MONTHYEARML20211K8611999-09-0101 September 1999 Informs That There Has Been Some Confusion Re Recently Issued ODCM Generic Section Rev Which Needs to Be Clarified. Clarifications Are Listed ML20210P1361999-08-0404 August 1999 Notification of 990817 Meeting with Util in Rockville, Maryland to Discuss Status of Licensing Actions Submitted by Comm Ed & Plan for Proposed Licensing Workshop ML20210C7061999-07-16016 July 1999 Forwards Facility Submitted Outline & Initial Exam Submittal for Operator Licensing Exams Administered During Wk of 990607 ML20209H2231999-07-16016 July 1999 Forwards Operator Licensing Exam Repts 50-456/99-301(OL) & 50-457/99-301(OL) of Exam Administered During Wk of 990607 ML20206U2721999-05-13013 May 1999 Revised Notification of 990527 Meeting with Util in Lisle,Il to Discuss Results of Licensee Evaluation on Potential Chilling Effect Concern within Working Environ & Use of Overtime within Operations Dept Organization at Plant ML20206Q2751999-05-13013 May 1999 Forwards Official Case File for DPO-99-1,request of Review of Concerns Related to TS Setpoints & Allowable Value for Instrumentation Under Formal DPO Procedures,For Disposition in Accordance with Provisions of NRC MD 10.159 ML20206E9331999-05-0303 May 1999 Notification of 990524 Meeting with Commonwealth Edison,Co in Rockville,Md to Discuss Technical Issues Related to Proposed re-rack of SFPs at Braidwood Station & Byron Station ML20206U2801999-04-28028 April 1999 Notification of 990527 Meeting with Util in Lisle,Il to Discuss Results of Licensee Evaluation on Potential Chilling Effect Concern within Working Environ & Use of Overtime within Operations Dept Organization at Byron Station ML20206Q3211999-02-19019 February 1999 Responds to e-mail Message Sent on 980202,re Status of Staff Actions on Recipient Dpv.With Regard to Dpv Concerning Dynamic Testing of Instrument Channels at Braidwood,Staff Pursuing Resolution of Issue with Licensee ML20206Q3391999-01-0505 January 1999 Provides Update on Status of Resolution of follow-up Actions from Resolution of Dpv on Dynamic Testing of Instrumentation at Braidwood Station ML20155F6291998-11-0303 November 1998 Forwards Facility Outline & Initial Exam Submittal for Operator Licensing Exam Administered Wk of 980914 ML20155G4661998-11-0303 November 1998 Forwards Exam Repts 50-454/98-301(OL) & 50-455/98-301(OL) Administered on 980914-22 with as-given Written Exam Attached for Processing Through Nudocs & Distribution to NRC Staff,Including NRC PDR ML20155E7361998-11-0202 November 1998 Forwards NRC Operator Licensing Exam Repts 50-456/98-305 & 50-457/98-305 for Tests Administered on 980914 ML20154G2361998-10-0707 October 1998 Responds to Memo Sent on 981002 Re Resolution of follow-up Actions for NRR Differing Professional View Panel on Dynamic Testing of Instrumentation at Plant ML20196D7921998-10-0202 October 1998 Forwards Comments Related to Staff Responses to follow-up Actions Re Dynamic Testing of Instrument Channels at Braidwood ML20196D7801998-09-21021 September 1998 Informs That Staff Completed Review of follow-up Actions Identified in Memo from Bw Sheron to Ba Boger, on Dymanic Testing of Instrumentation Channels at Braidwood ML20151V2951998-09-0202 September 1998 Informs That Braidwood Station Concurs with Encl Proposed 980904 Util Response to NRC Re IPEEE ML20197C8041998-09-0202 September 1998 Informs That Braidwood Station Concurs with Proposed Encl Response to NRC Re RPV Integrity at Braidwood & Byron Stations ML20197C8301998-09-0101 September 1998 Informs That Rev 2 to Calculation BYR98-109/BRW-98-339-E Has Been Reviewed & Found Acceptable for Transmittal to Nrc. Draft Util Ltr Re Thermo-Lag Ampacity Derating Factor Calculation,Encl ML20237D4331998-08-21021 August 1998 Notification of 980903 & 04 Meetings W/Util in Rockville,Md to Discuss Technical Issues Related to Byron & Braidwood Improved Std TSs Conversion,Including Section 3.3,beyond Scope Issues,Closeout Packages & Amends to Current TSs