

_i =

=

=

s a

g a

e m

e a

e n

=

=

=

=

m a

a a

a a

a a

a a

a e

a 5

g E

g s

s a

s s

s a

a s

I s

s s

a a

a s

a s

a a

a a

a a

a s

a s

a a

s a

d a

d a

a J

J J

J J

J J

a J

m J

J J

J J

J J

J J

J J

J J

J J

J

-W h

h h

B h

h a

g E

E I

E E

E g

a 8

e e

e e

e e

=

e i

I 1

5 1

1

.I

.i

.I i

i 1

i e_

=

=

=

a E

l 4

d 4

4 4

4 4

4 4

4 4

4 4

4 s

a a

~.

57 w

5 E

1 a

s E

E E

I E

I 4

3 a

~

8 E

E s

=s es er

=5

=s 5

  • E cE cl cl il g gg l

= di di dj eg el EE iY E E

l E

i E

i i

E a

=

e m

a r

-8 da g g

g g

== =, =, =, =,

=g g g; ge =i =se

$=

d

_w

_s su g a =:

{

=a

=a G G E gs E E Ed Ej E E

Es EE EH EE ga gg gs 5

a 3 s! r= =s =s== su su un r! ra e' I g

~

=

=

_a w

a-m-

m-m-

m-m-

a.

m-at g=

g g

.==EIEII!m!mI$IIIs'$_isisilmla$2 EI E

$a =r =r _a ms I

==a

==

m =

m.

a==

=e n

nw=

\\

ar

_i aaI i ais s

e e

s s

= 5 5 5 *

=

5 8

guvvv v v M v_

v v_

v g

u u_

y v

v v

e e

e

=

=

=

=

=

=

=

=

e e

e e

e e

=

=

=

sss ss a

s a

s E

s a

s s

s s

_e e e e e c =

w w

w

=

=

=

w w

w I!e a

a.

y a.

.a a

r

=

=

m m

w a

w w

a a

a m

e e

e a

e m

4

+

+

+

=

+

i.

e n

a_

=

=

n i

i i

i i

I E

g g I EE E E E I I

I I

I l

5 l

5 E

l e = = = e g

- -EEs 9 eQ N D w

a s

u a

a u

u a

==

=

I w

w g

y 5

5 5

5 e e e e e e e e w

w w

w w

a a

w w

w a

u 8

r! tnt ttta e

e i

i e

e e

i e

e

1. 1. 1 1. 1 1 1. 1

=

~

.5 a

}a d a d d a a a a a e e e e e e e =

58

l E.

E.

E E

e e

E-1

=

g g

g E

E E.

=

=

a

=

l a

a_

a_

a

====== a 2

U U

S d

I en el el" E Kl E 5l, es es eln Ki si f KA K"

K

=

e_

=.r r

a r

a d * **

gm 5"

    • 83 5-5-d-5 di n*.Ei Ed EJ EEEEEEEsE 5 5 a 5.

M d

d.

M EJ a

eg e5 es e3 mE mE mg e-g s s g3 Eg ga sg Es

=E w

zg wg wg w_

=E ee e E

e n-e l_ e E u-l_ e 1 s5

=I =!m.

=

z!

=! el e

v.

v.v.. v5 m-a-

a-e s

=

s.

u-m-

u_

ve u

==

v v-e-

EE E-53 53 Ee EM EM EM E-Et j j j lM lN- [X lX =V -

.=a.=- __

_M

_E M

= _N

=== w w-xx ex es

=

_.- = = = =

=~ =~

=

E

=

Er E

..=

=

=

=

c

= =.

~

v v

v v

v v

v v

v vvvv v

v v

v 5

g u

_v

_v g

u_

g u

v M v v_ v g

u_

u_

v

=

=

=

=

s e

e e

e

==

=

=

=

=

=

e

=

e e

e

=

e

==

=

=

=

=

s a

s s

5 e

s E

e asas s

s s

s w

w w

w w

w w

w w

w - - w w

w w

w e

a I

a E

E E

a E

E E =2 a

E a

a a

g m

m a

G w

w a

w w

m a m a

a m

a w

e e

e e

e e

e e

m

!I i

i i

i i

i i

i i

= g i

=

m E

E E

E E

E E

E E

i i_ m e

a i I i

E E

=

=

=

=

=

a=55 i

=

~

c 5

5 5 55 l

5 n

i

=

=5 5

=

=

=

=

=

=

=

=

=

=

=

=

.. =

=

=

=

=

_g d

a d

a d

d d

d a

a a d d d

a d

d E

E E

E E

E E

E E

E E E E E E

E E

E m

gh W

W W

W w

_k

=

e

=

.5 59

E i

\\

Ea 1

e W

9 i

e 35 sl =

=

m u

I

_ g g,

g g

g g

W.

