10CFR50.36 gegy rwcme a one camp.ny og y I
gug.gmf8 Nucks Opmbom SCEAG May 15, 1987 l
l l
Mr. Harold R. Denton, Director Office Nuclear Reactor Commission i
U. S. Nuclear Regulatory Commission Washington, DC 20555 l
Subject:
Virgil C. Summer Nuclear Station Docket No. 50/395 l
Operating 1.icense No. NPF-12 l
Steam Generator Tube F* Application
Dear Mr. Denton:
The third inservice eddy current examination of Virgil C. Super Nuclear j
Station steam generator tubinct was performed during the montts of March and l
April 1987. This letter and dts attachments provide the results of inspections of F* tubes and is submitted in accordance with the requirements of Technical Specifications Section 4.4.5.5.d.
l The following basic program was used for each steam generator:
100 percent i
of rows 45 through 49 (all columns) for full length of tubincl; a 4"4 matrix i
of the remainder of the tubes, full length of tubing; a samp'e of the peripheral tubes, full length of tubes; all row 1 & 2 to the 14th support i
(14C) outlet side and an inspection of all inlet tube sheet regions within the remaining balance of steam generator tubes.
The examination was conducted ut'lizing digital multifrequency techniques.
The attachments provide the identification, by row and column, of each tube left in service for which F* was applied. All measurements are made from the tubeend(TEH)andareininches. For further clarification, the code "0RI" indicates distorted roll with possible indication and "N00" indicates no detectable discontinuity, "% TW" indicates % through wall, and "F* location" is the highest point above the tube end at which the F* criteria can be applied in accordance with Technical Specifications Section 4.4.5.4.
If you should have any questions, please advise.
Veytrulf76urs.
1 M4w hu an CJM/0AN jez Attachments l
c:
Page 2 l
1 070D22003D G70515 PDH AD0cK 00000395 gg U
FDR l
Mr. Harold R. Denton May 15, 1987 Page 2 c:
- 0. W. Dixon, Jr./T. C. Nichols, Jr.
E. C. Roberts
- 0. S. Bradham J. G. Connelly, Jr.
D. R. Moore W. A. Williams, Jr.
J. N. Grace Group Managers W. R. Baehr C. A. Price C.L.Ligon(NSRC)
R. M. Campbell, Jr.
K. E. Nodland R. A. Stough G. O. Perc< val R. L. Prevatte J. 8. Knotts, Jr.
S. R. Hunt NPCF File 4
Attachment I to Mr. Harold R. Dent:n Letter May 15, 1987 l
l Page 1 of 1 ATTACHMENT I SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION, UNIT 1 STEAM GENERATOR TUBE F* LIST S/G:
"A" IND A N
R0W COL
% TW F* LOCATION 0
1 6
86 TEH+7.6 TEH+19.3 3
7 96 TEH+2.8 TEH+19.3 3