ML20196D7211998-08-0404 August 1998 Responds to 980720 Memo from Sj Collins to Lj Callan Re When & How Mesac Approved.Licensee Installed Mirco Electronic Surveillance & Calibration (Mesac) Sys Measurement & Test Equipment as Backup Sys to Normal M&TE ML20196D7711998-07-22022 July 1998 Discusses Staff Review of Braidwood Mesac System ML20249A2231998-06-12012 June 1998 Notification of 980625-26 Meeting W/Util in Rockville,Md to Discuss Technical Issues Re Byron & Braidwood Improved Std TSs Conversion ML20216B6731998-05-11011 May 1998 Discusses Closure of TAC M94439 for Braidwood,Unit 1,steam Generator Replacement ML20217P0731998-04-29029 April 1998 Forwards NRC Operator Licensing Exam Repts 50-456/98-304(OL) & 50-457/98-304(OL) (Including Completed & Graded Tests) for Tests Administered on 980413-15 ML20217P0131998-04-29029 April 1998 Forwards NRC Approved Operator Licensing Exam (Facility Outline & Initial Exam Submittal & as-given Operating Exam) for Tests Administered During Wk of 980413 ML20217E3881998-04-23023 April 1998 Notification of 980506 & 07 Meetings W/Util in Rockville,Md to Discuss Technical Issues Re Plants Improved STS Conversion ML20217H5421998-03-31031 March 1998 Discusses Completion of SG Replacement Proj at Plant,Unit 1. Plant Resumed Power Operation on 980308 ML20216H6971998-03-17017 March 1998 Notification of 980326 Meeting W/Commonwealth Edison Co in Lisle,Il to Discuss Comed Request to Consolidate near-site Emergency Operations Facility Into Single Central EOF ML20216H3401998-03-17017 March 1998 Notification of 980331-0402 Meeting W/Util in Rockville,Md to Discuss Reviewer Comments on Byron & Braidwood Improved Std TS Submittal ML20203G8551998-02-23023 February 1998 Notification of 980305 Meeting W/Util in Rockville,Md to Discuss Status of Byron & Braidwood Licensing Issues ML20198G4921998-01-0707 January 1998 Forwards Facility Submitted Outline,Initial Exam Submittal & as Given Operating Exam for Test Administered During Wk of 971006 at Plant ML20198J6881998-01-0707 January 1998 Forwards NRC Operator Licensing Exam Rept w/as-given Written Exam for Tests Administered During Wk of 971006 at Plant ML20202E5831997-11-25025 November 1997 Notification of 971215 Meeting W/Commonwealth Edison Co in Rockville,Md to Review Schedule for Listed Plants Improved Std TS Conversion & Supplemental Submittals ML20203C3621997-11-25025 November 1997 Revised Notification W/New Starting Time of Meeting W/Ceco on 971215 in Rockville,Maryland to Discuss Review Schedule Byron & Braidwood Improved TS Conversion & Supplemental Submittals ML20202D2221997-11-25025 November 1997 Notification of Meeting W/Ceco on 971211 in Rockville,Md to Discuss Proposed Mod to Methodology for Estimating SG Tube Leakage Attributable to Outer Diameter Stress Corrosion Crack Indications Restricted from Burst for Plant SGs ML20236N5111997-10-22022 October 1997 Fowards Staff Response to 960912 TIA Re Containment Spray Additive Sys Conformance W/Design Basis & Tss.Analysis Concluded That 2,400-2,600 Ppm in RWST Acceptable ML20217K8271997-10-16016 October 1997 Notification of 971024 Meeting W/Util to Discuss Results of Comed Investigation Into Sensitivity of Proposed voltage- Dependent Growth Rates to Binning Strategy for ODSCC Indicators ML20212A1501997-10-15015 October 1997 Forwards Response for NRC RAI Re SG Interim Plugging Criteria 90 Day Rept for Braidwood,Unit 1 Sixth Refuel Outage (A1R06).Station Concurs W/Response as Proposed for CE ML20217D4261997-09-30030 September 1997 Informs of Scheduled Visits W/Nuclear Services at Gpu on Nov 14th & Visit at Commonwealth Edison on Dec 3rd & Would Like to Receive Any Info Available.Supporting Documentation Encl ML20217E1591997-09-26026 September 1997 Notification of 971001 Meeting W/Ceco in Rockville,Maryland to Discuss Licensee Plans for SG Replacement Program at Byron,Unit 1 ML20217B3901997-09-23023 September 1997 Forwards Questions Re Ceco Submittal of Revised SG Tube Rupture Analysis for Byron,Unit 1 & Braidwood,Unit 