W.

W W

W W

s a a a e

e - e a

a

=

=

=

=

=

W==

g g W g Im E Em Em Em Is Eg s

s g

g g

g Ws

_a _ e _ eE e

e-e=

em e-

=

=

=

=a

= = = W W WW W W

W W_

s-m-

a s

m-m-

i g !!! Y Y a!! Ya Ya g-ga YaI gi $a-g _. g5 gl I

-s 8

5 5 8 g=

-l

-a

-a a sa

-a

-a

_a Il-l]III-

-l e Ej W W is W

W W

WI W WI.] WW ml-a =

l in zi W

W W

=

a-a m-s-

a=

a-m-

s-m-

a-a=

m-E E

-EE e

E!

5 5

E E

=

a

. n =

?

5 4 4_

4 4 4 4

5 5

4 4

4 5

e 4

E M

M MM M M M M

M M

M M

M M

N M

M M

=

n

= = = c

= c c

g

=

=

=

=

c c

g c

=

e = = =

= e

=

g g

e e

e e

=

E

= =

= m

=

m a

W m

E

=

=

=

=

=

_=

=

= = w w w w w

w w

w

=

w w

w w

w e

E E I E E E I

E E

.E E

E E

g m

a a a a m W w

w a

a a

a a

m W

w a

=

I I

~

s!I i

I v

v v

i a

y a

a g

M v

v v

v v

=

v

===E E E E

W E

E a

a a

a a

s a

m

=

M E

E E E I I I I

I I

I E

I E

E I

E E

z u a a n

= m

=

n u

z n

a m

z a

n W

W W W W W X X

W W

W W

W W

e W

W W

W W W W W W as W

W W

W B

W W

W W

W W W X X X W X

W W

W W

W W

W W

W X

Y d

i i d d i a a

a a

el i

a a

i i

a a

g E.

E E E E E E

E E

E E

E.

E E.

E E

E E

w W

W W

W W

W W

W W

j h

M I N

$ h-I l

I I

S

~

=-

=

= =

=

=

=

e

=

=

=

=

60 l

a-Y 3

2 2

3 3

2 2

2 3

3 3

3 3.

!==== _==

W "i "i "E _s _s _

"s== !s =

lllI,lI,*=ilI,l".E$,E$,,E!,E!E!g=Es, Ig g,

ga ga 55

  • E
  • E I WI
  • W En In Im !=

=

m Ej E! E!.

E s,=,

==

g=

=e. We W w-m

  • =. *=

d=

  • = *=

W

-

-

W e

~hh h._,_,h h

,,k I$ Ih h

=_h =_==I,h h h

h m_

=,

=W

=_ =_

m_

m_

m_

E EI M

$I g

a a

a s

i

=

=

=

=

a a

n n

s_

s W

s s

s s

s l

_M w

M M

M M

w e

=

=

=

=

=

=

=

3 5

2 5

2 2

2 3

2 2

2 2

=

2 C

E M

M M

M M

M M

y M

M M

M M

M M

M E

E E

E E

E E

b E

E

,=

w

=

=

=

w w

w w

w w

w w

w

=

=

w I

]

E E

{

E g

I E

E E

E E

E E

E

_IE E

w E

E W

9 W

E E

E E

E E

E E

W W

W W

w y

y i

i I

I lW I

I I

I i E E

5 5

5 5

5 5

5 5

W E

g g

4 4

4 4

4 4

4

=

3 3

3 3

3 3

u 4

u E

I I

E E

E E

E E

E I

E

_E E

E

~

m D

D D

D D

D D

3 W

W W

W W

W W

5 W

W W

W W

W W

W 8

8 W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

d i

a a

i a

d i

e d

i d

d a

a d

b N

N N

N I

I N

N I

N N

N N

N t

i eri e

>e I

I I

I i

i I

y E

v g

y i

E E

w w

w w

w t=

8

=

=

=

=

=

=

=

=

=

=

=

=

=

=

61 2

W1 a

w e

=

3 a a a E I

E E

g

.=

ms m

2g g g g e m.

r._

e-r-

w-w s

s8 n a s8,

sw E-E E g*5

.I w w w w w w w w w w w s

25 35 2R = g g g a g a g s_ g ag

.s-e, =-

w_

w _-

e

=

e.

e e

~

,= g g g w_

w W*

W*

W*

Eg El W*

. m W W W X * * * * *

  • w w

w w

w w

==

==== a5 a s, sa m, sa, !w e s s

u u

w = w w w w w = = =

eg e -

u a

a

= = ====== =

Ea UE

=_

T ? ?

