ML20215B471
| ML20215B471 | |
| Person / Time | |
|---|---|
| Site: | Perry |
| Issue date: | 06/08/1987 |
| From: | Harrison J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Edelman M CLEVELAND ELECTRIC ILLUMINATING CO. |
| Shared Package | |
| ML20215B472 | List: |
| References | |
| NUDOCS 8706170339 | |
| Download: ML20215B471 (2) | |
See also: IR 05000440/1987009
Text
7......
.
.
.
. . . .
.y
- .
JUN 8
1987
'
i
l
Docket No. 50-440-
The Cleveland Electric Illuminating
Company;
LATTN: ~Mr. Murray R. Edelman-
Vice President
Nuclear Group
Post Office Box 5000
. Cleveland, OH 44101
. Gentlemen:
This-~ refers to the special safety inspection conducted by Mr. W. C. Liu of
this office on April 29-30, 1987, of activities at Gilbert / Commonwealth,
- Reading, Pennsylvania,-and.on May 1, 1987, of activities at-Perry Nuclear.
Power Plant; Unit 1, authorized by NRC Operating License No., NPF-58' and to
the discussion of our findings with Mr. K. Pech at the conclusion of the
inspection.
The enclosed. copy of our inspection report identifies. areas examined during
'
the inspection. .Within these areas,-the inspection consisted of a selective
examination of procedures and representative records, observations, and
'
interviews with personnel.
During this inspection, certain of your activities appeared to be'in violation
.
of NRC requirements, as described in the enclosed Notice. The inspection
showed.that action had been taken to correct the identified violation and to
prevent recurrence. Our understanding of your corrective actions are described
in Paragraph 2.d of the enclosed inspection report.
Consequently, no reply to
.the violation is required and we have' no further questions regarding this matter
at-this time.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of
this letter and the enclosed inspection report will be placed in the NRC
Public Document Room.
l
l-
pg
.
8706170339 B70600
ADOCK 05000440-
0I
Q
I
l
p-
,
'
.
,
The Cleveland Electric Illuminating
2
. Company
JUN 8
1987
g
<We wil.1 gladly. discuss any questions you have concerning this inspection.
' Sincerely,
$f f @ f fi81. $f Oned by. J.~J.~ Ilarrison
.
J. J. Harrison, Chief
Engineering Branch
' Enclosures:
1.
2 .'
Inspection' Report-
No. 50-440/87009(DRS)
cc w/ enclosures:
.F.L R. Stead, Manager, Perry
!
Plant Technical Department
l
M. D. Lyster, Manager,-Perry Plant
Operations Department
Ms..E. M. Buzzelli, General
Supervising Engineer, Licensing
.and Compliance Section
.DCS/RSB (RIDS)
.
.
Licensing Fee Management Branch
Resident Inspector, RIII
Terry J. Lodge, Esq.
-James W.. Harris,' State of Ohio
Robert M. Quillin, Ohio
Department of Health
State of.0hio, Public-
. Utilities Commission
i
1
-
I
1
ff) ^
RI I
RIII
RIII
R II
g
.
-
L
nma
Danielson
Kno
Ha rison
c/r/r7
W4(p7
Q?,
(