1 ML20210S8461997-09-0202 September 1997 Notification of 970904 Meeting W/Util in Rockville,Md to Discuss Comed Methodology,Including Assumptions for Calculating Radiation Exposure Doses Resulting from Predicted SG Tube Leakage in Event of Msb ML20217Q9531997-08-28028 August 1997 Notification of 970904 Meeting W/Util in Rockville,Md to Discuss CE Methodology,Including Assumptions for Calculating Radiation Exposure Doses Resulting from Predicted SG Tube Leakage in Event of Msb ML20210L7831997-08-18018 August 1997 Notification of 970826 Meeting W/Util in Rockville,Md to Discuss Comeds Methodology Including Assumptions for Calculating Radiation Exposure Doses Resulting from Predicted SG Tube Leakage in Event of Main Steamline Break ML20149L1901997-07-22022 July 1997 Notification of 970723 Meeting W/Commonwealth Edison Co in Rockville,Md to Discuss Results of Spring 1997,Braidwood,1 SG Tube Eddy Current Insp.Time of Meeting Rescheduled ML20149F2731997-07-0303 July 1997 Notification of 970723 Meeting W/Util in Rockville,Md to Discuss Results of Spring 1997 Plant,Unit 1 SG Tube Eddy Current Insp Including Determination of Impact of Data ML20138D2781997-04-28028 April 1997 Notification of 970430 Meeting W/Util in Rockville,Md to Discuss Results of EC Insps of Plant SGs Conducted During Present Refueling Outage ML20217D5461997-04-18018 April 1997 Forwards Partially Withheld Background Briefing Package in Preparation for 970425 Meeting Between Comed & Commission IA-97-178, Forwards Partially Withheld Background Briefing Package in Preparation for 970425 Meeting Between Comed & Commission1997-04-18018 April 1997 Forwards Partially Withheld Background Briefing Package in Preparation for 970425 Meeting Between Comed & Commission 1999-09-01
[Table view] Category:MEMORANDUMS-CORRESPONDENCE
MONTHYEARML20211K8611999-09-0101 September 1999 Informs That There Has Been Some Confusion Re Recently Issued ODCM Generic Section Rev Which Needs to Be Clarified. Clarifications Are Listed ML20210P1361999-08-0404 August 1999 Notification of 990817 Meeting with Util in Rockville, Maryland to Discuss Status of Licensing Actions Submitted by Comm Ed & Plan for Proposed Licensing Workshop ML20210C7061999-07-16016 July 1999 Forwards Facility Submitted Outline & Initial Exam Submittal for Operator Licensing Exams Administered During Wk of 990607 ML20209H2231999-07-16016 July 1999 Forwards Operator Licensing Exam Repts 50-456/99-301(OL) & 50-457/99-301(OL) of Exam Administered During Wk of 990607 ML20206U2721999-05-13013 May 1999 Revised Notification of 990527 Meeting with Util in Lisle,Il to Discuss Results of Licensee Evaluation on Potential Chilling Effect Concern within Working Environ & Use of Overtime within Operations Dept Organization at Plant ML20206Q2751999-05-13013 May 1999 Forwards Official Case File for DPO-99-1,request of Review of Concerns Related to TS Setpoints & Allowable Value for Instrumentation Under Formal DPO Procedures,For Disposition in Accordance with Provisions of NRC MD 10.159 ML20206E9331999-05-0303 May 1999 Notification of 990524 Meeting with Commonwealth Edison,Co in Rockville,Md to Discuss Technical Issues Related to Proposed re-rack of SFPs at Braidwood Station & Byron Station ML20206U2801999-04-28028 April 1999 Notification of 990527 Meeting with Util in Lisle,Il to Discuss Results of Licensee Evaluation on Potential Chilling Effect Concern within Working Environ & Use of Overtime within Operations Dept Organization at Byron Station ML20206Q3211999-02-19019 February 1999 Responds to e-mail Message Sent on 980202,re Status of Staff Actions on Recipient Dpv.With Regard to Dpv Concerning Dynamic Testing of Instrument Channels at Braidwood,Staff Pursuing Resolution of Issue with Licensee ML20206Q3391999-01-0505 January 1999 Provides Update on Status of Resolution of follow-up Actions from Resolution of Dpv on Dynamic Testing of Instrumentation at Braidwood Station ML20155F6291998-11-0303 November 1998 Forwards Facility