Y

D

.

/

APR 2g 1937

Docket Nos. 50-369, 50-370

License Nos. NPF-9, NPF-17

Duke Poyer Company

ATTN:VMr. H. B. Tucker, Vice President

Nuclear Production Department

422 South Church Street

Charlotte, NC 28242

Gentlemen:

-

SUBJECT: NOTICE OF VIOLATION

(NRC INSPECTION REPORT NOS. 50-369/87-04 AND 50-370/87-04)

This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by

W. Orders and S. Guenther on December 30, 1986, through February 10, 1987. The

inspection included a review of activities authorized for your McGuire

facility.

At the conclusion of the inspection, the findings were discussed

with those members of your staff identified in Inspection Report

Nos. 50-369/87-04 and 50-370/87-04 sent to you with a letter dated March 4,

1987.

Areas examined during the inspection were identified in the report.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

activities in progress.

The inspection findings indicated that certain activities appeared to violate

NRC requirements.

These apparent violations were discussed with you and

members of your staff during an Enforcement Conference held on April 16, 1987.

The violations, references to pertinent requirements, and elements to be

included in your response are described in the enclosed Notice o' Violation.

Violation A described in the enclosed Notice is similar to a violation

contained in the Notice sent to you by our letter dated July 2,1986. Because

"similar violations," as described in the NRC Enforcement Policy, are of

significant concern to the NRC, please give particular attention in your

response to the identification of the root cause of this problem (i.e., the

operator's apparent lack of familiarity with the function of equipment that he

authorized to be removed from service) and your corrective action to prevent

recurrence.

Your recent good record of compliance with Technical

Specifications causes this issue not be further escalated.

We commend you for your initiative in identifying the removed curbing around

the containment air return fans as cited in Violation 0 of the enclosed Notice,

and we look forward to further results from the improvements in your management

controls which were discussed in our March 6, 1987, management meeting. The

0705190302 070429

PDR

ADOCK 05000369

0

PDR

(

fE01

r

.

2 9 1997

Duke Power Company

2

significance of this issue was based on your past good perfoncance in the area

of refueling maintenance.

In accordance with 2.790 of the NRC's " Rule of Practice," Part 2, Title 10,

Code of Federal Regulations, a copy of this letter and its enclosure will be

placed in the NRC Public Document Room.

The responses directed by this letter and its enclosure are not subject to the

clearance procedures of the Office of Management and Budget as required by the

Paperwork Reduction Act of 1980, PL 96-511.

Should you have any questions concerning this letter, please contact us.

'

'

b

1

.

. Nelson Grace

Regional Administrator

Enclosure:

Notice of Violation

Sc w/ encl:

E. L. McConnell, Station Manager

Senior Resident Inspector - Catawba

cc w/ enc 1:

RC Resident Inspector

Document Control Desk

State of North Carolina

gD. Hood,NRR

.

ha f

'

f

RI

RII

RII

RII

'Of

, vy'ff

1

T e#eales:jt

/o V8'ro'wnlee

GJenkin ' f

MErnst

4/p /87

4/11/87

4/ /87

4/ /87