N = =

= 3 3

_g g

Sm A

N 5 $ $

n n

M.

...T T

% T b.

M X_====_==

=

=

=

=

3

=

=

= =

=

=

M M

M M M M M

M M

2 2

2 2 & &

2 W

"b w

w w

w w

w w

5-W W

W W W W W

W W

W W

g g

g g

g Ig g

E g g E E e

  • W W W

=-

m a

a a a w a

m a

= =

W W

[

]

a 9

a a

g 5

4 4

4

=

= = = s a

e a

=

g "E

- A a E E

E E

W W W W 4

W c = s a

a.

2 m a w w m

E 5 E E E E B B E

E E E E E E

=

G" E E = E

$g g 5EEg g W

W W W W w a

w W W W w m

m 8

8 M M 8 M W

W W

W W W M W X * * * * *

  • W W W W W W

W W

W W W W E,

5, E,

5, 5,

5 g g

o, y

E.

=

E.

E.

E.

E E

E

.. E E.

E E 5 E E E E E

  • g E

E u

3 i

Eb h

h k

kkk

'k k

N k

kN5 5 5 5 5 5 5 5

=

=

===-

=

=

=

=_========m a

i l

s I

32' x

e

_=

=.I

=

=s w

e a

~s_

a 5

- 3 =.-

  • =

=

.= -

._ =

gz g-

=

z-m W

W W WD W W W W W W W W W W W W O W

M

=

=

=g a v gg gm a v ; != W E ss zaaarz

==

= = = =

E= E! E! En

_= = = =

w z E,

E=

a g a z E gg a m m g-a w z w a m

-E

g

= = = =

!E I== e=

t Es e = =

g ===

= -

la e = = =

e- = 5 CE 85 55 = =

e

=W

_=_r s

=g v

v v

--=

=

~

3 3

3 0 0 3 0

t = 2 vvvvvvv v

v v

vvv v

vvvv vvv

.M M M M

_M _M M

_M

_M M

M M

_M _M

_M M

_M M

_M M M M

=

=

s 5

i n

t 488 5

855 g=

5

=

=

=

=

=

=

_=

m

=

=

=

=

=

W i g 3

E a

a a

a = m a

a a _

w s

ua a a a a a a y g g 8g t8a i

m = * = * *

=

e e

e e e e

e e e -

e e e

=

=

e

=

=

==e E

=

g g g Eg Ia W

4 4

4 a a e a

4 4 4 4 4 4 4 a

a a a a a a-a a

a a

a a a a

a a-a-

a-a-

a a

~

l I

!II I

IIII III

=

=

=

=

=

= =

._ae

=

=_

=

5 E 5 E E 5 m

=

-a a

.b=

5 Eh $ k k & E

=

=

=

=

= =

e=

=

a a

a a s s a

a a a s a 63

s a

EE E

E aa g

g a

g.

m y

a g I is as E I EE E EE E 5 a

u l5 si a ii;i

~

E i j i i =

5 g a s

s

m a

en e m

= _

a g

.m

.a 3 3 i j i

g a m gg a z a a a a g

m a w a w a g i i

m a a Es is

!=

===n

E.

I E

E i E E ! I mE mE E E I

,a u

E E

E, - s

_e

,, 2 2

a a y I_

g Ej y a ;

a.

E g y

I MNNE!XX N11!HHMMNNN

!NN!

=

I

a
a:a s

a a

aaa i II EEi!Eiiiiii i

iii!

I:

1. 1 5. 3 i i. i i 1 E

- - - = =

=

===_

m E u 5 m m E E m E E E

E E

-E E

i ei E

i i

d d 2 2 e d t C 2 2 E 2 E d d d d 2 2 2 2 2 2 2 d

2 2 2 2 l

5 4 4 4 4 4 4 4 E E E E E E E E E E E E

E E E E b

$ $ i I $ $ $

$ i i i i i ii i I i I

I I i i I.II.I.I.!.!.

l

,s 2

E E E E E E E IS E E i i i E. i EE E E E EE EE E E E

E E E E 64 s

y--

-y

-w

i 5

E E

d

=

C I

}

a s

=

E ME I

am

g I IIE=

lMa ll al s!

a i

E; E a a

8 as 5

IsI s

!:s In !s i s

8 55 8

=

se m

E =

E

=

E

<E

<E en a

?! g E g

8 a=

ge in it gi na a

e da e

.c e a

.m a

z

=

EE

.a a.