Outline & Initial Exam Submittal for Operator Licensing Exam Administered Wk of 980914 ML20155G4661998-11-0303 November 1998 Forwards Exam Repts 50-454/98-301(OL) & 50-455/98-301(OL) Administered on 980914-22 with as-given Written Exam Attached for Processing Through Nudocs & Distribution to NRC Staff,Including NRC PDR ML20155E7361998-11-0202 November 1998 Forwards NRC Operator Licensing Exam Repts 50-456/98-305 & 50-457/98-305 for Tests Administered on 980914 ML20154G2361998-10-0707 October 1998 Responds to Memo Sent on 981002 Re Resolution of follow-up Actions for NRR Differing Professional View Panel on Dynamic Testing of Instrumentation at Plant ML20196D7921998-10-0202 October 1998 Forwards Comments Related to Staff Responses to follow-up Actions Re Dynamic Testing of Instrument Channels at Braidwood ML20196D7801998-09-21021 September 1998 Informs That Staff Completed Review of follow-up Actions Identified in Memo from Bw Sheron to Ba Boger, on Dymanic Testing of Instrumentation Channels at Braidwood ML20197C8041998-09-0202 September 1998 Informs That Braidwood Station Concurs with Proposed Encl Response to NRC Re RPV Integrity at Braidwood & Byron Stations ML20151V2951998-09-0202 September 1998 Informs That Braidwood Station Concurs with Encl Proposed 980904 Util Response to NRC Re IPEEE ML20197C8301998-09-0101 September 1998 Informs That Rev 2 to Calculation BYR98-109/BRW-98-339-E Has Been Reviewed & Found Acceptable for Transmittal to Nrc. Draft Util Ltr Re Thermo-Lag Ampacity Derating Factor Calculation,Encl ML20237D4331998-08-21021 August 1998 Notification of 980903 & 04 Meetings W/Util in Rockville,Md to Discuss Technical Issues Related to Byron & Braidwood Improved Std TSs Conversion,Including Section 3.3,beyond Scope Issues,Closeout Packages & Amends to Current TSs ML20196D7211998-08-0404 August 1998 Responds to 980720 Memo from Sj Collins to Lj Callan Re When & How Mesac Approved.Licensee Installed Mirco Electronic Surveillance & Calibration (Mesac) Sys Measurement & Test Equipment as Backup Sys to Normal M&TE ML20196D7711998-07-22022 July 1998 Discusses Staff Review of Braidwood Mesac System ML20249A2231998-06-12012 June 1998 Notification of 980625-26 Meeting W/Util in Rockville,Md to Discuss Technical Issues Re Byron & Braidwood Improved Std TSs Conversion ML20216B6731998-05-11011 May 1998 Discusses Closure of TAC M94439 for Braidwood,Unit 1,steam Generator Replacement ML20217P0731998-04-29029 April 1998 Forwards NRC Operator Licensing Exam Repts 50-456/98-304(OL) & 50-457/98-304(OL) (Including Completed & Graded Tests) for Tests Administered on 980413-15 ML20217P0131998-04-29029 April 1998 Forwards NRC Approved Operator Licensing Exam (Facility Outline & Initial Exam Submittal & as-given Operating Exam) for Tests Administered During Wk of 980413 ML20217E3881998-04-23023 April 1998 Notification of 980506 & 07 Meetings W/Util in Rockville,Md to Discuss Technical Issues Re Plants Improved STS Conversion ML20217H5421998-03-31031 March 1998 Discusses Completion of SG Replacement Proj at Plant,Unit 1. Plant Resumed Power Operation on 980308 ML20216H3401998-03-17017 March 1998 Notification of 980331-0402 Meeting W/Util in Rockville,Md to Discuss Reviewer Comments on Byron & Braidwood Improved Std TS Submittal ML20216H6971998-03-17017 March 1998 Notification of 980326 Meeting W/Commonwealth Edison Co in Lisle,Il to Discuss Comed Request to Consolidate near-site Emergency Operations Facility Into Single Central EOF ML20203G8551998-02-23023 February 1998 Notification of 980305 Meeting W/Util in Rockville,Md to Discuss Status of Byron & Braidwood Licensing Issues ML20198G4921998-01-0707 January 1998 Forwards Facility Submitted Outline,Initial Exam Submittal & as Given Operating Exam for Test Administered During Wk of 971006 at Plant ML20198J6881998-01-0707 January 1998 Forwards NRC Operator Licensing Exam Rept w/as-given Written Exam for Tests Administered During Wk of 971006 at Plant ML20202E5831997-11-25025 November 