15 76 TEH+17.8 TEH+18.8 6
10 45 TEH+3.5 TEH+19.3 6
18 71 TEH+6.2 TEH+18.4 7
14 44 TEH+13.8 TEH+19.4 7
60 54 TEH+6.5 TEH+19.2 11 82 80 TEH+14.1 TEH+19.2 12 32 41 TEH+18.1 TEH+19.4 15 55 40 TEH+17.9 TEH+19.2 16 99 67 TEH+18.3 TEH+19.3 18 95 76 TEH+5.6 TEH+19.1 24 7
87 TEH+17.1 TEH+18.9 25 46 76 TEH+15.7 TEH+19.6 27 53 40 TEH+15.1 TEH+19.6 29 31 94 TEH+16.5 TEH+19.3 29 38 71 TEH+16.4 TEH+19.2 30 46 65 TEH+5.1 TEH+19.1 30 58 56 TEH+16.1 TEH+19.6 32 52 40 TEH&l8.3 TEH&l9.6 32 64 88 TEH+18.1 TEH+19.6 35 101 78 TEH+18.1 TEH+19.6 37 57 70 TEH+18.2 TEH&l9.6 38 41 79 TEH+16.1 TEH+19.2 39 70 77 TEH+19.5 TEH+19.6 39 77 84 TEH+18.0 TEH+19.4 40 42 40 TEH&l4.2 TEH+16.1 41 25 84 TEH+19.6 TEH+13.4 41 71 85 TEH+18.9 TEH+19.6 43 73 87 TEH+13.2 TEH+19.1 43 82 57 TEH+15.2 TEH&l9.1 Total number of tubes with F* applied:
31
Attachment II to Mr. Harold R. 0:nt:n Lctter May 15, 1987 Page 1 cf 3 1
ATTACHMENT II SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION, UNIT 1 STEAM GENEPATOR TUBE F* LIST S/G:
"B" F* Application on Unplugged Tubes Ih N
R0W COL Y, TW F* LOCATION 2
58 40 TEH+18.7 TEH+19.4 2
60 96 TEH+16.4 TEH+18.3 3
14 91 TEH+15.6 TEH+18.9 3
69 52 TEH+3.8 TEH+17.9 3
71 88 TEH+6.5 TEH+19.4 4
63 93 TEH+17.0 TEH+19.4 5
7 89 TEH+18.9 TEH&l9.1 5
24 59 TEH+6.8 TEH+19.3 5
67 40 TEH+16.3 TEH+19.3 6
40 89 TEH+13.6 TEH+19.1 6
72 46 TEH+3.2 TEH&l8.8 7
37 40 TEH+16.5 TEH+18.5 8
31 98 TEH+16.5 TEH+19.1 8
69 83 TEH+18.2 TEH+19.0 10 24 88 TElt+16.7 TEH+19.0 10 27 90 TEH+16.1 TEH+19.3 11 21 40 TEH+15.0 TEH&l9.0 11 30 96 TEH+18.9 TEll+19.2 11 40 40 TEH+18.9 TEH+19.1 12 25 62 TEH+5.9 TEH+19.1 12 56 40 TEH+19.0 TEH+19.2 15 19 40 TEH+17.8 TEH+18.8 15 27 56 TElt+11.9 TEH+19.1 15 39 99 TEH+18.7 TEH+19.0 i
16 58 65 TEH+1.2 TEH+16.9 11 12 95 TEH+11.8 TEH+19.2
Attachment II to Mr. Harald R. D::nton Letter May 15, 1987 Page 2 cf 3 ATTACHMENT II SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER HUCLEAR STATION, UNIT 1 STEAM GENERATOR TUBE F* LIST S/G:
"B" F* Application on unplugged Tubes l
I N
R0W COL
% TW F* LOCATION 18 9
95 TEH+13.0 TEH+19.1 19 18 40 TEH+16.4 TEH+19.2 19 19 94 TEH+16.2 TEH+19.1 20 41 83 TEH+17.8 TEH+18.1 20 65 74 TEH+17.1 TEH+19.1 23 28 98 TEH+17.5 TEH+19.1 24 20 96 TEH+4.3 TEH+19.0 3
27 22 40 TEH+15.1 TEH+19.1 27 89 56 TEH+13.0 TEH+17.3 29 28 83 TEH+11.5 TEH+19.1 30 41 91 TEH+6.1 TEH+19.0 31 55 88 TEH+11.7 TEH+19.1 32 25 86 TEH+12.2 TEH+19.1 32 33 64 TEH+11.5 TEH+19.1 33 32 98 TEH+17.5 TEH+19.1 33 40 91 TEH+17.3 TEH+19.1 34 30 83 TEH+18.5 TEH+19.6 34 65 88 TEH+12.9 TEH+19.1 37 71 50 TEH+8.8 TEH+19.6 38 63 71 TEH+0.3 TEH+19.4, 39 48 88 TEH+16.9 TEH+18.1 40 62 89 TEH+0.4 TEH+16.7 40 67 40 TEH+17.2 TEH+19.1 40 71 93 TEH+16.0 TEH+18.9 42 44 47 TEH+17.0 TEH+19.2 44 30 77 TEH+14.4 TEH+19.1
