ML20212G409

From kanterella
Jump to navigation Jump to search
Forwards Pages Omitted from Inservice Insp Rept Transmitted W/He Morgan
ML20212G409
Person / Time
Site: San Onofre 
Issue date: 12/21/1986
From: Morgan H
SOUTHERN CALIFORNIA EDISON CO.
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
NUDOCS 8701200417
Download: ML20212G409 (24)


Text

-

r

/*'"

Southem Califom/s Edison Company SAN ONOFRE NUCLEAR GENERATING STATION P. O. BOX t 28 SAN CLEMENTE. CALIFORNIA 92672 H E. MORGAN TELEPHONE STATION GdANAGER (714)368-4241 December 21, 1986' Mr. John B. Martin, Regional Administrator U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement 1450 Maria Lane, Suite 210 lialnut Creek, California 94596-5368

Dear Mr. Martin:

Subject:

Owner's Report of Inservice Inspection, NIS-1 San Onofre huolear Generating Station, Unit 1

Reference:

(a) Letter from li. E. Morgan to J. B. Martin, Dated October 23, 1986 This letter confirms transmitta) of pages omited from the subject report due to clerical error.

Attachment I lists the transmitted pages and provides instruction for their inclusion in your file copy of the subject report which was transmitted by reference (a).

If you require any additional information please advise.

I Sincerely, NSW s

~

N k

e a:

o s

cc:

R. C. Robbins, ANIIS El AN C. R. Erickson, State of California C

$Dh

  1. 7:

.=

(0

.c-Co I

k f5701200417 861221 PDR ADOCK 05000206 g, f/

G-PDR

7C 7

gg ATTACHMENT 1 INSTRUCTIONS FOR INCLUSION OF PAGES IN INSERVICE INSPECTION

SUMMARY

REPORT FOR SAN GNOFRE NUCLEAR GENERATING STATION UNIT 1, INTERVAL 2 PERIOD 2, OUTAGE 1 The pages listed below are pages from Abstracts and/or NIS-2 Forms and are filed in numerical order by calendar year.

These Pages are to be inserted with the appropriate Abstract and/or NIS-2 Form in the listed report volume.

Number Page For Volume S01-041-84 page 3 4

S01-094-84 page 3 4

S01-001-85 page 3 4

S01-012-85 page 3 4

S01-026-85 page 3 4

S01-032-85 page 3 4

S01-038-85 page 3 4

S01-039-85 page 3 4

S01-040-85 page 3 4

S01-041-85 page 3 4

S01-042-85 page 3 4

S01-043-85 page 3 4

S01-044-85 page 3 4

S01-045-85 page 3 4

S01-046-85 page 3 4

S01-047-85 page 3 4

S01-164-86 page 1 5

S01-164-86 page 2 5

S01-164-86 page 3 5

S01-195-86 page 1 5

S01-195-86 page 2 5

S01-195-86 page 3 5

i 1

ASME SECTION XI S*

wilF tio. So /.J+4-/Y

^

t F0PN NIS-2 (back)

CERTIFICATE OF 00@LIANCE l

We certify that the statements made in this report are correct and this conforms to the rules of the ASME Code, renlacement (repair or replacement)

MMb_ #

S haL CA [+

fun, /o

,19 PJ' Signed '

towner or owner's Designee) Title water)

CERTIFICATE OF INSPELTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California caployed by Lumbermens Mutual Casualty Company of Long Grove. Illinois rtod trom have inspected the components described in this owner's Report during the e and f f//__ to my a /gy and state that to the best of my knowl belief, tais repair or replacement has been performed in accordance with Section XI

  1. d. / #

By signing this certificate, neither the Inspector nor his employer of the ASME: Code.

makes any warranty, expressed or implied, concerning the repair or replacement in this Ibrthermore, neither the Inspector nor his employer shall be liable in any Report.

aanner for any personal injury or property damage or a loss of any kind arising froa j

or comected with this inspection.