1997 Notification of 971215 Meeting W/Commonwealth Edison Co in Rockville,Md to Review Schedule for Listed Plants Improved Std TS Conversion & Supplemental Submittals ML20203C3621997-11-25025 November 1997 Revised Notification W/New Starting Time of Meeting W/Ceco on 971215 in Rockville,Maryland to Discuss Review Schedule Byron & Braidwood Improved TS Conversion & Supplemental Submittals ML20202D2221997-11-25025 November 1997 Notification of Meeting W/Ceco on 971211 in Rockville,Md to Discuss Proposed Mod to Methodology for Estimating SG Tube Leakage Attributable to Outer Diameter Stress Corrosion Crack Indications Restricted from Burst for Plant SGs ML20236N5111997-10-22022 October 1997 Fowards Staff Response to 960912 TIA Re Containment Spray Additive Sys Conformance W/Design Basis & Tss.Analysis Concluded That 2,400-2,600 Ppm in RWST Acceptable ML20217K8271997-10-16016 October 1997 Notification of 971024 Meeting W/Util to Discuss Results of Comed Investigation Into Sensitivity of Proposed voltage- Dependent Growth Rates to Binning Strategy for ODSCC Indicators ML20212A1501997-10-15015 October 1997 Forwards Response for NRC RAI Re SG Interim Plugging Criteria 90 Day Rept for Braidwood,Unit 1 Sixth Refuel Outage (A1R06).Station Concurs W/Response as Proposed for CE ML20217D4261997-09-30030 September 1997 Informs of Scheduled Visits W/Nuclear Services at Gpu on Nov 14th & Visit at Commonwealth Edison on Dec 3rd & Would Like to Receive Any Info Available.Supporting Documentation Encl ML20217E1591997-09-26026 September 1997 Notification of 971001 Meeting W/Ceco in Rockville,Maryland to Discuss Licensee Plans for SG Replacement Program at Byron,Unit 1 ML20217B3901997-09-23023 September 1997 Forwards Questions Re Ceco Submittal of Revised SG Tube Rupture Analysis for Byron,Unit 1 & Braidwood,Unit 1 ML20210S8461997-09-0202 September 1997 Notification of 970904 Meeting W/Util in Rockville,Md to Discuss Comed Methodology,Including Assumptions for Calculating Radiation Exposure Doses Resulting from Predicted SG Tube Leakage in Event of Msb ML20217Q9531997-08-28028 August 1997 Notification of 970904 Meeting W/Util in Rockville,Md to Discuss CE Methodology,Including Assumptions for Calculating Radiation Exposure Doses Resulting from Predicted SG Tube Leakage in Event of Msb ML20210L7831997-08-18018 August 1997 Notification of 970826 Meeting W/Util in Rockville,Md to Discuss Comeds Methodology Including Assumptions for Calculating Radiation Exposure Doses Resulting from Predicted SG Tube Leakage in Event of Main Steamline Break ML20149L1901997-07-22022 July 1997 Notification of 970723 Meeting W/Commonwealth Edison Co in Rockville,Md to Discuss Results of Spring 1997,Braidwood,1 SG Tube Eddy Current Insp.Time of Meeting Rescheduled ML20149F2731997-07-0303 July 1997 Notification of 970723 Meeting W/Util in Rockville,Md to Discuss Results of Spring 1997 Plant,Unit 1 SG Tube Eddy Current Insp Including Determination of Impact of Data ML20138D2781997-04-28028 April 1997 Notification of 970430 Meeting W/Util in Rockville,Md to Discuss Results of EC Insps of Plant SGs Conducted During Present Refueling Outage ML20217D5461997-04-18018 April 1997 Forwards Partially Withheld Background Briefing Package in Preparation for 970425 Meeting Between Comed & Commission IA-97-178, Forwards Partially Withheld Background Briefing Package in Preparation for 970425 Meeting Between Comed & Commission1997-04-18018 April 1997 Forwards Partially Withheld Background Briefing Package in Preparation for 970425 Meeting Between Comed & Commission 1999-09-01
[Table view] |
Text
._ :-
. . .' March 2, 1987 Docket Nos. STN 50-454/455 and STN 50-456/457 MEMORANDUM FOR: Steven A. Varga, Director Project Directorate #3
-Division of PWR Licensing-A FROM: Janice A. Stevens, Project Manager Project Directorate #3 Division of PWR Licensing-A
SUBJECT:
FORTHCOMING MEETING: DCRDR AND SPDS SITE AUDIT-BYRON AND BRAIDWOOD STATIONS DATE & TIME: March 10, 1987 (8:30 a.m. - 4:00 p.m.)