Attachment II to Mr. Harold R. 0;nt'n Letter May 15, 1987 Pag 2 3 of 3 ATTACHMENT II SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION, UNIT 1 STEAM GENERATOR TUBE F* LIST S/G:
"B" F* Application on Unplugged Tubes IND A N
R0W COL
% TW F* LOCATION 0
5 33 40 TEH+17.0 TEH+19.4 5
60 72 TEH+8.2 TEH+19.4 9
49 94 TEH+18.7 TEH+19.2 6
Attachment III to Mr. Harold R. 0;nton Letter May 15, 1987 Page 1 of 1 ATTACHMENT III SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION, UNIT 1 STEAM GENERATOR TUBE F* LIST S/G:
"B" F* Application to previously plugged tubes I
N R0W COL
% TW F* LOCATION 2
72 91 TEH+18.9 TEH+19.4 3
72 DRI TEH+3.3 TEH+19.4 5
73 DRI TEH+8.1 TEH+19.4 34 68 60 TEH+14.2 TEH+16.0 5
64 DRI TEH+5.4 TEH+19.4 4
67 92 TEH+15.4 TEH+19.3 11 73 91 TEH+19.1 TEH+19.2 8
76 DRI TEH+17.3 TEH+19.0 34 40 72 TEH+2.0 TEH+19.4 44 42 96 TEH+19.1 TEH+19.2 44 35 60 TEH+5.3 TEH+19.4 7
9 DRI TEH+16.0 TEH+19.0 24 9
NDD TEH+
TEH+19.0 47 57 NDD TEH+
TEH+19.0 34 64 95 TEH+13.6 TEH+19.4 32 65 86 TEH+18.3 TEH+19.4 31 65 74 TEH+12.8 TEH+19.4 15 44 79 TEH+1.2 TEH+19.3 F* applied to previously plugged tubes:
18 F* applied to unplugged tubes:
55 Total F* applied for Steam Generator "B": 73 y
y
-,_.y
Attachment IV.to Mr. Harold R. Denton Letter May 15, 1987 Page 1 of 1 e
ATTACHMENT IV j
SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION, UNIT 1 STEAM GENERATOR TUBE F* LIST S/G:
"C" I
N R0W COL
% TW F* LOCATION 1
35 82 TEH+1.2 TEH+19.1 3
4 41 TEH+19.0 TEH+19.1 3
93 92 TEH+16.3 TEH+18.9 4
5 40 TEH+17.9 TEH+18.9 22 102 88 TEH+18.6 TEH+19.4 4
27 92 TEH+17.8 TEH+19.1 5
13 40 TEH+18.7 TEH+19.4 6
40 40 TEH+18.5 TEH+19.1 8
20 90 TEH+19.1 TEH+19.6 8
41 59 TEH+18.8 TEH+19.2 12 19 40 TEH+15.9 TEH+19.6 17 13 40 TEH+18.6 TEH+19.3 14 44 55 TEH+17.6 TEH+19.2 23 37 59 TEH+17.0 TEH+19.4 26 2,6 56 TEH+18.8 TEH+19.3 26 44 86 TEH+15.9 TEH+19.2 27 27 40 TEH+12.9 TEH+19.1 35 31 73 TEH+17.7 TEH+19.1 35 35 81 TEH+18.0 TEH+19.3 45 75 81 TEH+15.8 TEH+19.3 9
53 93 TEH+18.4 TEH+19.4 22 9
41 TEH+18.8 TEH+19.4 18 18 99 TEH+19.0 TEH+19.6 18 12 89 TEH+16.4 TEH+19.4 19 18 86 TEH+19.1 TEH+19.4 35 18 93 TEH+15.9 TEH+19.4 8
25 92 TEH+18.7 TEH+18.8 30 30 98 TEH+17.9 TEH+19.2 31 47 93 TEH+17.1 TEH+19.1 23 59 68 TEH+18.0 TEH+18.9 21 62 93 TEH+15.8 TEH+18.8 Total F* applied for Steam Generator "C": 31
-a