Calif. trS's kn Bow f.0s 11]iA (state or Provincy, National Board)

Comatssions Inspector's signature I

Date s u v' u 19 W i

supplemental sheets in tors or lists, sketches, or orawirgs may ne usea provtw (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data Note:

report is included on each sheet is recorded at the top of this form.

l i

D

}

l s

l i

i

e r

ASME SECT 10tl XI g

WNF NO. S0 / - #M-M l

g FORM NIS-2 (back)

CERTIFICATE OF C0FFLIA!CE a

We certify that the statements made in this report are correct and this _

reolacement (repair or replacement) conforas'to the rules of the A5bE Code, Signed d d

.M du &- _ f feg ze

, 19 &

towner or owner's Designee) Title tuate; i

h CERTIFICATE OF INSPECTION I, the undersigned holding a vatto commission issued by the National Board of Boiler ana Pressure Vessel Inspectors and the State or Province of California i

caployed by _ Lumbermens Mutual Casualty Comoany of _ Long Grove, Illinois have inspected the components described in this owner's Report during the pertod trom 4-tA.n 4 to h 2t te and state that to the best of my knowledge and belief, this fepair or replacement has been performed in accordance with Section XI t

t of the A9E Code. By signing this certificate makes any warranty, expressed or impiled, conce,rning the repair or rneither the Inspec

(

lacement in this Report. Ibrthermore neither the Inspector nor his employer shall liable in any samer for any person,al injury or property damage or a loss of any kind arising f or comected with this inspection.

b

{

Inspector's s W ture Commissions Cali f. 14.C$.

(state or Province, Nationat Board)

Date_

KAzuz. Lt 19g i

! **e (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this d report is included on each sheet is recorded at the top of this form.

J i

_4.----.-e-mwwe um,-mmuw ggr,v.---*,--

-mem,,w,,,-,ycw- - w. -

,y, 3--

yww-e.

ww pmm _+ -m

-v w

-o--ww-w-o---e-

~

r e

........ M K U P LOM xi 3 *pp I

  • 'a.5U.'AoJ-//

IDVI NIS-2 (back)

GYFIFICATE OF COFPLIANCE We certify that the statcoents made in this report are correct and this replacement conforms to the rules of the A5ft Code 7 Trepair dr7i:31EcemenET-~

~~ ~

Section XI.

Signed h~~~ $.

$sp.w d$i fg

r3wan.,26,19 FY

'Thr orTX5iePfiksignee)7Di (Datel '

CEXfIFICATE OF INSPECTION I, the undersigned holding a v'alid commission issued by the National Board of Botter aus Pressure Vessel Inspectors and the State or Province of _ _ California employed by Lumbermens Mutual Casualty Company of _ Long Grove, _Ill inois _ ___ __

have inspected the components described in this owner's Report during the period from belieT,'..his@ repair 'oi 'ripla.,._gg and state that to the best of my knowledge an 1

5-I._ to A.11 t

of the A9E Code. By signing this certificate, neither the Inspector nor his erployer makes any warranty, expressed or implied, concerning the repair or replacement in this Report. Furthermore, neither the Inspector nor his employer shall be Itable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

\\hh-Commissions Calif. 14 4e$.

Inspector's S qnature (State or Province, National Board)

~

Data Wm. 2.7,19 W Note: Supplemental sheets in Iorm ot lists, sketches, or drawings may be used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data report is included on each sheet is recorded at the top of this form.

1

r ASME SECDON XI g

J4 WNF h0.__50 / /MJ 8/

(

FDRM NIS-2 (back)

CEKTIFICAE OF COWLINCE We certify that the statements made in this report are correct and this repa1 cement conforms to the rules of the ASFE Code, (repair or replacement)

Signed g-d.

.bmv (.o' r go Aww., 2 6, 19 Pr (Owner or Owner's Designee) Title LUate)r CERTIFICAE OF INSPECTION I, the undersigned holding a valid commission issued Ef the National Board of Boiler and Pressure Vessel Inspectors and the State er Province of California cmployed by Lumbermens Mutual Casualty Company of _ Long Grove, Illinois have insp/ 95ected the comp / u / f 5onents described in this owner's Report during the rtod from zh3 to 2.

and state that to the best of my knowl e and belief, this repair or replacement has been performed in accordance with Section XI of the A9E Code. By signing this certificate, neither the Inspector nor his employer (

rakes any warranty, expressed or implied, concerning the repair or replacement in this Report. Ibrthermore, neither the Inspector nor his esp oyer shall be liable in any ranner for any personal injury or property damage or a oss of any kind arising from or connected with this inspection.

M zf Commissions Ca l i f. / 2. 7 L

/ InspectoY's signature (state or Province, National Board)

Date 2 /2.z.

19E Note: supplemental sheets in Lorm of lists, sketches, or drawings may be used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 throuah 4 on this data report is included on each sheet is recorded at the top of this lors.

.3 d[ <,3[

ASME SECil0N M wNF No. 50 /. s.s& N

(

k W 1 NIS-2 (back)

CERTIFICATE OF 00tfLIANCE We certify that the statements made in this report are correct and this replacement conforms to the mies of the MK code, (repair or replacement) signed L &.