=

e +

si i_

iE *

  • 666 ===_

. =

ss EE sE EEEE EEE s

ss s

s E E E

!!MMMMMMMMM M

MM M

M MMM s

=

=

=

=

=

=

=

s g==

g s

e=m m

=

=

=

a g

g g g 5 g g g g g g =3 II I

==

=

E

=

E I I' aI Er

=

=

= = = =

=

=== ==== = = = E a a a

E a m W

3i E 3

=

m e

e m

a E a

!! ! B B B B g g g E a

E E E

=

E E E E E E I E E E E E E E E E E

E E E

E E E E M

m m

M m

m a

m m

m 5 5m 5 5m 5 5 m

5 5 5 5 5 Y 5 5 5

5 5 5 5 5

-w c e z e e e z z e e r r e e

a a z

e z e e B

ii i i i i i i i i i i i i

i i i

i i i i l

hT l

aa aaaaaaaaaaa a

aa a

a aaa 1

1 65

m Page No.

le

'92/11/87 seses IEST AAIAII seese COUNTAf CONTACT FACILIII iMNSIENT CSE TESI EIMAINENT EIPfalNENT -

TYPE IMIREA IfrE ESCRIPilIN WS4 M. N!LLIP TINS WIF EPMAIE EFFECTS IAE-PFI 12 USA M. PHILLIP IING WIF SEPMAIE EFFECTS IRAC-Pfl 13 MA M. NILLIP IIM WTF SEPMATE EFFECTS IAE-Pfl 14 USA W. PWILLIP IING WIF SEPMATE EFFECTS TRE-Pfl 15 USA M. NILLIP IINS WiF EPM 41E EFFECTS TRAC-Pfl 14 USA M. NILLIP IIM CCIF SEFMAIE EFFECil 1AE-Pfl

$4 USA M. MILLIP IINE CCIF KPAMIE EFFECTS TREW1

$7 USA NR. NILLIP IINE CCif SEPAAATE EFFECIS TRE-Pfl 50 USA M. NILLIP IIM CCTF EPARATE EFFECTS TRACW1 59 USA M. NILLIP IIM CCIF EPetAIE EFFECTS 1AE-PFI 70

$ USA W. NILLIP IINE CCIF EPARATE EFFECIS TREWI 71 MA M. PNILLIP TING CCIF SENAAIE EFFECIS TRACWI 72 -

USA M. NILLIP IINE CCIF SEPARAIE EFFECIS IAK-PFL 75 USA M. PHILLir IIM CCTF E NAAE EFFECil IRAC-Mi 76 MA NR. MILLIP ilNE CCTF EPARATE EFFECIS TRAC W I 77 USA M. NILLIP 11NE CCTF EPARAE EFFECIS 1AAC-Mi 75 USA M. PHILLIP IING CCIF EPARATE EFFECIS TREWI 79 USA W. MILLIP TINE CCIF SEPARAE EFFECIS TRAC W I 80 USA M. NILLIP 11N6.

KIF SEPARATE EFFECTS

. TRE-Pfl 529 USA M. NILLIP 11NG Eff EPAMIE EFFECTS TRE-PFI 644 USA M. NIL 11P IINE KIF SEPMAIE EFFECTS TRE-Mi 605 USA NR. MILLIP TIAS KIF SEPAAAIE EFFECTS TRAC-PFI 648 USA M. NILLIP IINE Kif ENAATE EFFECIS IAAC-PFI 610 USA M. PtolLLIP 11NS E!F EPMATE EFFECTS.

TRAC-Pfl all

a a

E

=

=

3 E

E O

56

=

=

Eg==

e

a am "E

".W z

1

==

e es e

=.

IE E

c s a w a wg ug

=

. g a

i

.8 a g a, gm g a w n n-

_s

= = = g u

  • I E I EE EE w g

5 5 i i Me EE.

IE l.s s 5

.R.N

,s

-E s

-. a W-a w a

_u u m E I-e s5 8 W

_h u

.= a

.m m

m.

ma EE

$ w w w w

9 9 9 ?

?

