WASHINGTON. D. C. 20555 I
%,.....J YANKEE ATOMIC ELECTRIC COMPANY YANKEE NUCLEAR POWER STATION DOCKET NO.50-029 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 98 License No. DPR-3 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Yankee Atomic Electric Company (the licensee) dated January 6, 1986 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the' Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. DPR-3 is hereby amended to read as follows:
8608270270 860820 PDR ADOCK 05000029 P
P D_R
. (2)
Technical Specifications The Technical Specifications contained in Appendix A as revised through Amendment No. 98, are h.ereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION W
lC b Eileen M. McKenna, Project Manager Project Directorate #1 Division of PWR Licensing-A
Attachment:
Changes to the Technical Specifications Date of Issuance: August 20, 1986 b
9 f
ATTACHMENT TO LICENSE AMENDMENT N0. 98 FACILITY OPERATING LICENSE NO. DPR-3 DOCKET NC.50-029 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the enclosed pages.
The revised pages are identified by the captioned amendment number and contain marginal lines indicating the area of change.
REMOVE INSERT 6-20 6-20 l
4 f
=
--n,.-.m,.4
-w-4
,,4 m
+
--r
ADMINISTRATIVE CONTROLS I
The reports shall also include the following: a summary description of the radiological environmental monitoring program including a' map of all sampling locations keyed to a table giving distances and directions from the reactor; and the results of licensee participation in the Intercomparison Program required by Specification 3.12.3, and discussion of all analyses in which the LLD required by Table 4.12-1 was not achievable.
b.
Semiannuk1 Effluent Release Report.
(1) Within 60 days after January 1 and July 1 of each year, a report shall be submitted covering the radioactive content of effluents released to unrestricted areas during the previous six months of operation.
(2) The radioactive effluent release reports shall include a summary of th?
quantities of radioactive liquid and gaseous effluents and solid waste released from the unit as outlined in Regulatory Guide 1.21. Revision 1, June 1974, " Measuring, Evaluating and Reporting Radioactivity in Solid-Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," with data summarized on a quarterly basis following the format of Appendix B th9reof.
In addition the Radioactive Effluent Release Report to be submitted 60 days after January 1 of each year shall also include an annual summary
- of hourly meteorological data collected over the previous year. This annual summary may be either in the form of an hour-by-hour listing on magnetic tape of wind speed, wind direction, atmospheric stability and precipitation (if measured), or in the form of joint frequency distributions of wind speed, wind direction and atmospheric stability.**
This same report shall include an assessment of the radiation doses
- due to the radioactive liquid and gaseous effluents released from the unit during the previous calendar year.
(The semiannual effluent release report submitted within 60 days of July 1 each year need not contain any dose estimates from the previous 6 months' effluent releases.) This report shall also include an assessment of the radiation doses from radioactive effluents to MEMBER (S) OF THE PUBLIC due to the allowed recreational activities inside the SITE BOUNDARY (Figures 5.1-3 and 5.1-4) during the previous calendar year. All assumptions used in making these assessments (e.g., specific activity, exposure time and t
In lieu of including in the radioactive effluent release report required to be submitted within 60 days after January 1 additional information that covers the summary of annual meteorological data and assessment of radiation doses, a supplemental report is permitted to be submitted within 90 days after January 1 containing this information.
i In lieu of submission with the first half year radioactive affluent i
i release report, the licensee has the options of retaining this summary of required meteorological data in a file that shall be provided to the NRC (m
upon request.
YANKEE-ROWE 6-20 Amendment No. fdI,JPO, 98