J k.w d u s u xsN n.,19 x towner or owner's Designee) Titte tua CERTIFICATE OF INSPECTION I, the undersigned holding a valTd commission issued by the National Board of Boiler anc Pressure Vessel Inspectors and the State or Province of California employed by Lumbermens Mutual Casualty Company of _long Grove, Illinois have inspected the components described in this owner's Report ourtry the rted tros t 12..vr to 2.

2 w and state that to the best of my knowl e and belief, this repair or replacement has been performed in accordance with tion XI of the A9E Code. By signing this certificate, neither the Inspector nor his employer makes any warranty, egressed or implied, concerning the repair or replacement in this Report. Pbrthermore, neither the Inspector nor his esp oyer shall be Itable in any manner for any personal injury or oss of any kind arising from or connected with this inspection. property damage or a Miks--

Consissions Calif. W G +

Inspector's 3Ignature (state or Province, National Boara) 1 Dste hs. r-t 19E j

Note: supplemental sheets in gora or Itste, sketees, or aravtres may be usea provtase (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 the 4 on this data rcport is included on each sheet is recorded at the top of this ru.

p ASVE $!Cil0N XI WNF M0._SO / -o3 2.- 8 i

(

3. ff x s wIs-2 n,.cu CERTIFICAR OF CODFLIANCE nie certify that the statements made in this report are correct and this repair confores to the rules of the ASPE code, trepatr or replacementJ Signed btA

$k/L c A fmt.,us f744 9

,19 93 '

towner or owner's Instgnee) m ie tusues GNTIFICAR OF INSPECTICDI 1, the undersigned holding a valta cometsston tasuso ey the National Board of Botier ana Pressure Vessel Inspectors and the State or Province of California employed by

.umbermens Mutual Casualty Comoany of Long Grove. Illinois have inspectec; the components cascribed in thts owner's Regii. maring cne rtoa tras 3

2i-w to T *T-te and state that to the best of my knowl e and better, this repair or replacement has been performed in accordance with tion XI of the ASE Code. By signiry this certificate, neither the Inspector nor his e oyer makes any warranty, expressed or lied, concerning the repair or replacement i this Report. Marthermore neither the esmer for any person,al injury or tor nor his esp oyer shall be liable in any or comected with this inspection. property damage or a oss of any kind aristry from Nb ekw Commissions Ca L i f. I %+

Inspector's signature (state or rrovsnee, pattonal soara)

Data et 19 g

!wat R = lementat n a in zore oz atsts, ametm es, or araws a may ne uses provsana (1)sineIs8-1/2in.x11in. (2) information in Items 1 the 4 on this data report is included an each shee,t is recorded at the top of this t

6 9

,, a ea

..,,.rm.

3 of f ASME SECTION XI SO / /J/- h '

WNF N0.-

FORM NIS-2 (back)

CERTIFICATE OF 00tfLINCE We certify that the statements made in this report'are correct and this renlacement conforms to the rules of the ASME Code, (repair or replacement >

Section XI.

Signed

$ Mder M

N/cq /c

,19 8 F v

towner or owner's Designee) Title tuate; CERTIFICATE OF INSPECTION 1, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California cmployed by Lumbermens Mutual Casualty company of _ Long Grove. Illinois have inspected the components described in this owner's Report during the period trom Wy 3.

  1. 9 Af to /mV f a, dW and state that to the best of my know1' edge and be.tef, this repair or replacement has been performed in accordance with Section XI of the ASME Code. By signing this certificate, neither the Inspector nor his employer

(.

makes any warranty, expressed or implied, concerning the repair or replacement in this Ibrthermore, neither the Inspector nor his employer shril be liable in any Report.

manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

hAA[M Commissions Calif. Id V f A/6 %G f (state or Province, National Board)

Inspector's signature 19 &

Date mAy

  1. a Supplemental sheets in lora et lists, r, ketches, or drawirgs may be used provided Note (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data report is included on each sheet is recorded at the top of this form.

l 9

1 __ -

+

$O ASME SECUON XI WNF NO. SO /. e/r.M 1

(

FORM NIS-2 (back)

CERTIFICAE OF COWLIAICE We certify that the statements made in this report are correct and this renlacomont conforms to the rules of the ARE code, (repair or replacement)

Section XI.