Y

-w g

a e e e e

w EE 5 5 5 = E n n E E E E 5 s

  • V 4 5 5 4 V 4 9 9 5 4 5 4 5 ? ? ? 4 4

4 w w w w w y y y y y Nw yy y w w w w w w

w E

= = =

=

= = =

=

=

=

=

c c e e c = = = s s

= s e a a

=

= = = = e g = =

= =

e

m = = m

m m m e e m = E

=

" ~=

w w w w w w w w w w w w = = -

= w w w w w

w gr

.E E E.E E E E E E {

E [ E -I E

.I E 8 E E E

E

=

m a 9 m a a a a a a a a a a a m = = = =

=

=

W gg g a a a a a

= = =

,,, N 3 I

  • E W W E W W

-a-

=

= g g a s A

I$ $$

E g

= =

- _.. =

~

u u u e e e s a w I E E E E E w

w w w w w w w w w w w w w w w a w w w w w

w

==== = = ==

= = =

= = =

=

=

h h h h h k h h h k k h h h k h h h k h

_3 2

_ _ _ _ _ z z

_ _ z z e

- - - = =

z

=

w e _

2_

2 2 2 d 2

_2 2

d 2 2 2 2 2 2 2

_2 2_

d

_2 z z z e e e z

= m _ - -

= z e a

a a-a a a-a-a a a-a-

a-a w n-a-

e a-a e a-a a-e

=

E' O 1

=

5 67

1.I

  • 5 5 g3 3 i

i i

-E m

u W W 4

3 =3 3 3 i

gg 5 5 w =.

M 1

en v

EWE eE E

t E.

E.

T as

-g W M S EE N N N i

f i

1 em e

que t t t t

E l

3 3

I S

g 4 d 3 5 5 1

E W W =

3 E E 5 i

=

W en ee me 3

I $

2 E E i

1 W

4 i

1 i

2 Y Y

=

k k k 2 2 6 W

f f f

  • ~

z a.

a c:

i d'=

e 5

t=

E E E E j

=

m l

68-

  • u.s.covcawcar niatinc crricc.im.isi.euisoass t

I a.,...

~ -,

I u s. nucLEAnuuttfoa7 ca iss o.

i smaT vu.Ew.c., r,oc.

, v., =,.,,

g,eoa==

ITo*"3#1 '

BIBLIOGRAPHIC DATA SHEET NUREG-1271

.EE thstauCTIONS oN TME at-E 2 TITLE ANo sueTaTLE 3 ggaygggggg Guidelines and Pr dures for the International Code Assessment and App tions Program 4 OATE aEP COMPLET ED II vtA.

MONTM April

/

1987 t

tv7Moa,s,

' F' aaa' '55u'a P. Ting, D. Bessette, R.

nson MONTM /

VEAa April /

1987 7 t EdeFOawiNG OaGANf2ATBO= NAuf ANo Maitt4G Ao s i,a,w to Cody, 4 PaOJECT/Tf Moan UN I muusta Division of Reactor and Plant 4 stems

/

Office of Nuclear Regulatory Re arch amo A~T =uana l

U.S. Nuclear Regulatory Commissi' A

i l

Washington, DC 20555 l

fi. Tvet o, aEcoaT io sco=soa.=G oaGA= 2 Ario= =*wE *=o uAiu=G AcoaEss,, w i Same as 7, above.

\\

.,Eaioo covEato,,

Y 12 suPPLEMENTAav NOTES i3 A8sYsAC T (JGD esra er W k.

This document presents the guideli_ sa procedures by which the International Code Assessment and Ap cation Program (ICAP) will be conducted. The document sumarizes he manag nt structure of the program and the relationships bet n and respo~ ibilities of the United States Nuclear Regulatory Commis on (USNRC) and.

e international participants. The procedures f code maintenance. nd necessary documentation are described.

idelines for the pe ormance and documentation of code assess t studies are present' An overview of an effort to quantify code une tainty, which the ICAP s' ports, is included.

i 1

\\

\\

\\

\\h

\\

s is ooc iut=T A=ALvsis -. utvwoaos-scairToas is AvA uTv ICAP RELAP5 TRAC-BF1 kinlimited TRAC-PF1 4Evaav c'a55*'c^o*

Code Ass oE~T.,iE as,o,e s sme sified E= E~

"aus Unc i r.. -->

Unclassified i 7. NUMBEa OF P AGE.

l i,a.cf

f UNITED STATES seecat couarmcuss aArt NUCLEAR REGULATORY COMMISSION

' 5'^tst,E."

WASHINGTON, D.C. 20555

,,%,s,gg.,.

OFFICIAL BUSINESS I2055 O 78a 7 PENALTY FOR PRIVATE USE,6300 U

N I

U8 SVCS f0LICY g

UR MGT sq.pDR

,d-501 d4SHINGTON NUREG DC 205S5

>2 C

$co>dc Z

t,n TT CC I>

E l

i

.