_
9.
a
' June 11,-1987-Docket No.450-508.
Mr. D."W. Mazur,. Managing Director-Washington Public Power Supply System 13000 George. Washington Way Post-Office Box 968 Richland, Washington 99352
Dear Mr.'Mazur:
Subjecti Safety Evaluation Concerning The Application Of ITT/Grinnell-Stiff'
-. Pipe Clamps At WNP-3 l
cAfter the start of construction of WNP-3, we were notified of certain defi-ciencies in the' design.of the ITT/Grinnell Figure 215 type stiff clamps to safety-related' piping systems at WNP-3.. To resolve.these concerns, ITT/Grinnell modified the original clamp design.- Through the review of the modified design
.and the responses'to extensive questions, we have determined that this.
type of clamps are acceptable for use and' application in safety-related piping systems.at WNP-3. Our associated Safety Evaluation is enclosed.
This Safety Evaluation can be consolidated with the Draft Safety Evaluation Report which was submitted to you by letter dated November 19, 1985.
Sincerely, original signed by Herbert N. herkow, Director Standardization and Non-Power Reactor o
Project Directorate 8706180062Og6 MOB Division of Reactor Projects - III, IV, V PDR ADOCK 0 PDRc and Special Projects A.
Office of' Nuclear Reactor Regulation
Enclosure:
'As Stated i
cc: See next page-I DISTRIB JTJON:
@ Docket;EUeg EHylton OGC-BETH MHartzman
'NRC'&LocalP9k GVissing EJordan i
PDSNP Reading THichaels JPartlow DCrutchfield HBerkow ACRS (10)
{
l GVitTin5[:cw PDS. /.
PDSNP///
.PDSNP-s HB'e
.EHylton 06/ /87 06////87 06////8 06/N/87
+pa nauqjo UNITED STATES N
g
{
NUCLEAR REGULATORY COMMISSION n
i U
b WASHINGTON, D. C. 26555 I
r
[
June 11, 1987 Docket No. 50-508 Mr. D. W. Nazur, Nanaging Director Washington Public Power Supply System 3000 George Washington Way Post Office Box 968 Richland, Washington 99352
Dear Mr. Mazur:
i
Subject:
' Safety Evaluation Concerning The Application Of ITT/Grinnell Stiff Pipe Clamps At WNP-3 After the start of construction of WNP-3, we were notified of certain defi-ciencies in the design of the ITT/Grinnell Figure 215 type stiff clamps to safety-a related piping systems at WNP-3. To resolve these concerns, ITT/Grinnell modified the original clamp design. Through the review of the modified design and the responses to extensive questions, we have determined that this type of clamp is acceptable for use and app-lication in safety-related piping systems at WNP-3. Our associated Safety Evaluation is enclosed.
This Safety Evaluation can be consolidated with the Draft Safety Evaluation l
Report which was submitted to you by letter dated November 19, 1985.
Sincerely, M
A erbert N. Berkow, Director Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation
Enclosure:
As Stated cc: See next page i
I
m g
+,
4 Mr. D. W..Mazur WPPSS Nuclear Project No. 3 Washington Public Power Supply System
.(WNP-3)
CC' Mr. Charles B. Brinkman', Manager Washington. Nuclear Operations-Combustion Engineering, Inc.-
7910 Woodmont Avenue Sutie 1310 Bethesda, Maryland 20814 Nicholas S. Reynolds. Esq.
DeBevoise & Liberman 1200 Seventeenth Street
.I Washington,.DC 20036 G.'E. Doupe, Esq.
Washington. Public Power Supply System 3000-George Washington Way.
Richland, Washington 99352 -
~Mr. Nicho?as D. Lewis, Chairman Energy Facility Site Evaluation Council fiail Stop PY-11 Olympia, Washington 98505 Mr. Douglas Coleman Washington Public Power Supply System P. O. Box 1223 Elma, Washington 98541 Mr. Robert T.' Dodds Regional Administrator, Region V U.S. Nuclear Regulatory Commission d
1450 Maria Lane Suite 210 Walnut Creek, California 94596
)
1 1
Mr. Eugene Rosolie, Director j
Coalition for Safe Power J
408 Southwest Second Avenue
{
Portland, Oregon 97204 1
?
)
i