Signed h k 8ubo M

/8au /C

,19 A (f

(owner or owner's Designee} Title tuateJ CERTIFICA1E OF INSPECTION I, the undersigned holding a valta commission issued my the National Board of Boiler

)

ana Pressure Vessel Inspectors and the State or Province af California W

Omployed by Lumbermens Mutual Casualty Company of Long Grove, Illinois have inspected the components described in this owner's Report during the pertoa tros

. 9A f to MW.o sqv and state that to the best of my knowledge and maJ 2 belief,'esis repair or replacement has been performed in accordance with Section XI of the A9E Code. By signing this certificate, neither the Inspector nor his employer

(

askes any warranty, expressed or implied, concernirg the repair or replacement in this Report. Ibrthermore, neither the Inspector nor his esployer shall be Itable in any manner for any personal injury or property damage or a loss of any kind arisirs from or comected with this inspection.

Calif. / sW [AJ d#ces' LE Commissions Inspector's signature (state or Province, National Board) 19M Date M&

1e liote: supplemental sheets in tors ot lists, sketches, or drawtrgs may De used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data report is included on each sheet is recorded at the top of this fors.

s O

p d.

4 r

-%. C

$e f

R~,

ASVE SECDON XI

[

f WNF 110. SO / - o@ 25 C

(

FORM NIS-2 (back) p

)1 f

x' CERTIFICATE OF CX)FFLIANCE Ps We certify that the statements made in this report ara correct and this reolacement conforms to the rules of the ASbE Code, (repair or replacement)

Section XI.

Signed N, g/ab Ma4//O

, 19 8f

[/

towner'or owner's Designeel Title twte>

CERTIFICNIE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler anc Pressure Vessel Inspectors and the State or Province of California caployed by Lumbermens Mutual Casualty Company of Long Grove, Illinois have inspected the components described in this owner's Report during the pertoa trom s'

th AY 3.14 M f '

to m nV la,ggf and state that to the best of my knowledge and belief, this repair or replacement has been performed in accordance with Section XI of the ASME Code. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair or replacement in this Report. Ibrthermore, neither the Inspector nor his employer shall be liable in any tanner for any personal injury or property damage or a loss of any kind arising from n

1 or'comected with this inspection.

I hM Commissions Calif. jf rv /A/dgeet l

Inspector's signature (state or Province, National Board) i Date JNtu

,a 19 W i

W.e: supplemental sheets in torm or Itsts, sketches, or drawings may be used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data report is included on each sheet is recorded at the top of this form.

i

? 4-x -

I

~

l i

i I

...u..

P i-Ac.VE SFCilf N XI wtGtiolyn/ 7 5 5 3$$

(

FORM NIS-2 (back) 8 CERTIFICATE OF CXMLIMCE We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code, (repair or replacement)

Section XI.

g Signed

^ E. &

c, kW A '<

er,19 BS~

7

/

towner or owner's Designee) Title tuates

~

CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler ana Pressure Vessel Inspectors and the State or Province of California caployed by Lumbermens Mutual Casualty Company of Long Grove. Illinois have inspected the components described in this owner's Report during the period trom s s-w to s - c -es-and state that to the best of my knowledge and l

belief, this repair or replacement has been performed in accordance with Section XI I

of the ASME Code. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair or replacement in this Report. Pbrthermore, neither the Inspector nor his employer shall be liable in any canner for any personal injury or property damage or a loss of any kind arising from or comected with this inspection.

dbm Commissions Calif. 1 4 G,q.

Inspector's signature (state or Province, National Board)

Dste 19 X Note: supplemental sheets in torm or lists, sketches, or crawings may De used provided.

(1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data l

report is included on each sheet is recorded at the top of this form.

d i

M P

e

,,.,.,.,v_

,,-,,,,n.,-,

,,,v.,

,n

.n-.,

,,,._,-,,-----,-.,,-,._..,,,,--w--

n,-

.--.-e

l imE HClim Il y

Wr;F fi0 j 0 / - #N'# -

(

4 FORM NIS-2 (back)

CERTIFICATE OF 00tfLINCE

~

We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASE Code, (repair or replacement)

Section XI.

Signed 0' n Y N/& -hC;5

% ~7

,19 8f~

r towner or owner's Designee > Title teate)

CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler ana Pressure Vessel Inspectors and the State or Province of California employed by Lumbermens Mutual Casualty Company of Long Grove, Illinois have inspected the components described in this owner's Report during the pertad trom w _3 _-t s-to g _ c ;te and state that to the best of my knowledge and belief, this repair or replacement has been performed in accordance with Section XI cf the ASME Code. By signing this certificate, neither the Inspector nor his employer

(

makes any warranty, expressed or implied, concerning the repair or replacement in this Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisirs from or comected with this inspection.

Gh =.