March 11,1987 (8:30 a.m. - 3:00 p.m.)
LOCATION: Braidwood Station Site Joliet, Illinois PURPOSE: Visit control room to review DCRDR corrective actions and improvements and SPDS operation; and continue discussions with Comonwealth Edison Company (CECO) on the HED justification / schedule questions listed in enclosure 2.
A detailed agenda is included as enclosure 1.
PARTICIPANTS: NRC/ Consultants CECO R. Eckenrode (NRC) S. Hunsader, et.al.
J. DeBor (SAI Corp)
T. Carlson (COMEX) i Janice A. Stevens, Project Manager Project Directorate #3 Division of PWR Licensing-A
Enclosures:
As stated cc: See next page NOTE: NRC meetinos are open to interested members of the public to attend as observers. Members of the public who wish to attend these meetings must contact J. A. Stevens, (301) 492-7829.
PD#h PD#3 JStetans L01shan
-af /87 3/ 2 /87 l
P"2889o9888% PDR L
l
MEETING NOTICE DISTRIBUTION A
l0scket: File NRC'PDR " '"
Local PDR NSIC PRC System PD#3 Rdg.
J. Stevens C. Vogan ORAS H. Denton H. Thompson C. Rossi S. Varga G. Lear B. Youngblood.
V. Noonan L. Rubenstein R. Ballard C. Berlinger J. Milhoan F. Rosa V. Benaroya OGC-Bethesda J. Partlow B. Grimes l E. Jordan
! ACRS (10)
OPA Receptionist PPAS/TOSB R. Eckenrode (NRC)
J. DeBor (SAI Corp)
T. Carlson (COMEX)
s.
E6.
Mr. Dennis L. Farrar Braidwood Station Commonwealth Edison Company Units 1 and 2-cc: Ms. Lorraine Creek Mr. William Kortier Route 1, Box 182.
Atomic Power Distribution Manteno, Illinois 60950 Westinghouse Electric Corporation ~
Post Office Box 355 Douglass Cassel, Esq.
Pittsburgh, Pennsylvania 15230 109 N. Dearborn Street Joseph Gallo, Esq.
Chicago, Illinois 60602 Isham, Lincoln & Beale Elena Z. Kezelis, Esq.
1150 Connecticut Ave., N. W. Isham, Lincoln & Beale Suite 1100 Three First National Plaza Washington, D. C. 20036 Suite 5200 .
C. Allen Bock, Esq. Chicago, Illinois 60602 Post Offices _ Box 342 Mr. Charles D. Jones, Director Urbana, Illinois 61801 Illinois Emergency Services and Disaster Agency Thomas J. Gordon, Esq.
Waaler, Evans & Gordon 110 East Adams Street Springfield, Illinois 62706 2503 S. Neil Champaign, Illinois 61820 George L. Edgar Newman & Holtzinger, P.C.
Ms. Bridget Little Rorem 1615 L Street, N.W.
Appleseed Coordinator Washington, D.C. 20036
' 117 North Linden Street Essex, Illinois 60935 Michael Miller, Esq.
