ML20214F447

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-424/86-33 Re Review of Readiness Review Module 9B, Chemistry. Module Provides Framework for Acceptable Water Chemistry Program.Adequacy of Implementation Will Be Assessed
ML20214F447
Person / Time
Site: Vogtle Southern Nuclear icon.png
Issue date: 11/13/1986
From: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: John Miller
GEORGIA POWER CO.
Shared Package
ML20214F448 List:
References
NUDOCS 8611250305
Download: ML20214F447 (3)


See also: IR 05000424/1986033

Text

~

- * -

officicd

,

NOV 131986

Georgia Power Company

ATTN:fr. J. H. Miller, Jr.

President

P. O. Box 4545

Atlanta, GA 30302

Gentlemen:

SUBJECT: NRC REVIEW 0F V0GTLE READINESS REVIEW MODULE 98, CHEMISTRY

The NRC has completed a detailed review, inspection, and verification of the

subject module which you submitted to the NRC. Periodic inspections were

conducted at the Vogtle site, and the resultant findings were discussed with

members of your staff at the conclusion of these inspections. Technical reviews

were also conducted in NRC Bethesda offices, and the findings from these reviews

have also been discussed with your staff.

Areas contained in the module which were reviewed, examined, and verified are

identified in the enclosed report. Within these areas, the inspection and

verification consisted of selected examinations of procedures and representative

records, discussions with personnel, observations of activities in progress, and

review of your licensing commitments.

I

Based on the NRC review, Module 9B provides the framework for an acceptable water

chemistry program. Inasmuch as the major elements of such a program (i.e.,

staffing, training, development of procedures, and construction of laboratory

facilities) had not been completed, our assessment of the Vogtle chemistry

program will be continued during future inspections.

During the review of this module, the staff's main concern was that the

implementation of the programs described in this module had progressed too

slowly. However, a recent inspection indicated that significant progress has

been made toward completion of the water chemistry program. We believe that

continued management attention is warranted to ensure completion of program

implementation by the projected fuel load date.

We will again be inspecting your programs for training and qualification of

personnel prior to licensing as part of the Near Term Operating License

Inspection Program and, during that inspection, we will assess the adequacy of

implementation of corrective actions associated with this review. It is expected

that, at that time, all open items and unresolved issues associated with training

should be corrected.

Based upon your responsiveness and your ongoing efforts to correct the

deficiencies noted during this review, it appears that Module 9B will be

acceptable once corrective actions have been satisfactorily implemented and

remaining concerns have been adequately resolved.

861125030S 861113

PDR ADOCK 05000424

0 PDR J [

.

. _ _

i

.

, s, .

.

Georgia Power Company 2

Should you have questions concerning this letter, please contact us.

Sincerely,

DRIGINAL SIGNED DY:

L NEl.SO:1 GRACE

J. Nelson Grace '

Regional Administrator

Enclosure:

Inspection Report No. 50-424/86-33

cc w/enci:

J . P. O'Reilly, Senior Vice President

/. Nuclear Operations

E. Conway, Senior Vice President &

Project Director

D. O. Foster, Vice President, Project

/ Support

VP. D. Rice, Vice President, Project

_ j Engineering

VR. H. Pinson, Vice President, Project

/. Construction

T. Beckham, Vice President &

General Manager - Operations

/R.A. Thomas,VicePresident,

/. DLicensing

S. Read, General Manager,

Quality Assurance

/C. W. Hayes, Vogtle Quality

Assurance Manager

vW. C. Ramsey, Manager -

vb. Readiness Review

B. Bockhold, General Manager,

Nuclear Operations

ML. Gucwa, Manager, Nuclear Safety

and Licensing

M. H. Googe, Project

Construction Manager

vE. D. Groover, Quality

Assurance Site Manager -

Construction

IJ.A. Bailey,ProjectLicensing

v'8. Manager

F. Trowbridge, Esq., Shaw,

  1. .Pittman,

B

Potts and

W. Churchill, Trowbridge

Esq., Shaw,

Pittman, Potts and Trowbridge

cc w/ encl: (See page 3)

1

.

, ~~. .

Georgia Power Company 3

.

j fcw/ encl: (Continued) ,

V E. L. Blake, Jr. , Esq. , Shaw,

Pittman, Potts and Trowbridge

/J.E. Joiner,Troutman, Sanders,

Lockerman and Ashmore

[J. G. Ledbetter, Commissioner,

Department of Human Resources

. H. Badger, Office of Planning

j and Budget

VD. Kirkland, III, Counsel,

Office of the Consumer's Utility

Council

D. Feig, Georgians Against

/ Nuclear Energy

y'M. B. Margulies, Esq. , Chairman,

Atomic Safety and Licensing Board

/ Panel

V Dr. O. H. Paris, Administrative Judge

Atomic Safety and Licensing Board

/ Panel

s/G. A. Linenberger, Jr. , Administrative Judge

Atomic Safety and Licensing Board

Panel

/B. P. Garde, Citizens Clinic, Director

Government Accountability Project

bec w/ encl:

\/E. Reis, GS0

dW. M. Hill, IE

\/M. Miller, NRR

'

4. Brach, GS0

yM. Sinkule, RII

v(. Christnot, RII

yNRC. Resident Inspector

Document Control Desk

State of Georgia

i RII RII RII RII / RII RII RI

i

l/) J/(k*/)/ 0M1l yJ6 kW tN}G /^ f

WRd)s{WGTo6fsen DCollins JP ohr MSinkuie VLBrowl.&

lee alker'

10/N/86 10 4 //86 10/2Z/86 10/7//86 10/ /86 10/ '86- ,

($//p/86

hples oj)eo

RII IE NRR ELD

MUL  % \!G lev

MErnst B r es TNovalctk EChristienbury

'

10/ /86 86 10/ /86 10/ /86

l'/ t o /60 ti/.c/ge,

i