Commissions Calif. \\g4 I

Inspector's Signature (state or Province, National Board)

~

W a

19 g Date lete: Supplemental sheets in torm or lists, sketches, or drawirgs may be used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data report is included on each sheet is recorded at the top of this form.

l i

~

l

ASME SEcil0N XI 30 87 WNF NO. SOZv04U-SS I

FORM NIS-2 (back)

CERTIFICATE OF 00FFLIRCE We certify that the statements made in this report are correct and this repair conforms to the rules of the ASMF Code, repair or replacement)

Stgned Yt-4 Shr$4 eda-Sp;n.4

/Yht;t.

p,19 8f towner or owner /s Designee) Title wa te>

l CERTIFICATE OF INSPFLTION I, the undersigned holding a valid commission issued by the National Board of Botier i

ana Pressure Vessel Inspectors and the State or Province of California employed by Lumbermens Mutual Casualty Company of Long Grove, !!1inois have inspected the components described in this owner's Report during the period trom W -- c _-w _ to, r-8-w-and state that to the best of my knowledge and belief, this repair'or replacement has been performed in accordance with Section XI of the A9C Code.

By signing this certificate, neither the Inspector nor his employer cakes any warranty, expressed or implied, concerning the repair or replacement in this Report.

Furthermore, neither the Inspector nor his employer shall be liable in any aanner for any personal injury or property damaga or a loss of any kind arising from er comected with this inspection.

Mdw Inspector's" Signature _

Commissions Calif.14G4 (State or Province, National Board)

'Date tvbw 9,

19 Ts-leta 9=lemental sheets in torm or lists, sketches, or drawings may be used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data report is included on each sheet is recorded at the top of this form.

l l

i

.m.... _,, _..., _ _., _.... - - _ _. _, _

.-..x..-.--

r 3 d{[f ASME SECTION XI WNF No. So /- D y4-15

(

FORM NIS-2 (back)

CERTIFICNIE & 00WLIAICE We certify that the statements made in this report are correct and this repair conforms to the rules of the Astt; code, (repair or reptacament)

Signed b k/w bl-[

<&Rm Cd bmA

/HLy /4

, 19 {

(owner or owner's Designee) utte tuntej CERTIFICATE & INSPELTIW I, the undersigned holdire a vatto commission issued oy the National Board of Boiler ana Pressure Vessel Inspectors and the State or Province of California employed by Lumbermens Mutual Casualty Company of Long Grove, Illinois have inspected the components described in this owner's Report aartrg the pertoa tron M - s - n-to w a-a s-and state that to the best of my knowledge and belief, this repair or replacement has been performed in accordance with Section XI cf the ASE Code. By signirg this certificate, neither the Inspector nor his employer g

makes any warranty, expressed or implied, concernirg the repair or replacement in this Report. Ibrthermore, neither the Inspector nor his employer shall be liable in any namer for any personal injury or property damage or a loss of any kind aristry from or comected with this inspection.

~4 b Commissions Calif. i 4-(.4 Inspector's signature (state or Province, National Board)

Date Mw n

19g lets: supplemental sheets in tom or Itsts, sketches, or aravtrgs may ne usea proviceG (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data report is included on each sheet is recorded at the top of this form,

_1 --

i

ASME SECTION XI N o[ /[

(

WNF N0z__SO / -#MM FORM NIS-2 (back)

CDCTIFICATE OF 00PfLIAICE We certify that the statements made in this report are correct and this repair conforms to the rules of the' ASME Code, (repair or replacementJ Signed 18 s'4C a Nma ngy j r_,199rs towner or owner's DesigneeJ Title wateJ CERTIFICNIE OF INSPECTIW I, the undersigned holding a valta commission issued by the National Board of Boiler anc Pressure Vessel Inspectors and the State or Province of California c= ployed by Lumbermens Mutual Casualty Company of Long Grove, Illinois have inspected the cocponents described in this owner's Report during the riod trom s; - s - tr to sm er and state that to the best of my knowl e and belief, this repair or replacement has been performed in accordance with Section XI

(

of the ASME Code. By signing this certificate, neither the Inspector nor his er.ployer cakes any warranty, expressed or implied, concerning the repair or replacement in this Report. Ibrthermore, neither the Inspector nor his employer shall be liable in any samer for any personal injury or property damage or a loss of any kind arising from or comected with this inspection.

ML b Commissions Calif. 1 % q.

Inspector's signature (state or Province, bacional Board)

Dste kAM R

19g lete: supplemental sheets in form ot lists, sketches, or drawings may be used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data rsport is included on each sheet is recorded at the top of this form.

i k

n.-

nre a.

ASME SECil0N XI WNF NO S0/ #6-//

(

KRM NIS-2 (back)

I

(

CERTIFICATE & CDFLIMCE We certify that the statements made in this report are correct and this repa ir conforms to the rules of the ASME Code, trepair or replacement) c Section XI.