Isham, L~incoln & Beale Mr. Edward R. Crass One First National Plaza Nuclear Safeguards and
.c Licensing Division 42nd Floor Sargent & Lundy Engineers Chicago, Illinois 60603 55 East Monroe Street Chicago, Illinois 60603 .
U. S. Nuclear Regulatory Commission Resident Inspectors Office RR#1, Box 79 Braceville, Illinois 60407 Regional Administrator, Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 i
_ . _ , _ . . _ _ . _ _ . . . . . _ . . , _ _ . . ~ . , _ _ _ _ _ _ . . _ _ _ . , . - - _ _ , , , , _ - _ . . _ _ _ . . _ . . . . . _
ENCLOSURE 1
- AGENDA RYRON/BRAIDWOOD DCRDR AND SPDS SITE AUDIT AT BRAIDWOOD STATION, UNITS 1 AND 2 Day One NRC Entrance Briefing and Introductions 8:30 am 9:00 am Detailed Discussion of HED Justification / Schedule Questions (See Attachnent 1) 1:00 pm Visit Control Room to review HEDs in Question 3:00 pm Review SPDS Operation and Open Item Status Day Two 8:30 am Visit Control Room to review DCRDR Corrective Actions and Improvements as Completed (e.g. color padding, mimicking, and green board) 1:00 pm NRC Caucus 2:00 pm Exit Briefing 4
j t
l L -. . . . _ .
~
ENCLOSURE 2 b
ATTACHMENT 1 HED JUSTIFICATION / SCHEDULE QUESTIONS e
4 m
G s
N,
BYRON /BRAIDWOOD HED QUESTIONS
- 1. HED No. 0283, Page 7.
The second refueling outage schedule for removal of the auto-closure feature on the steam generator water hammer prevention system appears excessive. If removal of this feature "will eliminate many reactor trips," - why not implement the modification during the first refueling outage?
- 2. HED No. 0363, Page 31.
The justification for leaving this Category 1, Component Cooling Water HED uncorrected is not adequate. Why not provide system pressure indication in the control room in order to help operators determine Component Cooling Water leakage?
- 3. HED No. 0372, Page 36 The justification for leaving this Category 2, control room noise HED uncorrected is not adequate. During emergency operations, the number of annunciator alarms would not be "relatively small" as stated in the justification.
Is direct voice communication difficult in the center desk area of the control room during abnormal or immediate post-trip operations?
- 4. HED No. 0003, Page 65.
The justification for leaving this Category 3, shared plant equipment HED uncorrected is not adequate. What is the safety significance of sharec' equipment conflicts?
- 5. HED No. 0447, Page 101.
l t
Under what circumstances can radio operation cause inadvertent i activation of safeguards systems? Is this a generic problem in the nuclear industry, or just at Byron and Braidwood? Are Braidwood areas in which radio use could have a negative impact being marked before the first refueling outage?
- 6. HED No. 0473, Page 127.
The justification for leaving this Category 2, remote panel alarm HED uncorrected is not adequate. There is a difference between an
( inappropriate alarm and a nuisance alarm. Are there remote panel alarms which should not be in the control room? If there are
[ inappropriate alarms in the control room, what is being done about it?
I 1
- 7. HED No. 0019, Page 138.
The justification for leaving this Category 2, illuminated annunciator HED uncorrected is not adequate. Why should the " Spent Fuel Pump Trip" annunciator box be illuminated during operations above 30% power when the dark board concept is in place?
- 8. HED No. 0400, Page 166.
The justification for leaving this Category 1, diesel generator control switches HED uncorrected does not address the problem finding. The problem finding states that the operator tripped the output breaker when he intended to adjust the diesel generator governor. Since the switches are identical, the operators feel that it is easy to make this mistake, therefore, they would like shape coded switches. The justification statement addresses synchronizing tasks with the output breaker instead of analyzing the governor switch shape problem. Since the switches are close together, wouldn't shape coding be helpful?
- 9. HED No. 0257, Page 202.
The justification for leaving this Category 1, ESF systems reset HED uncorrected is not adequate. What is the safety significance of no immediate feedback for ESF resets?
- 10. HED No. 0280, Page 205.
