July 7, 1986 Docket No. 50-267 Mr. R. F. Walker, President Public Service Company of Colorado Post Office Box 840 Denver, Colorado 80201-0840

Dear Mr. Walker:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - PREVENTIVE MAINTENANCE PROGRAM FOR CONTROL R0D DRIVE AND ORIFICE ASSEMBLIES We are reviewing your submittal dated February 3, 1986 (P-86078) proposing a new preventive maintenance program for the control rod drive and orifice assemblies (CRD0A) at Fort St. Vrain (FSV). We find that in order to complete our review additional information is needed as listed in the enclosure to this letter. Please provide this information within 45 days of the date of this letter.

The information requested in this letter affects fewer than 10 respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, original signed by Kenneth L. Heitner, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-B

Enclosures:

As stated cc w/ enclosure:

See next page DISTRIBUTION:

Docket File'

'NRC PDR' Local PDR SSPD Reading PNoonan CHinson KHeitner 8607100072 860707 Olynch PDR ADOCK 05000267 P

PDR HBerkow KParczewski JWermei,1 TH

/

nb SPD DPWRL-B:SS D DPWRL:-B:SSPD DP

-B:SSPD DPWRLn 5:SSPD Chin KHeitner:ac 0

ch HBerktw 017/ / 6 706///86 i/86 09/]/86

/ /86

/

LM o nc,

o UNITED STATES

[

p, NUCLEAR REGULATORY COMMISSION L

j WASHINGTON, D. C. 20555

....../

July 7, 1986 Docket No. 50-267 Mr. R. F. Walker, President Public Service Company of Colorado Post Office Box 840 Denver, Colorado 80201-0840

Dear Mr. Walker:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - PREVENTIVE MAINTENANCE PROGRAM FOR CONTROL R0D DRIVE AND ORIFICE ASSEMBLIES i

We are reviewing your submittal dated February 3,1986 (P-86078) proposing a new preventive maintenance program for the control rod drive and orifice assemblies (CRD0A) at Fort St. Vrain (FSV). We find that in order to i

complete our teview additional information is needed as listed in the enclosure to this letter. Please provide this information within 45 days of the date of this letter.

The information requested in this letter affects fewer than 10 respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, Y.

Kenneth L. Heitner, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-B

Enclosures:

l As stated l

cc w/ enclosure:

See next page 1

d j

Mr. R. F. Walker Public Service Company of Colorado Fort St. Vrain cc:

Mr. D. W. Warembourg, Manager Albert J. Hazle, Director Nuclear Engineering Division Radiation Control Division Public Service Company Department of Health of Colorado 4210 East lith Avenue P. O. Box 840 Denver, Colorado 80220 Denver, Colorado 80201 Mr. David Alberstein,14/159A Mr. J. W. Gahm, Manager GA Technologies, Inc.

Nuclear Production Division Post Office Box 85608 Public Service Company of Colorado San Diego, California 92138 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Mr. H. L. Brey, Manager Nuclear Licensing and Fuel Division Mr. L. W. Singleton, Manager Public Service Company of Colorado Quality Assurance Division P. O. Box 840 Fort St. Vrain Nuclear Station Denver, Colorado 80201 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Senior Resident Inspector U.S. Nuclear Regulatory Commission P. 0. Box 640 Platteville, Colorado 80651 Kelley, Stansfield & 0'Donnell Public Service Company Building Room 900 550 15th Street Denver, Colorado 80202 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Chairman, Board of County Commissioners of Weld County, Colorado Greeley, Colorado 80631 Regional Representative Radiation Programs Environmental Protection Agency 1800 Lincoln Street l

Denver, Colorado 80203 l

1 l

REQUEST FOR ADDITIONAL INFORMATION - PREVENTIVE MAINTENANCE PROGRAM FOR CONTROL ROD DRIVE AND ORIFICE ASSEMBLIES FORT ST. VRAIN (TAC 61066)

PLANT, ELECTRICAL, INSTRUMENTATION AND CONTROL SYSTEMS BRANCH The maintenance program for the Control Rod Drive and Orifice Assemblies (CRD0A) described in your submittal (letter dated February 3, 1986) lists several activities which should be performed in order to keep the CRDOA in operating condition. However, no details are given of the exact nature of these activities.

Particularly, the acceptance criteria for the inspections specified in the program are missing. Please augment the CRD0A preventive maintenance program to include the information requested below and submit the requested information for our review.

(1) Please provide the acceptance criteria for the visual inspections of the following components listed in your proposed preventive maintenance program:

o pinion gear and brake pads in the shim motor / brake assembly o

drive. train o

cable o

hopper and samples of materials from the reserve shutdown system o

orifice drive motor assembly o

lower seal o

primary seal - 600 assembly o

primary seal - 200 assembly (2) Please describe the nature of the analyses and the acceptance criteria applied to the results of these analyses for the following items:

o surface wipes of the cable materialsfromthereserveshuttpwnsystem o

(3) Pleas *eprovideacceptancevaluesforkhemeasuredtorquesinthe foll6 wing components:

shim motor / brake assembly o

(removedfromCRD0AandinstallfdonCRD0A) o drive train (4) Provide acceptance values for the measured Back-EMF in the following components:

)

o shim motor / brake e.ssembly 6

drive train

(5) Please provide acceptance values for the megger motor tests.

(6) Please specify the cleaning and lubricating procedures to be used in the maintenance program.