Signed R A W Sfq/;m-M (%Q

/%y.

/g,,19 TS-towner or owner's Designee) 51tle wate>

CERTIFICATE & INSpELTICE I, the undersigned holding a valid commission issued by the National Board of Boiler ana Pressure Vessel Inspectors and the State er Province of California Employed by Lumbermens Mutual Casualty Company of Long Grove, Illinois have inspected the components described in this owner's Report during the. period trom

%s.-c-;-

to s _,s-95 and state that to the best of my knowledge and belid, tais' repair or replacement has been performed in accordance with Section XI cf the ASME Code. By signing this certificate, neither the Inspector nor his employer g

takes any warranty, expressed or implied, concerning the repair or replacement in this l

Report. Furthermore, neither the Inspector nor his emp oyer shall be liable in any

(

camer for any personal injury or property damage or a oss of any kind arising from i

I or comected with this inspection.

' M ku-.

Commissions Calif. \\% 4-l-

Inspector's signature (state or Province, National soard)

I Date Mu n 19 g W.>ta: supplemental sheets in torm or lists, sketches, or drawings may be used provided (I) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data l

report is included on each sheet is recorded at the top of this form.

t l

l l

l l

l l

O 1

r ASME SFCT!0N XI g

3g YmF No. So /- O y 7-ff

(

FORM NIS-2 (back)

CERTIFICAE OF 00WLINCE We certify that the statements made in this report are correct and this roolacement conforms to the rules of the ASME Code, (repair or replacement)

Signed Skyy qla% &cf3. &neA

/Y y 9,19 V5~

k

~

towner or owner's Designee) Titl'e wate>

r CERTIFICAR OF INSPECTION 1, the undersigned holding a valid commission issued by the National Board of Boiler ana Pressure Vessel Inspectors and the State or Province of California employed by Lumbermens Mutual Casualty Company of Long Greve, Illinois have inspected the components described in tnis owner's Report during the period trom t=:,-N

'ils-to T rt -45' and state that to the best of my knowledge and belief, this repair or replacement has been performed in accordance with Section XI cf the MIME Code. By signing this certificate, neither the Inspector nor his employer

(

2akes any warranty, expressed or implied, concerning the repair or r lacement in this Report. Ibrthermore, neither the Inspector nor his employer shall Itable in any ganner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

dg b kw_

Commissicas Calif. 14 M Inspector's signature (state or Province, National Board)

Date Ng 19 h Note: Supplemental sheets in torm or lists, sketches, or crawings may be used prcvided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data report is included on each sheet is recorded at the top of this form.

l i

-,7,, -, - - -

,,,,.,,-,---,-..,,n,,,.,,,,n, n

,.nn..n.-

,_---,_n--_-..

1 7

10F 16 l

ASME SECTION XI ABSTRACT l

l SO 1-164-86 l

l Work / Repair Traveler No.

I I

I I

I l 1. Owner Southern California Edison Company Date May 15. 1986 l

l (Name) l l

1 l

2244 Walnut Grove Ave.. Rosemead. CA 91770 Sheet 1

of I

l l

(Address) l 1

l l 2. Plant San Onofre Nuclear Generatina Station Unit 1

l l

(Name) l l

l l

P.O. Box 128. San Clemente. CA 92672 l

l (Address) l I

I l 3. Work Performed by Bechtel Construction. Inc.

CWO 86041874000 l

l (Name)

Repair Organization P.O. No.,l l

P.O. Box 450. San Clemente. CA 92672 Job No., etc.

l lr (Address) l l

l l 4. Identification of System FEEDWATER (FWS)

P&ID 5178206 l

l Line S1-FWS-14114-4"-EG l

l S. Plant Tag No./ Equipment Serial No. I 6. Component /Name/ Size l 7. Cede and Class l l

l l

l l

Weld Repair /

  1. UP l Line S1-FWS-14114-4"-EG IASME Sec. I: XI-2 l l 8.

Purpose:

(Statement of Problem) l 1

I 1

NCR 501-F-3406: The existing weld between new weld 'UD' and valve SI-FWS-376 has l

l incomplete penetration.

l l

l l

1 1

I I

I I

I I

I I

I l 9. Narrative Summary: (Brief description of work performed) l l

1 l 1) The existing weld downstream of valve SI-FWS-376 was ground out per the NCR and rewelded l l

I.A.W. the WR-5.

l 1

1 1

I I

I I

I I

I l

l l

l l

1 I

I I

I I

I I

I l 10. Materials Used:

l l

N/A l

l l

Prepared by D. Helmold Date 5-15-86

2 OF16 FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI A5v: ngy 966 K _ M i -1 6 4 - Bc,

1. Owner Southern California Edison Company (Name) 2244 Walnut Grove Ave.. Rosemead. Ca. 91770 Date May 15.1986 (Address)
2. Plant San Onof re Nuclear Generatino Station Sheet 1

of 1

(Name)

P.O. Box 128. San Clemente. Ca. 92672

__ Unit 1

(Address)

3. Work Performed by Bechtel Construction. Inc.

CWO 86041874000 (Name)

Repair Organization P.O. NO.,

F.O. Box 450. San Clemente. Ca. 92672 Job No., etc.