The justification for leaving this Category 2, steam generator level control HED uncorrected is inadequate. If the operators now have difficulty maintaining level with auxiliary feedwater because they do not have a narrow range SG level display, will there be any improvement in the future?
- 11. HED No. 0455, Page 207.
The justification for leaving this Category 2, Safety Parameter Display System HED uncorrected is inadequate. The problem finding states that SPDS octagon does not form a uniform shape because the system is designed to operate on particular points rather than ranges.
Therefore, when the plant is operating normally, the SPDS iconic octagon is not uniform. Is this misleading to the operators'/
- 12. HED No. 0417, Page 210.
The justification for leaving this Category 2, remote shutdown panel HED uncorrected is inadequate. The justification states that wide range RCS pressure is not needed at the remote shutdown panel, but the operators state that they "must constantly go to the high rad sample system" room for this purpose. What is the safety significance of not having wide range RCS pressure on the remote shutdown panel? Is there a CRT at the remote shutdown panel which can be used to display wide range RCS pressure? Is the CRT going to be operable during events when operators would be using the remote shutdown panel?
2
- 13. HED No. 0292, Page 227.
The justification for leaving this Category 2, feed and condensate flow conversion HED uncorrected is inadequate. Why are operators required to manually convert kilopounds per hour to gallons per minute? What is the safety significance of inadequate task performance?
- 14. H'ED No. 0526, Page 228.
The justification for leaving this Category 2, condensate booster pump flow conversion HED uncorrected is inadequate. Why are operators required to manually convert kilopounds per hour to gallons per minute?
What is the safety significance of. inadequate task performance?
- 15. HED No. 0090, Page 246.
The implementation schedule for this Category I HED modification to allow direct comparison between the hot leg and cold leg temperatures appears long. Why is this modification scheduled for the second refueling outage rather than the first? What is the safety significance of inadequate operator comparison of hot and cold leg temperatures?
- 16. HED No. 0271, Page 247. ,
The implementation schedule for this Category 2 charging and letdown flow meter scale increments HED appears long. Why is this modification scheduled for the second refueling outage rather than the first?
- 17. HED No. 253, Page 276.
The justification for leaving this Category 1, bulb test capability HED uncorrected is inadequate. Is there a bulb check program with an established schedule? What bulb failure rates have been experienced?
Is there a program to replace all bulbs on regular intervals in antici-pation of bulb failure?
- 18. HED No. 0459, Page 277.
. The justification for leaving this Category 1, short life light bulb
! HED uncorrected is inadequate. If up to 60 bulbs per day burn out, it t
is apparent that the operator's primary source of control actuation feedback is lost in each of those cases. The fact that bulbs are easy
. to change does not solve the problem. Is there a longer life bulb, i such as a light emitting diode (LED) bulb, available? Other plants are ,
l using LED bulbs with an average life expectancy of 11 years. i L 19. HED No. 0524, Page 294.
! The justification for leaving this Category I centrifugal charging pump i indicating light HED uncorrected is inadequate. Why should the
- indicator lights for these pumps violate the green board concept?
l 3 a
a
, , - ~,,.-r--,e., .w,.-m..,_-,,,,_ _ ym m n w . - ,
'.s .
s
- 20. HED No. 0529, Page 348, and HED No. 0533, Page 349 (G-58).
The justification for leaving this Category 2 switch position labeling HED uncorrected is inadequate. Is the pump breaker labeling convention
" trip and close" or " start and stop?" Are the pump switches consistently labeled across the boards?
- 21. -HED No. 0530, Page 350.
The justification for leaving this Category I switch labeling HED uncorrected is inadequate. One of the purposes of the DCRDR was to establish labeling that was consistent across the control boards and consistent with the procedures. Why make an exception for these pull-out-to-lock switches?
- 22. HED No. 0490, Page 387. ,
The licensee's response to this HED is not clear. If the BTRS mimic is not confusing why divide it into a dilution and boration mimic? What is the schedule for implementation of the new mimic?
- 23. HED No. 0549, Page 442.
The justification for leaving this Category 2 color coding HED uncorrected is inadequate. Might not a color coding scheme on the CRTs that is different than the control boards be confusing?
- 24. HED No. 0165, Page 446.
The justification for leaving this Category 2 printer speed HED uncorrected is inadequate. Does the printer speed accommodate the operator's information needs during accident conditions, when demand for timely information is greatest?