ML20212P114

From kanterella
Jump to navigation Jump to search
Rev 2 to Monthly Operating Rept for Oct 1986
ML20212P114
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 10/31/1986
From: Bregni L
DETROIT EDISON CO.
To:
Shared Package
ML20212P094 List:
References
NUDOCS 8703130281
Download: ML20212P114 (1)


Text

.

OPERATING DATA REPORT DOCKET NO.

50-341 COMPLETED BY L.P.Bregni DATE January 12, 1987 TELEPHONE (313)586-5313 OPERATING STATUS 1.

UNIT NAME:

Fermi 2 l Notes l

2.

REPORTING PERIOD: October, 1986 l

l 3

LICENSED THERMAL POWER (MWt):

3292 l

l 4.

NAMEPLATE RATING (GROSS MWe):

1215 l

l 5.

DESIGN ELECT RATING (Net MWe): 1093 l

l 6.

MAX DEPENDABLE CAP (GROSS MWe):

l l

7 MAX DEPENDABLE CAP (Net MWE):

l l

8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:

None 9

POWER LEVEL TO WHICH RESTRICTED, IF ANY (MWe Net):

218.6

10. REASONS FOR RESTRICTION, IF ANY: Fermi 2 is in the startup test phase and is currently authorized to operate not in excess of 20% of rated thermal power. (Ref. J. G. Keppler letter of September 12, 1986)

THIS MONTH YR TO DATE CUMULATIVE

11. HRS IN REPORTING PERIOD 744 969.9 969.9
12. HRS REACTOR WAS CRITICAL 354.6 401.8 401.8
13. REACTOR RESERVE SHUTDOWN HRS 0

0 0

14. HOURS GENERATOR ON-LINE 61.25 69.75 69.75
15. UNIT RESERVE SHUTDOWN HOURS 0

0 0

16. GROSS THERMAL ENERGY GEN (MWH) 121,536 131,472 131,472
17. GROSS ELECT ENERGY GEN (MWH) 4880 5620 5620
18. NET ELECT ENERGY GEN (MWH)

-8500

-10,543

-10,543 2$h

19. UNIT SERVICE FACTOR N/A N/A N/A
20. UNIT AVAILABILITY FACTOR N/A N/A N/A
21. UNIT CAP FACTOR (USING MDC NET)

N/A N/A N/A

22. UNIT CAP FACTOR (USING DER NET)

N/A N/A N/A

23. UNIT FORCED OUTAGE RATE N/A N/A N/A
24. SHUTDOWNS SCHEDULED OVER NEXT 6 MON (TYPE, DATE, DURATION OF EACH) NONE
25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP N/A 4
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):

FORECAST ACHIEVED INITIAL CRITICALITY 06/20/85 06/21/85 INITIAL ELECTRICITY 10/01/86 09/21/86 COMMERCIAL OPERATION 05/01/87

  1. To be determined 8703130281 870112 PDR ADOCK 05000341 R

PDR

_ _ _ _ _