(Address) 7

4. Identification of System FEEDWATER (FWS)

P&ID 5178206

5. (a) Applicable Construction Code ASME Section I. 1962 Edition Code Cases N/A Code Classified 2

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

1977,

S'i8 Addenda, Code cases N/A

' - 6.' Identification of Components Repaired or Replaced, and Replacement Components I

Name of I

Name of l Mfrs. Ser.

l Nat'l l Other lYear I Repaired, IASME CODEl-l Component l Mfr.

I No.

I Ed.

Ildentification lBuiltlReplaced, ori Stamped i 1_

l I

I No.

l l

l ReplacementlYes or Nol i

I I

I ILine:

I I

I I

l Weld Repair l N/A l

  1. UP l N/A IS1-FWS-14114-4"-EGI N/A l Repair l

No l

I I

I I

I I

I I

I l

l l

1 I

I l

l l

I I

I I

I I

I 1

l l

l l

l l

l 1

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

I I

I I

I I

I I

I l

I l

l l

I I

I l

l I

I I

i i

I I

I I

l l

1 1

I I

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

7. Description of Work The existing weld downstream of valve S1-FWS-376 was weld repaired.

Reference:

NCR S01-F-3406

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure Psig Test Temp.

OF

9. Remarks N/A (Applicable Manufacturer's Data Reports to be attached)

E 30F16 h*LF kk FORM NIS-2 (backl CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this repair conforms to the rules of the ASME Code, (repair or replacement)

{

.Section XI.

Signed &

ROI.

t 0 b62.

5-/5

,ig86 u

(Owner or Owner's Designee) Title (0 ate) l l

,l CERTIFICATE OF INSPECTION l

'c l I, the undersigned holding a valid commission issued by the National Board of Boiler l l and Pressure Vessel Inspectors and the State or Province of California

,l l employed by Lumbermens Mutual Casualty Comoany of Lona Grove. Illinois l

l have inspected the components described in this Owner's Report during the period from l l

uh>844 to.r/ n />-6 and state that to the best of my knowledge and l

l belief, this repair or replacement has been performed in accordance with Section XI l

l of the ASME Code. By signing this certificate, neither the Inspector nor his employer l l makes any warranty, expressed or implied, concerning the repair or replacement in thisl l Report. Furthermore, neither the Inspector nor his employer shall be liable in any l

l manner for any personal injury or property damage or a loss of any kind arising from l l or connected with this inspection.

l BldA d Comissions Calif. /L7 L I

l eV InspectoPs Signature (State or Province, National Board) l l

l l Date

.r / q 1gff_

l 1

1 Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data j

report is included on ecch sheet is recorded at the top of this form.

1

[:

q (g

n l

ASME SECTION XI ABSTRACT l

l S0- 1-195-86 l

.l Work / Repair Traveler No.

l l

l l 1. Owner Southern California Edison Company Date 8MS/86 l

l (Name)

I I

I I

2244 Walnut Grove Ave.. Rosemead. CA 91770 Sheet 1

of 1

l l

(Address) l l

l l 2. Plant San Onof re Nuclear Generatina Station Unit 1

l l

(Name) l l

l l

P.O. Box 128. San Clemente. CA 92672 l

l (Address) l l

l l 3. Work Performed by So. Calif. Edison Co.

M.0. 86050856 l

l (Name)

Repair Organization P.O. No.,l l

P.O. Box 700. San Clemente. CA 92672 Job No., etc.

l l

(Address) l l

1

~

l 4. Identification of System SALTWATER COOLING (SWC)

P&ID 5178350 (E-4) l l

l l S. Plant Tag No./ Equipment Serial No. l 6. Component /Name/ Size l 7. Code and Class l l

l 1

l l Sl-SWC-G-13B

/ JX1244 ISWC Pumo/Johnston Pumo/20" x 12" i Mf r. Std. XI-3 1

1,l 8.

