ML20212Q060

From kanterella
Jump to navigation Jump to search
Requests Addl Info Re 850818 Application to Renew License SNM-394,including Procedures Used & Results Achieved for Determining Capability of Nuclear Chicago 151A Counter & Confirmation That Survey Per Reg Guide 10.3 Will Be Used
ML20212Q060
Person / Time
Site: 07000435
Issue date: 03/28/1986
From: Glenn J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Moss H
LAFAYETTE COLLEGE, EASTON, PA
Shared Package
ML20212P877 List:
References
104272, NUDOCS 8702020128
Download: ML20212Q060 (2)


Text

f s

,/ h

'J G

MAR 2 81986 License No. SNM-394 Docket No.

070-00435 Control No. 104272 Lafayette College ATTN:

H. Gene Moss Associate Provost Easton, Pennsylvania 18042 Gentlemen:

This is in reference to your application dated August 18, 1985 to renew License No. SNM-394.

In order to continue our review, we need the following additional information:

1.

In Item 5 of your application for renewal of your license you have indicated that you will leak test your sealed sources using a Gieger-Mueller tube to check the swabs for contamination, however, you have not indicated how you have determined that your Nuclear Chicago 151A counter is capable of detecting the presence of 0.005 microcuries of plutonium and uranium.

Please submit the procedures you use and the results you have achieved for determining the capability of your instrument.

2.

You have not indicated in your application the type of survey and the instrument you will use for your sealed source survey.

Section 4.6.3.2 of Regulatory Guide 10.3 (enclosed) suggests the type of survey that should be performed for the sealed sources you possess.

Please confirm that you will perform such a survey.

3.

The NRC does not recognize an instrument check source calibration as a thorough calibration procedure.

Section 4.5.5 of Regulatory Guide 10.3 (enclosed) suggests a calibration procedure that the NRC finds acceptable and a calibration frequency of 12 months would be more appropriate for a facility such as yours.

Please confirm that you will follow an equivalent procedure.

4.

In your application you have not stated that personnel dosimetry is required to be worn by personnel using your sealed sources.

Section 4.6.2.1 and 4.6.2.2 of the enclosed guide suggests that an appropriate dosimeter be worn by personnel using the sealed sources.

Please confirm that you will require users to wear personnel monitoring that is capable of evaluating exposure due to neutron radiation or submit an appropriate evaluation of expected exposures from the proposed use.

}l{1 h OFFICIAL RECORD COPY ML 441 JENSEN - 0001.0.0 L

03/26/86 8702020128 861015 REG 1 11C70 SNM-M M PDR d

f O

O 2

We will continue our review upon receipt of this information.

Please reply in duplicate to my attention at the Region I office and refer to Mail Control No. 104272.

In order to continue prompt review of your application, we request that you submit your response to this letter within 30 calendar days from the date of this letter.

Sincerely, Origina1 Signed By :

Thomas K. Itempson John E. Glenn, Ph.D., Chief Nuclear Materials Safety Section B Division of Radiation Safety and Safeguards

Enclosures:

1.

10 CFR Part 19, 20, 30 and 70 2.

Regulatory Guide 10.3 RI:DRSS RI:DRSS Jensen/ca Glenn 3/ /86 3/17/86 0FFICIAL RECORD COPY ML 441 JENSEN - 0002.0.0 03/26/86 d