Purpose:

(Statement of Problem)

~

l l

l MERS 552-86: A rebuilt pump was installed in plant location SI-SWC-G-138.

l l

l l

l l

l l

l l

l l

l l

l l

1 l 9. Narrative Summary:

(Brief description of work performed) l l

l l

l 1) Documentation for the pump was reviewed to verify compliance with the Mfr. Std., 1966; l

l BPC Spec. BS0-426A.

l l

l 1

l 2) The packing gland follower and discharge head from the existing pump in location l

l SI-SWC-G-13B were removed and installed on the rebuilt pump.

l l

l l 3) The rebuilt pump assembly was then installed in location SI-SWC-G-13B.

l l

1 J 4) A System Leakage Test (with VT-2) was performed.

l l

l l

l l

l l

l l

l l

l l 10. Materials Used:

l j

l See Blocks 5, 6 & 7 of Abstract.

l l

l l

Prepared by D. Helmold Date 8 / K /84 l

l

2,

l' ib

.9 V

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions cf ASME Code Section XI CC CCCC ____

_______ICri::C_ --n-=

C C-------==

-==------------------

ASu! SECit0N XI

  • !trIE 3Dl - M*I- %
1. Owner Southern California Edison Company (Name) 2244 Walnut Grove Ave.. Rosemead. Ca. 91770 Date M d a'4 /f84 (Address)
2. Plant San Onofre Nuclear Generatina Station Sheet 1

of 1

(Name)

P.O. Box 128. San Clemente. Ca.

92672 Unit 1

(Address)

3. Work Performed by Southern California Edison M.0. 86050856 (Name)

Repair Organization P.O. NO.,

P.O. Box 700. San Clemente. CA 92672 Job No., etc.

(Address)

4. Identification of System SALTWATER COOLING (SWC)

P&ID 5178350 (E-4) e

5. (a) Applicable Construction Code Mfr. Std. 1966: BPC Spec. BS0-426A Code Cases ___ N/A Code Classified 3

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

1977,

S'78 Addenda, Code cases N/A

- 6 Identification of Components Repaired or Replaced, and Replacement Components 3

l Name of I Name of I Mfrs. Ser.

I Nat'l l Other lYear i Repaired, I ASME CODEI l Component i

Mfr.

I No.

I Bd.

IIdentification IBuiltlReplaced, ori Stamped i I

I l

l No.

I l

l ReplacementlYes or Nol ISaltwater IJohnston l

I 1RSO 3151-86 I

l l

l lCelina PumplPump l

JX1244 l N/A ISl-SWC-G-138 l N/A l Replacement 1 No l

l I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

l i

I I

I I

I l

l l

l l

l l

l l

l

_I _

l l

l l

l l

l l

l l

l l

l 1

I l

l l

1 1

I I

I I

i 1

1 I

I I

I I

I l

l I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

l i

I I

I I

7. D2scription of Work A replacement Saltwater Coolina Pump was installed in location Sl-SWC-G-138.

Reference:

MERS 552-86

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other
  • X J

Pressure 32.5 Psig Test Temp.

69.9 0F

9. Remarks: Documentation for replacement pump available on site.

(Applicable Manufacturer's Data Reports to be attached) cA System Leakaae Test (with VT-2) was performed.

3 0F iu I

meur IECTIOli11 W RQ. 30 l - I 'i s ~ O b FORM NIS-2 (back)

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement Conforms to the rules of the ASME Code, (repair or replacement)

Section XI.

S1gned 111 elds W & W 0/id26", 3g 8(,

V (Owner or Owner's Designee) Title (Cate)

^

e.

l v

l 2

l CERTIFICATE OF INSPECTION l

i " _,l I-the undersigned holding a valid commission issued by the National Board of Boiler l l and Pressure Vessel Inspectsrs and the State or Province of California l

l employed by Lumbermens Mutual Casualty Company of Lono Grove. Illinois l

l have inspected the components described in this Owner's Report during the period from l l

E A R dC to t h W -S L and state that to the best of my knowledge and l

l belief, this repair or replacement has been performed in accordance with Section XI l

I of the ASME Code. By signing this. certificate, neither the Inspector nor his employer l I makes any warranty, expressed or implied, concerning the repair or replacement in thisl l Report. Furthermore, neither the Inspector nor his employer shall be liable in any l

l manner for any personal injury or property damage or a loss of any kind arising from l l cr connected with this inspection.

I 1

Commissions Calif. M64-l

=

l Inspector's Signature (State or Province, National Board) l l

1 l Date hrossnr h

19_E_

l l

1 I

i Nste: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 4 on this data rsport is included on each sheet is recorded at the top of this form.

l i

I

_ - _